• 제목/요약/키워드: water phantom

검색결과 371건 처리시간 0.026초

Digital Spectrum 분석방법을 이용한 조직특성 변수에 관한 연구 (Ultrasonic Tissue Characterization by Digital Spectrum Analysis Technique)

  • 곽철은;민병구
    • 대한의용생체공학회:의공학회지
    • /
    • 제5권1호
    • /
    • pp.55-62
    • /
    • 1984
  • A digital spectrum analysis technique was used to estimate the tissue characteristic parameters (transmission velocity and attenuation coefficient) in the phantom study and the human liver's ultrasound scanning. The soft tissue equivalent phantom was made with the combination materials of agar, water, powdered graphite, and n-propyl alcohol. In the human study, twenty five normal subjects and three patients with liver diseases were studied using the ultrasonic reflection signals and the spectrum analysis method The following results were obtained; 1. The soft tissue-equivalent materical could be produced with various acoustic parameters by changing the composition amount of the powdered graphite and n-propyl alcohol. 2. Attenuation coefficients of normal human liver tissue were estimated to be 0. 36 dB/cm MHz$\pm$0.11. In patients with liver disese, tile attenuation coefficients were shown to be different from the above normal values.

  • PDF

관전압(管電壓)과 조사야(調査野) 및 피사체(被寫體)의 변화에 따른 선량분포(線量分布) (Dosimetry according to the X-ray Tube Voltage, Radiation Field and the Object Thickness)

  • 이상석;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제3권1호
    • /
    • pp.73-80
    • /
    • 1980
  • We studied about dosimetry according to the X-ray tube voltage, radiation field object thickness and obtained results as follow. 1. Secondary ray involing rate in the penetrated radiation increased proportion to the tube voltage, but its rate is more larger at the small radiation fields. than large fields. 2. Secondary ray involving rate in the penetrated radiation increased at thick object and large exposure fields. But saturated phenomenon appeared at limited field. 3. Secondary involving rate of acryl phantom is more top place than water, paraffin and aluminum phantom.

  • PDF

정위적 방사선 수술시 치료위치에서의 정위적 표적점 확인을 통한 자기공명영상 획득의 정확도 연구 (Verification of Stereotactic Target Point Achieved by Acquisition of MR Image in Actual Treatment Position of Radiosurgery)

  • 윤형근;신교철;김영식
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.89-94
    • /
    • 1998
  • 자기공명영상을 정위적 방사선 수술에 이용하기 위한 우선 과제로 비교적 균일한 phantom에서 자기공명영상으로 구한 정위적 표적점이 실제 방사선수술시의 방사선 빔의 isocenter와 일치하는지 확인하고자 하였다. 무 속에 임의의 표적점이 표시된 선량측정용 필름을 끼우고 head ring 을 고정시킨 다음 자기공명영상올 얻어 방사선 수술용 planning computer 로 표적점의 정위적 좌표를 구한 다음 실제 치료와 같이 무 phantom 을 테이블에 고정한 후 구해진 표적점의 좌표를 isocenter로 하여 방사선을 조사하고 필름을 현상하여 필름에 표시한 표적점과 실제 방사선이 조사된 부위의 선량분포의 중심을 비교하였는데 오차가 0.5 mm 이내였다. 따라서 무와 같은 비교적 균일한 phantom 에서는 표적점과 실제 방사선이 조사된 부위의 선량분포의 중심이 잘 일치함을 알 수 있었다. 또 다른 방법으로 자기공명영상의 왜곡의 정도를 직접 확인하기 위해서 아크릴에 1 cm 간격으로 구멍을 뚫고 오일방울을 넣어준 후 아크릴 phantom을 무 속에 수평과 수직방향으로 삽입한 뒤 자기공명영상을 얻은 후 각각의 좌표를 구하여 자기공명영상의 수평과 수직방향에서 왜곡의 정도를 측정하였다. 결과는 균일한 물질 내에서는 7 cm 거리에서 0.4 mm 이내의 오차를 보여서 비교적 잘 일치하였다. 그런데 이 측정과정에서 device 자체와 digitizing 과정의 오차가 있는 것으로 판단되므로 더 정교한 device 의 제작이 필요한 것으로 생각된다.

  • PDF

심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발 (Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT)

  • 야마모토토모아키;김정민;이기성;타카야마테루히코;키타하라타다시
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.389-399
    • /
    • 2008
  • 단일광자방출컴퓨터단층촬영(SPECT) 시 정확도의 개선을 위하여 산란과 감약의 보정, 분해능의 개선이 매우 중요하다. 특히 호흡이나 맥동에 대한 심장의 움직임은 보정 에러의 원인이 된다. 심장 팬텀이 보정방법에 대한 검증을 위해 사용되고 있으나, 현재 사용 중인 팬텀들은 실제 인체 데이터와 다른 점이 많이 나타나고 있다. 즉 팬텀을 사용한 결과는 임상데이터와 같게 취급할 수가 없다. 저자들은 흉곽의 인체 구조와 같은 신뢰성 있는 새로운 팬텀을 개발하였다. 새로운 팬텀은 폐와 심장의 전면, 측면 및 상부가 접하는 작은 종격구조를 가지고 있다. 용기는 아크릴로 만들었으며 종격은 물 등가물질을 사용하여 제조하였다. 폐는 에폭시레진의 고형 폴리우레탄 폼을 사용하였다. 5가지 크기의 심장은 게이트 심근관류 SPECT의 정량적 분석을 위하여 개발되었다. 심장팬텀들의 종격은 같은 포지션에 위치할 수 있도록 고안되었다. 완성된 팬텀은 간과 담낭에 부착되고 각각 높이 조절이 가능하다. 5개의 심실의 용적은 각각 150.0, 137.3, 83.1, 42.7과 38.6ml이다. 새로운 팬톰을 사용하여 SPECT 검사를 시행하고 보정법을 적용한 후에 영상의 차이를 검토하였다. 심장의 3차원 단층상이 효율적으로 재구성 되었으며 여러 가지 보정방법의 차이를 나타내기 위하여 주관적 평가도 시행하였다. 저자들은 SPECT영상과 QGS(Quantitative Gated SPECT) 결과로서 보정방법의 차이를 나타낼 수 있는 새로운 팬텀을 개발하여 보고하는 바이다.

  • PDF

Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교 (Comparison of Attenuation Correction Methods for Brain SPECT Ima)

  • 조진우;김창호;나수경;이귀원
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.120-125
    • /
    • 2012
  • 이 연구의 목적은 Brain SPECT (Single Photon Emission Computed Tomography)의 Non-attenuation correction (AC-non) 영상에 대한 attenuation correction(AC) 방법 중 Chang's method와 CT based attenuation correction(AC-CT) 사이의 count를 비교하기 위함이다. phantom study는 증류수로 채워진 hoffman 3D phantom에 $^{99m}Tc$ 37Mbq을 투여하였고, patient study는 normal volunteer에 $^{99m}Tc$-HMPAO 750Mbq를 정맥주입하고 Siemens사의 Symbia T6로 Brain SPECT 영상을 획득하였고 뇌 정량 분석을 하였다. 각각의 방법들을 적용한 transverse image는 같은 위치에서 재구성 되었으며 각각 10, 20, 30번째 slice에서 6개의 region of interest(ROI)를 그려 AC-non 과 AC-CT 그리고 Chang's method의 count를 비교하였다. phantom study에서 AC-non, AC-CT, Chang's method의 각각 평균 count는 $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, $8752.6{\pm}896.5$이었으며 patient study에서 $5460.8{\pm}519.6$, $15320{\pm}1171.6$, $12795{\pm}1422.1$이었다. phantom study에서 AC-CT와 AC-non 사이의 비는 3.70이고 Chang's method와 AC-non 사이의 비는 1.92였으며 patient study에서는 각각 2.85, 2.38이었다. 우리는 이 연구를 통하여 AC-CT가 Chang's method보다 더 높은 AC을 해준다는 걸 알 수 있었다. 그리고 Chang's method는 patient study에서의 AC 값이 phantom study에서의 AC값보다 더 높다는 것을 알 수 있었다. brain SPECT/CT를 시행하는 경우 scatter correction을 같이 시행하고 bone에 의한 감쇠 정보를 반영할 수 있는 AC-CT가 chang's method보다 정확하다 할 수 있겠다.

  • PDF

1.0Tesla 자기공명 영상장치에서의 분광영상기법에 관한 연구 (Spectroscopic Imaging at 1.0Tesla MR Unit)

  • 이윤;류택현;오창현;안창범;이흥규;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.517-527
    • /
    • 1997
  • Magnetic Resonance Spectroscopic Imaging is a methodology combining the imaging and spectroscopy. It can provide the spectrum of each areas of image so that one can easily compare the spectrum of one position to another position of the image. In this study, we developed pulse sequence or the spectroscopic imaging method, RF wave forms or the saturation of water signal, computer simulations to validate our method, and confirmed the methodology with phantom experiment. Then we applied the spectroscopic method to human subject and identified a few important metabolites in in vivo. To develope a water saturating RF waveform, we used Shinnar-Le-Roux algorithm and obtained maximum phase RF waveform. With this RF pulse, it could suppress the water signal to 1:1000. The magnet is shimmed to under 1.0ppm with auto-shimming technique. The saturation bandwidth is 80Hz(2ppm). The water and fat seperation is 3.3ppm(about 140Hz at 1 Tesla magnet), the bandwidth is enough to resolve the difference. But we are more concerned about the narrow window in between the two peaks, in which the small quantity of metabolites reside. We performed the computer simulation and phantom experiments in 8*8 matrix form and showed good agreement in the image and spectrum. Finally we applied spectroscopic imaging to the brain of human subject. Only the lipid signal was shown in the periphery region which agrees with the at distribution in human head surface area. The spectrum inside the brain shows the important metabolites such as NAA, Cr/PCr, Choline. We here have shown the spectroscopic imaging which is normally done above 1.5 Tesla machine can be performed in the 1 Tesla Magnetic Resonance Imaging Unit.

  • PDF

Evaluation of dose distribution from 12C ion in radiation therapy by FLUKA code

  • Soltani-Nabipour, Jamshid;Khorshidi, Abdollah;Shojai, Faezeh;Khorami, Khazar
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2410-2414
    • /
    • 2020
  • Heavy ions have a high potential for destroying deep tumors that carry the highest dose at the peak of Bragg. The peak caused by a single-energy carbon beam is too narrow, which requires special measures for improvement. Here, carbon-12 (12C) ion with different energies has been used as a source for calculating the dose distribution in the water phantom, soft tissue and bone by the code of Monte Carlobased FLUKA code. By increasing the energy of the initial beam, the amount of absorbed dose at Bragg peak in all three targets decreased, but the trend for this reduction was less severe in bone. While the maximum absorbed dose per bone-mass unit in energy of 200 MeV/u was about 30% less than the maximum absorbed dose per unit mass of water or soft tissue, it was merely 2.4% less than soft tissue in 400 MeV/u. The simulation result showed a good agreement with experimental data at GSI Darmstadt facility of biophysics group by 0.15 cm average accuracy in Bragg peak positioning. From 200 to 400 MeV/u incident energy, the Bragg peak location increased about 18 cm in soft tissue. Correspondingly, the bone and soft tissue revealed a reduction dose ratio by 2.9 and 1.9. Induced neutrons did not contribute more than 1.8% to the total energy deposited in the water phantom. Also during 12C ion bombardment, secondary fragments showed 76% and 24% of primary 200 and 400 MeV/u, respectively, were present at the Bragg-peak position. The combined treatment of carbon ions with neutron or electron beams may be more effective in local dose delivery and also treating malignant tumors.

TLD를 이용한 X-선 수중 흡수선량 측정 및 해석 (Measurement and Analysis of X-ray Absorbed Dose in Water Phantom using TLD)

  • 오장진;전재식;하석호;김원식;황선태
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.21-28
    • /
    • 1988
  • LiF : PTEE를 사용하여 중경 X-선(HVL : 0,29, 0.84, 1.60, 2.62mmCu) 영역에 대한 수중 흡수선량을 측정 해석하였다. 이때 선량계 (0.4mm ${\times}\;{\phi}$12.5mm, hot-pressed LiF TLD-700)는 루사이트로 둘러 싸여 있고 물의 흡수선량은 각각의 TL출력 값에 Burlin의 공동이론을 적용하여 해석하였다. 그 결과 물 팬텀 속 깊이 5cm에서 흡수선량률의 측정 오차는 최대 ${\pm}5%$로 나타났다. 이 측정값을 측정 오차가 ${\pm}2%$의 간접절대측정방법인 이온화법에 의한 측정값과 비교한 결과 두 값의 차이는 LiF : PTFE의 측정오차 범위 내에서 일치하였다. 이와같은 결과로 LiF : PTFE를 이용한 수중 흡수선량 측정의 신뢰성을 확인할 수 있게 되었으며 이는 중경 X-선 영역에 대한 선량당량 평가의 근거로 활용 될 수 있을 것이다.

  • PDF

쐐기필터 사용 시 레디오크로믹 필름을 이용한 조직에 따른 선량분포 연구 (Dose Distribution According to the Tissue Composition Using Wedge Filter by Radiochromic Film)

  • 김연래;이정우;박병문;정재용;박지연;서태석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.157-164
    • /
    • 2012
  • 본 논문의 목적은 쐐기필터를 사용한 방사선조사면에서 다양한 조직전자밀도가 선량분포에 미치는 영향을 분석하고자 함이다. 구성된 물질에 따라 밀도가 다른 고체 팬텀, 코르크팬텀, 그리고 공기층에서 동적쐐기필터와 금속쐐기필터를 이용하여 선량분포의 변형정도를 평가하였다. 본 실험에서는 매질 내 삽입이 용이하고 우수한 선량특성을 가지고 있는 레디오크로믹 필름(Gafchromic EBT2, International Speciality Products, NJ)을 사용하였다. 선형가속기 6 MV 광자선을 이용해서 $10{\times}10cm^2$ 조사면에 400 MU를 조사하였다. 필름의 선량분포는 선량 분석프로그램을 이용하여 조사면 내 영역과 반음영 영역을 분석하였다. 조직의 밀도가 같을 때 동적쐐기필터와 금속 쐐기필터의 선량분포는 금속 쐐기필터 선량이 동적쐐기필터 선량보다 높게 나타났다. 조직전자밀도가 다른 부위에 쐐기필터의 종류에 따른 선량분포는 고체팬텀과 코르크 팬텀에서 2% 이내 차이를 나타내고 있었다. 그러나 공기층에서 선량분포는 고체팬텀이나 코르크 팬텀의 선량분포와 큰 차이를 보이고 있다. 공기층에서 쐐기필터의 선량분포는 쐐기 사용 효과가 나타나지 않고 있다. 쐐기필터의 두꺼운 부분과 얇은 부분 밖에서 반음영의 크기는 1 cm에서 2 cm 정도 크게 두꺼운 부분에서 크게 나타났다. 그리고 금속 쐐기필터에서 반음영이 동적쐐기필터 보다 평균 6.4%정도 높게 반음영이 나타났다. 본 실험을 통해 공기층과 같이 조직전자밀도 현저히 작은 매질에서는 쐐기필터의 효과가 크게 떨어지는 것과 불균질 물질에 따라 흡수되는 선량분포가 크게 변형되는 것을 알 수 있었다. 따라서 조직전자밀도의 차이가 큰 부위의 방사선치료계획 시 쐐기필터의 적용에 따른 적절한 보정이 이루어져야 한다.

CT 검사에서 Lateral Sliding Table의 유용성 평가 (Usability Evaluation of Lateral Sliding Table in CT Examination)

  • 최정훈;공창기;송종남;한재복
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.677-684
    • /
    • 2020
  • CT 검사 시 좌,우 X축 방향의 Miscentering은 선량과 화질에 영향을 준다. CT Gantry Isocenter와 검사 목적부위의 Center가 일치되도록 Lateral Sliding Table을 이용하여 일치시켰을 때 화질은 더욱 좋아지고 피폭선량은 줄어든다. 중심 이탈에 따른 선량 비교 CTDI (mGy) 측정을 위하여 CTDI Head Phantom (Kimda, Korea)과 선량측정계(Ray Safe, Sweden)를 사용하였고, 중심 이탈에 따른 균일도의 차이를 보기 위한 노이즈의 측정은 Water Phantom (HITACHI, Japan) 을 사용하였다. 중심 이탈에 따른 선량 비교 CTDI(mGy)를 위해 선량을 측정한 결과 Isocenter 에서 X 축으로 20 mm 씩 이동하여 80 mm로 이동될때까지 지속적으로 선량이 적어졌고 정확한 선량이 입사되지 않았다. 중심 이탈에 따른 균일도의 차이를 보기 위해 SD값을 측정하였고 20 mm 씩 이동하여 80 mm로 이동될 때까지 지속적으로 노이즈가 커졌다. 콜리메이션의 범위는 중심이 탈된 범위만큼 콜리메이션 범위가 늘어났고 피폭의 범위가 커졌다. Lateral Sliding Table을 이용하면 Isocenter를 쉽게 맞출 수 있고, Isocenter에서 벗어난 위치의 심장검사, Extremity bone과 Shoulder같은 부위에서 Isocenter를 맞춰 영상의 화질을 높일 수 있고, Isocenter를 맞춰 콜리메이션을 대폭 축소하여 검사할 수 있으니 불필요한 피폭선량 감소에 활용할 수 있을 것으로 사료된다.