• Title/Summary/Keyword: water plugging

Search Result 48, Processing Time 0.023 seconds

A Study on the Formation of Hydrate Plugging due to water molecules in High Pressure and Low Temperature Gas Pipeline (고압$\cdot$저온 가스 배관에서 수분에 의한 하이드레이트 플러깅 형성)

  • Lee J. H.;Baek Y. S.;Sung W. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.38-45
    • /
    • 2002
  • Hydrates are solid cryctallines resembling ice in appearance, which are consist of a gas molecule surrounded by a cage of water molecules. Because of containning a large amount of methane, hydrates have been considered as a future energy resource. However, the formation of hydrates in the oil and gas industries has been known as a serious problem for a long time. The formation of hydrate in pipeline is common in seasonally cold or sub-sea environments with low temperatures and high pressures. Especially, hydrate plug formation becomes a real menace to flow assurance in inadequately protected transmission lines. This study was carried out for the purpose of understanding mechanism of hydrate plugging and examining formation conditions of hydrate in high pressure gas pipeline. In this study, we measured hydrate equilibrium conditions under the various flowing conditions with the methane. The results were presented both the plugging tendency and the effect of flowing velocity.

  • PDF

Reaction Phenomena of the Ferrite Steel by Water Leakage into Liquid Sodium (소듐분위기에서 물 누출로 인한 Ferrite Steel에서의 반응현상)

  • Jeong, Kyung-chai;Kim, Byung-ho;Kwon, Sang-woon;Kim, Kwang-rag;Hwang, Sung-tai
    • Applied Chemistry for Engineering
    • /
    • v.9 no.2
    • /
    • pp.268-272
    • /
    • 1998
  • Water leak phenomena in the liquid sodium which is a coolant of liquid metal reactor, were investigated by carrying out sodium-water reaction experiment. It was confirmed that sodium and water react each other by the analysis of material composition of aspecimen at the end of experiment. When steam of $100kg/cm^2$ was passed through the leak path of the specimen for 4 hours, reaction products from sodium-water reaction were observed on the leak site. However, re-opening phenomena were not observed at this condition. It was interpretted that the reaction product precipitated on leak path and thermal transient caused self-plugging and re-openning phenomena, respectively.

  • PDF

Study on Plugging Criteria for Thru-wall Axial Crack in Roll Transition Zone of Steam Generator Tube (증기발생기 전열관 확관천이부위 축방향 관통균열의 관막음 기준에 관한 연구)

  • Park, Myeong-Gyu;Kim, Yeong-Jong;Jeon, Jang-Hwan;Kim, Jong-Min;Park, Jun-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.9
    • /
    • pp.2894-2900
    • /
    • 1996
  • The stream generator tubes represent an integral part of a major barrier against the fission product release to the environment. So, the rupture of these tubes could permit flow of reactor coolant into the secondary system and injure the safety of reactor coolant system. Therefore, if the crack was detected during In-Service Inspection of tubes the cracked tube should be evaluated by the pulgging criteria and plugged or not. In this study, the fracture mechanics evaluation is carried out on the thru-wall axial crack due to Primary Water Stress Corrosion Cracking in the roll transition aone of steam generator tube to help the assurence the integrity of tubes and estabilish the plugging criteria. Due to the Inconel which is used as tube material is more ductile than others, the plastic instability repture theory was used to calculate the critical and allowable crack length. Based on Leak Before Break concept the leak rate for the critical crack length and the allowable leak rate are compared and the safety of tubes was given.

MF Membrane Application for Water Treatment in Japan

  • Okazaki, Minoru
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.80-93
    • /
    • 1995
  • Membrane Technology, which has been in use for over twenty five years, has established itself as one of the principle separation methods. With improved technology, Reverse Osmosis ("RO") has been applied to large volume water treatment facilities. UF and MF Membrane Technology has, up until recently, been applied to small scale water treatment facilities. The fouling of membrane has restricted the growth of Membrane Technology in Water Treatment. Membrane fouling compound found in water causes the loss of flux across the membrane by absorbing to membrane and plugging their pores. Various methods have been used in the reduction and prevention of membrane fouling. For RO, a conventional pre-treatment system removes the pollutants, preventing the function decline of RO membrane by keeping SDI < 4 as the standard condition of feed water. UF and MF Membrane Technology that must have pre-treatment function within itself, are required to keep its ability not to be influenced by fouling.y fouling.

  • PDF

A Study on The Optimization of Pre-treatment for the Brine Wastewater from the Epoxy-resin Process by the Coagulation and Sedimentation Reactions (에폭시수지 생산 공정에서 발생되는 brine 폐수의 전처리를 위한 응집 및 침전 반응의 최적화 연구)

  • Cho, Wook Sang;Lee, Eun Young;Kang, Seong Wook;Lee, Jang Su;Jin, Su Ik
    • Clean Technology
    • /
    • v.11 no.2
    • /
    • pp.57-67
    • /
    • 2005
  • Epoxy resins are produced by the dehydro condensated reaction with ECH (Epichlorohydrin) and BPA(Bisphenol-A) as raw reactants under sodium hydroxide(NaOH) as a catalyst, and from this reaction, salted water named of brine, which contains ECH derivatives in condition of emulsion as likely as glycidol and polymer resins, is produced as an undesired side product. This brine water is alkaline wastewater and causes process fouling problems by plugging and chemically depositing polymer particles on the surface of inner wall of reactors and pipes, and decreases the biodegradable efficiency in the wastewater process. In this study, the optimization of coagulation and sediment reactions, using inorganic and organic polymer coagulants, were performed to remove the causes occurring the process fouling phenomena. And also, based on this study, the methodologies applicable to the commercial processes including economical analysis were presented.

  • PDF

Response of Open-ended Pipe Pile Foundation at Offshore Sites to Seaquake Induced by the Vertical Seismic Excitation of the Seafloor (해저면의 수직 지진 진동에 의해 유발된 해진에 대한 해상 개단 강관 말뚝 기초의 거동)

  • 최용규;남문석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • During an earthquake, there are three main components of excitation : horizontal excitation of the ground, vertical excitation of the pile due to superstructure feedback produced by vertical excitation of the ground, and the seawater excitation induced by the vertical ground shaking, that is, "the seaquake." These excitations could have effects on the soil plugs in open-ended pie piles installed at offshore sites. In this study, seaquake excitation induced by the vertical ground shaking was simulated by pulsing the water pressure at the seabed. During a seaquake, due to the induced excess porewater pressure and pressure gradients in the soil, the capacity of open-ended pipe piles installed in a simulated sea depth of greate than 220 m was reduced serevely and the soil plugging resistance was degraded by more than 80% The soil plug was failed because of eh upward seepage forces that developed in the soil plug due to excess pore water pressure produced in the bottom of the soil plug during the seaquake, The compressive capacity of ar open-ended pile in a simulated sea depth of less than 220 m was reduced only by about 10% and the soil plug resistance was degraded by less than 5%.s than 5%.

  • PDF

Recycling of Wastepaper(IX)-Effects of KOCC Fines and Other Contamination on Condebelt Press Drying System- (고지재생연구(제 9보)-국산 골판지 고지 내의 미세분 및 이물질들이 Condebelt Press Drying System에 미치는 영향-)

  • 지경락;류정용;신종호;송봉근
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.1
    • /
    • pp.19-25
    • /
    • 2000
  • In Condebelt press drying system, the temperature difference between top and bottom plate of Condebelt transfers water to bottom side, Fine fibers, stickies , ink , and various inorganic materials are also migrated to the fine wire located at the bottom plate by highly pressurized moisture flow. As a result, the fine wire contaminated by plugging of these fine and sticky materials can cause many problems such as blistering or partial crushing of paper. The contaimination of fine wire leads to a deterioroated strength together with uneven physical properties of paper. In this paper, froth-flotatiion method, which is commonly used in the field of ONP recycling process, were adopted to separate the contaminants in KOCC as a new fiber fractionation method. Standard deviation of paper strength and brighteness decreased of Condebelt fine wire were measured to investigate the effect of contaminants removal . The standard deviations of paper strength obtained from the flotated accept were not dependent on the number of condebelt press drying . However, in the case of untreated KOCC, the standard deviations were increased as press drying repeated. This indicates that the contaminant gives uneven physical properties to the paper by wire plugging . Optical and SEM images clearly illustrate the effect of contaminants on the wire condition.

  • PDF

Method for Simultaneous Determination of Cyanotoxins in Water by LC-MS/MS (액체크로마토그래프/질량분석기를 이용한 수중 남조독소물질 동시분석법)

  • Kim, Jeong-Hee;Yun, Mi-Ae;Kim, Hak-Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.597-605
    • /
    • 2009
  • Algae bloom occurred in reservoir in summer can cause taste and odor in water and disturb the flocculation and sedimentation processes in water treatment plant and cause sand filter plugging. It was also reported that microcystins, anatoxin and saxitoxin released from cyanobacteria had acute toxic effects on liver and nervous system. For these reasons, many advanced countries inclusive of WHO set the guideline for these toxins and cyanotoxins have been managed with regular monitoring in Korea as well. However, complex sample preparation steps such as a solid phase extraction (SPE) and derivatization are required with an existing analysis method with HPLC. We needed to improve an analysis method for low extraction efficiency and long sample preparation time. In this study, we have established a new LC/MS/MS method which can simultaneously determine 6 cyanotoxins (Microcystins-LR, Microcystins-RR, Microcystins-YR, Anatoxin-a, Saxitoxin, Neosaxitoxin) with only simple filtration step. When $75{\mu}L$ filterated sample was injected onto the LC-MS/MS, the recovery ranged from 86% to 112% and the MDL was $0.025{\sim}0.581{\mu}g/L$. We can make the MDL be lower than the guideline ($1{\sim}3{\mu}g/L$) of advanced countries with simple preparation.

Experience in Visual Testing of the Main Feed Water Piping Weld for Hanul Unit 3 (한울 3호기 주급수 배관 용접부 육안검사 경험)

  • Yoon, Byung Sik;Moon, Gyoon Young;Kim, Yong Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.74-78
    • /
    • 2015
  • Nuclear power plant steam generator that is one of the main component has several thousands of thin tubes. And the steam generator tube is subject to damage because of the severe operation conditions such as the high temperature and pressure. Therefore periodic inspections are conducted to ensure the integrity of steam generator component. Hanul unit 3 also has been inspected in accordance with in-service inspection program and is scheduled to be replaced for exceeding the plugging rate which was recommended by manufacturer. During the steam generator replacement activity, we found several clustered porosity on inner surface of main feed water pipe. Additionally crack-like indications were found at weld interface between base material and weld of main feed water pipe. This paper describes the field experience and visual testing results for inner surface of main feed water pipes. The destructive test result had shown that these indications were porosities which were caused by manufacturing process not by operation service.

The Fuel Characteristics of Diesel by Water Contamination (수분오염에 따른 경유의 연료적 특성)

  • Lim, Young-Kwan;Won, Ki-Yoe;Kang, Byung-Seok;Park, So-Hwi;Park, Jang-Min;Kang, Dea-Hyuk
    • Tribology and Lubricants
    • /
    • v.36 no.6
    • /
    • pp.385-390
    • /
    • 2020
  • It rains heavily, such as long rain and typhoons, during a typical rainy season in Korea. In this season, several fuel contamination accidents by water and vehicular problems caused by water contaminated fuel occur. Many research groups have studied the effects of water contaminated fuel on vehicles and environment. However the characteristics of water contaminated fuel have not been studied. In this study, we prepared diesel samples with a constant ratio of water (0~30 volume %) using an emulsifier. Then, we analyzed these diesel samples for their representative fuel properties. In the analytical results, diesel with 30% water showed an increase in fuel properties such as density (823→883 kg/㎥), kinematic viscosity (2.601→6.345 ㎟/s), flash point (47→56℃), pour point (-22→2℃), CFPP (cold filter plugging point) (-17→20℃) and copper corrosion number (1a→2a). The low temperature characteristics, such as low pour point and CFPP, blocks the fuel filter in the cold season. In addition, water contaminated diesel decreases lubricity (190→410 ㎛) under high frequency reciprocating rig (HFRR) and derived cetane number (54.81→34.25). The low lubricity of fuel causes vehicle problem such as pump and injector damage owing to severe friction. In addition, the low cetane diesel fuel increases exhaust gases such as NOx and particulate matters (PM) owing to incomplete combustion. This study can be used to identify the problems caused by water contamination to vehicle and fuel facilities.