• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.042 seconds

Characteristics and Drug Release Control of Crosslinked Poloxamer Hydrogel (가교 폴록사머 하이드로겔 물성 및 약물 조절 방출)

  • Byun, Eun-Jung;Lee, Seung-Jin;Kim, Kil-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.3
    • /
    • pp.201-205
    • /
    • 1996
  • Poloxamer, block copolymers of ethylene oxide and propylene oxide was crosslinked by diisocyanates and triisocyanates to form water-swellable, physically strong, rubber-like elastic, high biocompatible polyurethanes. The isocyanate-hydroxyl stoichiometry was kept 1:1, but the crosslinking density was varied. The variations examined were the ratio of diisocyanate and triisocyanate. The delivery of two drugs of different water solubilities from hydrogel matrices was studied. It appeared that the drug nature greatly influenced its release kinetics possibly due to drug-polymer interactions. The release profiles, however, could be modified to a great extent by adjusting the polymer network structure Generally the high crosslinking density was required for prolonged drug delivery.

  • PDF

Reinforcement of Concrete Structure by Impregnation of Molten Sulfur (용융황 침투에 의한 콘크리트 구조물의 물성 증진에 관한 연구)

  • 김종국;오준택;설용건;김우식
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.6
    • /
    • pp.729-736
    • /
    • 1989
  • This study aims to reinforce concrete structure by impregnation of molten sulfur. The improved properties of sulfur impregnated concerete were confirmed by compressive strength test and water proof effect. Following variables were adopted to evaluate impregnation parameters ; 1) the effect of water content in concrete structure (0-8%) 2) impregnation time of molten sulfur(0-22hr) 3) impregnation temprature of molten sulfur(13$0^{\circ}C$, 14$0^{\circ}C$). In partial ponding experiments, the concrete specimen of sulfur impregnated by 2wt% yields 1.5 times higher value of compressive strength than that of control one(non-impregnated concerte). In complete ponding experiments, the mortar specimen of slufur impregnated by 12-14wt% yields 2-3 times higher value of compressive strength than that of control one (non-impregnated mortar). From the examination of X-ray diffractions, $\alpha$-sulfur was found in concrete pores. Homogeneous impregation of molten sulfur into concrete pores was also identified with poresize analysis and micrographs of SEM.

  • PDF

수처리용 분리막 모듈 설계 및 오염 방지

  • 정건용
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.87-109
    • /
    • 1997
  • Reverse osmosis(R/O), ultrafiltration(UF) and microfiltration (MF) processes are widely used for water treatment. In the seminar, characteristics of typical membrane modules including tubular, hollow fiber, plate and frame and spiral wound types will be discussed in detail. The design methods based on hydrodynamics for hollow fiber and spiral wound modules will be introduced analytically. Concentration polarization (CP) and membrane fouling mechnism as well as the techniques for CP reduction will be handled. The CP control techniques contain chemically modified membrane surface, pretreatment of feed water, operation of low trans-membrane pressure, chemical or physical cleaning methods and artificial production of various fluid turbulences near the membrane surface, etc. In especially, the recent commercial membrane modules for CP control including module rotation, vibration and Taylor or Dean vortex system will be introduced and discussed in detail.

  • PDF

Improvements of Inflow Controller Installed in Storm Overflow Diverging Tank for CSOs Control (우수토실에 설치된 월류수 제어를 위한 유입유량조절장치의 개선효과)

  • Lim, Bong-Su;Park, Youn-Hae;Kim, Tae-Eung
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This study was carried out to evaluate the performance of a inflow controller for the control of combined sewer overflows (CSOs). Because of the inflow controller could be adjusted manually by predicting the maximum amount of peak flow, the mechanical adjustment of this controller was higher than the existing fixed-type controller in field application. Standardizing the relationship between the flow and the clearance and angle of an inlet cover plate on the inflow conditions can selected to the optimum conditions for the on-site. It was concluded that BOD pollutant loading at the region in which inflow controller was installed had shown the removal efficiency rate of 42%.

Reliability Assessment by the Scoring Model for the Advanced Pressurized water Reactor 1400MWe Project Selection under Uncertainty (신형경수로 1400을 위해 점수산정 모형에 의한 신뢰성 평가)

  • 강영식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.25 no.6
    • /
    • pp.23-35
    • /
    • 2002
  • The problem of system reliability is very important issue in the digitalized nuclear power plant, because the failure of its system brings about extravagant economic loss, environment destruction, and fatal damage of human. Therefore the purpose of this study has developed the reliability evaluation model through the scoring model by the quantitative and qualitative factors in order to justify the evaluation considering the advanced safety factors in the Advanced Pressurized water Reactor 1400MWe(APR 1400MWe) under uncertainty. Especially, the qualitative factors considering the human, information control, and quality factors for the systematic and rational justification have been closely analyzed. The proposed model can be simply applied in real fields in order to minimize the industrial accidents in the digitalized nuclear power plant.

Chemical Properties of Co(II) Compound Containing Endocrine Disrupter, Bis-Phenol A

  • Park, Chil-Nam
    • Journal of Environmental Science International
    • /
    • v.11 no.2
    • /
    • pp.131-137
    • /
    • 2002
  • The chemical behavior and properties on the redox state of environmental pollutant has been investigated by electrochemical methods. We carried out to measure the variations in the redox reaction of differential pulse polarogram and cyclic voltammogram. The results observed the influences on redox potential and current of various factors with temperature and pH. These were established factors as the effect of the redox reaction. It can be clearly recognized that the electrode reaction are from qusi-reversible to irreversible processes. Also, it was mixing with reaction current controlled. The bits-phenol A in the waste water was made to compound with cobalt ion and it take away from the separation into compound. The $Co(BPA)_2$ compound was not found to be dissociation in waste water. However, this compound is avery unstable(K=1.02) and for a while, it was to be a dissociation. Therefore, we believed that it was likely to a toxic substance.

Analysis on Initial Stability Test Results of Underwater Vehicle Using the HR Propulsion System (HR추진기관을 이용한 수중운동체의 초기안정성 시험 결과 분석)

  • Hwang, Heeseong;Kim, Hakseong;You, Youngjoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1142-1143
    • /
    • 2017
  • In this paper, Underwater propulsion test of SWASH(Small Waterplane Area Single Hull) type underwater vehicle with hybrid rocket system is performed. Watertight structure is applied to prevent a combustion chamber from water, and the control logic is constructed by setting the watertight ignition sequence. As a results, It is confirmed that the ignition is stable in water, and the propulsion system works well along the configured control sequence.

  • PDF

Performance of an inverter refrigeration system with a change of expansion devices (인버터형 냉동시스템의 팽창장치 변경에 따른 성능특성)

  • 이용택;김용찬;박윤철;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.928-936
    • /
    • 1999
  • An experimental study was performed to investigate characteristics of an inverter driven water-to-water refrigeration system with a variation of compressor frequencies and expansion devices. The frequency of a compressor varied from 30Hz to 75Hz, and performance of the systems applying three different expansion devices such as capillary tube, thermostatic expansion valve(TXV), and electronic expansion valve(EEV) were measured. The load conditions were altered by varying the temperature of the secondary fluid entering condenser and evaporator with a constant flow rate. When the test conditions were deviated from the standard value(rated value), TXV and EEV showed better performance than capillary tube due to optimum control of mass flow rate and superheat. In the present study, it was observed that the variable area expansion device had better performance than constant area expansion device in an inverter refrigeration system due to active control of flow area with a change of compressor frequency and load conditions.

  • PDF

An Analysis on the Usage of Pumped Hydro Storage as a Non-Spinning Reserve Power (양수발전기의 대기예비력 활용방안 분석)

  • Jeong, Seung-Hoon;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Total capacity of pumped hydro storage(PHS) in Korean power system reaches 4,700MW, though the share of it is about 4.56% of total capacity The Unit Commitment program, E-terracommit which is used for the operational purpose by KPX, includes the PHS model. But the model has a defect that it does not include the information of water level of upper reservoir. Therefore two types of improved the PHS models are represented in this paper. The first model is a optimized model by connecting the upper reservoir water level to the non-spinning reserve. The other model is to have priority allocate both the PHS and combined cycle generator for non-spinning reserve. The proposed two models and the E-terracommit model is compared and resulting to have improvement in estimating non-spinning reserve when using the proposed models.

Automtical Control System of GreenHouse Using Sensing Information (이벤트 알림서비스를 이용한 효율적인 비닐하우스 모니터링 애플리케이션)

  • Lee, Ju-Kyung;Ahn, Hyeon-Woo;Jeong, Sang-Woo;Song, Teuk-Seob;Jeon, Yong-Ha;Kim, Hae-Young;Kwak, Nae-Joung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.539-540
    • /
    • 2017
  • In this paper, we propose system that automatically controlls greenhouse to make best environment to grow crops. The proposed system is consist of the function to automatically open and close water-roof, control the tubular well of ground water and remotely monitor information of greenhouse.

  • PDF