• 제목/요약/키워드: water reducer

검색결과 53건 처리시간 0.02초

저점도형 고성능 감수제가 다양한 혼화재 종류 및 치환량 조건에서 고성능 시멘트 페이스트의 레올로지 성능에 미치는 영향 분석 (Analysis of the influence of low viscosity typed high range water reducer on rheological properties high performance cement paste depending on SCM types and contents)

  • 전종운;손배근;이향선;한동엽
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.46-47
    • /
    • 2018
  • High performance concrete with low water-to-cement ratio has been widely used with increased demand of high rising buildings and huge scaled structures. Additionally, for high performance concrete, various SCMs are replaced to improve its performance from fresh state to hardened state. With the drawback of increased viscosity of the concrete mixture for high performance concrete, low-viscosity typed high range water reducer is the relatively new admixture. Therefore, as a goal of the research, under using various SCMs with wide range of content, the performance of low-viscosity typed high range water reducer was evaluated. Especially, in this research, the influence of low-viscosity typed high range water reducer on rheological properties including plastic viscosity and yield stress were assessed. As a result of the research, it is expected to provide a fundamental information of low -viscosity typed high ranged water reducer on high performance concrete with various conditions of SCMs.

  • PDF

ESW형 해수여과장치의 구동 기어감속기에 대한 내진해석 (Seismic Analysis for Driving Gear Reducer of ESW Traveling Sea Water Screen)

  • 김창원;이영신;김흥태;김지원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.731-736
    • /
    • 2011
  • In this study, the safety of the driving gear reducer of ESW traveling sea water screen was evaluated through seismic analysis. Mode analysis of gear reducer was performed for reliability of analysis. Seismic analysis was performed in Operating Basis Earthquake(OBE) and Safe Shutdown Earthquake(SSE), which was applied as design condition using Floor Respnse Spectrum(FRS). The maxsimum displacement of gear reducer under OBE and SSE were 0.0137 mm and 0.0241 mm, respectively. The maximum stress of gear reducer under OBE and SSE were 2.42 MPa and 4.36 MPa, respectively.

  • PDF

ESW형 해수여과장치의 구동 기어감속기에 대한 내진해석 (A Seismic Analysis for Driving Gear Reducer of ESW Traveling Sea Water Screen)

  • 김창원;이영신;김흥태;김지원
    • 한국소음진동공학회논문집
    • /
    • 제22권7호
    • /
    • pp.599-604
    • /
    • 2012
  • In this study, the safety of the driving gear reducer of ESW(essential service water) traveling sea water screen was evaluated through seismic analysis. Mode analysis of gear reducer was performed for reliability of analysis. Seismic analysis was performed in operating basis earthquake(OBE) and safe shutdown earthquake(SSE), which were applied as design condition using floor response spectrum( FRS). The maximum strain of gear reducer under OBE and SSE were 20.4 ${\mu}$ and 33.6 ${\mu}$, respectively. The maximum stresses were 2.42 MPa under OBE condition and 4.36 MPa under SSE condition, which were smaller than the allowable strength of material.

The Effect of Chemical Admixtures on Removal of Scattered Dust

  • Son, Ho Jeong;An, Jung Min;Chung, Chul-Woo;Lee, Jae-Yong
    • 한국건축시공학회지
    • /
    • 제13권6호
    • /
    • pp.594-601
    • /
    • 2013
  • One of the important problems associated with building demolition is the dust generated during the work. The only way to reduce the demolition dust is to use a dust net during water spraying. However, it is difficult to supply the necessary amount of water to remove demolition dust, thus making it difficult to apply this method on a demolition site. This work attempted to find an alternative approach to dust removal by incorporating surfactant and high range AE water reducer in the water being sprayed. Through the experiment, it was found that the addition of surfactant did not contribute to the removal of demolition dust. However, the use of high range AE water reducer showed better performance than spraying plain water, indicating that some amount of demolition dust had been adsorbed on the high range AE water reducer.

일반강도 콘크리트의 효과적인 유동성 증진 및 품질안정성 확보를 위한 감수제 성능에 대한 연구 (Study on Water Reducer Performance for Efficient Fluidity Development and Securing Robustness of Normal Strength Range Concrete)

  • 손배근;한동엽
    • 한국건축시공학회지
    • /
    • 제17권5호
    • /
    • pp.429-435
    • /
    • 2017
  • 본 연구의 목적은 일반강도 콘크리트 배합에 있어서 다양한 감수제에 따른 유동성과 품질 안정성을 평가하는 데에 있다. 감수제의 사용은 골재 품질이 저하되는 최근의 상황에서 피할 수 없지만 적절한 성능의 감수제 사용이 중요하다. 이에 본 연구에서는 일반강도 수준의 모르타르에 대하여 세 가지 종류의 감수제에 대하여 유동성 증진성능과 더불어 품질안정성을 레올로지적으로 평가하였다. 또한 콘크리트 배합에 있어서 단위수량 변화에 따른 유동성 변화를 측정하였으며 단위수량 저감효과와 그에 따른 제조원가를 산정하고 비교하였다. 본 연구를 통해 실제 현장에서 적절한 성능의 감수제를 선택할 수 있는 사례를 제공하고 이를 통해 경제적이고 효과적으로 유동성을 발휘하며 안정적인 품질을 확보할 수 있는 환경 마련에 기여하고자 한다.

Concentric Reducer와 Eccentric Reducer를 사용한 EMP 차폐 100dB급 급수관의 유동특성 평가 (Evaluation of Flow Characteristics in Water Supply Pipes Shielding Electromagnetic Pulse of 100 dB with Concentric and Eccentric Reducers)

  • 방승기;안혜린
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2017
  • In this paper, the flow characteristics of water in the water supply pipes of a WBC array were evaluated. We simulated the flow velocities and pressures for a standard pipe, an expansion pipe with a concentric reducer, and an expansion pipe with an eccentric reducer using computational fluid dynamics. In the case of the standard pipe, when the inlet flow velocities were 0.5 m/s and 2.0 m/s, the maximum flow velocities at the center of the WBC array were 0.54 m/s and 2.74 m/s, respectively, which were the greatest values among those of all the pipe models considered. In the case of the expansion pipe, the maximum flow velocities at the center of the WBC array were almost the same under the same conditions regardless of the type of reducer. The pressure losses in the pipe due to the concentric and eccentric reducers were found to be (165.09 ${\times}$ inlet $velocity^{1.6677}$) and (210.98 ${\times}$ inlet $velocity^{1.6478}$), respectively. The coefficient of determination at this time was greater than 0.99 and was the same for both the models. As a simulation result, it was found that in order to reduce the pressure loss when pipe with WBC array is connected with a conventional pipe, diameter of the pipe with WBC array at that section should be enlarged by one step, and then connected to the conventional pipe with a concentric reducer.

고성능감수제를 혼입한 갯벌모르타르의 역학적 특성에 대한 실험적 연구 (A Experimental Study of Mechanical properties in mud flat mortar mixed with High-range Water reducer)

  • 이흥열;김희두;이지선;양성환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.115-116
    • /
    • 2015
  • Since concrete has evolved to the development of the quality and performance there currently being used civil engineering, as the most important material in the construction sector. But the discovery of alternative building materials and indiscriminate use is negligible. So that is the situation facing the shortage of natural aggregate. Accordingly, this study reviewed the mechanical properties by replacing the aggregate through the mud flat of eco-friendly materials and analyze the usability by adding a high-performance water reducer for promoting workability.

  • PDF

Isolation and Identification of an Anaerobic Dissimilatory Fe(III)-Reducing Bacterium, Shewanella putrefaciens IR-1

  • Hyun, Moon-Sik;Kim, Byung-Hong;Chang, In-Seop;Park, Hyung-Soo;Kim, Hyung-Joo;Kim, Gwang-Tae;Kim, Mi-a;Park, Doo-Hyun
    • Journal of Microbiology
    • /
    • 제37권4호
    • /
    • pp.206-212
    • /
    • 1999
  • In order to isolate a Fe(III)-reducer from the natural environment, soil samples were collected from various patty fields and enriched with ferric citrate as a source of Fe(III) under anaerobic condition. Since the enrichment culture was serially performed, the Fe(III)-reduction activity was serially diluted and cultivated on an agar plate containing lactate and ferric citrate in an anaerobic glove box. A Gram negative, motile, rod-shaped and facultative anaerobic Fe(III)-reducer was isolated based on its highest Fe(III)-reduction activity, Bacterial growth was coupled with oxidation of lactate to Fe(III)-reduction, but the isolate fermented pyruvate without Fe(III), The isolate reduced an insoluble ferric iron (FeOOH) as well as a soluble ferric iron (ferric citrate). Using the BBL crystal enteric/non-fermentor identification kit and 16S rDNA sequence analysis, the isolate was identified as Shewanella putrefaciens IR-1.

  • PDF

누유방지형 감속기의 구조적 안전성 및 토크효율 향상에 관한 연구 (A Study on Structural Safety and Advanced Efficiency for a Drywell Type Reducer)

  • 오상엽
    • 대한기계학회논문집A
    • /
    • 제35권11호
    • /
    • pp.1399-1406
    • /
    • 2011
  • 수처리 공정에는 반드시 교반기 전용 감속기가 사용된다. 본 연구에서는 사용 중의 누유를 방지하고 토크효율 향상을 위한 전용 누유방지형 감속기를 개발하였다. 설계 개선된 감속기 시제품을 개발하는데 있어서, CAD 및 CNC 고속가공기를 사용하여 실물모형(Mock up), 금형 등을 제작하였다. 특히 누유방지 구조인 감속기 시제품의 하부 하우징에 대한 구조적 안전성을 평가하고자 상용 유한요소 해석코드인 ALGOR 을 이용하였다. 해석 결과, 최대 von Mises 응력이 항복응력보다 낮은 123 N/$mm^2$ 으로 안전하였으며, 고유진동수는 650~700 Hz 이었다. 그리고 토크효율은 95.87%로서 이전 연구결과 (88.45%)에 비하여 약 8% 향상되었다. 소음 수준은 75 dB, 사용 중 누유 및 이상 소음은 발생하지 않았다. 따라서 항상된 감속기 시제품을 최적 설계하여 성공적으로 개발하였다.

혼화제를 사용한 공동주택 바닥마감 모르타르의 균열저감에 관한 연구 (A Study on the Crack Prevention of the Floor Surface Finishing Mortar adding Chemical Admixtures in Apartment Houses)

  • 이동운
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1541-1548
    • /
    • 2015
  • 본 연구에서는 공동주택 바닥미장 모르타르의 균열을 저감하기 위하여 균열 방지제, 고성능 감수제, 수지 등의 재료혼입에 따른 균열촉진실험을 실시하였다. 그 결과 고성능 감수제와 수지를 혼입한 시편이 균열방지제를 사용한 시편보다 균열수와 압축강도에서 더 우수한 결과를 나타내었다. 그리고 가장 높은 압축강도를 나타낸 시편이 상대적으로 매우 적은 균열을 나타냈으며, 가장 낮은 압축강도를 나타낸 시편에서 많은 균열을 관찰할 수 있었다. 그러므로 압축강도가 우수한 시편이 균열 저항성도 우수한 것으로 나타나 압축강도와 균열저항성은 비례하는 것으로 측정되었다. 모의부재 실험을 바탕으로 실제 아파트 현장에 적용된 배합 3의 장기 모니터링 결과, 장기 재령에서 균열발생이 전혀 관찰되지 않았다.