• 제목/요약/키워드: water faucet

검색결과 28건 처리시간 0.029초

고층 주거건물 급수$\cdot$급탕설비의 사용실태에 관한 조사연구 (A Study on the Practical Use Status of Cold & Hot Water Supply System in High-rise Residential Buildings)

  • 석호태;김장한;차민철;조경재;여명석
    • 한국주거학회논문집
    • /
    • 제16권2호
    • /
    • pp.75-82
    • /
    • 2005
  • The High-rise Residential Buildings are recently consuming a lot of energy because of the vertical height rise in case of supplying cold and hot water. It is required to a appropriate solution in occurring discomfortable use and unexpected conditions of High-rise Residential Buildings on account of the difference of water supply pressure on top and bottom floor, faucet outlet pressure rise. Thus, the purpose of this study is to research on practical use status of Cold and Hot Water Supply System through Question Survey in High-rise Residential Buildings and to analyze problems.

간호사의 손씻기에 대한 지식 및 태도 연구 (A Study on Handwashing Knowledge and Attitudes of Nurses)

  • 임현자
    • 간호행정학회지
    • /
    • 제2권2호
    • /
    • pp.5-16
    • /
    • 1996
  • The purpose of this study is to identify the handwashing knowledge and attitudes of resistered nurses on general wards. Subjects for this study include 182 nurses working in general wards of a hospital in Seoul area. Data were collected by a questionnaire from July 30 to August 10,1996. Statistical analyses were done by the SPSS/PC program. The techniques used in this sudy included frequencies, chi-square test. The results of this study are summarized as follows. 1. 34.6% of the respondents reported that they washed their hand an average of 5 to 7 times during the work day. 2. 38.5% of the respondents reported always washing after each patient contact. Only 9.9% always washed before contact with a patient. 3. 56.6% of the respondents reported a washing time of 10 to 20 seconds, whereas 29.1% washed 21 to 30 seconds. Chi-square tests were employed to determine any differences in handwashing frequency and duration by age, working years, work position. There were no satistically significant differences among the variables. 4. 95.6% of the subjects used water and plain soap during the washing process. The respondents washed the palms of the hands, the backs of their hands and between their fingers(33%). Only 17.6% removed rings before handwashing. Similarly, 11% removed their wristwatch. The majority(96.2%) reported that they used communal textile towel to dry their hands. When asked what method they used to turn off the water faucet after washing, 98.4% reported using direct hand-to-faucet contact. 5. Nursing activities that showed the highest handwashing rates was after wound dressing(22.9%), followed by suctioning(21.4%), injection(21.2%), inserting catheter(18%). 6. Reasons cited for reduced handwashing frequency included being too busy to wash more often(74.7%), no need to wash more often(11.0%) and dry skin caused by frequent handwashing(3.3%). 7. When asked where they obtained their current knowledge of handwashing techniques, they reported professors(73.6%), resisted nurses(14.8%) and supervisor(6.6%). 8. Nursing staff thought that proper handwashing was important factor in decreasing nosocomical infections(72.4%).

  • PDF

마이크로 용적형 수차의 개발에 관한 연구 (A Study on the Development of a New Micro Positive Displacement Hydraulic Turbine)

  • 이영호;최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.284-290
    • /
    • 2006
  • For the case of high head and critical low flow rate range of micro hydropower resources, it requires very low specific speed turbines which are lower than conventional impulse turbine's specific speed. In order to satisfy the request for very low specific speed turbine with high efficiency, a new positive displacement turbine is developed. The performance characteristics of the new turbine is tested and compared with a conventional impulse turbine, which is used for automatic water faucet system. The purpose of present study is to develop an high performance turbine that can be used to extract micro hydropower potential of a water supply system. The test results show that the positive displacement turbine is much more efficient than the conventional turbine and it can sustain high efficiency under the wide range of operating conditions. The pressure pulsations at the inlet and outlet of the positive displacement turbine can be considerably minimized by using simple pressure damper.

대학교 기숙사의 실내공기질 환경 개선에 관한 연구 (A Study on Environmental Improvement of Indoor Air Quality in University Dormitory)

  • 김호진;양정훈;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1398-1405
    • /
    • 2008
  • As the structure, material and construction of building develop continuously, so the recent residential buildings are being large, high-rise and group. High-rise residential buildings consume a lot of energy on supplying cold and hot water. As well, high-rise residential buildings bring on discomfortable use and unexpected conditions on account of faucet outlet pressure rise and the difference of water supply pressure between top floor and bottom floor. Thus, the purpose of this study is to research on using conditions of cold and hot water supply system through survey and field measurement in high-rise residential buildings and to analyze problems.

  • PDF

Evaluation of Microbiological Contamination of Water Purifiers at Two Universities in Chungcheong Region

  • Jin Young Yun
    • 대한의생명과학회지
    • /
    • 제29권4호
    • /
    • pp.256-262
    • /
    • 2023
  • The purpose of this study is to investigate microbial contamination in water purifiers from two universities (A and B) in Chungcheong region and to evaluate about the harmfulness of the isolated bacteria to the human. The degree of microbiological contamination of six water purifiers at university A was investigated three times from July 2018 to September 2019, and nine water purifiers at university B were investigated in 2023. The isolated bacteria were biochemically identified using an API kit and Vitek-2 system, and then the bacteria were identified to the species level using MALDI-TOF MS. In addition, the possibility of human infection of the isolated bacteria was evaluated through a literature search. In July 2018 and September 2019, the number of bacteria isolated inside the faucet was below the acceptable standard for hot water, but exceed for cold water in all water purifiers. In January and September 2019, bacteria exceeding the acceptable standards were isolated nine times from the cold water of six water purifies (a total of 12 water purifiers). Bacteria identified by MALDI-TOF MS included anaerobic bacteria (Clostridium novyi, Clostridium themopalmarium etc.), Gram-positive bacilli (Microbacterium testaceum, Arthrobacter woluwensis etc.), and Gramnegative bacilli (Acinetobacter nosocomialis, Comamonas kerstersii etc.), which are difficult identify by biochemical methods. In conclusion, bacteria exceeding the acceptable standard were isolated from the cold water of most of the water purifiers. Most of the isolated bacteria were low-pathogenic bacteria from natural environment, but opportunistic bacteria that can cause infection in humans were also isolated from some water purifiers.

Simulation of Contaminant Draining Strategy with User Participation in Water Distribution Networks

  • Marlim, Malvin S.;Kang, Doosun
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.146-146
    • /
    • 2021
  • A contamination event occurring in water distribution networks (WDNs) needs to be handled with the appropriate mitigation strategy to protect public health safety and ensure water supply service continuation. Typically the mitigation phase consists of contaminant sensing, public warning, network inspection, and recovery. After the contaminant source has been detected and treated, contaminants still exist in the network, and the contaminated water should be flushed out. The recovery period is critical to remove any lingering contaminant in a rapid and non-detrimental manner. The contaminant flushing can be done in several ways. Conventionally, the opening of hydrants is applied to drain the contaminant out of the system. Relying on advanced information and communication technology (ICT) on WDN management, warning and information can be distributed fast through electronic media. Water utilities can inform their customers to participate in the contaminant flushing by opening and closing their house faucets to drain the contaminated water. The household draining strategy consists of determining sectors and timeslots of the WDN users based on hydraulic simulation. The number of sectors should be controlled to maintain sufficient pressure for faucet draining. The draining timeslot is determined through hydraulic simulation to identify the draining time required for each sector. The effectiveness of the strategy is evaluated using three measurements, such as Wasted Water (WW), Flushing Duration (FD), and Pipe Erosion (PE). The optimal draining strategy (i.e., group and timeslot allocation) in the WDN can be determined by minimizing the measures.

  • PDF

상·하수 배관재의 수 환경에서 부식진전도 연구 (Research of Corrosion Growth Degree According in Liquid Environment of Waterworks and Sewer Piping Material)

  • 박경동;기우태;유형주;김동욱
    • 한국기계가공학회지
    • /
    • 제5권4호
    • /
    • pp.33-40
    • /
    • 2006
  • The quality of the supply water which is supplied to consumer is not the thing of water after filtrating but the thing of water from faucet through pipe. As a result, heavy metals and microorganism, that is the major materials, which cause the distrust of the supply water is generated by supply process. Especially, the heavy metal is generated by the corrosion of waterworks. Besides, rupture by corrosion of pipe becomes the factor of supply water's pollution in waterworks and the factor of pollution of the soil and environment in drain pipe. Therefore, this research examined the weight reduction electric potential measure to measure the corrosion degree of piping materials after testing the corrosion of piping materials(Copper Pipe, Galvanized Steel Pipe, Stainless Steel Pipe) which is generally used at the moment in various corrosion environments(subterranean water, supply water, 3.5% NaCl, 3.5% $HNO_3$). And let me show basic design data about problem occurrence such as leakage water, rust water, inside and outside corrosion from this.

  • PDF

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권4호
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.

관망해석을 통한 주거용 건축물의 급수.급탕 헤더시스템 설계 방안에 관한 연구 (A Study on the Design Method of Cold & Hot Water Manifold System for Residential Buildings through the Piping Network Analysis)

  • 차민철;석호태;김동우
    • 한국주거학회논문집
    • /
    • 제19권5호
    • /
    • pp.111-120
    • /
    • 2008
  • The aim of this study is to present the design methods about manifold location being installed and size and to draw out the proper piping size as comparing the fluctuation of discharge with manifold size and residence size through the piping network analysis, when using the same faucet in accordance. The findings are summarized as follows, 1) an appropriate header main body pipe diameter was deemed to be $32{\sim}50\;mm$. 2) the research presented design measures for the application of appropriate water supply inlet pipe diameters according to residential buildings with various sizes. 3) the header direct branch piping method is ideal for small and medium-sized residential complexes, and the header branching and semi header methods are deemed to be more favorable for large residential complexes. 4) this study offered design measures for appropriate header system main body pipe diameters, water supply inlet pipe diameters, header system piping methods, application methods for functional auxiliary equipment units, and header system installation spaces and location.

보건계열 대학생의 손 씻기 실태 (A study on handwashing of health science college students)

  • 강은주;최화정
    • 한국치위생학회지
    • /
    • 제13권3호
    • /
    • pp.449-456
    • /
    • 2013
  • Objectives : The objectives of this study were to investigate the handwashing and practice of health science college students and emphasize the importance of handwashing and infection control precaution to the students. Methods : This study was conducted by 586 health science college students through self-reported survey. All data were analyzed using SPSS/PC 13.0 program. Results : 1. Female students washed hands more frequently(7 times per day) than male students(6 times per day). Female students washed hands for 39 seconds in the meanwhile male students washed hands for 28 seconds. 2. Handwashing after using toilet accounted for 79.6% and 72.0% in female and male students, respectively. 3. Most of the handwashing was performed with faucet water (82.1%). The others were tepid water (54.3%), running water (98.1%) and water with soap bar (66.7%). 4. The reason for not practicing handwashing was due to annoyingness (36.3%). Conclusions : Health science college students' tended to wash their hands frequently. However, there existed a gap between the handwashing perception and practice in the previous reports because the observed practice was different from self-estimated perception.