• Title/Summary/Keyword: water dispenser

Search Result 13, Processing Time 0.023 seconds

Water quality analyses between tap water and treated water by point-of-use water dispenser systems (정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석)

  • Park, Keun-Young;Park, Ji-Won;Kim, Jae-Hyeok;Na, Yeong;Maeng, Sung-Kyu;Kim, Sung-Pyo;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

Development of Cold Water Dispenser using TEC Module (열전소자를 이용한 냉수기 개발에 관한 연구)

  • Lee, W.H.;Jung, S.W.;Koo, K.W.;Lee, M.S.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1566-1569
    • /
    • 1997
  • In this paper, we developed newer cooling system which has better efficiency and make smaller pollution than older cooling system compressor type by using TEC Module. And then we investigated application of Peltier Effect cooling technology applied to the cold water dispenser.

  • PDF

The Hazard of Ignition on the Bimetal Type Thermostat Molded by Phenol Resin (페놀수지로 몰딩된 바이메탈식 서모스탯의 발화위험성)

  • Park, Y.G.;Lee, S.H.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.63-73
    • /
    • 2007
  • In this paper, we discussed the hazard of ignition on the bimetal type thermostat molded by phenol resin with case study and accelerated aging test. We experimented three type thermostats molded by phenol resin which are used on hot/cold water dispenser. On the case study, the thermostat was origin of 6re and dry tracking occurred around it's moveable contactor. On the accelerated aging test, the more thermostat was switched, the more damaged it become. One of the A-type thermostats that is similar type on the case study fired around moveable contactor. We therefore confirmed that the tracking around the moveable contactor of bimetal type thermostat molded by phenol resin could be origin of fire and it is available to reduce of fire that using noncombustible material for molding of bimetal type thermostat.

  • PDF

Distribution and Characteristics of Heterotrophic Plate Count Bacteria in Water Samples from Drinking Water Dispensers (냉온수기에서 일반세균의 분포 및 분리한 세균의 특성)

  • Lee, Eun-Hwa;Koh, Ji-Yun;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.244-250
    • /
    • 2008
  • To evaluate bacteriological water quality, samples were taken from drinking water dispensers placed at S company (S-C) and U highschool (U-H) in Ulsan. The medians of heterotrophic plate counts (HPCs) were 53 CFU/ml for the 74 water samples of S-C and 80 CFU/ml for the 36 cold water samples of U-H, and 38% of the S-C and 42% of the U-H samples showed HPC bacterial concentrations higher than 100 CFU/ml. Coliform bacteria were detected from one sample of S-C. To determine the major source of bacterial contamination, water samples were taken daily for $6\sim8$ days from the bottled water containers as well as the faucets of an experimental water dispenser. While the average HPCs in the bottled water containers were 33 CFU/ml for the first and 132 CFU/ml for the 2nd analysis, the HPC concentration in the cold water samples was 1,022 CFU/ml for the 2nd analysis. These results suggest that the majority of bacteria detected in the cold water samples were originated from the biofilms on the surface of water passages within the water dispensers. There was no significant increase in HPC bacterial concentrations within the bottled water container after installation on the water dispenser. We could isolate and tentatively identify 3 genera 6 species of Gram-positive and 7 genera 7 species of Gram-negative bacteria from the plate count agar plates of U-H samples. Among the isolates, 72% were observed as Gram-positive, and Micrococcus spp. was the most abundant with 54% of the total, followed by Sphingomonas paucimobilis with 16%. It appears that most of the HPC bacteria detected in water dispensers originate from indoor airborne bacteria, which may play important roles in the formation of biofilms on the surface of water passages within the water dispensers.

Design and Fabrication of Doctor Blade Type Dispensers for Uniform Resin Coating during Roll to Roll Imprinting Process (롤투롤 임프린트 공정 중 균일한 레진 코팅을 위한 닥터블레이드형 디스펜서 설계 및 제작)

  • Son, Hee Chul;Kim, Seong Woo;Lee, Jihoon;Park, Cheol Woo;Kwak, Moon Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.10
    • /
    • pp.897-902
    • /
    • 2015
  • This study reports on a uniform resin coating method by using a doctor blade type dispenser. For high productivity, continuous imprint-lithography has been studied, and developed fabrication systems are used in several applications such as anti-reflection films, dry adhesives, and water collecting surfaces. In the continuous fabrication field, researchers have typically focused on patterning and demolding procedures. During the roll-to-roll fabrication process, however, the uniform resin coating process is also important in order to obtain a high quality product, which can be evaluated by uniform thickness, precise geometric expressions, and a thin residual layer. To achieve these, a doctor blade type dispenser was designed and fabricated. As a result, thickness of coated resin was well controlled by modulating the flow rate of the resin and blading gap. In addition, a very thin layer coating process (${\sim}10{\mu}m$) was achieved by softly contacting the blade on the substrate.

Development of a Novel System for Measuring Sizing Degree Based on Contact Angle(I) - Development of a Novel Principle for Automatic Measurement of Contact Angle - (접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제1보) -자동 접촉각 측정 원리의 개발 -)

  • 이찬용;김철환;최경민;박종열;권오철
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.3
    • /
    • pp.43-52
    • /
    • 2003
  • The new principle to measure a sizing degree by a contact angle was developed using an automatic determination of the 3-end point coordinates of the water droplet on a sheet, which could diminish the operator's bias during measurement. A constant amount of water was first placed on a sample sheet by a water dispenser, and then an image of the liquid droplet was captured by a digital camera and then transmitted to a computer. The program measuring for contact angle extracted a liquid contour by Gaussian function combined with a 8-direction chain code. The Euclidean equation was applied to the binary image of the liquid contour in order to measure the diameter of the contour. Finally, the contact angle of the liquid was calculated by using the diameter and the top coordinates. In addition, a surface free energy of the sample sheet and an elapsed time taken up to the complete absorption into the sheet were simultaneously measured with the contact angle.

A Case Study of Measuring and Analyzing Electric Energy Usage in University Facilities Using Smart Plug (스마트플러그(IOT)를 이용한 대학시설의 전기에너지 사용량 계측 및 분석 사례 연구)

  • Park, Jun-Young;Lee, Chun-Kyong;Park, Tae-Keun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.9
    • /
    • pp.27-34
    • /
    • 2018
  • The purpose of this study is to demonstrate and analyze the function of a Smart Plug before and after it is applied on the electrical appliances by controlling standby power usage. The research measures and analyzes the amount of electrical energy used while activating the Smart Plug with two types of appliances in a university facilities. The smart plugs were applied into a Group 1 appliances (Multi-function device, computer, laptop, Air con) which completely hinder the standby power, and a Group 2 appliances (Refrigerator, cold and hot water dispenser) which does not completely hinder the standby powers due to the characteristics of the function. First, the total standby power saving of all electrical appliances (Group 1 and Group 2) using the Smart plug was measured as 4.59%. Second, the energy saving of the Group 1 products was analyzed as 26.43%. Third, the standby power saving of the air conditioners from mid October to early December was measured as 31.06%, during the seasons when air conditioning was not actively in use. The research indicates that all specified appliances did have better energy efficiency with the Smart plug regardless of the amount of energy usage.

A Case Study of the Relationship between the Defects of resilient materials and the deviation of Light-weight Floor Impact Noise (완충재의 시공결함과 경량충격음 편차에 관한 사례 연구)

  • Seong, Yo-Han;Kim, Jin-Sik;Kim, Hye-won;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.137-138
    • /
    • 2023
  • The floating floor is a structure which introduced to reduce the noise of apartment houses. This structure can decrease vibration energy through resilient materials. However, it is limited to completely construct resilient materials in South Korea due to floor heating structure and other reasons. And It is a controversial issue how well the resilient materials should be constructed to prevent floor impact noise. These resilient defect areas are typically found in wall corners, door sills, hot water dispenser in kitchen and areas where thermal insulation is attached. This study investigates the acoustical effect of the defect areas in two ways. First, it is analyzed by several assumption conditions and calculated how much deviation would occur. Then we researched the deviation of the 76 field test data about light-weight floor impact noise. This study could be useful for a constructor to determine how much should minimize resilient materials defect areas.

  • PDF

Epidemiological Analysis of a Food Poisoning Outbreak Caused by Multiple Pathogens in a High School in Chungnam Korea, 2019 (2019년 충남지역 고등학교에서 발생한 다병원체에 의한 집단식중독의 역학적 분석)

  • Lee, Hyunah;Choi, Jihye;Park, Seongmin;Nam, Hae-Sung;Choi, Jinha;Park, Junhyuk
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.5
    • /
    • pp.434-442
    • /
    • 2019
  • Objectives: This study was performed in order to report the epidemiological features of a food poisoning outbreak caused by multiple pathogens in a high school in Chungcheongnam-do Province, Korea in April 2019 and to suggest measures to prevent a similar incidence. Methods: A total of 39 patients with diarrhea were examined. Environmental samples were obtained from 6 food handlers, 4 food utensils, 72 preserved foods served during the food poisoning outbreak, 9 door handles, 10 drinking water samples from water dispensers, and 6 ground water samples from water taps. These analyzed to detect viruses and bacteria. Results: Among the 39 patients, 21 cases (53.8%) of enteroaggregative E. coli (EAEC), 7 cases of Staphylococcus aureus (17.9%), and 17 cases of norovirus (43.6%) were positive, and in 16 of the cases a co-infection with at least one other pathogen were observed. EAEC was assumed to be transmitted from contaminated drinking water because it was also detected in the water sample from a water dispenser in the dormitory. Staphylococcus aureus was isolated only in the fecal samples of patients, meaning it was not possible to trace its origin. The genotype of norovirus detected in the drinking water and ground water was consistent with that isolated from patients, and it was determined that the norovirus infection originated from the school's water environment. Conclusions: These findings indicate that a lack of environmental hygiene management related to school meals caused the food poisoning incident. In particular, a lack of management of drinking water, water supply, and personal hygiene should be pointed out. This should be urgently addressed and continuous monitoring should be carried out in the future. In addition, students and staff should be educated and trained to improve their personal hygiene.

Comparative Crude Oil Productions on Liquefaction of Crop Residues (액화기술 적용 식물체 잔사별 원유 생산량 비교)

  • Shin, JongDo;Yoon, SunCheol;Paek, Yee;Park, SangWon;Choi, HongLim
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.4
    • /
    • pp.50-56
    • /
    • 2008
  • Aqueous thermal liquefaction of rice, barley, wheat, and rapeseed straws was investigated to compare the amount of heavy oil with catalysts such as $K_2CO_3$, NaOH and KOH in the reaction temperature at $320^{\circ}C$ for 10 minutes. The reaction was carried out in a 5,000ml liquefaction system with dispenser and external electrical furnace. Raw materials (160g), 2,000ml of distilled water and 10% (wt/wt) of catalyst to plant residue were fed into the reactor. It was observed that the maximum heavy oil yield was about 29% from the feeding stock, barley straw, with addition of KOH. The caloric values of crude oil from different crop residues were ranged from 55% to 66% relative to the raw materials depend on crop residue. It was appeared that its maximum calorific value from wheat straw was approximately 6190 kcal/kg.

  • PDF