• Title/Summary/Keyword: water sampler

Search Result 139, Processing Time 0.023 seconds

Development of Automatic Water Sampler with Sensor for Practical Measurement (현장측정용 센서부착 자동채수기 개발)

  • Kim, Jin-Hyok;Han, Seong-Kuk;Lee, Jin-Pill;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.632-637
    • /
    • 2010
  • Considering the water quality regulation of total emission system which is enforced with hydro TMS and so on operating currently, automatic water sampler must be necessary in the viewpoint of national interest for conservation of water resources. This study aimed to develope automatic water sampler for the purpose of decreasing spends on foreign currency which is relied on import from abroad and upgrading the functional efficiency simultaneously. We have made an effort for developing results as follows with some cases. First, flow meter with a sensor equiped into automatic water sampler for field measurement which can perform linkage operation was developed. Second, remote-D/L system was developed which was able to monitor and store some transmitted data from practical measurement sensor. Also, automatic water sampler was developed in this research that operates in a sewage treatment plant, and finally, we confirmed that our system is able to apply to the field well.

Measurement of Dry Deposition Flux of Air Pollutants to the Waterbody (수체로의 대기오염물질 건식침적량 측정)

  • 김영성;진현철;김용표
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.421-426
    • /
    • 2004
  • Dry deposition fluxes of inorganic acidic species to the waterbody were measured by the dry deposition sampler (DDS). DDS was composed of three pans filled with pure water. An average concentration increase during the sampling time, after removing an abnormal value if existed, was considered as the input by deposition. Important operation parameters such as the amount of water used and sampling time were determined through a series of laboratory experiments. The deposition flux measured by DDS was compared with that by the water surface sampler developed by Yi et ai. (1997a,b).

Evaluation of Passive Sampler as a Useful Tool for Environmental Education (환경교육의 도구로서 간이 측정기의 활용에 관한 연구)

  • 전의찬;송민종
    • Hwankyungkyoyuk
    • /
    • v.11 no.2
    • /
    • pp.252-261
    • /
    • 1998
  • Since 1980's during which environmental pollution became serious enough to urge various types of environmental educations in many areas. But, most emphasis has been put on theoretical education. Even field education training mostly focused on water pollution. Therefore, simple air pollution monitoring system was needed for better field education in air pollution. In this study, we evaluated Passive Sampler as an useful tool for teaching air pollution in field. Students have found passive sampler very effective tool. Recent comparative study of auto-monitoring and passive sampler networks suggested a potential use of passive sampler as an useful tool for environmental education. In this study, the correlation between two sets of values appears very high judging from the regression slope of 0.92 and correlation coefficient of 0.91 However, inexpensive Passive sampler with easy-to-operate colorimeter, has not been used in environmental education partially because large scale fluctuation in time and space characteristic to air pollution has been overlooked so that the sampler has not been tested for an effective educational tool. Passive sampler certainly deserves further in depth research as an effective air monitoring system, and better attention to its usefulness to teach students and public.

  • PDF

New and Improved Time-selective Self-triggering Water Sampler: AUTTLE

  • Jin, Jae-Youll;Hwang, Kuen-Choon;Park, Jin-Soon;Eo, Young-Sang;Kim, Seong-Eun;Yum, Ki-Dai;Oh, Jae-Kyung
    • Ocean and Polar Research
    • /
    • v.22 no.2
    • /
    • pp.57-67
    • /
    • 2000
  • Time-selective self-triggering water sampler, AUTTLE developed by Jin et al. (1999) has been improved in order to prevent pre-deposition of suspended sediments (SS) before sampling. By using two solenoids, the improved sampler is able to be moored or deployed with inclination. Its position is changed to horizontal position by activating the first solenoid, and then the endcaps of the sampling bottle are closed by the second solenoid that is driven three times to minimize possible failure of sampling. An external control unit for setting sampling time has been also constructed. Additionally, the electric circuit housing of the sampler has been modified to be detached from the sampling bottle when operating manually. Its performance has been confirmed through flume tests and a field experiment. It will serve as a valuable tool in the various fields of oceanography and environmental engineering, especially where seawater sampling synchronized at several sites and/or the information in storm period is important.

  • PDF

Friable Test and Risk Assessment for Asbestos in Soils using the Releasable Asbestos Sampler (RAS) (석면 비산 장비를 이용한 토양 중 석면 비산 특성 및 위해성 평가)

  • Kim, In Ja;Kim, Jeong-Wook;Ryu, Hyun Sik;Jung, Myung Chae
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.5
    • /
    • pp.68-74
    • /
    • 2012
  • The objective of this study is to examine a releasable asbestos sampler developed for measuring friable asbestos from soil to air controlled by wind velocity and water contents. Asbestos contaminated soil with 3.75% at the Sinsuk-asbestos mine was sampled, air-dried and sieved to 100 mesh, then homogenized during 24 hours' agitation. Various wind velocities, 1 m/s, 2 m/s, 3 m/s, and 5 m/s, were applied to evaluate releasable characteristics of the releasable asbestos sampler. In addition, soils with 1.0%, 3.4%, 4.4%, 11.0%, 16.2%, and 20.0% of water contents were also examined the amount of friable asbestos by the releasable asbestos sampler. Collected soil and air samples were analyzed by polarized light microscopy (PLM) and phase contrast microscopy (PCM), respectively. Those contents were applied to calculate an excess life cancer risk (ELCR). This study also discussed the relationship with risk assessment by a weeding scenario of activity based sampling (ABS) and field applied releasable asbestos sampler. The result was shown that friability of asbestos in soil increased with wind velocity and decreased with water content. In comparison with ELCR results, over 10E-4 of cancer risk was found in condition on < 5% water content and > 3m/s wind velocity.

Development of a Groundwater Sampler and Test in a Well Affected by Seawater Intrusion (지하수 샘플러 개발 및 해수침투 관측정에서의 평가)

  • Lee, Bong-Joo;Moon, Sang-Ho;Kim, Gee-Pyo;Kim, Yong-Cheol;Kim, Yong-Je;Koh, Gi-Won
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.331-338
    • /
    • 2008
  • A new ground water sampler was developed and evaluated for target depth sampling under most rigorous field conditions. This new concept sampler comprises an air-cylinder, a hypodermic needle and a sampling bottle. Pressurized air or nitrogen gas can be used as a mechanical power source to operate the sampler. The air-cylinder is used to jab the hypodermic needle into the rubber cap of the sampling bottle. The hypodermic needle functions as a pathway to inject groundwater into the sampling bottle. Field test was conducted in a seawater intrusion monitoring well located at Handong district of Jeju Island. Water qualities in this well are periodically changed from the effects of sea water. Water sampling fir the same target depth in this well were tried at various times, and variations in electrical conductivity and pressure at the inside and outside of the sampler were measured using CTD divers. We found that the device could collect water samples only when it was actuated, and the pattern and range of variations in electrical conductivities and pressures measured at the inside and outside of the sampler were nearly identical. These results indicate that water samples using the sampler presented in this study represent correctly water qualities in which the samplings were made at a specific target depth in a well.

Application of Passive Sampling in Marine Environment: 2. Modified Method for Shortening of Deployment Time in a Field (해양환경에서의 수동형채집기(Passive Sampler)의 활용: 2. 현장노출시간 단축을 위한 개선법)

  • JANG, YU LEE;LEE, HYO JIN;JEONG, HAE JIN;KIM, GI BEUM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.2
    • /
    • pp.249-265
    • /
    • 2019
  • A passive sampler is one of the promising methods to easily and more accurately predict the free dissolved and bioavailable concentration ($C_{free}$) in seawater or pore water in sediments. In Europe and the United States, the use of passive samplers has been highly encouraged for more accurate marine environmental risk assessment. However, long deployment time in the field causes problems such as biofouling of the samplers, so there are few studies using passive samplers in Korea. Therefore, we review the principle and basic characteristics of the passive sampler for persistent organic pollutants, and introduce various improvement cases for the field applications of the passive sampler.

The geophysical survey in shallow water and transitional region

  • Ashida Yuzuru
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.1-15
    • /
    • 2002
  • In the present paper, the marine reflection seismic survey, the survey using Chirp sonar, the detail topographic survey by narrow multi-beam sounding machine, the sea bottom geological condition survey by side-scan sonar, the sea bottom sampling by core sampler and the positioning by DGPS as the geophysical survey in shallow and transitional region are introduced by placing emphasis on hardware configuration.

  • PDF

Atmospheric Dry Deposition Characteristics of Nitrogen-containing Compounds into Juam Reservoir (주암호에 대한 질소화합물의 대기건식침적 특성)

  • Cheong Jang-Pyo;Jang Young-Hoan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.657-666
    • /
    • 2005
  • The objectives of this study were to investigate atmospheric dry deposition of inorganic nitrogen-containing compounds to waterbody. Target waterbody is Juam reservoir functioning as one of the major water supply sources in Chollanamdo. Nitrate and ammonium dry deposition fluxes were directly measured using dry deposition plate (DDP) covered with greased strips and a water surface sampler (WSS). The daytime average $NO_{3}^{-}\;and\;NH_{4}^{+}$ fluxes measured with DDP and WSS were $1.7\∼2.6$ times higher than those at nighttime. The seasonal average flux of $NH_{4}^{+}$ showed the highest value in summer. The daytime and nighttime average dry deposition fluxes of particulate phase Nitogen-containing Compounds ($1.13,\;0.80\;mg/m^{2}$ day) were much higher than those of gas phase compounds ($0.50,\;0.24\;mg/m^{2}$ day).

Development and Evaluation of a Badge-type Passive Sampler for the Measurement of Short-term Nitrogen Dioxide in Ambient Air (대기 중 이산화질소의 단기 측정을 위한 뱃지형 passive sampler의 개발 및 평가)

  • Kim Sun Kyu;Yim Bong Been;Jung Eui Suk;Kim Sun Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.117-126
    • /
    • 2006
  • The purpose of this study is to develop a badge-type passive sampler for the measurement of short-term nitrogen dioxide and to evaluate its performance. The principle of the method is a colorimetric reaction of nitrogen dioxide with sulfanilic acid, N-1-naphthylethylendiamine, and phosphoric acid. First, it has been shown that the filter paper should be rinsed with ultrapure water and ultrasound, and then dried in a vacuumed desiccator. The concentration and volume of absorption reagent (triethanolamine) were $20\%$ and 100 ${\mu}L$, respectively. The extraction time was determined as 60 min. Second, duplicate measurements (n= 116) were carried out for evaluating the precision of the passive sampler. The relative error and the correlation coefficient between duplicates are $3.4\pm 3.0\%$ and 0.994, respectively. In addition, the $95\%$ confidence interval of intraclass correlation coefficient and the estimated value are 0.992$\sim$0.996 and 0.994, respectively. Third, a paired t-test was carried out for evaluating the accuracy of the passive sampler (n=40). In the result of the test, the $95\%$ confidence interval of the difference was -1.710 ppb <$\gamma$< 0.788 ppb. Finally, the average concentration of blanks, measurement detection limit, limit of detection, and limit of quantification are $2.4\pm 0.4$ ppb, 104 ppb, 3.8 ppb, and 7.0 ppb, respectively.