• Title/Summary/Keyword: water corrosion

Search Result 1,466, Processing Time 0.03 seconds

Investigation of Durability of Electric Power Concrete Structures Exposed to Reclaimed Marine Land (해안매립지에 위치한 전력구 콘크리트 구조물의 내구성 조사)

  • Kim, Seong-Soo;Park, Kwang-Pil;Nam, Ba-Reum;Yoo, Ju-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.597-600
    • /
    • 2006
  • In Marine Land underground reinforced concrete structures, such as electric box power structure, water and chloride ion penetrated into concrete through the cracks of concrete and its permeable property, cause the corrosion of reinforcing steel bar, which accelerates the expansive cracks and deterioration of concrete. The purpose of this paper is to evaluate on deterioration of durability concrete through instrumental analysis such as schmidt hammer and carbonation, chloride content. Under the reclaimed marine land, the main cause of deterioration of concrete structures is the steel corrosion due to the penetration of chlorides and the deterioration of outer concrete itself by chemical attack.

  • PDF

Uniaxial Compressive Strength Characteristic of Shotcrete Immersed in Chemical Solution (화학적 침식에 의한 숏크리트의 압축강도 특성)

  • Lee, Gyu-Phil;Kim, Dong-Gyou;Bae, Gyu-Jin;Kim, Hong-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1291-1298
    • /
    • 2005
  • Shotcrete for the support of tunnel can contact with groundwater. The hazardous components in the groundwater cause the corrosion of shotcrete. Also, the hazardous components may deteriorate the engineering properties of shotcrete, such as compressive strength, bond strength, and flexural strength. The more the effect of the hazardous components on the shotcrete may increase, the more the stability of tunnel structure may decrease. It was analyzed to find the hazardous components in the ground water. The uniaxial compressive strength test, XRD, SEM were conducted to evaluate the durability and corrosion of shotcrete. These tests were performed on shotcrete specimens at 2, 4, 8, and 16 weeks. The specimens were immersed in various chemical solutions including hazardous components after the specimens were made at the construction site.

  • PDF

Chloride Ion Diffusion Characteristics of Fly ash. Concrete with Age (재령에 따른 플라이 애쉬 콘크리트의 염소이온 확산특성)

  • 이재호;이광명;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.681-686
    • /
    • 2003
  • One of the major degradation processes of reinforced concrete (RC) structure is corrosion of reinforced steel due to chloride attack. Severe environments, such as marine environment and exposure to de-icing salts, could accelerate the steel corrosion of RC structures through the chloride ion intrusion into concrete. In order to delay this degradation process, several kinds of admixtures have been used in concrete mix. In this study, effective diffusion coefficient of chloride ion ($D_{eff}$) and total passed charge of concrete with and without fly ash were measured using electrical method. It is found that fly ash concrete has much less chloride ion coefficient than ordinary concrete at later age. By analyzing the test results, $D_{eff}$ at 28 and 90 days was obtained as a function of water-binder ratio (W/B) and an equation for predicting $D_{eff}$ with age was proposed considering the decreasing rate of $D_{eff}$.

  • PDF

An Experimental study on durability improvement of concrete structures by a concrete coating method (도포공법에 의한 콘크리트 구조물의 내구성 증진에 관한 실험적 연구)

  • 조병완;문린곤;박승국;김대민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.721-726
    • /
    • 2003
  • The Durability of Concrete Structure is serverely degraded due to mainly carbonation, sulfate attack and chloride ion diffusion in concrete. The ultimate purpose of this study is to obtain how much the durability of Concrete Structure is improved according to the variation of physical properties in concrete or the frequency of surface coating on concrete. Where, variation of physical properties is a water-cement ratio or amount of air. The experiments are the chliride ion diffusion test, the lapid corrosion test, the lapid carbonation test, the test on resistance to freezing and thawing. Finally, this study shows that the effect by the surface coating method is better than the variation of physical properties in concrete.

  • PDF

A Study of fracture Mechanics Analysis Methodology for Stress Corrosion Cracks in Pressure Component Weld feints

  • Park, June-soo;Kim, Jong-Min;Pak, Jai-hak;Jin, Tae-eun
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.216-218
    • /
    • 2003
  • A fracture mechanics analysis methodology for stress corrosion cracks (SCCs) existing in the Alloy 600 nozzle weld joint for control rod drive mechanisms (CRDMs) of pressurized water reactor is studied. Effects of weld residual stresses on the sub-critical crack behavior during the reactor operation are investigated by a fracture mechanics analysis, which is combined with the finite element alternating method. It is found that effects f the residual stresses on the stress intensity factor (SIF) and crack growth rate (CGR) are dominant and values of SIF and CGR of cracks in the region of weld joint are increased by a factor of three or more on an average.

  • PDF

Bioinspired Nanoengineering of Multifunctional Superhydrophobic Surfaces

  • Choi, Chang-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.102-133
    • /
    • 2015
  • Nature, such as plants, insects, and marine animals, uses micro/nano-textured surfaces in their components (e.g., leaves, wings, eyes, legs, and skins) for multiple purposes, such as water-repellency, anti-adhesiveness, and self-cleanness. Such multifunctional surface properties are attributed to three-dimensional surface structures with modulated surface wettability. Especially, hydrophobic surface structures create a composite interface with liquid by retaining air between the structures, minimizing the contact area with liquid. Such non-wetting surface property, so-called superhydrophobicity, can offer numerous application potentials, such as hydrodynamic drag reduction, anti-biofouling, anti-corrosion, anti-fogging, anti-frosting, and anti-icing. Over the last couple of decades, we have witnessed a significant advancement in the understanding of surface superhydrophobicity as well as the design, fabrication, and applications of superhydrophobic coatings/surfaces/materials. In this talk, the designs, fabrications, and applications of superhydrophobic surfaces for multifunctionalities will be presented, including hydrodynamic friction reduction, anti-biofouling, anti-corrosion, and anti-icing.

  • PDF

Studies on the Utilization of Domestic Shale contained Chiastolite for Ceramics (국산 공정석함유 혈암의 요업적 개발에 관한 연구)

  • 정영기;오재현;이희수
    • Journal of the Korean Ceramic Society
    • /
    • v.12 no.3
    • /
    • pp.3-7
    • /
    • 1975
  • The usefulness of the domestic shale contained chiastolite as additive were investigated. Crude mixed minerals were separated into shale and chiastolite. Refractory body added simple component or multiple components as additives was obtained when firing at 125$0^{\circ}C$ for each body. Compressive strength, refractories, apparent sp. gr., water absorption, corrosion test by slag, hot linear expansion were measured and X-ray diffraction analysis was observed. As the result of study, refractory body contained separated minerals as additives showed slightly increasing in refractoriness, lowering in sintering effect, the excellent effect for corrosion resistance by acidic slag. With more containing separated minerals, hot linear expansion for the body can be decreased.

  • PDF

Evaluation of Piping Integrity in Thinned Main Feedwater Pipes

  • Park, Young-Hwan;Kang, Suk-Chull
    • Nuclear Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.67-76
    • /
    • 2000
  • Significant wall thinning due to flow accelerated corrosion(FAC)was recently reported in main feedwater pipes in 3 Korean pressurized water reactor(PWR) plants. The main feedwater pipes in one plant were repaired using overlay weld method at the outside of pipe, while those in 2 other plants were replaced with new pipes. In this study, the effect of the wall thinning in the main feedwater pipes on piping integrity was evaluated using finite element method. Especially, the effects of both the overlay weld repair and the stress concentration in notch-type thinned area on the piping integrity were investigated. The results are as follows : (1) The piping load carrying capacity may significantly decrease due to FAC. In special, the load carrying capacity of the main feedwater pipe was reduced by about 40% during about 140 months operation in Korean PWR plants. (2) By performing overlay weld repair at the outside of pipe, the piping load carrying capacity can increase and the stress concentration level in the thinned area can be reduced.

  • PDF

A Method of Residual Stress Improvement by Plastic Deformation in the Pipe Welding Zone (소성변형에 의한 배관 용접부의 잔류응력 개선 방법)

  • Choi, Sang-Hoon;Wang, Ji-Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.10
    • /
    • pp.568-572
    • /
    • 2013
  • The main components, such as a reactor vessel, in commercial nuclear power plants have been welded to pipes with dissimilar metal in which Primary Water Corrosion Cracking (PWSCC) has been occurred. PWSCC has become a worldwide issue recently. This paper addresses the results of experimental and numerical analysis to prevent PWSCC by changing the stress profile that is tensile stress to compressive stress at interesting regions with plastic deformation generated by mechanical pressure. Based on the results of experimental and numerical analysis with a 6 inch pipe and dissimilar metal welded pipes, compressive stress 68~206 Mpa is generated at all locations of inner surface in the heat affected zone.

High Strength Low Alloy Steel for Sour Service

  • Jung, Hwan Gyo;Kim, Sang Hyun;Yang, Boo Young;Kang, Ki Bong
    • Corrosion Science and Technology
    • /
    • v.7 no.5
    • /
    • pp.288-295
    • /
    • 2008
  • The increase use of natural gas as an energy source has been continuous demand for ever-increasing strength in gas transmission pipeline materials in order to achieve safe and economic transportation of natural gas. In particular, linepipe material for sour gas service primarily needs to have crack resistant property. However, applications of sour linepipes are expanding toward deep water or cold region, which require higher toughness and/or heavier wall thickness as well as higher strength. To improve the crack resistance of linepipe steel in sour environment, low alloy steel are produced by controlled rolling subsequently followed by the accelerated cooling process. This paper summarizes the design concepts for controlling crack resistant property low alloy linepipe steels for sour gas service.