• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.052 seconds

Preventive effects of water extracts from Artemisiae Iwayomogi Herba on hyperlipiderma and liver damage induced by alcohol (한인진(韓茵蔯)이 알콜 투여로 유발된 흰쥐의 고지혈증과 간 손상의 예방에 미치는 영향)

  • Seo, Bu-Il
    • The Korea Journal of Herbology
    • /
    • v.22 no.1
    • /
    • pp.103-110
    • /
    • 2007
  • Objectives : This study was performed to prove the preventive effect of water extracts from Artemisiae Iwayomogi Herba on hyperlipiderma and liver damage induced alcohol. Methods : Except for the normal group, we fed rat on 25% alcohol for 55 days. And Artemisiae Iwayomogi Herba extract was administrated for the same period. We measured the serum component in rat's blood. body weight and weight of liver. Result : At first, we observed preventive effects of Artemisiae Iwayomogi Herba on hyperlipiderma induced by alcohol. Artemisiae Iwayomogi Herba group showed significant decrease of total cholesterol and triglyceride in comparison with those of the control group. Artemisiae Iwayomogi Herba group showed significant increase of body weight in comparison with those of the control group in 4weeks and 8weeks. At second, we observed preventive effects of Artemisiae Iwayomogi Herba on liver damage induced by alcohol. Artemisiae Iwayomogi Herba group showed significant decrease of GOT, ALP and LDH in comparison with those of the control group. Artemisiae Iwayomogi Herba group showed significant increase of liver weight in comparison with those of the control group. Conclusion : Reviewing these experimental results, it appears that water extracts from Artemisiae Iwayomogi Herba have pharmaceutical preventive efficacy on hyperlipiderma and liver damage induced by alcohol. Therefore further additional study should be conducted to elucidate in depth the pharmaceutical efficacy of Artemisiae Iwayomogi Herba.

  • PDF

Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree (전자팽창밸브 개도에 따른 가변속 수냉각기의 용량제어 특성)

  • Beak, Seung-Moon;Moon, Choon-Geun;Kim, Hyun-Woo;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.282-288
    • /
    • 2010
  • The paper presents the characteristics of capacity control of variable speed water cooler with the electronic expansion valve open/close degree. It is a preliminary study on the optimum control of the water cooler system using a variable speed compressor controlled by inverter. The electronic expansion valve controlled by the variation of compressor speed maintains the constant degree of superheat at the evaporator outlet, which aims to find the degree of superheat obtaining the optimum refrigeration effect. The investigation indicates that there is a point achieving the maximum cooling capacity by the variation of the electronic expansion valve open/close degree with constant compressor speed.

Effects of Zinc Deficiency on Immune Response in Mouse (식이 아연이 Mouse의 면역 반응에 미치는 영향에 관한 연구)

  • 명춘옥
    • Journal of Nutrition and Health
    • /
    • v.21 no.2
    • /
    • pp.113-121
    • /
    • 1988
  • The purpose of this study was to investigate the effects of dietary zinc on immune response in mice. Weanling male mice was placed individually in stainless steel cages and fed a zinc dificient diet and control diet. All mice were given deionized water ad libitum. The introduction of extraneous zinc was minimized in all cage by washing feed jars and water bottles sequentially with 4mM EDTA and conc-nitiric acid followed by deionized water. After 4 and 5 weeks of the diets, mice were immunized with lx 106 Naegleria fowleri intraperitoneally. Mice were weighed once a week. The results from this study are summarized as followed ; 1) Mice fed the zinc dificient diet showed growth retardation. After 3 weeks of diets, mean body weight of zinc deficient mice was 21.4g and that of control was 25.0g. This difference is singnificant statistically (p<0.01). The more time passed, the more remarkable difference was found. 2) The weigth of organs were measured on liver, kidney, spleen, thymus, heart, lung, brain. Difference in weight were observed only in liver and spleen. 3) Proliferative response of spleen cells of zinc deficient mice to con A was lower than that of control mice after one week on immunization(p<0.005). 4) Stimulation index was lower in zinc deficient mice to phytohemagglutinin after two weeks on immunization (p<0.05). 5) Blastogenesis of speen cells of zinc deficient mice to Naegleria fowleric lysate was lower after 10 days on immunization (p<0.05). 6) Immunoglobulin G antribody titers of zinc deficient mice sera by ELISA was lowered to control mice after 5 weeks on immunization (p<0.005).

  • PDF

Effects of Pine Needle Extracts on Enzyme Activities of Serum and Liver, and Liver Morphology in Rats Fed High Fat Diet (솔잎추출물이 고지방식이를 급여한 흰쥐의 혈청, 간장의 효소 및 간조직구조에 미치는 영향)

  • 박용곤;강윤한;하태열;문광덕
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.25 no.3
    • /
    • pp.374-378
    • /
    • 1996
  • The effects of pine needle extracts on lipid contents and antioxidative enzyme activities in liver of rat were evaluated. Thirty male Sprague-Dawley rats were divided into five groups and fed high fat diets for four weeks. Each group was administered with pine needle extract in the following doses: control, water ; WE-3, hot water extract(3% PN) ; WE-6, hot water extract(6% PN) ; AE-3, acetone extract(3% PN) ; AE-6, acetone extract(6% PN). The results obtained from the experiment were as follows: GOT activities were not significantly different among experimental groups but GPT activities were significantly low in the experimental groups compared to the control group. Liver superoxide dismutase(SOD) activity of pine needle extract administered groups was higher than that of control group. Catalase activities of liver had a similar tendency to SOD activities, but were not significantly different among the groups. Liver TBARS of WE-3 WE and AE-6 groups were slightly lower than those of other groups. Microscopic observation of liver tissue revealed that pine needle extracts increased cellular swelling, which was markedly increased in WE-6 group compared with control group.

  • PDF

Automatic T-P Coagulation Control System using an EC in the MSBR Process - Full Scale Study - (MSBR 공정에서 전기전도도를 이용한 인 제거 자동제어시스템 - 현장 적용 중심 -)

  • Jang, Hee-seon;Lee, Ho-sik
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.90-96
    • /
    • 2017
  • Many sewage treatment plants have applied the advanced technology of chemical coagulant system to remove phosporus in Korea. However there are some problems for the injection of optimum coagulant dosage. In order to solve these problems, the research related to the more cost-effective automatic total phosphorus coagulation control system using an EC(Electrical Conductivity) have been in progress. This study was conducted by the same process and operation method as the Lab-scale for public small town sewage treatment plant. First, it confirmed the correlation among the EC, PO4-P and coagulant dosage in the Lab-scale MSBR(Membrane Sequencing Batch Reactor) process. Next, it analyzed that correlation coefficient of EC and the coagulant dosage was 0.92 in the Full-scale MSBR process. As a result, not only T-P removal efficiency was doubled but also it satisfied the effluent water quality standard in a stable manner. In addition, by applying the automatic control system using the EC, compared to the fixed coagulant injection system the coagulant dosage could be reduced by 28%.

Measurement and Simulation of Heating Energy for Apartments with District Heating (지역난방 아파트에 대한 난방에너지 실측 및 시뮬레이션)

  • Lee, Eun Ju;Lee, Doo Young;Hong, Hiki;Kim, Young Kyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.572-578
    • /
    • 2014
  • Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.

A Feasibility Analysis of Rapid Acquisition Test for Cement Fineness using Hydrometer (시멘트 인수검사 시 액체밀도계법에 의한 분말도 품질 신속평가 가능성 분석)

  • Han, Cheon-Goo;Kim, Young-Tae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.6
    • /
    • pp.29-34
    • /
    • 2018
  • In this research, regarding the cement supplied to ready mixed concrete plant, the feasibility of rapid acquisition test for cement fineness using hydrometer which used for early strength evaluation of concrete was analyzed. Additionally, regarding the rapid test with hydrometer control factors were provided. As a result of analysis, quality control using hydrometer was possible with the regressive equation obtained in five minute between density of suspension and fineness of cement powder. As the control factors, dispersing admixture, replacing kerosene as a medium, and temperature of cement and water were evaluated. According to the control factor evaluation, the tap water was optimum as a medium and calibration of keeping the temperature of water to $20^{\circ}C$ or correction factor was needed for density results. Finally, it is considered that the suggested rapid quality evaluation method using hydrometer is cheaper and easier method than currently used Blaine test.

Design and Implementation of an Efficient Water Count Management System (효율적인 상수도 유수율 관리 시스템 설계 및 구현)

  • Lee, Seak-Jae;Hwang, Jeong-Hee;Ha, Eun-Sil
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.169-175
    • /
    • 2010
  • The important society facility to maintain daily lives and the various activity is the water service. In this paper, we propose a design and implementation method of water count management system for the measurement, distribution and control of water quantity. The proposed system for systematic facility management and effective water service administration is a design methodology for foundation facility of water service to provide good quality water and to prevent a leak of water, estimating the water capacity.

Pitch Directional Swimming Control of Multi-Legged Biomimetic Underwater Robot (CALEB10) (다족형 생체모방 수중 로봇(CALEB10)의 Pitch 유영 제어)

  • Lee, Hansol;Lee, Jihong
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.2
    • /
    • pp.228-238
    • /
    • 2017
  • The CALEB10 is a multi-legged biomimetic underwater robot. In the last research, we developed a swimming pattern named ESPG (Extended Swimming Pattern Generator) by observing diving beetle's swimming actions and experimented with a positive buoyancy state in which CALEB10 floats on the water. In this paper, however, we have experimented with CALEB10 in a neutral buoyancy state where it is completely immersed in water for pitch motion control experiment. And we found that CALEB10 was unstably swimming in the pitch direction in the neutral buoyancy state and analyzed that the reason was due to the weight proportion of the legs. In this paper, we propose a pitch motion control method to mimic the pitch motion of diving beetles and to solve the problem of CALEB10 unstably swimming in the pitch direction. To control the pitch motion, we use the method of controlling additional joints while swimming with the ESPG. The method of obtaining propulsive force by the motion of the leg has a problem of giving propulsive force in the reverse direction when swimming in the surge direction, but this new control method has an advantage that a propulsive moment generated by a swimming action only on a target pitch value. To demonstrate validity this new control method, we designed a dynamics-based simulator environment. And the control performance to the target pitch value was verified through simulation and underwater experiments.

Development of the Automatic Control System for the Advanced Phosphorus Treatment in Sewage Treatment Plant (하수처리시설에서 인 고도처리를 위한 자동제어시스템 개발에 관한 연구)

  • Kim, Seon-Gok;Lee, Ho-Sik;Jun, Tae-Sung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.300-304
    • /
    • 2012
  • It has a limitation to satisfy the phosphorus effluent criteria of 0.2 mg/L which will be reinforced from 2012 with the Biological Nutrient Removal (BNR) process. The chemical coagulation process has been operated in parallel with the biological treatment process for advanced treatment of phosphorous in the developed countries including Europe. However, the coagulation process has some disadvantages such as the desired goal may not be achieved without injecting the optimum dosage of the coagulant. This study developed the automatic control system to inject the optimum dosage of phosphorous coagulant into the coagulation process. The adopted coagulant was 10% Poly Aluminum Chloride (PAC) in this study. The automatic control system developed in this study was adopted for the treatment of the phosphorus from the effluent in SBR process. The automatic control system was composed of the data receiving part, the optimum coagulant dosage control part and the data transmit part. The result of the phosphorous advanced treatment of the SBR effluent using the automatic control system showed the removing efficiency over 95% consistently with the phosphorous concentration under 0.02 ~ 0.15 mg/L. The reproducibility analysis for checking the safety of automatic control system showed more than 95% correlation.