• Title/Summary/Keyword: water corrosion

Search Result 1,466, Processing Time 0.033 seconds

Study on Cause and Effect of SG Feed Water Ring Through-Wall Hole (증기발생기 급수링 관통손상 원인 및 영향 고찰)

  • Lee, Sung Ho;Lee, Yo Seob
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.61-68
    • /
    • 2015
  • The function of Feed Water Ring is to provide the flow path from Feedwater Nozzle to inside of SG(steam generator). Significant amounts of general FAC on the outside of the Feed Water Ring are not likely due to the low flow velocities in this area. However, on the interior of the Feed Water Ring, there may be areas of local higher flow velocity which could lead to higher FAC rates. These may include the inlet tee from the Feedwater Nozzle into the Feed Water Ring, the areas where the Feed Water Ring changes diameter, and especially the entrance area to the J-Nozzles. In this paper, the results of root cause analysis of through-wall hole observed at domestic WH 51F SG Feed Water Ring and its effect on the integrity and performance of SG are described. And, the maintenance strategy for WH 51F SG Feed Water Ring and the monitoring strategy for Downcomer Feed Water Ring of CE System 80 SG are presented.

A Study on Corrosion Fatigue Crack Propagation Behaviors due to a Single Overload in 6063-T5 Aluminum Alloy (6063-T5 알미늄 합금의 단일과대하중에 의한 부식피로균열진전거동에 관한 연구)

  • 강동명;우창기;이하성
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.38-44
    • /
    • 1997
  • 6063-T5 alloys are tested in laboratory air, water and 3% NaCl solution to investigate the effects of corrosive environment on the retardation behavior through single overload fatigue test. Also, the fatigue crack propagation and the crack closure behavior are studied. The results obtained in this experimental study are summarized as follows. 1) Behaviors of fatigue crack growth retardation are observed in water and 3% NaCl solution as they do in air. The number of delay cycles and the size of affected region by single overload decrease greatly in water and 3% NaCl compared with those in air. 2) In fractographic results, the overload marking by single overload appear remarkably in air, but indistinctly in water and 3% NaCl solution. 3) The effect of crack closure on crack propagation is most remarkable in the beginning of crack propagation. With crack propagation, the crack closure level and its effect decrease greatly.

  • PDF

Fouling Analyses of Heat Exchangers for PSR (주기적안전성평가를 위한 원전 열교환기 Fouling 평가)

  • Hwang, K.M.;Jin, T.E.;Han, S.G.;Kim, B.S.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1467-1472
    • /
    • 2003
  • Fouling of heat exchangers is generated by water-borne deposits, commonly known as foulants including particulate matter from the air, migrated corrosion produces; silt, clays, and sand suspended in water; organic contaminants; and boron based deposits in plants. This fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. This paper focuses on fouling analyses for six heat exchangers of two primary systems in two nuclear power plants; the regenerative heat exchangers of the chemical and volume control system and the component cooling water heat exchangers of the component cooling water system. To analyze the fouling for heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. Based on the results of the fouling analyses, the present thermal performances and fouling levels for the six heat exchangers were predicted.

  • PDF

Fretting Wear and Friction of lnconel 690 for Steam Generator Tube in Elevated Temperature Water

  • Lee, Young-Ze;Lim, Min-Kyu;Oh, Se-Doo
    • KSTLE International Journal
    • /
    • v.3 no.1
    • /
    • pp.49-53
    • /
    • 2002
  • Inconel 690 for nuclear steam generator tube has more chromium than the conventionally used Inconel 600 in order to increase the corrosion resistance. TD evaluate the tribological characteristics under fretting condition the fretting tests as well as sliding tests were carried out in elevated temperature water environment. Fretting tests of the cross-cylinder type were done under various vibrating amplitudes and applied normal loads in order to measure the friction forces and wear volumes. Also, the conventional sliding tests of pin-en-disk type were carried out to compare the test results. In fretting, the friction was very sensitive to the load and the amplitude. The friction coefficient decreased with increasing load and decreasing amplitude. Also, the wear of Inconel 690 can be predictable using the work rate model. Depending on normal loads and vibrating amplitudes, distinctively different wear mechanisms and of ten drastically different wear rates can occur. It was fecund that the fretting wear coefficients in water were increased as increasing the temperature of water.

An analysis on the cause of the under-potential in the Electric Anti-corrosion Section (전위미달구간 전기방식설비 보강사례에 대한 연구)

  • Ha, Sung-Jong;Kim, Hyeon-il;Lee, Eun-Chun;Gil, In-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.709-710
    • /
    • 2015
  • 상수도관로 대부분의 구간이 PE 혹은 아스팔트 코팅된 강(steel)으로 제작되어 매설되어 있다. 강관이 토양중에 매설되어 있는 특성으로 인해 부식이 발생하게 되는데 이를 방지하기 위하여 희생양극식 및 외부전원식 전기방식법을 적용하여 보호하고 있다. 그러나 적절하지 못한 전기방식법 혹은 전기방식법의 미적용으로 인하여 부분적으로 상수도관은 부식 및 누수되는 구간이 존재하게 된다. 이에 각 방식전위 미달 구간에 대한 정밀한 진단을 통하여 적절한 방식 방안을 제시한 사례를 연구하여 향후 방식불량구간의 개선에 도움이 되고자 한다.

  • PDF

New Water-soluble Cutting Fluids Additives Derived from the Thermal Reaction Products of Unsaturated Fatty Acids with Acrylic Acid and Maleic Anhydride

  • Watanabe, Shoji
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.372-376
    • /
    • 2003
  • Water-soluble cutting fluids are used for processing of aluminium materials. This short article describes properties of new additives of water-soluble cutting fluids for aluminium materials. Various Diels-Alder adducts of unsaturated fatty acids with acrylic acid of maleic anhydride were prepared by thermal reactions. Triethanolamine salts of Diels-Alder adducts of dehydrated castor oil fatty acids with acrylic acid or maleic anhydride showed excellent anti-corrosion property of aluminium materals. These thermal adducts showed anti-rust property for cast-iron chips, too.

A Study on Scale Busting and Preventing Effect of Coating Ceramic Ball (코팅 세라믹볼의 방청효과에 관한 연구)

  • 하윤식;김학용;김수진;백우현
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1117-1123
    • /
    • 2002
  • Coating ceramic balls activate water molecular in water as radiate far-infrared radiation of high efficiency, and then prevent formation of scale and corrosion of pipe. Therefore, but only keep away drop of heat exchange efficiency of boiler, not also remove formed scale. As a result, pipe of boiler has clean and has form thin protection film in inner of pipe. Also, the water treated by rust preventing system using the ceramic balls, that is harmless, tasteless, odorless, and non-toxicity in the human body, and it can use drinking water. This rust preventing system can save energy and protect environment.

Effect of FeNi30 Powder Catalyst by Water Atomizing on Synthesis High-grade Diamond

  • Cheng, Dong-kai;Ma, Hong-qiu;Cao, Dan;Ding, Fu-chang
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.449-450
    • /
    • 2006
  • This paper described the preparation method for composing high-grade synthetic diamond by water atomizing using FeNi30 powder catalyst. The objective of this article is about powder making process using super high water atomizing in the atmosphere of inert gas, and then corroded the powder with a corrosion inhibitor. Finally, FeNi30 catalyst powder with lower oxygen content and good sphericity is produced. The experiment of making diamonds by using cubic press and the performance of the diamonds are also discussed.

  • PDF

Effect of Temperature and Water Assumtion on Strength of Spot Welded Zine Steel Plates (점용접 아연도금판의 강도특성에 대한 온도 및 침수의 영향)

  • Seo, Do-Won;Yoon, Ho-Chel;Choi, Jun-Yong;Lim, Jae-Kyoo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.358-363
    • /
    • 2003
  • Spot welded structure is operated in diverse situation because of temperature, humidity and precipitation. In addition factors of environmental pollution such as acid rain, that courses corrosion, have the tendency to increase, But spot welded structure strength is affected by dampness and environment temperatures. Therefore, it is important to evaluate effect of temperature of spot welded part, In this study, the strength distribution of spot welded plates is evaluated about the environmental temperature of zine coated steel plates and test is conducted with welded part immersed in distilled and synthetic sea water. Specimens are immersed into water for 10, 100, 500 and 1000hours to evaluate the effects of water immersion time on tensile-shear strength under the conditions of -40, 0, 20 and $50^{\circ}C$. Strength is evaluated by tensile-shear test. The conditions of spot welding are 240kgf electrode force, 10KA welding current with 0 and 5mm clearance. From this study, spot welded specimens with clearance have lower tensile-shear strength in the distilled water or synthetic sea water comparing with spot welded specimens without clearance. And they have lower tensile-shear strength under $-40^{\circ}C$ and over $50^{\circ}C$.

  • PDF

Improvement of tap water corrosivity by lime and carbon dioxide (액상소석회와 이산화탄소를 이용한 수돗물 부식성 개선)

  • Kim, Jinkeun;Lee, Junghoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.725-733
    • /
    • 2014
  • 16 water treatment plants(WTPs) in Jeju province were investigated to evaluate the corrosivity of tap water. In addition, the impacts of lime and carbon dioxide on LI changes at ES WTP were analyzed. The average of LI in Jeju tap was -1.78 which was similar to that of in-land multi-regional WTPs. The recommended process to improve LI of ES WTP which has high corrosivity(i.e., LI = -2.61) was to combine lime and carbon dioxide with the dosages of 20 mg/L and 5 mg/L respectively to meet LI of -1.0 ~ 0. pH was confirmed to be a major water quality parameter that determined LI based on the correlation results among LI and water quality parameters. Precaution on turbidity increase by lime addition should given to minimize particle breakthrough in the distribution system. Turbidity increase can be controlled by the addition of lime prior to filters.