Dosimetry according to the X-ray Tube Voltage, Radiation Field and the Object Thickness
관전압(管電壓)과 조사야(調査野) 및 피사체(被寫體)의 변화에 따른 선량분포(線量分布)
- Lee, Sang-Suk (Dept. of Radiotechnology, Dong Nam Junior Health College) ;
- Park, Sung-Ock (Dept. of Radiotechnology, Dong Nam Junior Health College)
- Published : 1980.07.18
Abstract
We studied about dosimetry according to the X-ray tube voltage, radiation field object thickness and obtained results as follow. 1. Secondary ray involing rate in the penetrated radiation increased proportion to the tube voltage, but its rate is more larger at the small radiation fields. than large fields. 2. Secondary ray involving rate in the penetrated radiation increased at thick object and large exposure fields. But saturated phenomenon appeared at limited field. 3. Secondary involving rate of acryl phantom is more top place than water, paraffin and aluminum phantom.