• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.046 seconds

Development of a Garlic Peeling System Using High-Pressure Water Jets (III) - Introduction of a microbial control system - (습식 마늘박피 시스템 개발 (III) - 미생물 제어 시스템의 도입 -)

  • Kim J.;Bae Y. H.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.17-24
    • /
    • 2005
  • An efficient microbial control system was introduced into a garlic peeling system using pressurized water in order to improve the quality and the shelf-life of peeled garlic. High microbial density of the spoiled peeled garlic and the water used for peeling and washing indicated that an efficient microbial control system is necessary far the peeling system. Though Pseudomonas spp. and Penicillium spp. were closely related to the spoilage of peeled garlic, the spoilage of peeled garlic was thought to be caused mainly by nonspecific increase in microbial density. The shelf-life of the garlic peeled by pressurized water was longer than that of the garlic peeled by pressurized air, and the degree of damage had great effect on the shelf-life of peeled garlic. Ozonated water was effective in decreasing the microbial contamination and in increasing the shelf-life of peeled garlic. Based on the findings of the study, following improvements were made to the garlic peeling system using pressurized water; 1) the water circulation system was modified in order to completely separate the water for washing from the water for garlic peeling, 2) filtration and cooling equipments were introduced into the circulation system of the water for peeling, and 3) an ozone generator which could continuously supply ozonated water (dissolved ozone concentration of 0.4 ppm) was attached to the circulation system of the water for washing.

Research of Sludge Quantity and Evaluation of Sludge Handling Facilities in Water Treatment Plants (정수 슬러지 발생량 조사 및 슬러지 처리시설의 공정평가)

  • Moon, Seong-Yong;Kim, Seung-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.279-290
    • /
    • 2004
  • Sludge quantity has increased at "A"water treatment plant due to deterioration of raw water quality and GAC installation. Increased sludge resulted in overloading on sludge handling facilities. The object of this study is to survey sludge quantity and capacity of sludge handling facilities at "A"water treatment plant. Measured quantity of sedimentation sludge considerably exceeded the design capacity of sludge holding basin. Sludge holding basin was properly designed, but low concentration of sludge discharged from sedimentation basin caused production of large volume of the sludge. Timer operated control system for sludge withdrawal unit and leakage through a control valve were suspected to cause the low concentration. Augmentation of the control system by a turbidity meter and addition of a new control valve successfully reduced the sludge volume enough to satisfy the design capacity of sludge holding basin. Unlike sedimentation sludge, measured quantity of washwater was considerably less than the design capacity of washwater basin because it was over-designed.

The Analysis of Harmonics at a Inverter System of Low Voltage and the Methods for the Reduction (저압 인버터 시스템의 고조파 분석 및 저감 방안 연구)

  • Shin, Gang-Wook;Hong, Sung-Taek;Lee, Dong-Keun;Lee, Eun-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.64-66
    • /
    • 2005
  • Recently, Many water treatment facilities are operated by automatic control or by remote control. These high technology control systems require more stable power supply than before. Badly most automatic control systems adopted in water treatment facilities are non-linear load which generates electrical harmonics inevitably. This study is intended to measure and analyze the electrical harmonics occurred at the chemicals control device which is inverter application circuit, and to show the Method for reduction.

  • PDF

Controlling Spillway Gates of Dams Using Dynamic Fuzzy Control

  • Woo, Young-Woon;Han, Soo-Whan;Kim, Kwang-Baek
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.337-342
    • /
    • 2008
  • Controlling spillway gates of dams is a complex, nonlinear, non-stationary control process and is significantly affected by hydrological conditions which are not predictable beforehand. In this paper, control methods based on dynamic fuzzy control are proposed for the operation of spillway gates of dams during floods. The proposed methods are not only suitable for controlling spillway gates but also able to maintain target water level in order to prepare a draught. In the proposed methods, we use dynamic fuzzy control that the membership functions can be varied by changing environment conditions for keeping up the target water level, instead of conventional static fuzzy control. Simulation results demonstrate that the proposed methods based on dynamic fuzzy control produce an accurate and efficient solution for both of controlling spillway gates and maintaining target water level defined beforehand.

A Study on Operation Control Technology Required for Introduction of Intelligent Sewage Treatment Plant (스마트 하수처리장 도입에 필요한 운전제어기술에 관한 연구)

  • Lee, Jiwon;Kim, Yuhyeon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • Smart sewage treatment plant means creating a safe and clean water environment by establishing an ICT-based real-time monitoring, remote control management and intelligent system for the entire sewage treatment process. The core technology of such a smart sewage treatment plant can be operation control technology using measuring instruments. This research team analyzed and suggested the operation control technologies necessary for the establishment of the intelligent business by referring to the intelligent research projects of the sewage treatment plant in progress in Korea. As a result of the analysis, a total of six removal technologies were presented, including control by scale, reflow water control, linked treated water control, chemical quantity control, winter operation control, and total organic carbon control. By size, standards that can be classified into small and medium-sized large-scale are presented, and in the case of reflow water control, the location of water quality and flow sensors capable of managing reflow water is suggested. In the case of the linked treated water control, the influence and control points of the linked treated water on the sewage treatment plant were presented, and in the case of the chemical injection volume control, a system capable of optimizing the amount of chemical injection according to the introduction of an intelligent sewage treatment plant was presented. In the case of winter operation, the sensors and pumps to be controlled are suggested when considering the decrease in nitrification due to the decrease in water temperature. In the case of total organic carbon control, an interlocking system considering the total amount of pollution in the future was proposed. These operation control scenarios are expected to be used as basic data to be used in intelligent sewage treatment algorithms and scenarios in the future.

A Controller Development of Water Heating in a Ceramic Pipe Using Electronics Control System (전자제어 장치를 이용한 세라믹 파이프의 온수제어기 개발)

  • Lee, Jung-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.717-722
    • /
    • 2011
  • This paper presents that the electronic controller is developed for controlling the setting temperature and water in the ceramic pipe system. The heating water system is designed for controlling the temperature to supply the heat through the ceramic pipe heater to input the water, also for controlling quantity of water using the water sensor and impeller. The control method of the heating water system is applied the mathematic modeling of the ceramic pipe heater on the suppling the heat at coming water, and the test result of the electronic controller is present to smartly control the setting temperature, therefore the ceramic pipe heater is proposed to be able to apply the heating structure and the control methods as a product.

The Effects of Alcohol-Steamed Rhei Rhizoma and Row Rhei Rhizoma on varied Extraction Time in Blood Stasis Model (전탕시간(煎湯時間)에 따른 생대황(生大黃) 및 주대황(酒大黃)이 어혈병태모형(瘀血病態模型)에 미치는 영향(影響))

  • Kim, Do-Wan;Park, Chang-Gook
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.114-133
    • /
    • 1998
  • In order to investigate the effects of Alcohol-Steamed Rhei Rhizoma and Row Rhei Rhizoma on varied extract time in both endotoxin-induced blood stasis model(hereafter Endotoxin Model) and hydrocortisone acetate-induced blood stasis model (hereafter HA Model), Half of rats were treated with endotoxin(0.4mg/kg, single Ⅳ, into caudal vein) for Endotoxin Model. Thereafter, they were orally administrated water extract of Alcohol-Steamed Rhei Rhizoma or Row Rhei Rhizoma, which were boiled during 30, 60, 120 minute, respectively. Finally, the number of platelet, fibrinogen, prothrombin time, hematocrit, the number of RBC and WBC were measured after sacrifice. The remainder rats were treated with hydrocortisone acetate(10mg/kg, daily IM for 7 days into the muscular rump) for HA significantly decreased. Together, they were orally administrated for 7 days water extract of Alcohol-Steamed Rhei Rhizoma or Row Rhei Rhizoma that were boiled above methods Finally, the number of platelet, fibrinogen, prothrombin time, hematocrit, the number of RBC and WBC were measured after sacrifice. The results were summarized as follows : 1. The number of platelet was significantly increased in boiled water extract for 30 min of Row Rhei Rhizoma group as compared with that of control group in Endotoxin Model. 2. Fibrinogen level was significantly increased in all administration groups as compared with that of control group in Endotoxin Model. It was significantly increased in all administration groups except boiled water extract for 30 min of Alcohol-Steamed Rhei Rhizoma group as compared with that of control group in HA Model. 3. Prothrombin time was significantly shortened in boiled water extract for 60 min of Alcohol-Steamed Rhei Rhizoma group and boiled water extract for 120 min of Alcohol-Steamed Rhei Rhizoma group as compared with that of control group in Endotoxin Model It was significantly shortened all administration groups as compared with that of control group in HA Model. 4 Hematocrit was significantly increased in all administered groups except boiled water extract for 60 min of Alcohol-Steamed Rhei Rhizoma group and boiled water extract for 30 min of Row Rhei Rhizoma group as compared with that of control group in Endotoxin Model. It was significantly increased in all administration groups as compared with that of control group in HA Model. 5. The number of RBC was significantly decreased in boiled water extract for 60 min of Alcohol-Steamed Rhei Rhizoma group, boiled water extract for 120 min of Alcohol -Steamed Rhei Rhizoma group and boiled water extract for 30 min of Row Rhei Rhizoma administered group in Endotoxin Model. It was significantly increased boiled water extract for 30 min of Row Rhei Rhizoma group and boiled water extract for 60 min of Row Rhei Rhizoma group in HA Model as compared with data of control group. 6 The number of WBC was significantly decreased in all administered groups except boiled water extract for 30 min of Alcohol-Steamed Rhei Rhizoma group and boiled water extract for 60 min of Alcohol-Steamed Rhei Rhizoma group as compared with that of control group in HA Model.

  • PDF

Remote Control System of the Uninhabited Small Water Booster Supply (소규모 무인급수 가압장 원격제어시스템)

  • Lee, Kyong;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1997-1998
    • /
    • 2006
  • In this paper, we propose a remote control system which is used by internet network system in the small water booster supply. So far, TMTC(Tele Metering Tele Control) has been used to control and monitor small water booster pump. But it is possible and easy to control and observe local booster panel with the rapid development of internet, This new system is to provide operators and managers with sufficient information and control in order to implement the operation in an efficient and economical way. This system consists of three parts that are controller, netpump server and netview client. Controller has a dual architecture. The motive for installing controller is the continuous production and supply of drinking water.

  • PDF

The construction of a PLC simulator for level control (유량 제어을 위한 PLC 시뮬레이터 구성)

  • Lee, Gi-Bum;Yoon, Woo-Sik;Jeong, Hee-Don;Lee, Jin-S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2605-2607
    • /
    • 2000
  • This paper represents the construction of a PLC simulator for the level control of water and the speed control of the water cask. The level and speed processes are automatically operated by the PLC. The simulator system consists of PLC, program loader and control penal. The digital input and output units make the valves of the water cask the On or Off state. The analog input and output units control the level of water and the speed of the water cask. A LD program is used in the control language of PLC.

  • PDF

A Study of the Technical Treatment within an Environmental Appetency for the Ballast Water

  • Nam, Chung-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1313-1323
    • /
    • 2004
  • In accordance with adoption of new convention for the control of ship's ballast water at the diplomatic conference held in London Feb, 2004, every country has to regulate the ballast water and deposit matters. When this Resolution comes into effect in 2009, all vessels engaged in international voyage must have ballast water control program, ballast water records, equipments which are suitable to the standard of exchange and performance for the ballast water. This study estimates objectively their performances, merits and demerits of the ballast water treatment technique and exchanging techniques for safe operation of ships. It is desirable to design an equipment to control the ballast water using the brush-type vacuum suction nonstop reverse cleaning system to overcome the clogging phenomenon and the direct disc filtering to maximize filtering area for the optimum process considering biological availabilities. It will be expected to protect against marine pollution and to maintain clean sea if it is secured to develop new ballast water treatment techniques. And it will also be expected to cope with the Resolution and each regulation of the developed countries from the ballast water.