• 제목/요약/키워드: water operation

검색결과 4,054건 처리시간 0.031초

KModSim 모형(模型)에 의한 도시지역(都市地域) 다중수원(多衆水源) 송수관망간(送水管網間) 최적(最適) 연계(連繫) 운영(運營) 연구(硏究) (An Optimal Conjunctive Operation of Water Transmission Systems from Multiple Sources with applying EPAnet and KModSim Model)

  • 류태상;정태성;고익환;하성룡
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.500-504
    • /
    • 2008
  • The objective of this paper is to evaluate the feasibility of using an optimization model as a effective way to search conjunctive operation scheme to meet two conditions; one is to minimize the electric cost for pumping and another is to meet the water demand for satisfying customers. The feasibility is confirmed as comparing the best combinations of pumps between multi-regional water supply networks from multiple sources which are obtained through an optimization modeling and EPAnet modeling. KModsim model, a network optimization model, was used to determine conjunctive operation scheme in the pipe system. KModsim, based on Lagrangian Relaxation algorithm, is useful for modeling network system and obtaining simultaneously pump combination and water allocation with given input option such as energy unit cost supplying from a source into a consumer, operating pumping combination. This study develops the procedure of determining optimal conjunctive operation scheme with using KModsim model. As a study region, the water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. The EPAnet hydraulic simulation result(Ryu et al, 2007, KSWW) gave input data for optimization model; energy unit price(won/$m^3$), water service available area etc.. It was assured that the combination of pump operation through optimum conjunctive operation is to be optimum scheme to obtain the best economic water allocation with comparison to the hydraulic simulation result such as electric cost and pump combination cases. The results obtained through the study are as follows. First, It was found that a well-allocated water supply scheme, the best combination of pump operation through optimum joint operation, promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. Second, an application of KModSim, a network model, gave the amount of water allocation from each source to a consumer with consideration of economic supply. Finally, in a service area available to supply through conjunctive operation of existing inter-regional water supply networks within short distance, a conjunctive operation is useful for determining each transmission pipeline's service area and maximizing the effectiveness of optimizations in pumping operation time.

  • PDF

Canal Operation Simulation of Middle Route Project

  • Fan, Jie
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.26-32
    • /
    • 2008
  • Middle Route Project, the largest water conveyance system in China delivers the water of Changjiang River to North China. In order to create canal operation simulation system, mathematical models are established based on the analysis of hydraulics about steady flow, unsteady flow, and check gate. By simulating the canal operation behavior, we improved the check gate control algorithm and predicted the change process of water surface and flow profile which is very valuable to actual canal operation.

  • PDF

소독능을 고려한 송수펌프 최적운영기법 개발 (Development of the method for optimal water supply pump operation considering disinfection performance)

  • 형진석;김기범;서지원;김태현;구자용
    • 상하수도학회지
    • /
    • 제32권5호
    • /
    • pp.421-434
    • /
    • 2018
  • Water supply/intake pumps operation use 70~80% of power costs in water treatment plants. In the water treatment plant, seasonal and hourly differential electricity rates are applied, so proper pump scheduling can yield power cost savings. Accordingly, the purpose of this study was to develop an optimal water supply pump scheduling scheme. An optimal operation method of water supply pumps by using genetic algorithm was developed. Also, a method to minimize power cost for water supply pump operation based on pump performance derived from the thermodynamic pump efficiency measurement method was proposed. Water level constraints to provide sufficient disinfection performance in a clearwell and reservoirs were calibrated. In addition, continuous operation time constraints were calibrated to prevent frequent pump switching. As a result of optimization, savings ratios during 7 days in winter and summer were 4.5% and 5.1%, respectively. In this study, the method for optimal water pump operation was developed to secure disinfection performance in the clearwell and to save power cost. It is expected that it will be used as a more advanced optimal water pump operation method through further studies such as water demand forecasting and efficiency according to pump combination.

이수관리곡선에 의한 증고저수지의 하천유지유량 공급 가능성 평가 (Evaluation of Supplying Instream Flow by Operation Rule Curve for Heightening Irrigation Reservoir)

  • 이재남;노재경
    • 농업과학연구
    • /
    • 제37권3호
    • /
    • pp.481-490
    • /
    • 2010
  • Baekgog reservoir is located in Jincheon county, Chungbuk province, of which full water levels will be heightened from EL. 100.1 m to EL. 102.1 m, and total storages from 21.75 $Mm^3$ to 26.67 $Mm^3$. The simulation for reservoir inflow was conducted by DAWAST model. The annual average irrigation water was estimated to 33.19 $Mm^3$ supplied to 2,975 ha and the instream flows could be allocated with 0.14 mm/d from October to April with annual average of 2.52 $Mm^3$. The operation rule curve was drawn using inflow, irrigation, and instream flow requirements data. The reservoir water storage was simulated on a daily basis in case of both normal and withdrawal limit operation. In case of normal operation, the annual average irrigation water supply increased from 31.95 $Mm^3$ to 33.32 $Mm^3$, the instream water supply from 2.40 $Mm^3$ to 2.44 $Mm^3$, the water storages from 15.74 $Mm^3$ to 19.88 $Mm^3$, and the water supply reliability from 77.3 % to 81.6 %. In case of operation with withdrawal limit, the amount of instream water supply was 2.52 $Mm^3$ from reservoir regardless of the condition while the water storage increased from 16.77 $Mm^3$ to 20.65 $Mm^3$. The irrigation water supply capacity was appropriate for the case of normal operation with 2 m heightened condition. The present instream water supply capacity was 35,000 $m^3$/d (6.86 $Mm^3$/y) while 42,000 $m^3$/d (8.36 $Mm^3$/y) in 2 m heightened condition in case of withdrawal limit operation.

이수관리곡선에 의한 논 관개지구의 윤환관개모형 (A Rotational Irrigation Scheduling for an Irrigated Paddy Blocks with Operation Rule Curve)

  • 김태철;이재면;이덕주
    • 한국농공학회지
    • /
    • 제45권5호
    • /
    • pp.67-76
    • /
    • 2003
  • The principal operation rule of irrigation reservoir is to accelerate the water use and supply water actively when water is sufficient, and to restrict water use and supply water deficiently in order not to stop the irrigation activity when water is scarce. In drought seasons. water should be saved in order to keep the reservoir not to be dried up during the irrigation season. It is important to know how much water should be saved, depending on the rice-growing season and water storage volume. For the drought control of irrigation reservoirs. the rotational irrigation scheduling in paddy with the operation rule curve developed in this study could be utilized as a software program to install TM/TC system for irrigation water supply by automation facilities.

낙동강하구둑 수문운영에 따른 수질 영향 분석 (Analysis of the Water Quality by Various Gate Operation Effects at Nakdong Estuary Barrier)

  • 이상진;류경식;황만하;이상욱
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.651-658
    • /
    • 2008
  • Estuary barrier is a hydraulic structure constructed to supply safely water as protecting chlorine penetration of sea water. However, the barrier brings about a problem which decreases original functions of estuary because hydraulic ecology was disrupted as obstructing natural water exchange between fresh water and sea water. It is important to supply Enough fresh water in the estuary ecosystem. But it is possible to reduce the problems brought from barrier throughout efficient water gate operation of estuary barrier. It was shown in this study that the environmental effect of estuary in Nakdong river was investigated according to the control of water level. Also, the basic information about the effective water gate operation was provided. The analysis results showed that the release rate of estuary was increased about 20% as changing the operational water levels. This helps supplying fresh water durably to the mixing zone. Also, CE-QUAL-W2 model was utilized to assess water quality. The values of BOD and COD were not changed in estuary area. From the result, it was analyzed the effect of water quality according to the water gate operation was not indicated.

현장조사 관개 기준에 따른 농업용 저수지 운영 분석 (Agricultural Reservoir Operation Analysis According to Surveyed Irrigation Guideline)

  • 김마가;최진용;방재홍;윤푸른;김귀훈
    • 한국농공학회논문집
    • /
    • 제65권5호
    • /
    • pp.37-49
    • /
    • 2023
  • The drought risk has been increasing recently due to climate change causing the extreme climate to be more frequent. In order to supply agricultural water stably under drought, it is necessary to operate an agricultural reservoir in response to drought. To this end, it is crucial to establish appropriate drought response operation rules considering weather conditions and reservoir status. In the reservoir operation simulation, the supply amount differs from the actual reservoir supply for many reasons, including maintaining water levels for supply and accommodating farmers' requests. So, for a more realistic reservoir operation simulation, it is necessary to reflect the reservoir operation rules of the actual water management site. Therefore, in this study, through a survey, the standards for limitation of agricultural water supply applied to agricultural reservoirs in Korea were investigated, and the criteria for drought response reservoir operation (DRO) were established based on the survey. Then, the DRO was applied to the irrigation period for nine subject reservoirs. The applicability was evaluated by comparing the DRO result to the operation result of HOMWRS (Hydrological Operation Model for Water Resources System). The reservoir drought index, storage rate, and daily supply were compared for evaluation. From the result, DRO showed more stable operation results in most cases against drought as it has fewer days of water supply limitation and a somewhat reservoir storage rate which can be utilized for prolonged drought.

물관리 디지털 전환, 디지털 트윈 기반 플랫폼 구축 (Water management digital transformation, digital twin-based water management platform development)

  • 김현진;권문혁;조완희;김기철;김진곤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.284-287
    • /
    • 2022
  • K-water는 기후위기에 따른 물관리의 복잡성, 불확실성에 대응하기 위해 수문자료 센싱, 고품질의 데이터 관리 등 ICT 인프라 운영 경험 및 물관리 역량을 기반으로 디지털트윈 물관리 플랫폼을 구축하였다. 본 플랫폼은 유역내 실시간 기상·수문 관측자료와 유관기관 정보를 연계하여 3차원 지형자료에 표출하고 홍수, 수질 등 다양한 상황을 시뮬레이션하여 결과를 표출 및 분석하고 이에 대한 피드백을 통해 최적의 의사결정을 지원하는 체계로 구성되어 있다. 본 플랫폼은 섬진강유역을 대상으로 시범구축 하였으며, 향후 5대강 유역을 대상으로 공간적 범위를 확대할 계획이다. 이를 통해 댐 하류·지류 합류부 등 재해 취약지점까지 아우르는 종합적인 물관리 의사결정의 One-System으로 확장할 계획이다. 또한 안전하고 효율적인 물관리를 기반으로 새로운 물산업 생태계를 조성하고, 민간기업과의 기술협력을 통해 디지털 물산업 기술 경쟁력 확보에도 기여하고자 한다.

  • PDF

운영 중 터널에 작용하는 간극수압 평가기법 (Evaluation of pore water pressure on the lining during tunnel operation)

  • 신종호;신용석;최규철
    • 한국터널지하공간학회 논문집
    • /
    • 제10권4호
    • /
    • pp.361-369
    • /
    • 2008
  • 지중터널은 대부분 지하수위 하부에 위치하므로 지하수 처리문제는 터널의 장기운영에 있어 매우 중요하다. 배수형터널의 경우 수리기능이 원활하면 라이닝에 수압이 작용하지 않으나 장기 운영으로 인해 배수시스템의 열화가 진행되면서 라이닝 배면에 설계 시 고려하지 않았던 간극수압이 작용하게 되는데, 이를 잔류수압이라 한다. 잔류수압은 피에조미터로 그 측정이 가능하나 이는 라이닝 및 배수시스템을 훼손할 염려가 있어 부적합하기 때문에 라이닝을 손상시키지 않으면서 작용수압을 평가할 수 있고, 운영 중 라이닝의 건전도 평가(health monitoring) 시 수압상태의 파악이 가능한 비파피 예측기법이 요구된다. 본 논문에서는 이론적 및 수치해석적 방법을 사용하여 운영 중 터널에 작용하는 간극구압(잔류수압) 예측기법을 제시하였으며, 본 해석방법을 이용하면 비파괴 방법으로 라이닝에 작용하는 간극수압의 파악이 가능하다. 제안된 방법은 이론적 예측기법과 수치해석 결과인 정규화 간극수압 분포곡선과를 병용함으로써 터널 운영단계에서의 잔류수압에 대한 안정성 검토에 유용하게 활용될 수 있다.

  • PDF

빗물저장조에서 입자의 제거특성 및 운전과 설계시 고려사항 (Particle Removal in a Rainwater Storage Tank, and Suggestions for Operation & Design)

  • 문정수;유형근;한무영
    • 상하수도학회지
    • /
    • 제21권1호
    • /
    • pp.131-138
    • /
    • 2007
  • A rainwater utilization facility consists of its catchment area, treatment facility, storage tank, supply facility and pipes in general. The rainwater storage tank which occupies the largest area of the facility has been usually considered quantitatively for determining the storage capacity. Hence, there is little information on water quality improvement by sedimentation in a rainwater storage tank in operation. In this study, we measured the rainwater quality in a rainwater storage tank in operation during late spring and summer, and showed water quality improvement of turbidity removal of 25~46% by sedimentation in a rainwater storage tank under a fixed water level without inflow and outflow after runoff ceased. It is necessary to have a considerable distance between the inlet and outlet of the tank and, if possible, it is recommended that the design should allow for an effective water depth of over 3 m and supply rainwater near the water surface. The operation method which increases the retention time by stopping rainwater supply for insuring low turbidity is recommended when the turbidity of rainwater runoff is high. And also more efficient operation and maintenance of the rainwater utilization facility is expected through the tailored design and operation of the facility considering particle removal and behavior.