• Title/Summary/Keyword: water removal efficiency

Search Result 1,752, Processing Time 0.038 seconds

Water Treatment and Oxygen Transfer by Rotating Biological Contactor in Pilot-Scale Recirculating Aquaculture System (Pilot-scale 순환여과식 양식장에서 회전원판 반응기의 순환수 처리 및 산소전달)

  • Suh Kuen Hack;Kim Byong Jin;Lee Jung Hoon;Kim Yong Ha;Lee Seok Hee;Kim Sung Koo;Jo Jea Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.5
    • /
    • pp.469-475
    • /
    • 2002
  • The rotating biological contactor (RBC) was tested for treatment of aquacultural water in a pilot-scale recirculating aquaculture system. Performance of RBC on the treatment of nitrogen source such as total ammonia nitrogen (TAN), nitrite nitrogen and nitrate nitrogen and chemical oxygen demand (CODcr.) was evaluated. A system was stocked with nile tilapia at an initial rearing densities of $5\%$ and $7\%$ over 30 days. As increasing rearing density from $5\%$ to $7\%$, the TAN removal rates was increased from $39.4 g/m^3{\cdot}day$ to $86.0 g/m^3{\cdot}day$. But TAN removal efficiency was decreased from $24.5\%$ to $16.0\%$. The removal rate of $COD_Cr$ was higher than TAN. The RBC as an aerator was also evaluated for increasing dissolved oxygen concentration. For $5\%$ and $7\%$ of rearing density, the average aeration rate were $280 g/m^3{\cdot}day$ and $255 g/m^3{\cdot}day$, respectively.

Performance assessment of an urban stormwater infiltration trench considering facility maintenance (침투도랑 유지관리를 통한 도시 강우유출수 처리 성능 평가)

  • Reyes, N.J. D.G.;Geronimo, F.K.F.;Choi, H.S.;Kim, L.H.
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.424-431
    • /
    • 2018
  • Stormwater runoff containing considerable amounts of pollutants such as particulates, organics, nutrients, and heavy metals contaminate natural bodies of water. At present, best management practices (BMP) intended to reduce the volume and treat pollutants from stormwater runoff were devised to serve as cost-effective measures of stormwater management. However, improper design and lack of proper maintenance can lead to degradation of the facility, making it unable to perform its intended function. This study evaluated an infiltration trench (IT) that went through a series of maintenance operations. 41 monitored rainfall events from 2009 to 2016 were used to evaluate the pollutant removal capabilities of the IT. Assessment of the water quality and hydrological data revealed that the inflow volume was the most relative factor affecting the unit pollutant loads (UPL) entering the facility. Seasonal variations also affected the pollutant removal capabilities of the IT. During the summer season, the increased rainfall depths and runoff volumes diminished the pollutant removal efficiency (RE) of the facility due to increased volumes that washed off larger pollutant loads and caused the IT to overflow. Moreover, the system also exhibited reduced pollutant RE for the winter season due to frozen media layers and chemical-related mechanisms impacted by the low winter temperature. Maintenance operations also posed considerable effects of the performance of the IT. During the first two years of operation, the IT exhibited a decrease in pollutant RE due to aging and lack of proper maintenance. However, some events also showed reduced pollutant RE succeeding the maintenance as a result of disturbed sediments that were not removed from the geotextile. Ultimately, the presented effects of maintenance operations in relation to the pollutant RE of the system may lead to the optimization of maintenance schedules and procedures for BMP of same structure.

A Study on Coagulation and Ozone Treatment of Nonbiodegradable Substances in Landfill Leachate (생물학적 난분해성물질을 함유한 매립장 침출수의 응집 및 오존처리에 관한 연구)

  • Kim, Jong Shik;Choi, Joon Ho
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.330-335
    • /
    • 1998
  • The objectives of this study are summarized with two. The one is to remove of $COD_{Cr}$, color and turbidity with coagulation and ozonation in nonbiodegradable landfill leachate, the other is to compare of water qualities with pre-ozonation and post-ozonation. The results are summarized as follows ; 1) 90 minutes ozonation with $75mgO_3/min$($4.5gO_3/hr$) was conducted at pH 4,7, 10 to remove $COD_{Cr}$. Removal efficiencies were investigated with 48.2%, 52.6%, and 62.3% respectively. As increasing pH, $COD_{Cr}$ removal efficiencies were increased, it was considered that hydroxyl radical($OH{\cdot}$) which strongly oxdize and nonselectively react with organic compounds, was rapidly produced by ozone self-decomposition at high pH. 2) Alum, ferric chloride and ferrous sulfate were used for coagulation as inorganic coagulant. Ferric chloride was investigated with optimal coagulant, and it removed $COD_{Cr}$ about 12.0% at pH5 and dosage of $2,000m{\ell}/{\ell}$. Cation(C-101P), anion(A-601P) and nonion(SC-050) were tested to remove organic pollutants in landfill leachate. Cation(C-101P) was investigated with the most effective organic coagulant, and removal efficiency of $COD_{Cr}$ was 19.8% at pH5 and dosage of $100m{\ell}/{\ell}$. 3) Color and turbidity were removed up to 88.6%, 97.0% at pH10, when contacted 90 minutes with ozone, respectively. These removal efficiencies were much higher than those of $COD_{Cr}$ and $COD_{Mn}$. It was considered that ozone could oxdize the triggering materials of color and turbidity selectively and preferentially. 4) $COD_{Cr}$, color and turbidity were more effectively removed with pre-ozonation than post-ozonation about 8%, 3.5% and 1% respectively. These results were well corresponed with other's studies that pre-ozonation will increase the effect of coagulation.

  • PDF

Characterization and Feasibility Study of the Soil Washing Process Applying to the Soil Having High Uranium Concentration in Korea (우라늄 함량이 높은 국내 토양에 대한 토양학적 특성 규명 및 토양세척법의 적용성 평가)

  • Chang, See-Un;Lee, Min-Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.5
    • /
    • pp.8-19
    • /
    • 2008
  • The physicochemical properties of soils having high uranium content, located around Duckpyungri in Korea, were investigated and the lab scale soil washing experiments to remove uranium from the soil were preformed with several washing solutions and on various washing conditions. SPLP (Synthetic Precipitation Leaching Procedure), TCLP (Toxicity Characteristic Leaching Procedure), and SEP (Sequential Extraction Procedure) for the soil were conducted and the uranium concentration of the extracted solution in SPLP was higher than Drinking Water Limit of USEPA (30 ${\mu}g$/L), suggesting that the continuous dissolution of uranium from soil by the weak acid rain may generate the environmental pollution around the research area. For the soil washing experiments, the uranium removal efficiency of pH 1 solution for S2 soil was about 80 %, but dramatically decreased as pH of solution was > 2, suggesting that strong acidic solutions are available to remove uranium from the soil. For solutions with 0.1M of HCl and 0.05 M of ${H_2}{SO_4}$, their removal efficiencies at 1 : 1 of soil vs. washing solution ratio were higher than 70%, but the removal efficiencies of acetic acid, and EDTA were below 30%. At 1 : 3 of soil vs. solution, the uranium removal efficiencies of 0.1M HCl, 0.05 M ${H_2}{SO_4}$, and 0.5M citric acid solution increased to 88%, 100%, and 61% respectively. On appropriate washing conditions for S2 soil such as 1 : 3 ratio for the soil vs. solution ratio, 30 minute for washing time, and 2 times continuous washing, TOC (Total Organic Contents) and CEC (Cation Exchange Capacity) for S2 soil were measured before/after soil washing and their XRD (X-Ray Diffraction) and XRF (X-Ray Fluorescence) results were also compared to investigate the change of soil properties after soil washing. TOC and CEC decreased by 55% and 66%, compared to those initial values of S2 soil, suggesting that the soil reclaimant may need to improve the washed soils for the cultivated plants. Results of XRF and XRD showed that the structural change of soil after soil washing was insignificant and the washed soil will be partially used for the further purpose.

Comparison of Removal Efficiencies in Single and Duplex Ventilation Constructed Wetland Systems for Treating Domestic Sewage (단일 통풍형과 이중 통풍형 인공습지시스템의 하수처리 효율 비교)

  • Seo, Dong-Cheol;Lim, Seok-Cheon;Jo, In-Seong;Lee, Byeong-Ju;Lee, Hong-Jae;Kim, Sang-Don;Lee, Jun-Bae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.3
    • /
    • pp.258-265
    • /
    • 2009
  • To develop environmentally friendly constructed wetlands(CWs) for treating domestic sewage which was produced in farming and fishing village, the efficiency of water treatment at different ventilation systems in the vertical bed, depths of horizontal bed, and sewage loads was investigated. In the vertical bed, BOD and COD by duplex ventilation system were lower than those by single ventilation system. But T-N and T-P concentrations by both ventilation systems in the vertical bed were little different. In the horizontal bed, BOD, COD, T-N and T-P in 1.0 m and 1.3 m depths were little different. To reduce the CWs' area and to improve the pollutant removal efficiencies, the optimum depth of horizontal bed was 1.3 m. In single and duplex ventilation CWs, the removal rate of BOD, COD, SS, T-N and T-P decreased slightly with the sewage load increases. In same sewage load conditions, the removal rates of BOD, COD, SS, T-N and T-P by duplex ventilation CWs were higher than those by single ventilation CWs. In summary, to effectively treat domestic sewage from farming and fishing village, the optimum constructed wetlands would be the duplex ventilation CWs.

The Effect of Algae on Coagulation and Filteration of Water Treatment Process (정수처리과정중 응집및 여과에 미치는 조류의 영향)

  • Lim, Young-Sung;Song, Won-Seb;Cho, Ju-Sik;Lee, Hong-Jae;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • Seasonal variations of dominant algae species and the effects of these algae on coagulation and filteration of water treatment were investigated at Chilseo water treatment plant in downstream of Nakdong river from January in 1995 to Desember of 1998. The water quality of Nakdong river was found to be a hyper eutrophic state during the investigation periods. In the measurement, Chlorophyll-a contents ranged $20.7{\sim}180.9{\mu}g/l$ and total nitrogen contents(T-N) and total phosphorus contents(T-P) exceeded more than 3.4mg/l and 0.1mg/l, respectively. The changes in dominant algae species was in the order of Stepanodiscus sp., Asterionella sp., Melosira sp., Microcystis sp. and Synedra sp. from spring to winter. Microcystis sp. especially, was blooming during summer and Synedra sp. and Stepanodiscus sp. during winter. Although most diatomous algae appeared in the water treatment process caused filter clogging and reduced efficiency of coagulation and sedimentation, Synedra sp. and Stepanodiscus sp were revealed as the main trouble algae. Malfunction of water treatment process caused by Synedra sp. and Stepanodiscus sp. started at the algae concentrations of 800cells/ml and 1,820cells/ml, respectively. When chlorophyll-a content was $18.9{\mu}g/l$, the optimum amounts of coagulant were found to be 40mg/l of Alum and 16mg/l of PACS. Under condition of chlorophyll-a content of $154.1{\mu}g/l$, addition of Alum at the level of 75mg/l and PACS at the level of 35mg/l showed the lowest turibidity. The result indicates that increased amounts of the coagulants should be added for a better water treatment as chlorophyll-a contents increased. Addition of Alum at the amount of 60mg/l and 30mg/l of PACS removed Stepanodiscus sp. algae at the rate of 85% and 83%, respectively. In case of Synedra sp., 50mg/l of Alum and 25mg/l of PACS showed removal rates of 79% and 81%, respectively. Synedra sp. algae at the standing crops of 1,500cells/ml started filter clogging and a filtering process was completely inhibited after 8 hours. At this situation the filter clogging by Synedra sp. algae occurred at the depth of 5cm from the top anthracite layer. On the other, other algae did filter clogging at the depth of 10cm.

  • PDF

Crystal Sinking Modeling for Designing Iodine Crystallizer in Thermochemical Sulfur-Iodine Hydrogen Production Process (열화학 황-요오드 수소 생산 공정의 요오드 결정화기 설계를 위한 결정 침강 모델링)

  • Park, Byung Heung;Jeong, Seong-Uk;Kang, Jeong Won
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.768-774
    • /
    • 2014
  • SI process is a thermochemical process producing hydrogen by decomposing water while recycling sulfur and iodine. Various technologies have been developed to improve the efficiency on Section III of SI process, where iodine is separated and recycled. EED(electro-electrodialysis) could increase the efficiency of Section III without additional chemical compounds but a substantial amount of $I_2$ from a process stream is loaded on EED. In order to reduce the load, a crystallization technology prior to EED is considered as an $I_2$ removal process. In this work, $I_2$ particle sinking behavior was modeled to secure basic data for designing an $I_2$ crystallizer applied to $I_2$-saturated $HI_x$ solutions. The composition of $HI_x$ solution was determined by thermodynamic UVa model and correlation equations and pure properties were used to evaluate the solution properties. A multiphysics computational tool was utilized to calculate particle sinking velocity changes with respect to $I_2$ particle radius and temperature. The terminal velocity of an $I_2$ particle was estimated around 0.5 m/s under considered radius (1.0 to 2.5 mm) and temperature (10 to $50^{\circ}C$) ranges and it was analyzed that the velocity is more dependent on the solution density than the solution viscosity.

Purification of Animal Wastewater Using a Reed-Sand-Filter System;I. Retention Period and Seasonal Variation (갈대사상여과법(砂床濾過法)을 이용한 축산폐수정화(畜産廢水淨化);I. 처리일수(處理日數) 및 계절별(季節別) 변화(變化))

  • Lee, Deog-Bae;Kim, Jong-Gu;Kang, Jong-Goog;Kim, Sun-Kwan;So, Jae-Don;Rhee, Kyeong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.231-239
    • /
    • 1994
  • A reed-sand-filter system was used to purify swine wastewater economically. Reeds (Phragmites communis Trin) were planted on the sand / gravel bed of a 20/30cm layer depth. After the input of waste-water up to a depth of l0㎝, the effluent was monitored for pollutants on the 1st, 3rd, 5th and 7th day thereafter. As swine wastewater stayed longer, the pollutants in the effluent such as T-N, $PO_4^{3-}$, COD and BOD were removed more effectively. The sand-filter system with reeds showed a superior removal efficiency to that without reeds. Especially in summer, the former showed greater purification rates than the latter, being 30% greater in T-N, 37% in $PO_4^{3-}$, 42% in COD and 30% in suspended solids. The seasonal purification efficiency was in the decreasing order of July, October and April. Reeds took up 40.1g N, 10.8g $P_2O_5$, 38.9g $K_2O$, 2.8g CaO, 2.1g MgO per square meter of the above surface area.

  • PDF

Development of Microbial Augmentation for the Treatment of Recalcitrant Industrial Wastewater Containing Chlorinated Organic Compounds (유기염소계 난분해성 산업폐수의 처리를 위한 미생물제제의 개발)

  • Lee, Hyun Don;Im, Seong Won;Suh, Hyun-Hyo
    • Journal of Life Science
    • /
    • v.24 no.8
    • /
    • pp.887-894
    • /
    • 2014
  • The screening of the microorganisms degrading chlorinated organic compounds such as PCP (pentachlorophenol) and TCE (trichloroethylene) was conducted with soil and industrial wastewater contaminated with various chlorinated organic compounds. Isolates (GP5, GP19) capable of degrading PCP and isolates (GA6, GA15) capable of degrading TCE were identified as Acetobactor sp., Pseudomonas sp., Arthrobacer sp., Xanthomonas sp. and named Acetobacter sp. GP5, Pseudomonas sp. GP19, Arthrobacer sp. GA6 and Xanthomoas sp. GA15, respectively. The microbial augmentation, OC17 formulated with the mixture of bacteria including isolates (4 strains) degrading chlorinated organic compounds and isolates (Acinetobacter sp. KN11, Neisseria sp. GN13) degrading aromatic hydrocarbons. Characteristics of microbial augmentation OC-17 showed cell mass of $2.8{\times}10^9CFU/g$, bulk density of $0.299g/cm^3$ and water content of 26.8%. In the experiment with an artificial wastewater containing PCP (500 mg/l), degradation efficiency of the microbial augmentation OC17 was 87% during incubation of 65 hours. The degradation efficiency of TCE (300 uM) by microbial augmentation OC17 was 90% during incubation of 50 hours. In a continuous culture experiment, analysis of the biodegradation of organic compounds by microbial augmentation OC17 in industry wastewater containing chlorinated hydrocarbons showed that the removal rate of COD was 91% during incubation of 10 days. These results indicate that it is possible to apply the microbial augmentation OC17 to industrial wastewaters containing chlorinated organic compounds.

Current Status and Utilization Technology of End-of-Life Photovoltaic Modules (태양광 폐 모듈의 처리현황 및 실용화 기술)

  • Cho, Jai Young;Park, Areum;Yun, Hyun Mok;Jun, Yun-Su;Kim, Joon Soo
    • Resources Recycling
    • /
    • v.29 no.4
    • /
    • pp.15-30
    • /
    • 2020
  • Recently, it is increasing a amount of installed solar-cell rapidly, and end-of-life photovoltaic(ELP) modules are generated in according to the reduction of cell efficiency largely. Recycling of ELP modules are begun at an advanced nation already, but there are bring about environmental contamination and resource recovery problems owing to not treated ELP modules because of economic cost completely. First of all, there were researched basic study for treatment conditions of used solar cell inspection, dismantling of aluminum frame, crushing / grinding & separation of tempered glass, removal of back sheet & EVA film, leaching & precipitation recovery of valuable metals and treatment of waste water. Therefore, we establish optimum conditions through carried out of designed apparatus, installation of equipment, test operation & trouble shooting in scale of 1ton/day pilot plant test. Following to economic review, it does have the economic efficiency until to the case of tempered glass recovery, but does not have the economic value in case of total processes until to recover the valuable metals. However, there are guaranteed economic value if we are gained a large amount of the expenses through EPR supported system. It was confirmed the commercialized possibility of ELP modules recycling if there were established on the collecting ELP modules, reusing criteria, economical technology, enactment of directives and enforcement of EPR supported system efficiently.