• 제목/요약/키워드: water flow rate

검색결과 3,041건 처리시간 0.031초

농업용 저수지의 하한 관리 저수율 설정에 따른 농업용수 및 환경용수 공급 가능성 고찰 (A Study on the Potential of Agricultural Water and Environmental Flow Supply according to Regulating Lower Control Storage Rate for the Irrigation Reservoir)

  • 정지연;정민혁;범진아;박민경;이재남;유승환;윤광식
    • 한국농공학회논문집
    • /
    • 제65권2호
    • /
    • pp.21-33
    • /
    • 2023
  • While the main purpose of irrigation reservoirs is to supply agricultural water, the needs of environmental flow and flood control has been expanded. The agricultural reservoirs have been operated in the form of carry-over system until now. Therefore, the supply of agricultural water is difficult when the storage rate is not sufficiently secured after large volume of irrigation. In addition, there are regulation of the upper storage rate for some large reservoirs during the flood season, but lower storage rate is not regulated. Accordingly, this study aims to evaluate the capacity of agricultural water and environmental flow supply by setting the management lower storage rate of reservoir. The changes in the supply of agricultural and environmental flow was simulated according to the three different regulating lower storage rate scenarios. As a result, it was judged effective in terms of water supply managing the lower storage rate up to 30% when the initial storage rate of farming period is above annual average for the Naju reservoir considering existing water management practice. If the lower storage rate would have been controlled above 30%, the supply of agricultural water might be increased and non-effective discharge amount would be decreased compared to other scenarios during dry period of 2016-2018.

열수 주입법에 의한 메탄가스 하이드레이트 펠릿의 해리 특성에 관한 실험 연구 (Experimental Study on the Dissociation Characteristics of Methane Hydrate Pellet by Hot Water Injection)

  • 이승한;윤용석;성관제
    • 대한기계학회논문집B
    • /
    • 제35권11호
    • /
    • pp.1177-1184
    • /
    • 2011
  • GTS 기술은 천연가스 하이드레이트 생산, 해양수송 및 재기화의 3 단계로 구성되며, 대규모 재기화 플랜트의 효율적 운용을 위해서는 하이드레이트 펠릿의 재기화에 필요한 열수 온도와 유량의 정확한 예측이 필수적이다. 하이드레이트 펠릿이 열수에서 해리할 때 펠릿 표면에서 분출되는 가스는 주변 유동장과 열전달 특성에 영향을 미칠 것이며 본 실험에서는 가압된 용기내의 중저온 열수에서 해리하는 메탄가스 하이드레이트 펠릿의 용해특성을 연구하였다. 해리과정 중 변화하는 펠릿 형상을 관찰하고 해리 완료시간을 측정함으로써 하이드레이트 전환율, 열수 온도 및 유동속도가 해리에 미치는 영향을 파악하였으며, 펠릿 표면에서 분출되어 상승하는 메탄가스 기포류가 유발한 2 차유동이 열전달률을 증가시켜 해리 완료시간이 단축됨을 확인하였다.

바닥복사 난방시스템의 공급온수특성에 따른 에너지 소비특성 연구 (The Effects of Hot Water Supply on Energy Consumption for Floor Radiant Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.32-38
    • /
    • 2019
  • In this study, the effect of hot water supply flow rates on energy consumption for radiant floor heating system in apartment were researched by computer simulation. The parametric study of different hot water supply flow rates was done with regard to energy performance and control characteristics, respectively. Also the effect of different hot water supply flow rates on the hot water supply temperatures is studied. As a result, energy consumption were reduced but the response time is increased by reducing the supply flow rate. And energy consumption can be saved by adjusting the hot water supply temperatures with different supply flow rates.

충청남도 산업단지의 오·폐수처리실태 분석 (Analysis on the Actual Conditions of Wastewater Treatment Facilities in Chungcheongnam-do Province Industrial Complexes)

  • 임봉수;김도영;이상진;오혜정
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.850-862
    • /
    • 2007
  • This study was carried out to survey the actual conditions of wastewater treatment facilities to obtain basic data for the management of wastewater from industrial complexes in Chungcheongnam-do province. Wastewater production flow per site area by watersheds was $49.2m^3/km^2/d$ for Sapgyoho, $8.1m^3/km^2/d$ for Anseongcheon, $5.7m^3/km^2/d$ for Seohae, and $2.9m^3/km^2/d$ for Geumgang. Sapgyoho showed 75% of the total production flow, which was the highest value, Geumgang showed 4% of total flow, which was the lowest value. Average total extra rate as production flow/capacity flow in the wastewater treatment facilities for industrial complex is 49%. Considering by watersheds, the extra rates of Seohae, Geumgang, Anseongcheon, and Sapgyoho, are 73%, 65%, 62%, and 33% respectively. This means that the design of capacity flow in wastewater treatment facilities was too large. Effluent concentration of wastewater treatment facilities did not exceed discharge limit mostly. The removal efficiency rate for water quality item was 90% in BOD, 70% in COD, 80% in SS, 30 to 80% in TN, and 20 to 90% in TP, so the organic removal was good, but the nutrient removal was low and interval of variation was high. The removal efficiency rate of the agricultural was industrial complexes is lower than the national and local complexes. The construction cost of the wastewater treatment facilities in Chungcheongnam-do was $1,756Won\;per\;m^3$, treatment cost was $189Won\;per\;m^3$, and they were about two times and 1.2 times higher than the nation-wide cost, respectively. The treatment cost consists of 39% for man power, 21% for chemical, 16% for power, 11% for sludge treatment, and 13% for others.

태양열 해수담수화 시스템을 위한 다중효용 담수기 개발 (Development of Multi Effect Distillation for Solar Thermal Seawater Desalination System)

  • 주홍진;황인선;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2011
  • This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with $3m^3$/day capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were $18^{\circ}C$ for sea water inlet temperature, $6m^3$/hour sea water inlet volume flow rate, $75^{\circ}C$ for hot water inlet temperature, 2.4, 3.6, and $4.8\;m^3$/hour for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce $3m^3$/day of fresh water. Based on the results of this study, It makes possible to secure economics of desalination system with solar energy which is basically needed development of high efficiency fresh water generator.

대향류와 평행류형 판형 증발기에서 운전방식에 따른 성능특성 분석 (Analysis of Performance Characteristics in the Counter and Parallel Type Plate Evaporator with Operating Methods)

  • 배경진;차동안;권오경
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.50-56
    • /
    • 2013
  • The analysis of performance characteristics was carried out in the plate type evaporator with counter and parallel flow. To investigate performance of evaporator with water inlet temperature and refrigerant mass flow rate were changed. As a result, when the inlet temperature of water is $8^{\circ}C$, capacity of parallel flow evaporator higher than counter flow is 0.35%. But as the inlet temperature of water rises from $8^{\circ}C$ to $16^{\circ}C$, capacity of counter flow type evaporator higher than parallel flow type is 0.12%, 0.27%, 1.1%, 1.6%, respectively. The findings showed that counter flow type evaporator has a larger capacity than those that were parallel flow type evaporator. As the refrigerant mass flow rate rises, capacity and pressure drop increases in the counter and parallel flow type evaporator.

FLOW-3D에 의한 파샬플륨 흐름 해석 (Flow Analysis of Parshall Flume Using FLOW-3D)

  • 오병동;김경호;이환기;안상도
    • 한국수자원학회논문집
    • /
    • 제37권5호
    • /
    • pp.375-386
    • /
    • 2004
  • 갈수량은 수자원의 개발 및 관리에 매우 중요한 인자중의 하나이다. 신뢰성 높은 갈수량을 측정하기 위해 한국수자원공사는 2000년도에 용담댐 시험유역에 5피트 규격의 파샬플륨을 설치하였다. 파샬플륨은 유량측정을 하기 위해 독특한 모양을 가지고 있으며, 부정확한 유량관측을 유발하는 퇴사문제를 거의 해결한 시설물이다. 본 연구에서는 3차원 CFD (Computational Fluid Dynamics) 모형으로 5가지 수위에 대해서 완전월류(free flow)시 파샬플륨의 유동을 해석하였다. CFD모형에 의해 산정된 결과와 ISO에 제시된 유량공식, USBR에 제시된 유량공식 및 수위-유량관계식으로 산정한 유량을 비교하였다. 그 결과 ISO와 USBR의 공식에 의해 산정된 유량은 거의 동일했으나, 3차원 CFD모형에 의한 유량은 경험공식에 의한 유량보다 9%정도 크게 나타났고 수위-유량관계식에 의한 유량은 경험공식에 의한 유량보다 16%정도 작게 나타났다.

다중관형 CO2 급탕열교환기의 열적성능에 대한 해석연구 (An analytical study on the thermal performance of multi-tube CO2 water heater)

  • 장근선;최연성;김영재
    • 한국산학기술학회논문지
    • /
    • 제17권8호
    • /
    • pp.23-30
    • /
    • 2016
  • 본 연구에서는 길이 4.5 m와 7.5 m의 다중관 $CO_2$ 급탕 열교환기의 열전달 및 압력강하 특성을 ${\epsilon}-NTU$ 방법을 사용하여 해석하고 결과를 기존의 실험 데이터와 비교하였다. 급탕 열교환기는 쉘측에 물이 흐르고 8개로 구성된 내부 튜브에 $CO_2$를 흐르게 하였으며 열전달 효율을 최대화하기 위하여 대향류로 설계하였다. 각 노드에 대한 물과 $CO_2$ 냉매의 유동에 대한 에너지 평형 방정식은 단면분할법을 이용하여 해석하였다. 열전달율 계산값은 실험값과 ${\pm}5%$ 범위 내에서 잘 일치하였다. 반면에 물의 출구온도는 물 유량이 증가함에 따라 거의 선형적으로 감소하며 계산값과 실험값은 ${\pm}3%$ 내에서 일치하였다. 결과에서 열전달율은 4.5 m와 7.5 m 급탕 열교환기 모두 물 유량 또는 $CO_2$ 입구온도가 증가함에 따라 거의 선형적으로 증가하였으며, 반면에 물 유량이 증가함에 따라 물의 출구온도는 선형적으로 감소하였다. $CO_2$ 압력강하 계산값과 실험값은 $CO_2$가 고유량일 때 5 % 내에서 잘 일치한 반면에 $CO_2$가 저유량일 때 실험값이 약 20 % 높게 나타났다.

물 순환 및 에어레이션용 에어리프트 펌프의 성능 (Performance of Airlift Pumps for Water Circulation and Aeration)

  • 오세경
    • 한국수산과학회지
    • /
    • 제25권6호
    • /
    • pp.529-537
    • /
    • 1992
  • 본 실험은 에어리프트 펌프의 펌핑 성능과 에어레이션 능력을 조사하기 위해 수행했다. 펌프로는 2, 3, 4, 6인치 내경의 PVC 파이프를 사용했으며 펌프의 길이는 34.5인치였다. 공기 공급장치로는 정격 1 마력의 불로워를 사용하였다. 공기 유량 계측은 유량 게이지(풍속계)를 사용하였으며, 공기 압력은 물이 펌핑될 때 수위 변화로 측정했다. 펌프에 의한 에어레이션 성능 시험은 표준 에어례이션 테스트 방법으로 수행했다. 그 때 펌프출구의 중심선의 위치는 물 표면으로부터 3인치 위가 되도록 설정하였다. 수중의 산소농도는 에어레이션율을 산출하기 위하여 측정되었다. 탱크 속에서 수위 설정은 에어리프트 점프의 위치를 상하로 변경시켜 조절했다. 그 결과 수면에서 펌프의 위치가 높은 상태에서 물의 토출양은 공기의 공급량이 증가함에 따라 감소했다. 물 토출량의 감소율은 4인치와 6인치 펌프에서 높았으며, 직경이 작은 펌프에서 감소율은 그 정도가 미미했다. 시간의 변화에 따라 측정한 각 펌프의 에어레이션 성능은 2인치 펌프를 제외하고 3, 4, 6인치 펌프에서 비슷한 결과를 보았다. 6인치 펌프는 점핑 수두를 최소로 했을 때 가장 우수한 물 순환 효과를 얻을 수 있었다.

  • PDF

공조장치내의 직렬-직렬 대향류 냉각기에서 최적 변수 (The optimal parameters in series-series counterflow chillers system within air conditioning)

  • 웬민푸;뷔옥훙;이근식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1332-1336
    • /
    • 2009
  • If water-chillers are arranged in series-series counterflow, compressor lift of each chiller will be decreased in comparison with water-chillers in parallel. That means that compressor power of the chillers in series will be lower than that of chillers in parallel. However, the pressure drop of the water flow through the chillers in series will increase, and thus increase the power of water pumps. This disadvantage will be made good by increasing the temperature difference of water flow through evaporator and condenser, but the water flow rates will decrease. This paper explores the optimal parameters in system of series-series counterflow for central chilled water plants such as the leaving chilled water temperature, the leaving condenser water temperature, condenser water flow rate and number of chillers in series.

  • PDF