• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.044 seconds

The Study on the Generation Integrated Operating System(GIOS) in KOWACO (발전 통합 운영 시스템에 관한 연구)

  • Kim, Hyung-Yun;Kim, Ki-Won
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2254-2256
    • /
    • 2004
  • Korea Water Resources Corporation (KOWACO), the only organization specialized in water resources management in Korea, is planning to establish a centralized control system for a related operation. in the central control room, of decision making as to water management and electric power generation. This plan is intended to convert the existing on-site operation system in each multi-purpose dam across the nation into a central operation system in the Corporations head office, for which Generation Integrated Operating System (GIOS) will be established control center in the Corporations head office and modernized nine (9) power stations. substations (RDAC). This article discusses realization of GTOS, especially real-time operation of hydropower plants and a specific architectural features for system communication.

  • PDF

The Effects of Waste Leachate on the Eco-Physiological Characteristics of Populus euramericana

  • Woo, Su-Young
    • The Korean Journal of Ecology
    • /
    • v.22 no.6
    • /
    • pp.343-348
    • /
    • 1999
  • Populus euramericana has been identified as a possible species for use for phytoremediation of landfills. To identify the effects of waste leachate on the growth and physiological characteristics of Populus euramericana. four different treatments were applied to Populus euramericana seedlings: leachate solution (100% leachate). 25% dilution (75% leachate: 25% water. v/v), 50% dilution (50% leachate: 50% water. v/v) and control (100% tab water) were applied to Populus euramericana. Treatment with waste leachate significantly stimulated Populus euramericana height. diameter at root collar and biomass production relative to the water control. Chlorophyll contents. photosynthesis and transpiration of leachate irrigated-trees were significantly higher than those of water control. These results suggested that poplar could be a suitable species for phytoremediation in landfills because these species showed good growth performance and were capable of taking up waste leachate.

  • PDF

Domestic Legislation for Acceptance of 'International Convention for the Control and Management of Ship's Ballast Water and Sediments' (밸러스트수 국제협약 수용을 위한 입법화 방안)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.2 s.23
    • /
    • pp.83-96
    • /
    • 2005
  • As recently, 'International convention for the control and management of ship's ballast water and sediments' was adopted, it is necessary to accept the international convention in Korea The movements of foreign countries for ship's ballast water control and management were investigated, and domestic environment-related laws were reviewed and compared regarding the discharge of industrial wastewater and ship's ballast water. Alternative measures of domestic legislation were suggested for acceptance of the international convention.

  • PDF

A Remote Control System Design For a Desalination Plant (도서지역 해수담수화설비 원격감시제어시스템 구성)

  • Jeong, Han-Sang;Lee, Heung-Ho;Park, Soon-Mo;Chang, Jeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1699-1700
    • /
    • 2008
  • The dissertation is based on the 'remote monitoring control system' for a water desalination plant which changes seawater into safe clean drinkable water. The system is operated and supported by a satellite link which can be easily handled and monitored by any professional. Therefore the system can be operated from any given location. The design allows it to function on islands that have frequent and severe water shortages via the satellite from the main sector. It shows the specific details for the main provision on building the remote monitoring control system for the water desalination.

  • PDF

Performance Research of a Jacket Cooling Water System in a Diesel Electric Generation (디젤발전 자켓냉각시스템 열성능 향상 연구)

  • Lee, Jae-Keun;Moon, Jeon-Soo;Yoon, Seok-Won;Park, Pill-Yang
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.6
    • /
    • pp.534-539
    • /
    • 2009
  • One of the most efficient techniques improving the heat transfer performance of a diesel electric generation is a corrosion control in jacket cooling water system. The environmental parameters most affecting corrosion are dissolved salt concentration, temperature, and pH of cooling water. No corrosion occurs in carbon steel probe at pH 11 in normal operating condition of diesel electric generation cooling water. pH control agent in this study is trisodium phosphate. pH control appears to be the most convenient way to enhance the thermal performance of a diesel electric generation.

The Systematic Evaluation of the SCADA System Proposals for Multi-purpose Dam and Water Supply Office (댐 및 수도 사무소 감시제어시스템의 체계적 기술평가 방안)

  • Paik, D.H.;Lee, E.W.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.217-219
    • /
    • 1998
  • Korea Water Resources Corporation (KOWACO) annually supplies about 2 billion Kwh and 7.3 billion $m^3$ with its 10 multi purpose dams and 20 water supply offices. For the proper control and management of the above utilities, sequential control equipment and SCADA/DCS have been operated and maintained. In this paper, 8 control system evaluations for hydropower dam, water supply, electric power and subway projects during 1984-1997 were reviewed and analyzed. The systematic evaluation method has been established in the points of the purpose, method, procedure, evaluation team, evaluation criteria, total evaluation table and the contents of final recommendation report. With keeping in mind the essential points, it is expected for the more effective and fair evaluation of bids.

  • PDF

An automated control system for concrete temperature development in construction

  • Qiang, Sheng;Leng, Xue-jun;Wang, Xiang-rong;Zhang, Jing-tao;Hua, Xia
    • Computers and Concrete
    • /
    • v.24 no.5
    • /
    • pp.437-444
    • /
    • 2019
  • PLC and its expansion module, electric ball valve and cooling pipe, electric heating steel plate and various components of the system, which is used to control test and process data. By automatically adjusting the opening of the valve, the system makes the top temperature and cooling speed develop along the ideal temperature diachronic curve. Moreover, the system enables the temperature difference between inside and surface of test block limited in a given range by automatically controlling the surface board heating. The method of physical simulation test by sandbox with built-in cooling water pipe and heating rod is adopted. On the premise of a given standard value, the operation of the system is checked under different working conditions. Further, an extension of this system is proposed, which enables its application to obtain some thermal parameters when cooperating with numerical simulation.

A Study on the Noise Reduction and Performance Improvement of the Hot Water Distributing System (시스템분배기 소음방지 및 성능개선방안 연구)

  • Kim, Yong-Ki;Lee, Tae-Won;Han, Tae-Su;Yoo, Sun-Hak
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1055-1060
    • /
    • 2009
  • Noise is one of the major environmental problems in human life. But hot water distributers with the flow rate control valve bring about often noise according to the heating control condition in residential buildings. The sound power level increased as the flow rate and pressure difference increased. And thus, experimental analyses for the flow rate control and the pressure difference control were carried out in this study to reduce the noise emitted from the flow rate control valve. As the results, the flow rate control method using a SMA(Shape Memory Alloy)-valve and the flow rate control system using a pressure difference sensor can be expected to control noise in the region of below 50 dB of sound power level.

  • PDF

A Study on the Water Quality Management in Fallow Paddy Fields (휴경논에서의 수질관리 연구)

  • Kim Hyung-Jong;Kim Sun-Joo;Kim Phil-Shik;An Yeul;Yang Yong-Suck
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.2
    • /
    • pp.69-76
    • /
    • 2006
  • Fallow paddy areas have been increased due to the import of cheap agricultural product, and the unbalance between farming cost and rice price since 1990. The increasing fallow paddy area needs to be protected from the devastation by weed breeding for the re-cultivation. In this study, two fallow paddy fields managed with different water depth were selected for monitoring and analysing of water quality, water balance and plant body change. The managed fallow paddy fields were more effective in water quality purification and plants growth control than non-managed fallow paddy fields. And the fallow paddy field managed with some degree of water depth was the most effective field in terms of weed control.

Walk-by Meter Reading System of Digital Water Meter Based on Ubiquitous (유비쿼터스기반 디지털 수도미터 옥외검침시스템 개발)

  • Shin, Gang-Wook;Hong, Sung-Taek;Lee, Young-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.7
    • /
    • pp.688-693
    • /
    • 2009
  • In terms of water meter reading, the majority of 16 million houses use mechanical water meter in korea. So, a member of the utility's staff needs to access periodically the water meter and the value of the metered volume. However, due to the use of mechanical water meter, many issues have been appeared as cost, time, errors, accessibility, and readability. To settle these issues, we developed the walk-by meter reading system of digital water meter and outside indicator based on ubiquitous. And we could get the characteristics and the economical efficiency for water meter reading system. Thus, this study shows that the system can be widely used to the block system and the meter reading system for stable water supply.