• 제목/요약/키워드: water foaming

검색결과 157건 처리시간 0.027초

폴리에틸렌 하수관 연결용 전기발포융착 이음관에 관한 연구 (A Study of Electro-foaming Fusion Wrap for Polyethylene Sewer Pipe)

  • 계형산;주경훈
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.343-354
    • /
    • 2012
  • A electro-foaming fusion wrap fitting for polyethylene sewer pipe was built and foaming mechanism has been studied. A foaming sheet, supporting sheet and clamping band is assembled into a all-in-one structured electro-foaming fusion wrap fitting. To specify foaming and fusion of electro-foaming fusion wrap for PE sewer pipe, series of fusion tests were performed in various conditions. A parallel plate compression test up to 50 % of inner diameter deflection has been performed to check integrity of fusion quality and it was found that there were no visible signs of crack in wrapped area of fitting. Also air tightness test based on KS M 3511-2 has been performed to evaluate perfectness of wrap fusion quality and we found there were no pressure drop up to 10 times higher value than KS standard regulation.

기포제 온도 및 희석농도에 따른 콘크리트용 기포제의 특성 (Properties of the Concrete Foaming Agent According to Temperature and Concentration)

  • 최지호;이민재;정지용;황의환;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.247-249
    • /
    • 2011
  • Pre-foaming, one of the manufacturing way of foamed concrete, is influenced by foaming agent. When the foaming agent diluted with water, surface tension and viscosity are varied. Therefore, this study is reviewing the surface tension, viscosity and unit weight of foam by experimental factor such as foaming agent types(AES, AOS, VS FP) and foam agent dilution concentration (1, 3, 5%) and temperature of materials (5, 10, 20℃). As an expeimental result, the surface tension and viscosity slightly increased with increasing concentrations. Meanwhile, when increasing temperature, the viscosity has decreased. FP produce relatively stable foams only in case 3% or more, which produce unstable foams containing large amount of water content by decreasing only insignificant surface tension when diluted at concentration of 1%.

  • PDF

홍게 가공회수 단백질의 거품 형성력 및 안정성 (Foaming Capacity and Foaming Stability of Protein Recovered from Red Crab Processing Water)

  • 김용진;신태선;오훈일
    • 한국식품영양학회지
    • /
    • 제9권3호
    • /
    • pp.325-330
    • /
    • 1996
  • Foaming capacity (FC) and stability (FS) of protein recovered from red crab (Chitinonecetes opilio) processing in water and soybean protein isolate were determined at pH 2.0~10.0 in water and NaCl solution. The FC values for both proteins showed the lowest values at the isoelectric point (pH 4.0) and increased nth an increase in pH above the isoelectric point. FC of RCP was higher than that of SPI at pH 10.0 in water and both NaCl solutions. FC of SPI increased with an increase in NaCl concentration at pH 4.0 and 6.0, but FC of RCP was not affected. The highest FS values for both proteins were obtained at pH 4.0 in water. At pH 2.0, FC of RCP decreased with NaCl concentration increase, but FS increased. NaCl concentration had little effect on FS of RCP at pH 4.0 and 6.0, but the FS decreased at pH 10.0. FS of SPI was similar to that of RCP at pH 2.0 and increased with NaCl concentration Increase from 0.1 to 0.5M NaCl at pH 10.0.

  • PDF

하수처리수 방류구의 거품발생 원인진단 및 저감방안: 국내 하수처리장 사례를 중심으로 (Cause Diagnosis and Reduction Measures of Foaming in the Treated Wastewater Outlet of D Wastewater Treatment Plant)

  • 신재기;조영수;김영성;황순진
    • 생태와환경
    • /
    • 제49권2호
    • /
    • pp.124-129
    • /
    • 2016
  • 본 연구는 하수처리장에서 최종 방류되는 하수처리수의 거품발생 원인분석과 저감방안을 제시하고자 수행되었다. 감조하천의 방류구에서 거품이 발생하는 것은 구조적인 문제점으로 파악되었다. 거품은 낙차에 의한 공기 연행과 확산방지막에 의한 내부축적이 주요한 원인이었다. 이러한 여건을 고려하여, 방류수로와 방류구 종단에서 미세스크린과 수중방류를 통해 거품발생을 완화시킬 수 있는 효과적인 방안을 제시하였다.

기포제가 모르터의 제성질에 미치는 영향에 관한 실험적 연구 (Experimental Studies on Influence of Foaming Agents on the Properties of Mortar)

  • 성찬용;황은
    • 한국농공학회지
    • /
    • 제27권1호
    • /
    • pp.46-61
    • /
    • 1985
  • This study was performed to obtain the basic data which can be applied to the use of foaming mortars. The data was based on the properties of foaming mortars depending upon various mixing ratios and addings to compare those of cement mortar. The foaming agents which was used at this experiment were pre-foamed type and mix-foaming type which is being used as mortar structures. The foaming mortar, mixing ratios of cement to fine aggregate were 1:1, 1: 2, 1 : 3 and 1 : 4. The addings of foaming agents were 0.0%, 0.5%, 1.0%, 1.5%, 2.0%, 2.5% and 3.0% of cement weight. The results obtained were summarized as follows; 1. At the mixing ratio of 1 : 1, the lowest water-cement ratios were showed by foaming mortars, respectively. But it gradually was increased in poorer mixing ratio and decreased in more addition of foaming agent. The water-cement ratios were decreased up to 1. 8~22. 0% by G, 2. 2~24. 1 % by U and 0. 7~53. 1% by J foaming mortar than cement mortar. 2, At the mixing ratio of 1 : 1, the highest bulk densities were showed by foaming mortars, respectively. But, it gradually was decreased in poorer mixing ratio and more addition of foaming agent. The bulk densities were decreased up to 1. 4~20. 7% by G, 2. 3~23. 7% by U and 26. 5~56. 5% by J foaming mortar than cement mortar. Therefore, foaming mortar could be utilized to the constructions which need low strengths. 3. At the mixing ratio of 1:1, the lowest absorption rates were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. Specially, according to the absorption rate when immersed in 72 hours, the absorption rates were showed up to 1. 01~1. 24 times by G, 1. 03~1. 58 times by U and 1. 10~5. 91 times by J foaming mortar than cement mortar. It was significantly higher at the early stage of immersed time than cement mortar. 4. At the mixing ratio of 1:1, the lowest air contents were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. Air contents were contented up to 4. 0~17. 2 times by G, 5. 2~23. 2 times by U and 23. 8~74. 5 times by J foaming mortar than cement mortar. 5. At the mixing ratio of 1 : 1, the lowest decreasing rates of strengths were showed by foaming mortars, respectively. But, it gradually was increased in poorer mixing ratio and more addition of foaming agent. Specially, the strengths of 28 days were decreased 0. 4~2. 2% than those of 7 days by foaming mortar, respectively. Also, the correlations between compressive and tensile strength, compressive and ending strength, tensile and bending strength were highly significant as a straight line shaped, respectively. 6. The correlations between absorption rate, air content, compressive strength and bulk density, absorption rate, compressive strength and air content were highly significant, respectively. The multiple regression equations of water-cement ratio, bulk density, absorption ate, air content, compressive strength, tensile strength and bending strength were computed depending on a function of mixing ratio and addition of foaming agent. It was highly significant, respectively. 7. At the mixing ratio of 1 : 1, the highest strengths were showed by cement mortar and foaming mortars, by chemical reagents. But, it gradually was decreased in poorer mixing ratio. The decreasing rates of strengths were in order of H $_2$S0 $_4$, HNO$_3$ and HCI, J,U,G foaming mortar and cement mortar. Specially, at the each mixing ratio, each chemical reagent and 3.0% of foaming agent, J foaming mortar was collapsed obviously. Therefore, for the structures requiring acid resistence, adding of foaming agent should be lower than 3.0%.

  • PDF

Aquacell Process를 이용한 PMMA의 발포 (Aquacell Foaming Process On PMMA)

  • 이현주;차성운;윤재동
    • 한국정밀공학회지
    • /
    • 제16권9호
    • /
    • pp.18-24
    • /
    • 1999
  • Microcellular foaming is being researched as a method of maintaining and improving the mechanical characteristics of plastics as well as saving the material costs. This can not only improve the mechanical properties including impact strength of plastic by producing cells with the size of few ${\mu}$m diameters within the plastic, but also can save the material cost of plastic products with the general volumetric expansion of 2 to 10 times. But quite a long time is required for the gas to be absorbed in the plastic. Therefore consistent research should be done to reduce the saturation time of gas into the plastic and this paper provides the method of water microcellular foaming process as one of the methods using the high diffusivity of water. In addition, we can improve impact property of foamed plastic by using this method.

  • PDF

발포기술을 이용한 폐 LCD유리 여재의 수질정화능력 평가 (Evaluation of the Water Purification Efficiency of Waste LCD Glass Media by Using Foaming Technology)

  • 안태웅;최이송;오종민
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.369-376
    • /
    • 2010
  • The purpose of this study is to reprocess Waste-LCD(Liquid Crystal Display), to widely increase specific surface-area by foaming agent in the process of reprocessing and to use as a substrate of water treatment which is increased the ability of biological treatment, as well as to control non-point source pollutants produced by surface run off during rainfall with using this substrate, and to improve water quality of public watershed as developing substrate for water treatment to be able to purify second treated water which is exhausted at the wastewater treatment plant. The average removal efficiency of Waste-LCD that using the foaming technology was SS 71.2%, BOD 55.7%, COD 58.4%, T-N 29.5% and T-P was 50.3%. Almost Media, early stage showed low removal efficiency of SS and BOD. However, it became high when the microorganism adhered the Media. The variation of SS removal efficiency was high by inflow concentration of SS. The reason for the Media 4 showed high SS removal efficiency is that it has wide specific surface-area, and also it has a pore. All in all, it shows floating matter treatment ability not only inside but it also works outside of the substrate.

기포제(起泡劑)가 모르터의 특성(特性)에 미치는 영향(影響) (Effects of Foaming Agent on the Characteristic of Mortar)

  • 김성완;강신업;조성섭;성찬용
    • 농업과학연구
    • /
    • 제11권1호
    • /
    • pp.133-145
    • /
    • 1984
  • 본(本) 연구(硏究)는 기포제(起泡劑)가 모르터의 특성(特性)에 미치는 영향(影響)을 연구(硏究)하기 위(爲)하여 기포(氣泡) 모르터의 물-시멘트 비(比)시험(試驗)과 밀도시험(密度試驗)을 배합별(配合別), 기포제별(起泡劑別)로 실시(實施)하였으며, 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 물-시멘트비(比)는 배합비(配合比) 1 : 4, G, U 및 J 기포제(起泡劑) 첨가량(添加量) 0.5%에서 90.0%, 88.3% 및 70.0%로 가장 크게 나타났으나, 보통(普通)모르터의 물-시멘트비(比) 91.6%보다는 작게 나타났다. 2. 물-시멘트비(比)의 감소율(減少率)은 보통(普通)모르터에 비(比)하여 G 및 U 기포(氣包)모르터에서 배합비(配合比) 1 : 3, 기포제(起包劑) 첨가량(添加量) 3.0%일 때 22.0%와 24.1%로 가장 크게 나타났고, 이 보다 부배합(富配合)이나 빈배합(貧配合)일수록 작게 나타났다. 또한 J 기포제(起包劑)에서는 배합비(配合比) 1 : 4, 기포제(起包劑) 첨가량(添加量) 3.0%에서 물-시멘트 비감소율(比減少率)이 53.1%로 가장 크게 나타났고 이보다 부배합(富配合) 일수록 작게 나타났다. 3. 밀도(密度)는 배합비(配合比) 1 : 1, G, U 및 J 기포제(起包劑) 첨가량(添加量) 0.5%에서 $1.981g/cm^3$, $1.863g/cm^3$$1.149g/cm^3$로 가장 크게 나타났으나, 보통(普通)모르터의 밀도(密度) $2.048g/cm^3$보다는 작게 나타났다. 4. 밀도(密度)의 감소율(減少率)은 보통(普通)모르터에 비(比)하여 G, U 및 J 기포(氣泡)모르터에서 배합비(配合比) 1 : 2, 기포제(起包劑) 첨가량(添加量) 3.0%일 때 20.7%, 23.7% 및 56.5%로 가장 크게 나타났으나, 이보다 부배합(富配合)이거나 빈배합(貧配合)일수록 밀도(密度)의 감소율(減少率)은 작게 나타났다. 5. 물-시멘트비(比)와 밀도(密度)는 기포제(起泡劑)의 첨가량(添加量)이 증가(增加)할수록 감소(減少)되었으며, 또한 배합비(配合比)와 기포제(起包劑) 첨가량(添加量)에 따라 물-시멘트비(比)와 밀도(密度)를 추정(推定)할 수 있는 다중회귀방정식(多重回歸方程式)도 유도(誘導)되었다.

  • PDF

무용제형 저기포성 정련제의 제조 및 정련특성 (Preparation of Solvent-Free Low Foaming Scouring Agents and Their Scouring Characteristics)

  • 박홍수;안성환;심일우;조혜진;함현식;김영찬;김성길
    • 한국응용과학기술학회지
    • /
    • 제23권1호
    • /
    • pp.37-44
    • /
    • 2006
  • Solvent-free low foaming scouring agents (LFSC) were prepared by blending of 2-ethylhexylaminoethyl sulfate (2-EHAS), POE(10) octadecylbenzyl- ammonium chloride (POBAC) and Sedlan FF-200 (FF-200). As the results of several tests, 2-EHAS/POBAC/FF-200/water (8g/12g/20g/60g) mixture (LFSC-5) showed good cleaning power, penetrating ability and stability to alkali, and gave less problem in water pollution. The foaming power of LFSC-5 measured by Ross and Miles method was 8mm foam height immediately after foaming, and that measured by Ross and Clark method was less than 300mm foam height at $30^{\circ}C$, and 18mm at $80^{\circ}C$. As a result, LFSC-5 proved a good low foaming scouring agent for fiber.

목질폐재를 이용한 식물식재용 우레탄폼의 개발 (Development of Urethane Foams for Planting Media from Woodwastes)

  • 조남석;서원성;한규성
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권4호
    • /
    • pp.43-49
    • /
    • 1998
  • The availability of large quantities of waste woods provides an impetus for investigating woody biomass potential uses. Polyurethane (PU) foams are prepared with reacting isocyanates and polyols, and are used. in various industry fields. Thus, lignocellulosic waste raw-materials are proposed as replacement for synthetic polyol to PU foam formulation. In this study PU foams were manufactured from liquefied woods, methanediisocyanate(MDI), catalyst, foaming stabilizer, and viscosity aids. The polyol content, isocyanate.hydroxyl group (NCO/OH) ratio, and water content were varied to evaluate their effects on the foaming and water absorption of the PU foams. Less than 400 Molecular weight. of polyethylene glycol(PEG) and 1 to 3 solvent to woody raw-material ratio were desirable for liquefying woody materials. Liquefying rate was increased with more than 3 % addition of inorganic and organic catalysts and raising reaction temperature more than $150^{\circ}C$. Addition of starch enhanced liquefying of woody materials. Fourty percents of starch resulted in about 90% liquefying rates. Foaming rates were increased with increasing moisture contents of liquefied wood. Moisture contents of 0.6% resulted in 5 time-foaming rates, and seven percents of moisture contents more than 30 time-foaming rates. But, an increase in water content may result in a decrease in cross-links between wood polyol and isocyanate, because the NCO/OH ratio is constant. Increasing moisture contents have significantly decreased density of PU foams. The optimum water content should be about 2.5% or less in this adopted condition.

  • PDF