• Title/Summary/Keyword: water sampler

검색결과 139건 처리시간 0.024초

Aerosol Deposition and Behavior on Leaves in Cool-temperate Deciduous Forests. Part 2: Characteristics of Fog Water Chemistry and Fog Deposition in Northern Japan

  • Yamaguchi, Takashi;Noguchi, Izumi;Watanabe, Yoko;Katata, Genki;Sato, Haruna;Hara, Hiroshi
    • Asian Journal of Atmospheric Environment
    • /
    • 제7권1호
    • /
    • pp.8-16
    • /
    • 2013
  • The fog water chemistry and deposition in northern Japan were investigated by fog water and throughfall measurements in 2010. Fog water was sampled weekly by an active-string fog sampler at Lake Mashu from May to November. Throughfall measurements were conducted using rain gauges under three deciduous trees along the somma of the lake from August to October. The mean fog deposition rate (flux) was calculated using throughfall data to estimate the total fog water deposition amount for the entire sampling period. $NH_4{^+}$ and $SO{_4}^{2-}$ were the most abundant cation and anion, respectively, in the fog water samples. A mean pH of 5.08 in the fog water, which is higher than those in rural areas in Japan, was observed. The [$NH_4{^+}$]/[$SO{_4}^{2-}$] equivalent ratio in fog water was larger than 1.0 throughout the study period, indicating that $NH_3$ gas was the primary neutralizing agent for fog water acidity. The mean rate and total amount of fog water deposition were estimated as 0.15 mm $h^{-1}$ and 164 mm, respectively. The amounts of nitrogen and sulfate deposition via fog water deposition were corresponded to those reported values of the annual deposition amounts via rainfall.

Development of a Time-selective Self-triggering Water Sampler and Its Application to In-situ Calibration of a Turbidity Sensor

  • Jin, Jae-Youll;Hwang, Keun-Choon;Park, Jin-Soon;Yum, Ki-Dai;Oh, Jae-Kyung
    • Journal of the korean society of oceanography
    • /
    • 제34권4호
    • /
    • pp.200-206
    • /
    • 1999
  • Seawater sampling is the primary task for the study of the marine environmental parameters that require shipboard or laboratory experiments for their analyses, and is also required for the calibration of some instruments for in situ measurement. A new automatic bottle (AUTTLE) is developed for seawater sampling at any desired time and water depth by self-triggering. Both any type of single or assembled mooring for 15 days and manual actuation by using a remote messenger as existing instantaneous single point water samplers are possible. Its sampling capacity and the resolution of time setting are 2 liters and 1 second, respectively. The result of a field experiment with an optical backscattering sensor (OBS) and a total of 14 AUTTLES for the in situ calibration of the OBS shows that the AUTTLE must improve our understanding on the behavior of the sand/mud mixtures in the environments with high waves and strong tides. The AUTTLE will serve as a valuable instrument in the various fields of oceanography, especially where synchronized seawater sampling at several sites is required and/or the information in storm period is important.

  • PDF

PILS-TOC 및 GC/MS-TD를 이용한 서울시 대기 중 초미세먼지(PM2.5) 유기탄소의 특성 분석 (Characteristics of PM2.5 Carbonaceous Aerosol using PILS-TOC and GC/MS-TD in Seoul)

  • 박다정;안준영;신혜정;배민석
    • 한국대기환경학회지
    • /
    • 제30권5호
    • /
    • pp.461-476
    • /
    • 2014
  • Continuous Water-Soluble Organic Carbons (WSOC) by the Particle Into Liquid Sampler - Total Organic Carbon (PILS-TOC) analyzer were measured at the Seoul intensive monitoring site from June 17 through July 5 in 2014. In addition, the 24 hour integrated PM2.5 collected by Teflon and Quartz filters were analyzed for water soluble ions by Ion chromatography (IC), WSOC by TOC from water extracts, organic carbon (OC), elemental carbon (EC) by carbon analyzer using the thermal optical transmittance (TOT) method, and mass fragment ions (m/z) related to alkanes and PAHs (Poly Aromatic Hydrocarbons) by Gas Chromatography-Mass Spectrometer-Thermal Desorption (GC/MS-TD). Based on the statistical analysis, four different Carbonaceous Thermal Distributions (CTDs) from OCEC thermal-gram were identified. This study discusses the primary and secondary sources of WSOC based on the Classified CTD, organic mass fragments, and diurnal patterns of WSOC. The results provide knowledge regarding the origins of WSOC and their behaviors.

대청호 추소리 수역의 퇴적물이 조류 성장에 미치는 영향 (Effects of Sediments on the Growth of Algae at Chusori Area in Daechung Reservoir)

  • 오경희;김용준;조영철
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.533-542
    • /
    • 2015
  • In order to investigate the effect of internal loading from sediment on algal blooming at Chusori area in Daechung Reservoir, the amount and contamination level of sediment and the release rate of total phosphorus were analyzed. The sedimentary layer was consisted with two layers, and the average depth of upper and lower ones were 0.35 and 1.44 m, respectively. The fraction of inorganic phosphorus in the sediment was higher than that of organic phosphorus, and the fractions of phosphorus which responsible for internal loading were very high as in the range of 72.7 and 80.2% of inorganic phosphorus. The C/N ratio of sediment taken with core sampler indicated the organic compounds are originated from settled algae from water body. The average release rate of total phosphorus from sediment was $6.74({\pm}0.50)mg/m^2/day$. These results indicated that the internal loading from sediment contributes the excessive algal growth at Churosi area, and the countermeasures to improve the quality of sediments are required to manage algal blooming in Daechung Reservoir.

2006~2007년 천안시 대기 에어로졸의 입경별 농도 및 이온성분 특성 (Size-segregated mass and ion concentrations of atmospheric aerosols in Cheonan City between 2006 and 2007)

  • 이형배;오세원
    • 한국산학기술학회논문지
    • /
    • 제9권5호
    • /
    • pp.1349-1353
    • /
    • 2008
  • 충청남도, 천안시 대기 에어로졸의 입경별 농도 및 이온성분 특성을 분석하고자, 2006년 3월부터 2007년 4월까지 천안시 상명대학교에서 Cascade Impactor를 장착한 High Volume Air Sampler를 이용하여 대기 시료를 채취 분석하였다. 입경별 에어로졸의 일평균농도는 TSP, PM10, PM2.5, PM1이 각각 61.7, 55.2, 43.7, $33.2{\mu}g/m^3$였으며, 직경이 $1{\sim}3{\mu}m$인 영역을 경계로 조대영역과 미세영역으로 나누어지는 전형적인 도심지 특성을 나타냈다. 이 중 미세영역입자인 PM2.5이 전체 에어로졸의 70.8%를 차지하였다. 이들 에어로졸 입자의 성분 분석 결과 양이온은 ${NH_{4}}^+$, $Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$이, 음이온은 ${SO_{4}}^{2-}$, ${NO_{3}}^-$, $Cl^-$가 주요 성분이었으며, 이들 수용성 이온이 차지하는 비율은 조대입자에서 37.4%, 미세입자에서 46.2%였다.

대기입자의 원소성분 배출특성연구를 위한 반-연속식 입자채취시스템 적용 (Application of Semi-continuous Ambient Aerosol Collection System for Elemental Analysis)

  • 박승식;고재민;이동수
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.39-51
    • /
    • 2012
  • Aerosol slurry samples were collected in 60-min interval using Korean Semi-continuous Elements in Aerosol Sampler (KSEAS) between May 19 and June 6, 2010 at an urban site of Gwangju. The $PM_{2.5}$ samples were collected with a flow rate of 16.7 L/min and particles are grown by condensation of water vapor in a condenser maintained at ${\sim}5^{\circ}C$ after saturation by direct injection of steam. The resulting droplets are collected in a liquid slurry with a airdroplet separator. Concentrations of 16 elements (Al, Fe, Mn, Ca, K, Cu, Zn, Pb, Cd, Cr, Ti, V, Ni, Co, As, Se) in the collected slurry samples were determined off-line by ICP-MS. KSEAS sample analysis encompassed the sampling periods for which 24-hr average elemental species concentrations were calculated for comparison with those derived from 24-hr integrated filter samples. Relationship between elemental species measured by two methods indicated high correlation coefficients (r), mostly greater than r of 0.80. However, we note that concentrations of Al, K, Ca, Mn, and Fe, which are often associated with crustal elemental particles, in the KSEAS samples, were substantially lower (1.4~11 times) than those found in the typical filter-based samples. This discrepancy is probably due to difficulties in transferring insoluble dust particles to the collection vials in the KSEAS. Temporal profiles of elemental concentrations indicate that some transient events in their concentrations are observed over the sampling periods. For the elemental species studied, atmospheric concentrations during the transient events increased by factors of 4 in Mn~80 in Zn, compared to their background levels. Principle component analyses were applied to the hourly KSEAS data sets to identify sources affecting the concentrations of the metal constituents observed. In this study, we conclude that hourly measurements for particle-bound elemental constituents were extremely useful for revealing the short-term variability in their concentrations and developing insights into their sources.

고압 유체 시료의 pH 및 알칼리도 측정 방법 : 가상 시료를 활용한 실용성 평가 (Method for Measuring pH and Alkalinity of High-Pressure Fluid Samples : Evaluation through Artificial Samples)

  • 송민석;문수현;채기탁;방준환
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제29권1호
    • /
    • pp.1-9
    • /
    • 2024
  • As part of monitoring technology aimed at verifying the stability of CO2 geologic storage and mitigating concerns about leakage, a method for measuring the pH and alkalinity of high-pressure fluid samples was established to obtain practical technology. pH measurement for high-pressure samples utilized a high-pressure pH electrode, and alkalinity was measured using the Gran titration method for samples collected with a piston cylinder sampler (PCS). Experimental samples, referencing CO2-rich water and CO2 geologic storage studies, were prepared in the laboratory. The PCS controls the piston, preventing CO2 degassing and maintaining fluid pressure, allowing mixing with KOH to fix dissolved CO2. Results showed a 6.1% average error in high-pressure pH measurement. PCS use for sample collection maintained pressure, preventing CO2 degassing. However, PCS-collected sample alkalinity measurements had larger errors than non-PCS measurements, limiting PCS practicality in monitoring field settings. Nevertheless, PCS could find utility in preprocessing for carbon isotope analysis and other applications. This research not only contributes to the field of CCS monitoring but also suggests potential applications in studies related to natural analogs of CCS, CO2-rock interaction experiments, core flooding experiments, and beyond.

PM2.5 자동측정장비 비교 및 정도관리 방안 (Comparison of the Real-time Measurements for PM2.5 and Quality Control Method)

  • 박미경;박진수;조미라;이용환;김현재;오준;최진수;안준영;홍유덕
    • 한국대기환경학회지
    • /
    • 제33권6호
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).

Refined Exposure Assessment for Three Active Ingredients of Humidifier Disinfectants

  • Lee, Jong-Hyeon;Kang, Hyun-Joong;Seol, Hwi-Soo;Kim, Chan-Kook;Yoon, Seung-Ki;Gwack, Jin;Kim, Yong-Hwa;Kwon, Jung-Hwan
    • Environmental Engineering Research
    • /
    • 제18권4호
    • /
    • pp.253-257
    • /
    • 2013
  • Exposure assessment for three major active ingredients used for humidifier disinfectants, polyhexamethylene guanidine (PHMG), oligo(2-(2-ethoxy)ethoxyethyl guanidinium chloride (PGH), and 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT) mixture, was conducted in a bedroom using an air sampler for a refined risk assessment. The experimental site was selected to reflect consumer exposure conditions. Aerosols formed by a humidifier were sampled during 8 hr at 7.5 L/min. Absorbed PHMG and PGH by the sampler were quantified using a spectrophotometric method, and high performance liquid chromatography-ultraviolet detection was used for CMIT/MIT. Three exposure scenarios were assumed for adding humidifier disinfectants to the humidifier water at 1, 2, and 10 times the volume recommended by the product suppliers, and the humidifier was on at its maximum rate of producing aerosols in order to consider reasonable worst-cases. The sampled mass of PHMG and PGH ranged 200 to $2,800{\mu}g$ and 140 to $1,900{\mu}g$, respectively, under different exposure conditions, whereas the absorbed mass of CMIT/MIT was barely detected at the detection limit of 0.11/0.29 mg/L, only at 10 times the recommended level. The resulting risk quotients for PHMG and PGH ranged 1,400 to 20,000 and 1,000 to 13,000, indicating that health risks could be significant. For CMIT/MIT mixture, risk quotients were much smaller than estimated by assuming that they are conservative in the indoor environment, probably due to oxidative reactions. The refined exposure assessment presented here may provide a useful tool for assessing risks posed by active ingredients in spray-type biocidal products.

2016년 한국 경기도의 3월 황사기간 동안 부유세균 군집과 다양성에 대한 메타지노믹 분석 (Metagenomic Analysis of Airborne Bacteria Community and Diversity in Gyeonggi-do, Korea, during March 2016, Asian Dust Event)

  • 장준형;김지혜;배경선;김정명;이원석;정현미;박상정;서태근
    • 한국환경보건학회지
    • /
    • 제43권6호
    • /
    • pp.491-498
    • /
    • 2017
  • Objective: Bacterial abundance and community compositions have been examined in Asian dust events, clarifying their impacts on public health. This study aims to determine the bacterial community compositions and viable bacteria in Asian dust particles in the Asian dust or non-Asian dust event of March 2016. Methods: The dust samples were collected using the high volume air sampler or high volume cascade impactor, and bacterial 16S rRNA genes were amplified using PCR, followed by pyrosequencing. Bacterial diversity index, richness estimate and community composition in the particles were analyzed from the sequencing data using Mothur software. Results: The results showed that the diversity and richness during Asian dust events were higher than them in non-Asian dust events. The total bacterial community analysis showed that at the phylum Proteobacteria, Actinobacteria and Firmicutes were the most dominant of Asian dust events and non-Asian dust events. In addition, the bacterial colony counts were higher during Asian dust event, comparing with non-Asian dust event. Conclusions: This study showed that bacterial community and richness of Asian dust samples was more complex and higher than non-Asian dust samples in Gyeonggi-do, Korea, which could affect public health and environment. Thus, the continuous monitoring of Asian dust could be an alternative for managing airborne bacteria.