• 제목/요약/키워드: water level control

검색결과 1,956건 처리시간 0.033초

합병정화조 기술현황 및 전망 (Current Condition and Prospect of On-Site Domestic Wastewater Treatment Technologies)

  • 임연택
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 제6회 하계 Workshop (98 한국막학회, 국립환경연구원 국제 Workshop, 수자원 보전과 막분리 공정)
    • /
    • pp.95-112
    • /
    • 1998
  • Water quality in the public water course has been polluted more seriously than ever before due to the increase of the number and aremount of pollution sources such as domestic and industrial wastewater. For water quality conservation, the Korean government has been trying to construct sewage treatment facilities continually, of which treatment capacity reached to 11,452,400m$^{3}$/day in 1996. Night soil treatment facilites of m nationwide have the treatment capacity of 24,038m$^{3}$/day. But water quality has not been improved because the sewer systems were insufficient and the treatment efficiencies of sewage were not high, enough. For renovation of water quality, miscellaneous domestic wastewater must be treated because 27g BOD/day out of total 40g BOD/person-day come from miscellaneous wastewater, comparing to 13g BOD/day from night soil. However, sole treatment purifier treat only night soil from the flushing toilet. Therefore, it may be desirable to treat the miscellaneous domestic wastewater and the night soil from flushing toilet together by joint treatment purifier system as on-site domestic wastewater treatment technology. In Korea, the joint treatment purifier system, introduced in 1997, have the benefit as follows; i) good water poiluion control effect, ii ) good effect on river water flow, iii) water pollution control with sewage treatment facility, and iv) rapid pollution control effect, etc. In order to achieve a good effect as stated before, i ) strengthening effluent guideline including BOD, nitrogen and phosphorus, ii ) specializing operation to maintain high performance, and iii) supporting its construction and maintenance costs by the governmental level may be necessary: In addition, automation system of joint treatment purifier, technology for its package and compactness, and a new bio-media bio-filter with higher capacity should be further developed in agreement with a more stringent effluent guideline.

  • PDF

Research on the construction concept and general framework of Smart Water Resource

  • Tian, Yu;Li, JianGuo;Jiang, Yun-zhong
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.216-216
    • /
    • 2015
  • Frequent hydro-meteorological events caused by global climate change and human exacerbate activities, make the water resource problem more complicated. The increasing speed urbanization brings a significant impact on the city flood control and security, water supply safety, water ecological security, water environment safety and the water engineering security in China, and puts forward higher requirements to urban water integrated management, undoubtedly which become the biggest obstacle for water ecological civilization construction, thus urgent requiring an advanced methods to enhance the effectiveness of the water integrated management. The other fields of smart ideas point out a development path for water resource development. The construction demand of smart water resource is expounded in the paper, combining the philosophy of modern Internet of things with the application of cloud computing technology. The concept of smart water resource is analyzed, the connotation characteristics of smart water resource is extracted, and the general model of smart water resource is refined. Then, the frame structure of smart water resource is put forward. The connotation and the overall framework of the smart water resource represent a higher level of water resource informationization development and provide a comprehensive scientific and technological support to transform water resource management from an extensive, passive, static, branch and traditional management to a fine, active, dynamic, collaborative and modern management.

  • PDF

말뚝 결합 블록식 안벽의 수평변위 억제에 대한 수치해석 연구 (Numerical Analysis of Block Type Quay Wall with Piles for Restraining Horizontal Deformation)

  • 권순구;이원효;김태형
    • 한국해안·해양공학회논문집
    • /
    • 제35권6호
    • /
    • pp.155-163
    • /
    • 2023
  • 말뚝이 결합된 블록식 안벽의 말뚝 근입깊이의 영향에 따른 거동파악을 하기 위해 잔류수위차 크기와 상치 콘크리트 유무 조건에 대하여 2차원 수치해석을 실시하였다. 수치해석 결과, 말뚝의 근입에 따라 안벽의 수평변위의 억제 효과가 나타나는 것을 확인하였으며, 말뚝이 사석층까지 근입된 경우에서 수평변위 억제 효과가 가장 크게 나타났다. 말뚝이 근입되지 않은 조건에서는 잔류수위차가 증가함에 따라 안벽의 수평변위도 비례적으로 증가하는 것으로 나타났다. 하지만 말뚝이 지반에 근입된 경우 잔류수위차가 증가하더라도 안벽의 수평변위에 대한 제어가 크게 발휘되었다. 상치콘크리트 유·무에 따른 블록식 안벽의 수평변위는 차이가 거의 없는 것으로 나타났다. 말뚝의 근입깊이가 사석층까지 근입된 경우 조건에서는 말뚝이 짧은 말뚝에서 보이는 회전 거동을 보이는 것으로 나타났다. 말뚝의 근입깊이가 더 깊어짐에 따라 중간 말뚝의 거동과 같은 휨거동 양상을 보이는 것으로 해석되어 말뚝이 결합된 블록식 안벽에서 말뚝이 수평변위 억제에 크게 기여하는 것을 알 수 있다.

A Physiological Stimulating Factor of Water Intake during and after Dry Forage Feeding in Large-type Goats

  • Thang, Tran Van;Sunagawa, Katsunori;Nagamine, Itsuki;Kishi, Tetsuya;Ogura, Go
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권4호
    • /
    • pp.502-514
    • /
    • 2012
  • When ruminants consume dry forage, they also drink large volumes of water. The objective of this study was to clarify which factor produced when feed boluses enter the rumen is mainly responsible for the marked increase in water intake in the second hour of the 2 h feeding period in large-type goats fed on dry forage for 2 h twice daily. Six large-type male esophageal- and ruminal-fistulated goats (crossbred Japanese Saanen/Nubian, aged 2 to 6 years, weighing $85.1{\pm}4.89kg$) were used in two experiments. In experiment 1, the water deprivation (WD) control and the water availability (WA) treatment were conducted to compare changes in water intake during and after dry forage feeding. In experiment 2, a normal feeding conditions (NFC) control and a feed bolus removal (FBR) treatment were carried out to investigate whether decrease in circulating plasma volume or increase in plasma osmolality is mainly responsible for the marked increase in water intake in the second hour of the 2 h feeding period. The results of experiment 1 showed that in the WA treatment, small amounts of water were consumed during the first hour of feeding while the majority of water intake was observed during the second hour of the 2 h feeding period. Therefore, the amounts of water consumed in the second hour of the 2 h feeding period accounted for 82.8% of the total water intake. The results of experiment 2 indicated that in comparison with the NFC control, decrease in plasma volume in the FBR treatment, which was indicated by increase in hematocrit and plasma total protein concentrations, was higher (p<0.05) in the second hour of the 2 h feeding period. However, plasma osmolality in the FBR treatment was lower (p<0.05) than compared to the NFC control from 30 min after the start of feeding. Therefore, thirst level in the FBR treatment was 82.7% less (p<0.01) compared with that in the NFC control upon conclusion of the 30 min drinking period. The results of the study indicate that the increased plasma osmolality in the second hour of the 2 h feeding period is the main physiological stimulating factor of water intake during and after dry forage feeding in large-type goats.

댐건설의 환경영향평가 현황과 바람직한 발전방향 (Toward a better environment impact assessment on dam construction)

  • 이수재
    • 한국환경생태학회:학술대회논문집
    • /
    • 한국환경생태학회 2003년도 추계학술논문발표회 논문집
    • /
    • pp.55-72
    • /
    • 2003
  • Dam is a barrier constructed to divert, hold water and raise its level for purpose of water supply, irrigation, power generation, flood control, and recreational facilities, etc. Therefore, there are many inevitable environmental impacts on dam construction. We need some better tools to predict the impacts and mitigate measures before and after dam construction. For this purpose I discussed several feasible suggestions and provisions mainly related to environmental impact assessment.

  • PDF

홍수재난 대응을 위한 국가위기경보 4단계 설정기준 개선 (Improvement of National Risk Alarm 4-Stage Criteria for Flood Disaster)

  • 이수경;박재우;오은호
    • 한국콘텐츠학회논문지
    • /
    • 제18권3호
    • /
    • pp.369-377
    • /
    • 2018
  • 홍수 발생 시 제공되는 적절한 비상대처방안(EAP) 정보는 재난에 효과적으로 대응하기 위한 필수요소이며, 상습 침수지역과 예상지역의 인명 및 재산피해를 줄이는 중요한 역할을 한다. 국내에서 사용하는 대부분의 EAP는 국가위기관리기본지침의 위기경보 4단계를 근간으로 해당 시설물에 대한 단계별 대응업무를 규정하도록 되어 있다. 이와 관련하여 홍수통제소는 수위표 또는 해발고도를 기준으로 하천지점별 홍수주의보와 홍수경보를 계획홍수량의 50%와 70%를 기준으로 발현하고 있으나, 위기경보 각 단계별 설정기준과의 명확한 연관관계를 제시하고 있지 않다. 반면, 일본과 미국의 경우 수재해 대응단계를 구분하는데 있어 하천수위를 가장 중요한 판단기준으로 삼고 있으며, 국내보다는 높은 계획홍수위 설정기준을 갖고 있다. 이에 본 연구는 국내 하천홍수 대응 수재해 위기경보 4단계 설정기준을 개선하기 위하여 국내외 관련 규정 및 적용현황을 분석하였으며, 실무자 관점에서 실효성을 제고하기 위하여 위기경보단계별 설정기준을 상향조정하고 수위표 기준으로 표기방식을 개선하도록 제안하였다. 적용성 및 실효성 검증을 위하여 개선된 설정기준(안)을 수변구조물 재난대응 의사결정시스템에 적용하고 테스트베드에 대한 모의훈련을 실시하였다.

CSOs 저감을 위한 차집관거 최적화 시스템 (Optimal Sizing of Intercepting Flow for Reducing Pollution Loads Caused by CSOs)

  • 공민근;배기현;강우영
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.418-424
    • /
    • 2004
  • An abrupt high pollution loads in combined sewer systems is believed to be caused by first flushing actions and the resuspension of sediments deposited in sewers. Therefore, pollution loads in each flow regulator have a different tendency. This systems control intercepting flow in each flow regulator using water quality and water level. A desired quantity of intercepting flow was adjusted and the necessary slide position for a constant intercepting is calculated by Optimization programming. This systems make it possible to reduce pollution loads caused by CSOs to water body, may be alternative for the stable operation of STP through improving water quality to STP.

하천수 취수량 분석을 위한 전력량법의 적용성 연구 (A study on the applicability of power usage method for the analysis of river water intake)

  • 백종석;김치영;차준호;송재현
    • 한국수자원학회논문집
    • /
    • 제52권12호
    • /
    • pp.975-984
    • /
    • 2019
  • 하천수의 체계적이고 통합적인 관리를 위한 필수 전제로, 하천으로 공급되고, 하천에서 방류되는 유량 등의 기초자료 확보가 필요하다. 현행되는 하천수 사용 허가제도에 의하면 2017년 허가시설 중 59.1%는 유량 계측기기가 없는 것으로 확인되었고, 특히 농업용수의 경우, 보고량의 상당부분이 사용자의 자발적인 보고로 이루어져 신뢰성 있는 자료의 확보가 어려운 실정이다. 본 연구에서는 양수장의 전력사용량을 통해 유량을 산정하는 간접 유량 계측방법을 적용하여 경제적이고 신뢰성 있는 유량자료의 확보에 대한 연구를 수행하였다. 특히, 전력량법에 의해 산정된 유량이 하천의 수위에 따라 실측 유량과 차이가 나는 점에 집중하여, 하천수위를 반영한 전력량법의 개선 및 유량자료의 정확도 향상에 대한 적용성 연구를 수행하였다. 하천수위를 고려한 전력량법으로 산정된 유량을 회귀분석, 백분율 차이, 평균 제곱근 오차 등의 상관성 분석 방법 등을 이용하여 분석한 결과, 기존의 전력량법과 비교하여 보다 더 실측 유량에 근사한 결과를 산정하는 것으로 확인하였다. 이를 통해, 양수장에서는 기존의 전력량법으로도 신뢰성 있는 유량 자료를 확보할 수 있지만, 하천의 수위 변동폭이 큰 지점에서 개선된 전력량법을 사용한다면, 보다 정확한 하천수 취수량 자료를 확보할 수 있을 것으로 기대한다.

저수지 수변 식생 건강성 평가 (The Vegetation Health Assessment in Riparian Vegetation of Lake Reservoirs)

  • 김형대;구본학
    • 한국환경복원기술학회지
    • /
    • 제19권6호
    • /
    • pp.111-121
    • /
    • 2016
  • This study was carried out to assess the riparian vegetation health in the fluctuation area and vicinity of reservoirs. The results of this study could be a basic data to improve the ecological function and establish green-network of waterside ecosystem. The study site is Daecheong lake reservoirs which the representative landscape of Geum river and with great number of visitors near metropolitan city. The 6 survey plots of 2 survey area were selected, survey area 1 had 4 survey plots and survey area 2 had 2 survey plots, and to compare the study results 4 control plots were selected in Gyeongcheon reservoir. The main dominant specie of survey sites was Salix koreensis in tree and subtree layer, were Salix koreensis and Salix glandulosa. in shrub layer. 2 survey plots of Samjeongdong and Kyeongcheon reservoir were assessed as 'Good', 2 survey plots of chudong were assessed as 'Fair' in vegetation health assessment. In the fluctuation area from flood water level to low water level, 58 populations of Salix koreensis were found in survey sites and Salix koreensis, Salix glandulosa and Acer tataricum subsp. ginale were found in control sites. The most adequate species at the condition affected by inundation impacts would be Salix koreensis and Salix glandulosa was more healthy at the area less affected by inundation. This study was carried out the vegetation health assessment on Daecheong reservoir which has been advanced natural succession for more than 30 years after the construction. Further, it should carry continuously out the research on the planting model of the waterside ecosystem for ecological restoration.

개별배출시설 삭감잠재량 분석을 통한 수질오염총량제의 민간참여 활성화 방안 연구 (A Study on the Activation of Non-government Participation in Total Maximum Daily Load System using Private Discharge Facilities Reduction Potential Analysis)

  • 김홍태;신동석;김현정;최인욱;이미선;김용석
    • 한국물환경학회지
    • /
    • 제31권6호
    • /
    • pp.715-722
    • /
    • 2015
  • Four major river basin in Korea has been managed with Total Maximum Daily Load(TMDL) System. Water quality indicators as targeted pollutants for TMDL were BOD and TP. In order to satisfy water quality criteria, government allocation using public treatment facilities and its action plan has been used. However, the role to improve water quality were recently faced to its limitation. It is time to require the role of non-government allocation in private discharge facilities to control good water quality. This study investigated three different scenarios in reduction demands of non-government allocations about industry and private sewages. The three different scenarios were discharge under 1) legal water quality standard, 2) water quality level in 2011 and 3) current water quality level with maximum value in group. The results showed that reduction potential in water discharge for TP indicator was 1,118kg/day, under second scenario with 20% of deduction. This results arrived at 42% of whole reduction potential costs and 0.012mg/L improvement in water quality. In conclusion, to intrigue voluntary participation in non-government allocation, various benefits such as tax reduction, tax exemption, and water quality trading should be provided.