• Title/Summary/Keyword: water exchange

Search Result 1,496, Processing Time 0.026 seconds

Mass Culture of Ultra-small Rotifer, Synchaeta kitina at the Exchange Rate of Culture Water and Initial Inoculation Density (환수율 및 접종밀도에 따른 초소형 rotifer, Synchaeta kitina의 대량배양)

  • Oh, Jeong-Soo;Park, Jin-Chul;Park, Heum-Gi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.4
    • /
    • pp.354-359
    • /
    • 2009
  • The productivity of ultra-small rotifer, Synchaeta kitina was investigated at the exchange rate of culture water (10, 20, 30, 40 and 50%) and initial inoculation densities (250, 600 and 900 inds. per mL) in semi-continuous culture. Also, the possibility of mass culture was investigated in a 100 L culture tank. Tetraselmis suecica was used as the feed for S. kitina in all experiments. The production of S. kitina increased with an increase in exchange rate of culture water. The highest production ($82.0{\times}10^5$ inds.) was achieved at 40% exchange rate of culture water. The production of S. kitina increased with an increase of initial inoculation density during the first week and the highest total production ($17.4{\times}10^6$ inds.) was achieved at 900 inds. per mL of initial inoculation density. However, on the second week, all treatments were not significantly different in total production (P>0.05). During the two weeks, total production of S. kitina at 900 inds. per mL of initial inoculation density was higher than at 600 inds. of initial inoculation density, but there was no significant difference (P>0.05). In the 100 L culture tank, density of S. kitina was kept from 516 to 890 inds. per mL and S. kitina was daily harvested $15.5{\times}10^6$ to $26.7{\times}10^6$ during the experimental period. The production cost for 100 million rotifers in semi-continuous culture was 63,656 won. The results from this study indicate that the optimal exchange rate of culture water and initial inoculation density for the semi-continuous culture of ultra-small rotifer, S. kitina are 40% and 600 inds. per mL, respectively.

Evaluation of Commercial Anion Exchange Membrane for the application to Water Electrolysis (수전해 시스템에 적용하기 위한 상용 음이온교환막의 특성평가)

  • Jun Ho, Park;Kwang Seop, Im;Sang Yong, Nam
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.496-513
    • /
    • 2022
  • In this study, we sought to verify the applicability of anion exchange membrane water electrolysis system using FAA-3-50, Neosepta-ASE, Sustainion grade T, and Fujifilm type 10, which are commercial anion exchange membranes. The morphology of the commercial membranes and the elements on the surface were analyzed using SEM/EDX to confirm the distribution of functional groups included in the commercial membranes. In addition, mechanical strength and decomposition temperature were measured using UTM and TGA to check whether the driving conditions of the water electrolyte were satisfied. The ion exchange capacity and ion conductivity were measured to understand the performance of anion exchange membranes, and the alkaline resistance of each commercial membrane was checked and durability test was performed because they were driven in an alkaline environment. Finally, a membrane-electrode assembly was manufactured and a water electrolysis single cell test was performed to confirm cell performance at 60℃, 70℃, and 80℃. The long-term cell test was measured 20 cycles at other temperatures to compare water electrolysis performance.

Optimized Ballast Water Exchange Management for Tanker (탱커선 전용의 최적화된 밸러스트수 교체 관리)

  • Hong, Chung-You;Chang, Hyeong-Joon;Kwon, Sung-Jin;Choi, Young-Dal;Kim, Dong-Eon;Park, Je-Woong
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.225-230
    • /
    • 2003
  • Many port states such as New Zealand, the USA, Australia and Canada have strict regulations to prevent ships which arrive in their port from discharging polluted ballast water which contain harmful aquatic organisms and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason, they perceived that the ballast exchange in deep sea is the most effective method, together with submitting the ballast management plan which contains the effective exchange method, ballast system and safety consideration. In this study, we make an effort to develop optimum ballast water exchange management and in result of that, it provide more convenient and stable process for preparing ballast water management plan.

  • PDF

Experimental Study on Heat Exchange Efficiency of Combined Well & Open-Closed Loops Geothermal System (지하수정호와 결합한 복합지열시스템의 열교환 효율에 대한 실험적 연구)

  • Song, Jae-Yong;Lee, Geun-Chun;Park, Namseo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.5
    • /
    • pp.43-50
    • /
    • 2018
  • The temperature of underground water generally remains constant regardless of the season. therefore, it is possible to get plenty of energy if we use characteristics of underground water for both cooling and heating. This study evaluates efficiency of real size coaxial and U-tube type complex geothermal system which is combined with underground water well. This study also evaluates relative efficiency/adaptability through comparison with existing geothermal systems(vertical closed loop system, open loop system(SCW)). The heat exchange capacity of complex geothermal system according to temperature difference between circulating water and underground water shows very high significance by increasing proportionally. The temperature change of underground water according to injection energy, shows very high linear growth aspect as injection thermal volume heightens. As a result of evaluation of heat exchange volume between complex geothermal system and comparative geothermal system, coaxial type has 26.1 times greater efficiency than comparative vertical closed type and 2.8 times greater efficiency than SCW type. U-tube type has 26.5 tims greater efficiency than comparative vertical closed type and 2.8 times greater than SCW type as well. This means complex geothermal system has extremely outstanding performance.

Research Trends in Bipolar Membrane for Water Dissociation Catalysts and Energy Technology Applications (바이폴라막의 물 분해 촉매 및 에너지 기술 응용의 연구 동향)

  • Do-Hyeong Kim;Sang Yong Nam
    • Membrane Journal
    • /
    • v.34 no.1
    • /
    • pp.10-19
    • /
    • 2024
  • The bipolar membrane is an ion exchange membrane consisting of a cation exchange layer, an anion exchange layer, and an interface layer, and is a membrane that generates protons and hydroxide ions based on water dissociation characteristics. Using these properties, research is being conducted in various application fields such as the chemical industry, food processing, environmental protection, and energy conversion and storage. This paper investigated the concept of bipolar membrane, water dissociation mechanism, and water dissociation catalyst to provide a comprehensive understanding of bipolar membrane technology, were investigated. Lastly, we also investigated the bipolar membrane process that has been recently applied to energy technology.

A Study on the Water Exchange Plan with Disaster Prevention Facilities in Masan Bay (마산만 재해방지시설을 이용한 해수교환 방안에 관한 연구)

  • Kim, Gweon-Su;Ryu, Ha-Sang;Kim, Kang-Min
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.637-645
    • /
    • 2013
  • Masan bay with a semi-enclosed waters has serious water quality problems due to the low flow and river pollution load from land, and shows the vulnerable locational characteristics to storm surge. We are seeking the way of both operating disaster prevention facilities and water quality improvement measures in the bay. That is, the water was exchanged using the head difference occurred by operating disaster prevention facilities. The location of disaster prevention facilities was assumed to be in the inlet of the bay, in the vicinity of Machang bridge, and in the vicinity of Dot island and the operation time was assumed to be early morning hours(01~05) considering the number of shipping passage and annual tide, and spring tide of the largest head difference. In addition, the experiment case of water exchange including the in-outflow feeder pipe was tested. According to the simulation results, water exchange rate in all experiments has shown a steady increase. Water exchange rate of the whole of Masan bay in the case of present is 38.62%. The water exchange rate of the inside of Masan bay compared with the inlet of bay, appeared to be very low. Thus, we judged that the characteristics of semi-enclosed waters were well reproduced. On the results of the experiment of disaster prevention facilities and in-outflow feeder pipe, the case of the operation of disaster prevention facilities, water exchage rate is high compared with the case of present. And, the higer the operating frequency, the more water exchange is appeared. The cases of water exchange prevention facilities through the in-outflow feeder pipe caused by the head difference, also showed the higest improvement of the water quality. Compared with the south of Machang bridge, the effect of water exchange was better in the inlet of Masan bay and Dot island. On the other hand, the inlet of Masan bay is higer than Dot island as for water exchange of the whole of Masan bay, but opposite, water change rate including Masan inside was higher in the case of Dot island.

The development of auto Ballast Water Management Plan For Bulk Carrier. (BULK선용 자동 Ballast Water Management Plan 개발)

  • Hong, Chung-You;Kwon, Young-Sub;Kwon, Sung-Jin;Hwang, Jin-Wook;Park, Je-Woong
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.266-271
    • /
    • 2003
  • Many port states such as New Zealand. the USA. Australia and Canada have strict regulations to prevent ships which arrive in their port from discharging polluted ballast water which contain harmful aquatic organism and pathogens. They are notified that transfer of polluted ballast water can cause serious injury to public health and damage to property and environment. For this reason. they perceived that the ballast exchange in deep sea is the most effective method. together with submitting the ballast management plan which contains the effective exchange method. ballast system and safety consideration. In this study, we make an effort to develop optimum ballast water exchange management and in result of that. it provide more convenient and stable process to prepare ballast water management plan for Bulk Carrier.

  • PDF

Treatment of $NH_3-N$ in Drinking Water Using Ion Exchange (이온교환을 이용한 음용수의 $NH_3-N$ 처리)

  • Chae, Yong-Gon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.1
    • /
    • pp.67-72
    • /
    • 2008
  • Ion exchange performance to remove Ammonium in water was studied using commercially available strong acidic cationic exchange resin of $Na^+$ type in the batch and continuous column reactors. The performance was tested using the effluent concentration histories for continuous column or equilibrium concentrations for batch reactor as a function of time until resins were exhausted or reached ionic equilibrium between resin and solution. The results shoed that cationic exchange resin used in this study was more effective than activated carbon or zeolite for ammonium removal. Ammonium removal with the ion exchange resin temperature to be high qualitative recording minuteness but increases about seasonal change of temperature was judged with the public law where the adaptability is excellent. When the pH comes to be high at 11 degree, the ammonium was not effectively removed.

Characteristics of Removal of Perfluorinated Compounds (PFCs) Using Magnetic Ion Exchange Resin (MIEX®) in Water (자성체 이온교환수지(MIEX®)를 이용한 수중의 과불화화합물(PFCs) 제거 특성)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Kim, Kyung-A;Ryu, Sang-Weoun;Kwon, Ki-Won
    • Journal of Environmental Science International
    • /
    • v.22 no.8
    • /
    • pp.1009-1017
    • /
    • 2013
  • Perfluorooctanoic acid (PFOA) and perfluorooctyl sulfonate (PFOS) is a new persistent organic pollutants of substantial environmental concern. This study investigated the potential of magnetic ion exchange resin (MIEX$^{(R)}$) as the adsorbent for the removal of PFOA and PFOS from Nakdong River water. In our batch experiments, we studied the effect of some parameters (pH, temperature, sulfate concentration) on the removal of PFOA and PFOS. The results of sorption kinetics on MIEX$^{(R)}$ show that it takes 90 min to reach equilibrium but the economical contact time and dosage were 30 min and 10 mL/L. An increase in pH (pH 6~10) leads to a decrease in PFOA (2.0%) and PFOS (3.6%) sorption on MIEX$^{(R)}$. The sorption of both PFOA and PFOS decreases with an increase in ionic strength for sulfate ion (${SO_4}^{2-}$), due to the competition phenomenon. An increase in water temperature ($8^{\circ}C{\sim}28^{\circ}C$) in water leads to a increase in PFOA (2.8%) and PFOS (4.3%) sorption on MIEX$^{(R)}$. Based on the sorption behaviors and characteristics of the adsorbents and adsorbates, ion exchange and hydrophobic interaction were deduced to be involved in the sorption, and hemi-micelles possibly formed in the intraparticle pores.

The Calcium and Magnesium Ion-Exchange Properties of Snythetic δ-Na2Si2O5 from Water Glass (Water Glass로부터 합성한 δ-Na2Si2O5의 Ca2+, Mg2+ 이온교환성)

  • Jeong, Soon-Yong;Suh, Jeong-Kwon;Park, Jeong-Hwan;Doh, Myung-Ki;Koh, Jae-Cheon;Lee, Jung-Min
    • Applied Chemistry for Engineering
    • /
    • v.5 no.3
    • /
    • pp.406-412
    • /
    • 1994
  • The ion-exchange properties of $Ca^{2+}$ and $Mg^{2+}$ ions have been studied in ${\delta}-Na_2Si_2O_5$ synthesized from water glass. Results show that optimum temperature for synthesis of ${\delta}-Na_2Si_2O_5$ was $725^{\circ}C$. Ion-exchange isotherms for $Ca^{2+}$ and $Mg^{2+}$ exchange for $Na^+$ in the synthetic ${\delta}-Na_2Si_2O_5$ show that the ion-exchange capacity of magnesium is better than that of calcium, and the ion-exchange of magnesium is less sensitive for temperature than that of calcium. When initial pH of solution is increased between 2 and 6, the ion-exchange capacities of magnesium and calcium decrease a little. However, they are almost constant above pH 6 because of alkali buffer effect of ${\delta}-Na_2Si_2O_5$. In the thermodynamic studies, it was found that Gibbs free energies of reaction of calcium ion-exchange are larger than those of magnesium ion-exchange with inverse order of selectivity. The standard enthalpy and entropy of reaction of calcium ion-exchange are larger than those of magnesium ion-exchange.

  • PDF