• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.046 seconds

Experimental Study on the Accumulation of Cadmium and Other Metals in the Fish Bodies(Oryzias latipes) (송사리(Oryzias latipes)의 생체내 카드뮴 및 미량금속의 축적에 관한 실험적 연구)

  • 조영채;송인순;박상환
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.25-31
    • /
    • 2000
  • In order to assess the accumulation levels of cadmium and other metals(Zn, Cu, Ca and Fe) in fish bodies, an experimental study was performed by raising fry of "Oryzias latipes" in the water containing cadmium 0.03 ppm, cadmium 0.03 ppm + zinc 0.03 ppm and in the tap water(control group) were made. In the results the concentration of Cd in fish bodies were increased with advancing exposure time in Cd 0.03 ppm treated group and 0.03 ppm + Zn 0.03 ppm treated group, but there was no significantly different between both groups with Cd concentration in each week. The concentration of Zn in fish bodies was no changed with advancing exposure time in control group and Cd 0.03 ppm + Zn 0.03 ppm treated group were significantly different from control and Cd 0.03 ppm treated group. The concentration of Cu, Ca and Fe in fish bodies were increased with advancing exposure time, and control group was higher than any other groups. Simple correlation analysis showed that the positive correlation between Cd and Zn, Cu and Ca, Fe, Ca and Fe, but Cd was negative correlation with Cu, Ca and Fe. In conclusion, we investigated a tendency that the concentration of Cd and Zn in fish bodies tended to increase with the lapse of time, but Cu was unchanged and those of Ca and Fe were decreased in administrating the trace dose of Cd and Zn in water. in water.

  • PDF

Effect of Soy Isoflavone Intake on Water Maze Performance and Brain Acetylcholinesterase Activity in Rats (대두 이소플라본 섭취가 흰쥐에서 미로수행능력과 뇌 중 Acetylcholinesterase 활성에 미치는 영향)

  • Oh Hyun-Kyung;Kim Sun-Hee
    • Journal of Nutrition and Health
    • /
    • v.39 no.3
    • /
    • pp.219-224
    • /
    • 2006
  • This study was performed to determine the effect of soy isoflavones on brain development and function in rats. Forty Sprague-Dawley male rats were provided diets containing different levels of soy isoflavones for 6 weeks; 0 ppm (control), 50 ppm (low isoflavone intake; LI), 250 ppm (medium isoflavone intake; MI) and 500 ppm (high isoflavone intake; HI). Learning ability was evaluated by a Y-shaped water maze and the activity of acetylcholinesterase in brain was assayed after decapitation. Food intake and body weights as well as weights of brain, liver, spleen, heart and kidney showed no significant difference among the four groups, which means 500 ppm of isoflavones is safe. In the water maze test, the frequency of error counted when rats entered one end of the alley without platform was significantly lower in the HI group than in the control group, and the escape latency as swim time taken to escape on the hidden platform was significantly shorter in the HI group than in the LI and control groups. The activity of acetylcholinesterase of the brain was significantly higher in the HI and MI groups than in the control group. Therefore, the results indicate that isoflavones may improve the cognitive function without adverse effects.

A Study of Disinfection Process Automation through Control Logic Program Development (제어로직 프로그램 개발을 통한 소독공정 자동운전에 관한 연구)

  • Park, Jong-Duk;Shin, Gang-Wook;Hong, Sung-Taek;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3644-3653
    • /
    • 2011
  • This study proposes the automation of disinfection process in water treat plant to reach target effluent chlorine concentration rate according to chlorine consumption rate by varying travel time. Hydraulic analysis about the process and local facility was surveyed first and the program for automatic operation was developed to solve current problem, whose applied result was presented and proved to be better than present controller. Especially using multi variable process algorithm, the correlation coefficient is analyzed between environment factor and reaction time, and process control prove to be stable through model estimation with optimal control input.

Development of Nutrient Solution Control System for Water Culture (수경재배(水耕栽培)의 양액관리(養液管理) 자동화(自動化) 시스템 개발(開發))

  • Lee, K.M.;Lee, J.S.;Sun, C.H.;Jang, I.J.;Song, J.G.;Koo, G.H.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.4
    • /
    • pp.328-338
    • /
    • 1990
  • The objective of this study was to develop automatic systems of nutrient solution management for optimal nutrient solution environment and labor saving in water culture which enables factory crop production. In this study, an automatic control system and its driving program are developed to prepare, supply, and recover nutrient solution and to keep the optimal solution concentration level using microcomputers. Based on this study, the following conclusions are obtained: 1. The concentration measured by the system using oscillating circuit designed and built in this study, gave good agreements with the actual nutrient solution. 2. In water culture, the period of 12 hours for measuring concentration, pH, and temperature of the nutrient solution was optimum. Addition of control solution due to the decrease of the nutrient solution concentration is required in every 3 to 5 days. 3. It is estimated that the period of the whole solution change is 15 days, however, further research is needed to assure it. In addition, this period must be shortened in the future. 4. Both the hardware and software of the developed optimal nutrient solution control system in the water culture are working very well, however, it is necessary to develop a more economical one-chip micro controller to substitute for the microcomputer.

  • PDF

Membrane fouling control in low pressure membranes: A review on pretreatment techniques for fouling abatement

  • Arhin, Samuel Gyebi;Banadda, Noble;Komakech, Allan John;Kabenge, Isa;Wanyama, Joshua
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.109-120
    • /
    • 2016
  • Conventional treatment techniques cannot meet the stringent modern water quality regulations emanating from the need to provide high quality drinking water. Therefore, a number of studies have suggested low pressure membrane filtration as a worthwhile alternative. However, a major constraint to the extensive use of this technology in low and middle income countries is the high operating and maintenance costs caused by the inherent predisposition to membrane fouling. Notwithstanding, pretreatment of feed water using techniques such as coagulation, adsorption, oxidation and bio-filtration is believed to control fouling. In this review paper, the existing scientific knowledge on membrane fouling and pretreatment techniques for controlling fouling in low pressure membranes is analyzed with the aim of providing new and valuable insights into such techniques, as well as unveiling crucial issues noteworthy for further studies. Among the techniques reviewed, coagulation was observed to be the most cost-effective and will remain the most dominant in the coming years. Although oxidants and magnetic ion exchange resins can also control fouling, the propensity of oxidants to form health treating precursors and the high economic implications of magnetic ion exchange resins will hinder their adoption in developing countries.

Prediction Models to Control Pro-chlorination in Water Treatment Plant (정수장 후염소 공정제어를 위한 예측모델 개발)

  • Shin, Gang-Wook;Lee, Kyung-Hyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.213-218
    • /
    • 2008
  • Prediction models for post-chlorination require complicated information of reaction time, chlorine dosage considering flow rate as well as environmental conditions such as turbidity, temperature and pH. In order to operate post-chlorination process effectively, the correlations between inlet and outlet of clear well were investigated to develop prediction models of chlorine dosages in post-chlorination process. Correlations of environmental conditions including turbidity and chlorine dosage were investigated to predict residual chlorine at the outlet of clear well. A linear regression model and autoregressive model were developed to apply for the post-chlorination which take place time delay due to detention in clear well tank. The results from autoregressive model show the correlationship of 0.915~0.995. Consequently, the autoregressive model developed in this study would be applicable for real time control for post chlorination process. As a result, the autoregressive model for post chlorination which take place time delay and have multi parameters to control system would contribute to water treatment automation system by applying the process control algorithm.

Simulation of a piezoelectric flextentional deep-water sonar transducer using a coupled FE-BEM (결합형 유한요소-경계요소 기법을 사용한 심해저용 압전형 유연성 쏘나 변환기의 시뮬레이션)

  • Jarng Soon Suck;Lee Je Hyeong;Ahn Heung Gu;Choi Heun Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.218-223
    • /
    • 1999
  • A piezoelectric flextentional deep-water sonar transducer has been simulated using a coupled FE-BEM. The dynamics of the sonar transducer is modelled in three dimensions and is analyzed with extern리 electrical excitation conditions as well as external acoustic pressure loading conditions. Different results are available such as steady-state frequency response for RX and TX, displacement modes, directivity patterns, back-scattering patterns, resonant frequencies, bandwidths, quality factors, transmitting voltage (TV) responses, input receiving sensitivity (RS) responses. White the present barrel-stave typed sonar transducer of the piezoelectric material is being simulated, the external surface of the transducer is modified in order to allow the same water pressure to be applied to the inner and the outer surfaces of the transducer. With this modification for deep-water application, the resonance frequency of the modified flextentional sonar transducer becomes much lower than that of the unmodified flextentional sonar transducer. The results of the present sonar transducer modelling are also compared with those of a commercial package such as ATILA.

  • PDF

A Study on the Performance Improvement of a Simultaneous Heating and Cooling Water Source Heat Pump System by Controlling of the Refrigerant Flow Rate in an Outdoor Unit (수열원 냉난방 동시형 히트펌프 시스템의 실외 열교환기 유량제어를 통한 성능개선에 관한 연구)

  • Bae, Heung Hee;Lee, Dong Hyuk;Lee, Sanghun;Kim, Byengsoon;Ahn, Young Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.131-136
    • /
    • 2013
  • The present study has conducted cycle design and control technology of a water source VRF heat pump system. Previously, study of a simultaneous heating and cooling in an air source VRF heat pump system has been conducted. However, performance data and design methods for simultaneous heating and cooling in a water source VRF heat pump system are limited in the literature, due to various system parameters and operating conditions. In this study, the operating characteristics and performances of a simultaneous heating and cooling heat pump system are carried out, in simultaneous operation modes. Control logics of an EEV are developed for flow rate control to the outdoor unit, and are verified. When the control logics are applied, the simultaneous cooling and heating performances are sufficiently achieved, and system COPs are increased by up to 23.4%.

Optimal Operation Control for Energy Saving in Water Reuse Pumping System (에너지절감을 위한 물 재이용 펌프시스템의 최적운전 제어)

  • Boo, Chang-Jin;Kim, Ho-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2414-2419
    • /
    • 2012
  • This paper presents an optimal operation control method for energy saving in the water reuse pumping system. A predictive horizon switching strategy is proposed to implement an optimal operation control and a linear programming (LP) algorithm is used to solve optimal problems in each time step. Energy costs are calculated for electricity on both TOU in the light, heavy, and maximum load time period and peak charges. The optimal operation in water reuse pumping systems is determined to reduce the TOU and peak costs. The simulation results show a power energy saving for water reuse pumping systems and power stability improvement.

The Effects of Cold Water Gargling on Thirst, Oral Cavity Condition, and Sore Throat in Orthopedics Surgery Patients (냉수 가글링이 정형외과 수술환자의 갈증, 구강상태, 인후통에 미치는 효과)

  • Yoon, Seo-Young;Min, Hye-Sook
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.14 no.2
    • /
    • pp.136-144
    • /
    • 2011
  • Purpose: A purpose of this study was to identify the effects of cold water gargling on thirst, oral cavity condition and sore throat in orthopedics surgery patients who underwent general anesthesia. Methods: Pretest-posttest non-synchronized design with a nonequivalent control group was used. A total of 52 participants were conveniently selected and assigned to each group. The experimental group gargled hourly with cold water for 8 hours after operation. The control group received wet gauze as needed. We compared the thirst, oral cavity condition and sore throat at 0, 2, 4 and 8 hours after operation. Results: The score of thirst and oral cavity condition was lower in the experimental group than in the control group. However, there was no significant differences in the levels of sore throat between the experimental and control group. Conclusion: These findings suggest that cold water gargling can be a useful nursing intervention for alleviating thirst and improving oral condition for patients with orthopedic surgery after general anesthesia.