• 제목/요약/키워드: water evaluation

검색결과 7,069건 처리시간 0.032초

연약지반의 성토에 따른 과잉간극수압의 거동 (Behavior of Excessive Pore Water Pressure with Embankment on Soft Ground)

  • 김지훈;강예묵;이달원;임성훈
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.588-593
    • /
    • 1999
  • This study were performed to investigated the behavior of excessive pore water pressure with embankment of soft clay. The dissipation behavior of excessive pore water pressure in the improved and non-improved area was used to compare and alyze with lateral displacement , and to investigated the applicability of the methods for stability evaluatio of soft clay. The behavior of excess pore water pressure could be used to the fundamental data for stability evaluation, and the evaluation of the stability of embankment was recommended to use the indlination of curve rather than critical line.

  • PDF

항만의 해수교환 능력의 평가 지표 (Evaluation Index of Sea Water Exchange Capability of a Port)

  • 이정렬;김인호
    • 한국해양공학회지
    • /
    • 제18권6호
    • /
    • pp.22-28
    • /
    • 2004
  • A mathematical model has been developed to evaluate the capability of sea water exchanges under tidal and diffusive environments and has been verified through comparison with numerical experiments. From the mathematical analysis, this study presents the rates of sea water exchanges due to the tidal inflow and diffusion process. The port characteristic length $L_p$ is the most significant evaluation index.

고흡수성 수지와 기포콘크리트를 이용한 보수성포장용 보수재 성능 평가 (Evaluation of Characteristics of Water Retaining Material for Water Retaining Pavement using High Absorptiveness Resin and Foamed Concrete)

  • 이수형;유인균
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.321-324
    • /
    • 2008
  • Water retaining pavement is a pavement to lower the surface temperature by using evaporation of the water that the pavement contains when the pavement is heated by the sun in the daytime, so, to improve performance, the performance can absorb water. Most of the high-performance material that absorbs water swell $2\sim3$ times as much volume when it contact with water. Water retaining material exists independently of the material in the cement. so it doesn't have the space to expand. Therefore, the performance of absorbing water is decreased. Therefore, this study was to develop a foamed concrete and evaluation of performance characteristics using high absorptiveness resin. The result has been evaluated as excellent compared to other materials.

  • PDF

공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구 (An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom)

  • 이태강;고광필;김항;송국곤;김선우
    • 한국소음진동공학회논문집
    • /
    • 제18권6호
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.

하천수 이용 열원시스템의 경제성 평가 (Economic Evaluation on Energy System Using River Water)

  • 이철구;김종대;임태순;최명식;방승기;함흥돈
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권2호
    • /
    • pp.25-31
    • /
    • 2013
  • It has become very important for unused energy to be used for building air conditioning. Economic evaluation on energy system by using river water as a heat source, which is one of the unused energy, was carried out. The floor area of the building and the distance between heat source equipment and river was assumed $50,000m^2$ and 200 m. General heat source system using absorption chiller-heater was used for comparing to the energy saving system, and payback period method using initial cost and running cost of two systems, was used to perform economic evaluation. According to development of high capacity of water source heat pump which is appropriate for using river water, initial cost for the system has been reduced. Payback period was about 3.2 years, and this period might be shortened if nation's economic support enact.

Study on safety early-warning model of bridge underwater pile foundations

  • Xue-feng Zhang;Chun-xia Song
    • Structural Monitoring and Maintenance
    • /
    • 제10권2호
    • /
    • pp.107-116
    • /
    • 2023
  • The health condition of of deep water high pile foundation is vital to the safe operation of bridges. However, pier foundations are vulnerable to damage in deep water due to exposure to sea torrents and corrosive environments over an extended period. In this paper, combined with aninvestigation and analysis of the typical damage characteristics of main pier group pile foundations, we study the safety monitoring and real-time early warning technology of the deep water high pile foundations, we propose an early warning index item and early warning threshold of deep water high pile foundation by utilizing a numerical simulation analysis and referring to domestic and foreign standards and literature. First, we combine the characteristics of structures and draw on more mature evaluation theories and experience in civil engineering-related fields such as dam and bridge engineering. Then, we establish a scheme consisting of a Early Warning Index Systemand evaluation model based on the analytic hierarchy process and constant weight evaluation method and apply the research results to a project based on the Jiashao bridge in Zhejiang province, China. Finally, we verify the rationality and reliability of the Early Warning Index Systemof the Deep Water High Pile Foundations.

중.소도시 하천의 친환경적 활용 잠재력 평가에 관한 연구 -전남 순천시 하천을 사례로- (A Study on the Evaluation of Pro-environmental Potential of Streams in Sunchon City)

  • 정정채;이상석
    • 한국조경학회지
    • /
    • 제26권1호
    • /
    • pp.96-112
    • /
    • 1998
  • This study aims to evaluate the potential of pro-environmental application(PEP) in streams conceptualized ecological conservation and recreational use to be in harmony with. The main content of research are to clarify the PEP, to establish the evaluation model, and to evaluate 3 streams(Dongchon, Seokhyunchon, Okchon) in Sunchon city. Researchers introduced 12 evaluation items(water quality, water quantity, vegetation-water area, vegetation conservation, streamscape, neighborhood landscape, stream width, optimum area, nearby landuse, facility in stream, distance from user, obstacle to acces) by 5 scales to evaluate the characteristics of natural and artificial factors in stream area and nearby area. Also to decide the weight of items, researchers surveyed the opinion of 22 landscape architects experienced stream-plan through delphi method. Lastly the pro-environmental potential on streams were calculated by the ecological potential and recreational potential indices to be standardized and indicidual sections in streams were divided 5 grades on the basis of PEP. The result of this study are as follows; 1) The evaluation model of PEP was constructed by 4 steps, such as the decision of weight, the measurement of scale, the calculation of potential indices, the gradation of individual sections in streams. 2) The ecological potential were highly influenced by natural factor such as water quality, vegetation conservation, vegetation-water area, but on the other hand the recreational potential were influenced by optimum area, distance from user, water quantity, obstacle to access. 3) The factors such as vegetation conservation, optimum area, nearby landuse, distance from user were function as discernment factors to evaluate relatively ecological and recreational potential. and water quality, water quantity, vegetation -water area, neighborhood landscape were acted as important items to decide PEP.

  • PDF

수량화II류이론을 활용한 상수도관로의 안전성 평가 모델 개발 및 적용성 평가 연구 (A Study on the Development and Applicative Estimation of Safety Evaluation Model for Water Supply Pipelines using Quantification Theory Type II)

  • 김기범;신휘수;서지원;구자용
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.59-67
    • /
    • 2016
  • Owing to time and cost constraints, new methods that would make it possible to evaluate the safety of the water supply pipeline in a less time- and cost-consuming manner are urgently needed. In response to this exigency, the present study developed a new statistical model to assess the safety of the water supply pipeline using the quantification theory type II. In this research, the safety of the water supply pipeline was defined as 'a possibility of the pipeline failure'. Quantification analysis was conducted on the qualitative data, such as pipe material, coating, and buried condition. The results of analyses demonstrate that the hit ratio of the quantification function amounted to 77.8% of hit ratio, which was a fair value. In addition, all variables that were included in the quantification function were logically valid and demonstrated statistically significant. According to the results derived from the application of the safety evaluation model, the coefficient of determination ($R^2$) between K-region's water supply pipeline safety and the safety inspection amounted to 0.80. Therefore, these findings provide meaningful insight for the measured values in real applications of the model. The results of the present study can also be meaningfully used in further research on safety evaluation of pipelines, establishing of renewal prioritization, as well as asset management planning of the water supply infrastructure.

우리나라 가상수량 산정방법의 적용성 평가 (Evaluation of Virtual Water Calculation Method in Korea)

  • 안재현;이재근;이승호;홍일표
    • 한국수자원학회논문집
    • /
    • 제43권6호
    • /
    • pp.583-595
    • /
    • 2010
  • 가상수(假想水, Virtual Water)란 일정량의 농산물, 축산물, 공산품과 같은 생산품 혹은 서비스 제공에 필요한 물의양을 뜻하는 것으로 1990년대 초반 Tony Allan 교수가 처음 제시하였다. 본 연구는 Chapagain and Hoekstra (2004)이 제시한 농축산물 및 공산품의 단위 가상수량 산정방법을 분석 및 적용하여 1998년부터 2007년까지 우리나라의 가상수 수출입량을 산정하였다. 또한 가상수 수출입을 국가간 정량화하는 방법론으로 물발자국(Water Footprint) 이론을 이용하였다. 그리고 2006년 우리나라 농작물 생산량에 단위 가상수량을 적용하여 수자원장기종합계획(건설교통부, 2006)의 농업용수 수요량과 비교함으로써 단위 가상수 사용의 적절성을 검토하였다. 연구결과 현재 우리나라는 연평균 320억 $m^3$의 가상수를 농축산물 및 공산품의 무역을 통하여 순수입하고 있으며 그 양은 지속적으로 증가추세를 보이고 있다. 생산되는 농작물의 가상수량과 농업용수 수요량의 차이는 약 6억 $m^3$으로서 전체 수요량이 약 160억 $m^3$인 점을 감안한다면 상대적으로 근소한 차이로서 본 연구에서 적용한 단위 가상수량 산정방법이 타당함을 입증하였다.

침지냉각 조건에 따른 닭 도체의 수분 흡수 및 감량 비교 (Comparison of Water Retention and Loss of Chicken Carcasses by Different Water Chilling Condition)

  • 이재청;김병기;전진안;임찬혁;김효선;이경우
    • 한국가금학회지
    • /
    • 제41권3호
    • /
    • pp.159-164
    • /
    • 2014
  • 본 실험은 닭고기 가공 공장별로 침지냉각에 따른 닭 도체의 수분 흡수율 및 감소율 그리고 신선도를 측정 비교하여 품질의 균일화 제고를 위하여 실시하였다. A도계장과 B도계장 닭고기 가공 공장에서 1회 각 40수씩 3회에 걸쳐 총 240수에 대하여 수분 흡수율 및 신선도를 측정하였으며, 수분 흡수율 실험이 완료된 도체에 대하여 개체 포장, 운송하여 실험실 냉장고($4{\pm}1^{\circ}C$)에 입고 후, 저장일별 수분 감소율 및 신선도를 측정하였다. 실험 결과, 수분 흡수율은 A도계장 4.8%, B도계장 4.2%로서 유의적인 차이는 발견되지 않았다. B도계장 실험 도체의 신선도가 냉각 전후 모두, A도계장 실험 도체보다 신선도가 유의적으로 높게 조사되었다. 저장일별 수분 감소율은 A도계장 실험 도체와 B도계장 실험 도체 사이에 유의적인 차이는 나타나지 않았다. 저장일별 신선도는 A도계장 실험 도체가 B도계장 실험 도체에 비해 낮게 조사되었다. 결론적으로 수분 흡수율은 chiller의 길이나 침지시간에 크게 영향을 받지 않으나, 수분 감소율은 침지 시간, 수온 및 심부 온도의 영향을 받는 것으로 예측되었다.