• 제목/요약/키워드: water plants

검색결과 3,527건 처리시간 0.029초

수생식물을 이용한 담수 순환여과식 양식용수내의 무기영양염 처리 효율 (Inorganic Nutrient Removal Efficiency of Aquatic Plants from Recirculating Aquaculture System)

  • 마진석;오승용;조재윤
    • 한국양식학회지
    • /
    • 제16권3호
    • /
    • pp.171-178
    • /
    • 2003
  • Inorganic nutrients such as nitrogen and phosphate compounds accumulate in recirculating aquaculture systems. These nutrients must be removed from the system before they affect pH and fish health. For this purpose, aquatic plants are a simple and inexpensive method of removal. There are four commonly used aquatic plants: Eichhornia crassipes (water hyacinth), Pistia stratiotes (water lettuce), Hygrophila angustifolia, and Hydrocotyle leucocephala in freshwater recirculating aquaculture systems in Korea, but their efficiencies are not known. Therefore, removal efficiencies of inorganic nutrients from a freshwater recirculating aquaculture water with four commonly used aquatic plants were tested. Removing efficiencies of TAN, N $O_2$$^{[-10]}$ -N, and N $O_3$$^{[-10]}$ -N of the plants in 210 L aquaria for 48-hour period were tested. The removing efficiencies of TAN, N $O_3$$^{[-10]}$ -N, and P $O_4$$^{3-}$-P of the two most effective plants, water hyacinth and water lettuce, were also tested in 690 L (surface area of 1.55 $m^2$) tanks under 2 different initial stocking densities, 4 kg and 6 kg, for 22 days. Proximate analysis major nutrients and N and P contents of the all plants were analyzed for calculating net removal weight of N and P by the plants. Water lettuce was the most effective for removing TAN, N $O_2$$^{[-10]}$ -N, and N $O_3$$^{[-10]}$ -N from the water for 48-hour period tested followed by water hyacinth and Hygrophila angustifolia. Water lettuce reduced TAN, N $O_2$$^{[-10]}$ -N, and N $O_3$$^{[-10]}$ -N concentration from 2.3 mg/L, 0.197 mg/L, and 21.4 mg/L to 0.4 mg/L, 0.024 mg/L and 17.4 mg/L, respectively while water hyacinth reduced them down to 0.6 mg/L, 0.029 mg/L and 17.9 mg/L, respectively. The concentrations of TAN, N $O_2$$^{[-10]}$ -N, and N $O_3$$^{[-10]}$ -N in Hydrocotyle leucocephala group were rather increased up to 3.7 mg/L, 5.7 mg/L and 48.2 mg/L, respectively. This is because the creeping stem of Hydrocotyle leucocephala had to be cut to meet stocking weight resulting in decaying of the stem in the aquaria during experiment. The net growth in weight of water hycinth and water lettuce of 4 kg each in the 1.55 $m^2$ tanks for 22 days were 9.768 kg and 10.803 kg respectively, and those at initial weight of 6 kg each were 8.393 kg and 9.433 kg, respectively. The reason of lower net growth in the later group was restricted growth space. Nitrogen and phosphorus contents in water hyacinth were 2.89% and 0.27%, and those in water lettuce were 3.87% and 0.36%, respectively. Average quantities of removed N and P from 1.55 $m^2$ tanks by water hyacinth for 22 days were 18.9 g and 1.75 g, while those by water lettuce were 36.8 g and 3.5 g, respectively. Therefore water lettuce showed much higher efficiencies for removing both N and P from recirculating aquaculture water than water hyacinth.

국내 정수장 고도정수처리 공정에서 공정별 처리효율 조사 (Investigation of Treatment Efficiency for Advanced Processes of Water Treatment Plants in Korea)

  • 문성민;최승일;손진식;윤제용
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.323-329
    • /
    • 2005
  • Advanced processes such as ozonation or activated carbon filtration (ACF) in water treatment plants have been used in Korea since 1994. At present, seventeen drinking water treatment plants are currently operating. This survey compares the treatment performance of advanced processes in eight plants which have comparable water quality data. The three parameters (DOC, $UV_{254}$, and $KMnO_4$ consumption) of water quality were selected as an indicator of treatment efficiency. The treatment efficiency of ozonation and ACF processes was found to vary with large deviations in each plant. Treatment efficiency of DOC, $UV_{254}$, and $KMnO_4$ consumption by post ozonation ranged from 3 to 11%, 6 to 33%, and 12 to 28% respectively. On the other hand, for ACF, treatment efficiency of DOC, $UV_{254}$, and $KMnO_4$ consumption ranged from 7 to 38%, 8 to 48%, and 16 to 66% respectively. These large deviations indicate the advanced processes of water treatment plants to be further optimized.

소수력 발전소의 무인화 구축 설계 (The Remote Control System Design of Small Hydropower Plants)

  • 이경배;김영태;백두현;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.950-952
    • /
    • 2004
  • The developments of small hydropower plants in korea have been delayed by rising construction cost/low feasibility, local people's disagreement even though the capacity of water resources are enough. However, the recent raising of electricity purchasing price, the government's enlarging plan of small hydropower plants caused the newly development to be accelerated. In this paper, the design of remote control of small hydropower plants are proposed for better economy and easy control. The operation and monitoring of power plants are planned based on One(1)-man control from the central control room of regional area water works/ operating station and engineering station multipurpose dam offices with the equipments of OS, RTU(PLC), KT leased lines, WMPS, CSU and etc.

  • PDF

Sap Temperature Distribution of the Xylem and Leaf Water Status of Apple Trees in Relation to Soil Oxygen Diffusion Rates

  • Ro, Hee-Myong
    • Journal of Applied Biological Chemistry
    • /
    • 제43권3호
    • /
    • pp.170-175
    • /
    • 2000
  • A pot-lysimeter experiment was conducted with 3-year-old 'Tsugaru' apple (Malus domestica Borkh) trees to examine the changes in oxygen diffusion rate (ODR) with lateral flow velocity of water through soil. The influence of lateral water flow velocity on water relations and elemental content in leaf, and sap temperature distribution patterns of the xylem of trees were also determined. Trees were grown under four soil water regimes: (1) fast laterally flowing (FWT, $2.50{\times}10^{-4}cm\;s^{-1}$), (2) slow laterally flowing (SWT, $0.25{\times}10^{-4}cm\;s^{-1}$), and (3) stagnant water table (WLT) at 60-cm, and (4) drip-irrigation at -40 kPa of soil matric potential as a control. The rate of $O_2$ diffusion converged near $2{\times}10^{-3}g\;m^{-2}\;min^{-1}$ for FWT and control soils, but decreased below $1{\times}10^{-3}g\;m^{-2}\;min^{-1}$ 40 days after treatment (DAT) for WLT soils. For SWT soils, however, the ODR at 15 cm below the soil surface was similar to that of control, but at 45 cm below the soil surface, ODR was similar to that of the WLT treatment. Leaf water potential of FWT and SWT plants was similar to that of control plants, but the values for SWT plants declined by 98 DAT. Leaf water potential of WLT plants decreased from -1.86 MPa (9 DAT) to -2.41 MPa (59 DAT) and finally down to -2.70 MPa. The sap temperature measured at 1100-hr was lowest at top and highest at bottom for FWT and control plants, but this pattern of SWT and WLT plants was disturbed from 29 DAT. However, for SWT plants, such thermal disturbance of sap temperature disappeared from 63 DAT.

  • PDF

Glomus 내생균근균(內生菌根菌) 접종(接種)이 수분(水分) 스트레스에 노출(露出)된 참싸리의 건조저항성(乾燥抵抗性) 및 생리적(生理的) 변화(變化)에 미치는 영향(影響) (Effects of Endomycorrhizal Glomus Inoculation on Drought Resistance and Physiological Changes of Lespedeza cyrtobotrya Seedlings Exposed to Water Stress)

  • 김효진;이경준;한심희
    • 한국환경복원기술학회지
    • /
    • 제5권2호
    • /
    • pp.53-62
    • /
    • 2002
  • The objectives of this study were to understand the tolerance mechanism of woody plants to water stress and tolerance changes in relation to mycorrhizal formation. Lespedeza cyrtobotrya Miq. commonly used for erosion control in slopes were raised from seeds and transplanted to 120 plastic pots. Sixty pots received the top soil of a Fraxinus americana forest, while remaining 60 pots received the autoclaved top soil. The forest soil contained 1,200 spores per 100g of arbuscular endomycorrhizal fungus, mostly Glomus sp. The plants were raised outside with regular supply of water and mineral nutrients. Two kinds of water deficit treatment and a control were started at the middle of July : cyclic water deficit treatment with 3 cycles of sequential water stress at the point of xylem water potential of about -0.6, -0.6, and -1.7 MPa and recovery, and non-cyclic water deficit treatment with single water stress at about -1.5 MPa. The non-stressed plants received plenty of water throughout the period. In late August the plants were harvested for measurements of dry weight, N, P, carbohydrate contents, net photosynthesis and superoxide dismutase(SOD) activities. Both cyclic and non-cyclic water deficit treatments reduced dry weight by 60% and 40%, respectively, and reduced nitrogen absorption, while increased SOD activities. Water-stressed plants also showed increased carbohydrate contents in the leaves and lowered stomatal conductance. Mycorrhizal inoculation resulted in an average of 40% infection of roots and 2-3 times increase in P absorption in water-stressed as well as non-stressed plants. Mycorrhizal formation also increased shoot-root ratio. The results that SOD activities of water-stressed plants with mycorrhizal infection were significantly lower than those of non-mycorrhizal plants suggest the possibility of improvement of water-stressed condition by mycorrhizal formation. It was concluded that endomycorrhizal formation increased tolerance of Lespedeza cyrtobotrya seedlings to water stress.

현장실험을 통한 수생식물의 수질정화 효과에 관한 연구 (A Study on the Water Quality Purification Effect of Aquatic Plants in field work)

  • 이종성;김기남
    • 한국환경과학회지
    • /
    • 제14권10호
    • /
    • pp.937-944
    • /
    • 2005
  • Presently, aquatic plants are used for the water purification in inland water. This study was carried out to investigate the water purification effect of aquatic plants, Oenanthe javanica and Typha angustata, The experiment was conducted in outdoor flowing water was conducted for ten days, Water quality was measured in terms of water temperature, COD(chemical oxygen demand), SS(suspended solids), Total N, Total P. The results of field experimentation showed that hydraulic retention time was the earliest in July and August 2003, and there were not any particular changes of monthly water temperature in inflow water and outflow water. As we look at the changes taken place in inflow water and outflow water throughout the whole experiment period, the change of water quality in summer was salient, especially SS removal ratio showed distinguished change as $25\%$, when the pebble filter and aquatic were attached to it. The removal rate of COD, total N total P were $14,7\%,\;8\%\;and\;9\%$, respectively. In relating the length of water extension to the change in water quality, the water quality tended to get lower generally in proportion to hydraulic retention time.

수생식물의 중금속 흡수능에 관한 연구 (Uptake Capacity of Heavy Metals by Water Plants)

  • 이종화;함용규;박종안
    • Environmental Analysis Health and Toxicology
    • /
    • 제11권3_4호
    • /
    • pp.23-32
    • /
    • 1996
  • In this study, we investgated the uptake capacity of several water plants for heavy metals (lead and cadmium) in soil of rivers where are adjacent to a industrial complex in Chun-An city and in A-San city. We also examined the deposition pattern of heavy metal in plants. The results are as follows: 1. The soil of river in Chun-An city was polluted more serious than that of A-San city. In Chun-An city, mean values of lead and cadmium contents in soil were 26.224 $\pm$ 28.037 $\mu$g/g, and 0.854 $\pm$ 1. 127 $\mu$g/g, respectively. 2. Water plants examined in this study were Slum suave KITAGAWA, Persicaria thunbergii H. GROSS, Phragmiles japonica STEUD, Echinochloa crus-galli var. frumentacea WIGHT and Persicaria hydropiper SPACH. Both metal contents of several water plants distributed in Chun-An city were higher than those in A-San city. In these plants, Slum suave showed the highest uptake capacity for lead and cadmium. The mean values of lead and cadmium contents in Slum suave were 40.957 $\pm$ 29.577 $\mu$g/g and 1. 930 $\pm$ 1. 076 $\mu$g/g, respectively. Persicaria thunbergii also showed a relatively high uptake capacity for both metal. 3. Correlation between metal contents in soil and water plants was high. In both cases of Sium suave and Persicaria thunbergii correlation coefficients were 0.605 and 0.549, respectively. 4. We analyzed lead and cadmium contents in root, stem and leaf of several water plants. Both metals were mostly deposited in root. Much of both metals were also deposited in leaf. From the results, we suggest that Slum suave KITAGAWA and Persicaria thunbegii H. GROSS can be used to reduce heavy metals from industrial waste water.

  • PDF

인공섬 수생식물 생육특성에 관한 연구 (A Study on the Growth Characteristics of Riparian Plants on the Artificial Floating Islands)

  • 김용규;구본학;안동만
    • 한국환경복원기술학회지
    • /
    • 제4권4호
    • /
    • pp.25-35
    • /
    • 2001
  • This study aims to find out the growth characteristics of riparian plants on the artificial floating islands (AFI). Three types of experiments were performed. The vegetation growth were compared by the plant-supporting materials; natural cotton mat, coir mat on the AFI or in the water, and natural soil at the waterfront. Major findings are; 1. The survival rate of riparian plants was 100% on both coir-mat and cotton-matislands, which implies that we may substitute cheaper cotton for expensive coir-mat. 2. Both natural cotton mat and coir mat were good for the growth of plants. Especially, the natural cotton mat was good for Sparganium stoloniferum and Miscanthus sacchariflorus, and the coir mat was good for Typha latifolia. 3. The growth rate of stem and root showed difference between the stem-removed plants and stem-remaining plants. As a whole, the growth rate of stem-removed plants was bigger than the one of stem-remaining plants. 4. The growth rate of plants showed difference between those grown on the AFI and those grown in the water. The growth rate of plant on the AFI was bigger than the one in the water. 5. The growth rate of plants on the AFI was bigger than the one on the natural soil at the waterfront.

  • PDF

Bacterial Community Structure Shifted by Geosmin in Granular Activated Carbon System of Water Treatment Plants

  • Pham, Ngoc Dung;Lee, Eun-Hee;Chae, Seon-Ha;Cho, Yongdeok;Shin, Hyejin;Son, Ahjeong
    • Journal of Microbiology and Biotechnology
    • /
    • 제26권1호
    • /
    • pp.99-109
    • /
    • 2016
  • We investigated the relation between the presence of geosmin in water and the bacterial community structure within the granular activated carbon (GAC) system of water treatment plants in South Korea. GAC samples were collected in May and August of 2014 at three water treatment plants (Sungnam, Koyang, and Yeoncho in Korea). Dissolved organic carbon and geosmin were analyzed before and after GAC treatment. Geosmin was found in raw water from Sungnam and Koyang water treatment plants but not in that from Yeoncho water treatment plant. Interestingly, but not surprisingly, the 16S rRNA clone library indicated that the bacterial communities from the Sungnam and Koyang GAC systems were closely related to geosmin-degrading bacteria. Based on the phylogenetic tree and multidimensional scaling plot, bacterial clones from GAC under the influence of geosmin were clustered with Variovorax paradoxus strain DB 9b and Comamonas sp. DB mg. In other words, the presence of geosmin in water might have inevitably contributed to the growth of geosmin degraders within the respective GAC system.

국내 정수장 정수 수질자료의 특성분석 (1994년-1998년까지 5년간 자료를 중심으로) (Investigating Water Quality Data of Finished Water in Domestic Water Treatment Plants (1994-1998))

  • 윤제용;조순행;김해심
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.431-443
    • /
    • 2000
  • Water quality data from water treatment plants in Korea during 1994-1998 were investigated to find out the characteristics of their non compliance. The number of plants surveyed were approximately 600 and the number of samples were over 30,000. Ten parameters of water quality selected in this study and their non compliance % (inside parenthesis) were as follows: Heterotrophic plate count (0.14%), Total coliforms (0.08%), $NH_3$-N (0.29%), $NO_3$-N (0.14%), THMs (0.02%), Turbidity (0.11%), Residual chlorine (5.5%), $KMnO_4$ consumption (0.04%), Hardness (0.03%), pH (0.07%). These levels of non compliance were compared to those obtained from WIDB (Water Industry Database, 1996) of American Water Works Association. This study strongly supported that small water plants (<10,000 tons/day) were more vulnerable in meeting the regulation criteria of many water quality parameters such as Heterotrophic plate count. Total coliforms, $NO_3$-N, THMs, Turbidity, Residual chlorine, $KMnO_1$ consumption, Hardness and pH. The $NH_3$-N concentration was especially high in winter and its violation was frequently found in the specific areas such as the downstream of major rivers. The average THMs concentration was surprisingly low, indicating $13{\mu}g/L$ which is 43% of US. Accordingly, these characteristics must be reflected in establishing the effective management of water quality policy of drinking water in Korea.

  • PDF