• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.041 seconds

Design Methods and Capacity Analysis of Artificial Circulation Systems in Korean Reservoirs (우리 나라 저수지의 수중 폭기 장치의 설계 방법 및 용량 분석)

  • Seo, Dong-Il;Seog, Kwan-Soo;Lee, Byung-Doo;Jeong, Sang-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.366-376
    • /
    • 2004
  • Use of artificial circulation system has become popular in Korean reservoirs to control algal blooms and subsequent color, taste and odor problems in drinking water. It was found that the most of aeration system in Korean reservoirs are under-designed compared to existing installations in US and Australia. This was especially true for larger reservoirs greater than $5{\times}10^7m^3$ in volume since it is common to install the system in the vicinity of intake areas only. Consequently, successful cases of artificial circulation systems operations are limited to few small reservoirs less than $1{\times}10^7m^3$. It is suggested that the design methods need to be developed considering physical characteristics and water quality kinetics inside of reservoirs. Also operation methods of artificial circulation systems need to be established considering the water quality dynamics, stratification and morphological characteristics of reservoirs. Finally, it is suggested to maintain comprehensive and long term monitoring programs to validate the application of artificial circulation system in reservoirs.

Evaluation of Water Quality in the Keum River using Statistics Analysis (통계분석 기법을 이용한 錦江水系의 水質評價)

  • Kim, Jong-Gu
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1281-1289
    • /
    • 2002
  • This study was conducted to evaluate water quality in the Keum River using multivariate analysis. The analysis data in Keum river made use of surveyed data by the ministry of environment from January 1994 to December 2001. Thirteen water quality parameter were determined on each sample. The results was summarized as follow; Water quality in the Keum River could be explained up to 71.39% by four factors which were included in loading of organic matter and nutrients by the tributaries (32.88%), seasonal variation (16.09%), loading of pathogenic bacteria by domestic sewage of Gapcheon (13.39%) and internal metabolism in estuary as lakes(9.03%). For spatial variation of factor score, four group was classified by each factor characterization. Station 1 and 2 was influenced by Daechung dam, station 3 was affected by domestic sewage of Gapcheon, station 10~12 was affected by estuary dyke and the rest station. The result of cluster analysis by station was classified into four group that has different water quality characteristics. In monthly cluster analysis, three group was classified according to seasonal characteristic. Also, in yearly cluster analysis, three group was classified. It is necessary to control the pollutant loadings by Gapcheon inflow domestic sewage in Daejeon city for the sake of water quality management of Keum river.

Reduction Techniques of the Pipe Line net Using According to DVGW (DVGW이론에 따른 상수관망의 부식방지를 위한 정수처리방안)

  • Choo Tai-Ho;Kim Ha-Il
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.115-118
    • /
    • 2005
  • Leakage of waterworks pipe line net cause loss of water resources, additional foundation of pressurization facilities from pressure loss and soil weakening near leaked pipe line, etc. This is difficult to maintain and manage waterworks pipe line net and to cause serious economic loss. Rate of accounted water is better by monitoring always water pressure and flux, etc. from isolated region, positively dealing with leakage accident and preventing leakage from occurring. Actually after isolating region, average rate of accounted water in this region is 88.94% by continuously monitering control of water pressure and inflow rate. It is about 9.44% more than that of Busan metropolitan city in 2003, 79.5%.

  • PDF

Floristic Composition and Phytomass in the Drawdown Zone of the Soyangho Reservoir, Korea

  • Cho, Hyunsuk;Jin, Seung-Nam;Marrs, Rob H.;Cho, Kang-Hyun
    • Ecology and Resilient Infrastructure
    • /
    • v.5 no.2
    • /
    • pp.94-104
    • /
    • 2018
  • The Soyangho Reservoir in Korea has a large drawdown zone, with an annual maximum water level fluctuation of 37 m due to dam operations to maintain a stable water supply and control flooding, especially during the monsoon period. The floristic composition, distribution and biomass of the major plant communities in the drawdown zone of the Soyangho Reservoir were assessed in order to understand their responses to the wide water level fluctuation. Species richness of vascular plants was low, and species composition was dominated by herbaceous annuals. Principal coordinates analysis using both flora and environmental data identified slope angle and the distance from the dam as important factors determining floristic composition. The species richness was low in the steep drawdown zone close to the dam, where much of the soil surface was almost devoid of vegetation. In shallower slopes, distant from the dam plant communities composed of mainly annuals were found. The large fluctuation in water level exposed soil where these annuals could establish. An overall biomass of 122 t (metric tons) Dry Matter was estimated for the reservoir, containing ca 3.6 t N (nitrogen) and ca 0.3 t P (phosphorus); the role of the vegetation of the drawdown zone in carbon sequestration and water pollution were briefly discussed.

Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions (정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.

A Study on the Determination Method of TOC Effluent Limitation for Public Sewage Treatment Plants (하수처리시설의 방류수 수질기준 설정방법 고찰 - TOC를 중심으로 -)

  • Jeong, Dong-Hwan;Cho, Yangseok;Ahn, Kyunghee;Chung, Hyen-Mi;Park, Hoowon;Shin, Hyunsang;Hur, Jin;Han, Daeho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.241-251
    • /
    • 2016
  • As the Enforcement Ordinance of Environmental Policy Act was revised in 2013, total organic carbon(TOC) was added as an indicative parameter for organic matter in Water and Aquatic Ecosystem Environmental Criteria. Under these imminent circumstances, a regulatory standard is needed to achieve the proposed TOC limitation control water quality from the public sewage treatment plants(PSTWs). This study purposes to present the determination method for TOC effluent limitation at the PSTWs. Therefore we investigate the TOC effluent limitation of foreign countries such as EU, Germany and USA, and analyse the effluent water qualities of PSTWs. In using these TOC data, we review apprehensively the statistics-based, the technology-based, and the region(water quality)-based determination method of TOC effluent limitation for PSTWs.

A Study on the Potable Water Purification System with Pre-Ozone and Ultra Filtration Membrane of Hollow Fiber Type (전오존과 중공사형 한외여과막을 이용한 간이정수처리시스템에 관한 연구)

  • Kim, Min-Kuk;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.196-204
    • /
    • 2005
  • The objective of this study is to evaluate the possibility to apply pre-ozone and membrane system for drinking water. This system is improved in fouling control by pre-ozone system. It is composed of ultrafiltration hollow fiber type membrane and ozone reactor. The result of this study is that the flux is increased about 10.7% and decreased in TMP by the pre-ozone. Also, backwashing pressure decreased about 18%. The optimum concentration of residual ozone is 0.3~0.5 ppm. During the period, the recovery ratio of this system was turned out to be 90% as the flowrate of effluent is $67.1m^3/day$. When the TMP and backwashing pressure was $0.85kg/cm^2$ and $1.10kg/cm^2$, this system was stable without sudden fouling. Finally, the quality of effluent is satisfied the guidelines for potable water quality such as turbidity, color, E.coli, Mn, Al, Fe and so on.

A Study on the change of Ecological Environment in Cave cause by the Pollution of Cave Environment and Analysis of Environmental Pollutants in Cave (환경오염으로 인한 동굴생태환경의 변화와 환경오염물질 분석에 관한 연구)

  • 이경호
    • Journal of the Speleological Society of Korea
    • /
    • no.61
    • /
    • pp.5-16
    • /
    • 2000
  • Recently many environmental researcher are concerned about the ecological environment and the issue of environmental pollution in cave. In this paper we discuss about air pollution, water pollution, state of water quality, ecological environment and situation of environmental public damage in cave The concerning of air pollution in cave is mainly to the type of secondary contamination, which much is developed in various fields recently. The natural water in the most of cave is no problems but ground water has slitting with natural water during much raining period. The state of water quality is gradually contaminated with artificial environmental pollution, that is, the contents of kinds of Aluminum, Nickel, Copper, Zinc and Calcium are higher than before. On the other hand it is very important things to keep the control of constant temperature, darkness and humidity in cave. The contamination by lamp flora and even black colored contamination are appeared nowadays. The ecological environment in cave destructed by growing of mi coorganism. In fact the internal of cave is shielded with the state of climate of cave external but the environment of internal cave is contaminated, because blowing from external climate state. In addition to environmental pollution caused by carbon dioxide and body temperature of tourists. By the way eco-examination of cave is black color public damage, green color one and white color one has been discovered, so we need to have the situation of demand of environmental reservation alternatives.

  • PDF

Water Physiology of Panax ginseng III. Soil moisture, physiological disorder, diseases, insects and quality (인삼의 수분생리 III. 토양수분, 생리장해, 병해충과 품질)

  • Park, Hoon
    • Journal of Ginseng Research
    • /
    • v.6 no.2
    • /
    • pp.168-203
    • /
    • 1982
  • Effects of soil moisture on growth of Panax ginseng, of various factors on soil moisture, and of moisture on nutrition, quality, physiological disorder, diseases and insect damage were reviewed. Optimum soil moisture was 32% of field capacity with sand during seed dehiscence, and 55-65% for plant growth in the fields. Optimum soil moisture content for growth was higher for aerial part than for root and higher for width than for length. Soil factors for high yield in ginseng fields appeared to be organic matter, silt, clay, agreggation, and porosity that contributed more to water holding capacity than rain fall did, and to drainage. Most practices for field preparation aimed to control soil moisture rather than nutrients and pathogens. Light intensity was a primary factor affecting soil moisture content through evaporation. Straw mulching was best for the increase of soil moisture especially in rear side of bed. Translocation to aerial part was inhibited by water stress in order of Mg, p, Ca, N an Mn while accelerated in order of Fe, Zn and K. Most physiological disorders(leaf yellowing, early leaf fall, papery leaf spot, root reddening, root scab, root cracking, root dormancy) and quality factors were mainly related to water stress. Most critical diseases were due to stress, excess and variation of soil water, and heavy rain fall. The role of water should be studied in multidiciplinary, especially in physiology and pathology.

  • PDF

Biofouling and Microbial Induced Corrosion -A Case Study

  • Mohammed, R.A.;Helal, A.M.;Sabah, N.
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • In industrial and fluid handling systems, frequently the protective film forming materials suffer from severe corrosion due to microbial effects. As an example, various micro-organisms, including bacteria, exist in seawater normally fed to power and desalination plants. Unless seawater intakes are properly disinfected to control these microbial organisms, biological fouling and microbial induced corrosion (MIC) will be developed. This problem could destroy metallic alloys used for plant construction. Seawater intakes of cogeneration plants are usually disinfected by chlorine gas or sodium hypochlorite solution. The dose of disinfectant is designed according to the level of contamination of the open seawater in the vicinity of the plant intake. Higher temperature levels, lower pH, reduced flow velocity and oxidation potential play an important role in the enhancement of microbial induced corrosion and bio-fouling. This paper describes, in brief, the different types of bacteria, mechanisms of microbiological induced corrosion, susceptibility of different metal alloys to MIC and possible solutions for mitigating this problem in industry. A case study is presented for the power plant steam condenser at Al-Taweelah B-station in Abu Dhabi. The study demonstrates resistance of Titanium tubes to MIC.