An Experimental Study on Performance Characteristics of Two-Stage Compression Refrigeration Systems (2단압축 냉동장치의 성능특성에 관한 실험적 연구)

  • 김재돌;오후규;김성규;권옥배
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.25-32
    • /
    • 1994
  • The characteristics of the R-22 two-stage compression refrigeration systems were investigated. The apparatus consisted of 0.5HP and 1HP hermetic reciprocating compressors for the high and low stage sides respectively, a condenser, an evaporator, a heat exchanger, four expansion valves, and two intercoolers. The experiments covered a range of refrigerant flow rates from 24 to 84kg/h, and the inlet temperature of cooling water in the condenser and heat source water in the evaporator ranged from 20 to 30$^.\circ}C$The results Showed that the refrigerant flow rate had greater effect on the refrigerating capacities, the compression efficiency and the coefficient of performance of two-stage compression systems than the inlet temperature of heat source water. And all these values were decreased with increasing inlet temperatures of the cooling water. The pressure drops in the evaporator of two-stage compression systems were decreased in proportion to the increase in the inlet temperature of the heat source and cooling water, but it was increased by the refrigerant flow rate.

  • PDF

Thermo-mechanical stress analysis of feed-water valves in nuclear power plants

  • Li, Wen-qing;Zhao, Lei;Yue, Yang;Wu, Jia-yi;Jin, Zhi-jiang;Qian, Jin-yuan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.849-859
    • /
    • 2022
  • Feed-water valves (FWVs) are used to regulate the flow rate of water entering steam generators, which are very important devices in nuclear power plants. Due to the working environment of relatively high pressure and temperature, there is strength failure problem of valve body in some cases. Based on the thermo-fluid-solid coupling model, the valve body stress of the feed-water valve in the opening process is investigated. The flow field characteristics inside the valve and temperature change of the valve body with time are studied. The stress analysis of the valve body is carried out considering mechanical stress and thermal stress comprehensively. The results show that the area with relatively high-velocity area moves gradually from the bottom of the cross section to the top of the cross section with the increase of the opening degree. The whole valve body reaches the same temperature of 250 ℃ at the time of 1894 s. The maximum stress of the valve body meets the design requirements by stress assessment. This work can be referred for the design of FWVs and other similar valves.

Strategic Operation of the Artificial Aeration System for Water Quality Management of the Reservoir (저수지 수질관리를 위한 인공폭기 장치의 최적운전방안)

  • Lim, Kyeong-Ho;Jeong, Sang-Man;Han, Young-Sung;Park, Young-Oh
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.3
    • /
    • pp.261-270
    • /
    • 2002
  • The artificial aeration in the middle and the small scale reservoirs is widely used to destroy the stratified layer and algal boom. This study has been conducted at the Youncho reservoir located in Keoje island since Jan. 2000 to suggest the most suitable control strategy of the artificial aeration and reduce the side effect. The main results obtained from this research are as follows. The starting time of aeration for destratification was adjusted from the end of March to the beginning of April when the natural stratification is started. In order to prevent an anoxic condition the artificial mixing should be started by the middle of April when the DO in hypolimnion is dropped to less than $5mg/{\ell}$. The decrease DO, caused by the increase in water temperature, spreads rapidly from hypolimnion to themocline. Thermal stratification disappeared after the onset of artificial aeration within 7 days in the Yuncho reservoir. The air diffusers decrease water temperature in the layer of epilimnion and thermocline, but rise it in hypolimnion. The continuous operation of air diffuser prevent the stratification and anoxic condition in hypolimnion despite of the rising of water temperature and algal abundance. The algal abundance is not observed in effective zone by aeration. The turbidity rising problem induced from the aeration is avoided by keeping an air diffuser about 1.5m high from the bottom of lake. During the summer season, ceasing the aeration should be decided carefully. And also, it is necessary to operate the system it considering weather and temperature, and depending on the number and the position of aerators.

Seasonal Variation of Heterotrophic Activity in the Estuary of Naktong River over Half Tidal Cycle and Salinity Effect (낙동강 하구의 조석변화에 따른 Heterotrophic Activity의 계절적 변화와 염분의 영향)

  • 안태영;박중찬;하영칠
    • Korean Journal of Microbiology
    • /
    • v.29 no.5
    • /
    • pp.339-343
    • /
    • 1991
  • Heterotrophic activity, total bacteria and salinity were determined seasonally in the estuary of Naktong River over half tidal cycle. Heterotrophic activity was determined by the uptake of [U- $^{14}$ C]glucose. Heterotrophic activity fluctuated with the tides and was decreased as salinity increased. Teh great activity occurred near low ebb tide at all seasons except summer. The main environmental factor affecting hetreotrophic activity was the salinity rather than water temperature in the estuary of Naktong River. In order to estimate the effect of salt, salt was added to estuarine water. Vmax for glucose of salt-added water was 17% and 77% of original estuarine water at station 1 and 2 respectively and slight increase was observed at station 3. Respiration rate and Kt+Sn for glucose of salt-added sample increased at all 3 stations. The increase of the Kt value implies the reduced affinity of bacterial population for glucose. The effects of salinity on the heterotrophic activity were more extensive in the upper region of estuary than at the mouth.

  • PDF

Experimental Study on the Performance of a CO2 Heat Pump Water Heater under Various Operating Conditions (이산화탄소 급탕 열펌프의 운전조건에 따른 성능 특성에 관한 실험적 연구)

  • Sohn, Dong-Jin;Baek, Chang-Hyun;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.273-280
    • /
    • 2011
  • In this study, the steady state performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, compressor frequency, EEV opening, and water mass flow rate. Transient state performance tests were also conducted to investigate major system effects associated with the interaction between the $CO_2$ heat pump water heater and the water tank. Optimum refrigerant charge amount for the system was 1600 g. At compressor frequencies of 50 Hz and 60 Hz, water mass flow rates of 95 kg/h and 105 kg/h, and EEV opening of 8% and 16%, the water heating temperatures were $65^{\circ}C$ and $68^{\circ}C$ and COPs were 3.0 and 2.8, respectively. In the transient condition, the instantaneous COP decreased with an increase in the inlet water temperature.

Investigation of Standard Error Range of Non-Contact Thermometer by Environment (외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정)

  • Kim, Jeongeun;Park, Sangwoong;Choi, Heakyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

Temperature Monitoring of Vegetation Models for the Extensive Green Roof (관리조방형 옥상녹화의 식재모델별 표면온도 모니터링)

  • Youn, Hee-Jung;Jang, Seong-Wan;Lee, Eun-Heui
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.89-96
    • /
    • 2013
  • Green roofs can reduce surface water runoff, provide a habitat for wildlife moderate the urban heat island effect, improve building insulation and energy efficiency, improve the air quality, create aesthetic and amenity value, and preserve the roof's waterproofing. Green roofs are mainly divided into three types : intensive, simple-intensive, and extensive. Especially, extensive roof environment is a harsh one for plant growth; limited water availability, wide temperature fluctuations, high exposure to wind and solar radiation create highly stressed environment. This study, aimed at extensive green roof, was carried out on the rooftop of the library at Seoul Women's Univ. from October to November, 2012 and from March to August, 2013. To suggest the most effective vegetation model for biodiversity and heat island mitigation, surface temperatures were monitored by each vegetation model. We found that herbaceous plants of Aster sphathulifolius, Aceriphyllum rossii and Belamcanda chinensis, shrub of Syringa patula 'Miss Kim', Thymus quinquecostatus var. japonica, Sedum species can mixing each other. Among them, the vegetation models including Sedum takesimense, Aster sphathulifolius, Thymus quinquecostatus var. japonica was more effective on the surface temperature mitigation, because the species have the tolerance and high ratio of covering, and also in water. Especially, in the treatment of bark mulching, they helped to increase the temperature of vegetation models. In the case of summer, temperature mitigation of vegetation models were no significant difference among vegetation types. Compared to surface temperature of June, July and August were apparent impact of temperature mitigation, it shows that temperature mitigation are strongly influenced by substrate water content.

Investigation on Minimum Film Boiling Point of Highly Heated Vertical Metal Rod in Aqueous Surfactant Solution (계면활성제 수용액 내 고온 수직 금속봉의 최소막비등점에 대한 연구)

  • Lee, Chi Young;Kim, Jae Han
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.9
    • /
    • pp.597-603
    • /
    • 2017
  • In this study, experiments were conducted on the MFB(minimum film boiling) point of highly heated vertical metal rod quenched in aqueous surfactant solution at various temperature conditions. The aqueous Triton X-100 solution(100 wppm) and pure water were used as the liquid pool. Their temperatures ranged from $77^{\circ}C$ to $100^{\circ}C$. A stainless steel vertical rod of initial center temperature of $500^{\circ}C$ was used as a test specimen. In both liquid pools, as the liquid temperature decreased, the time to reach the MFB point decreased with a parallel increase in the temperature and heat flux of the MFB point. However, over the whole present temperature range, in the aqueous Triton X-100 solution, the time to reach the MFB point was longer, while the temperature and heat flux of the MFB point were reduced when compared with pure water. Based on the present experimental data, this study proposed the empirical correlations to predict the MFB temperature of a high temperature vertical metal rod in pure water and in aqueous Triton X-100 solution.

Experimental Investigation on the Enhancement of Gas Hydrate Formation for tile Solid Transportation of Natural Gas (천연가스 고체화 수송을 위한 가스 하이드레이트 생성촉진에 대한 실험적 연구)

  • Kim Nam-Jin
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.94-101
    • /
    • 2006
  • [ $1m^3$ ] solid hydrate contains up to $200m^3$ of natural gas, depending on pressure and temperature. Such large volume of natural gas hydrate can be utilized to store and transport large quantity of natural gas in a stable condition. So, in the present investigation, experiments carried out for the formation of natural gas hydrate governed by pressure, temperature, and gas compositions, etc.. The results show that the equilibrium pressure of structure II natural gas hydrate) is approximately 65% lower and the solubility is approximately three times higher than structure I methane hydrate). Also, the subcooling conditions of the structure I and II must be above 9K and 11K in order to form hydrate rapidly regardless of gas components, but the pressure increase is more advantageous than the temperature decrease in order to increase the gas consumption. And utilizing nozzles for spraying water in the form of droplets into the natural gas dramatically reduces the hydrate formation time and increases its solubility at the same time.

  • PDF

Relative Viscosity of Emulsions in Simple Shear Flow: Temperature, Shear Rate, and Interfacial Tension Dependence (전단유동에서 온도, 전단속도, 계면장력 변화에 따른 에멀전의 유변학적 특성)

  • Choi, Se Bin;Lee, Joon Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.8
    • /
    • pp.677-682
    • /
    • 2015
  • We simulate an emulsion system under simple shear rates to analyze its rheological characteristics using the lattice Boltzmann method (LBM). We calculate the relative viscosity of an emulsion under a simple shear flow along with changes in temperature, shear rate, and surfactant concentration. The relative viscosity of emulsions decreased with an increase in temperature. We observed the shear-thinning phenomena, which is responsible for the inverse proportion between the shear rate and viscosity. An increase in the interfacial tension caused a decrease in the relative viscosity of the decane-in-water emulsion because the increased deformation caused by the decreased interfacial tension significantly influenced the wall shear stress.