• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.04 seconds

Effect of Zeta Potential of Clay and Algae Particles on Flotation Efficiency (점토와 조류입자의 제타전위가 부상분리 효율에 미치는 영향)

  • Choi, Do-Young;Kim, Seong-Jin;Jung, Heung-Jo;Lee, Se-Ill;Paik, Do-Hyeon;Lee, Jae-Wook;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.437-445
    • /
    • 2005
  • Zeta potential is a key parameter of double layer repulsion for individual particles and can usually be used to interpret the trend of coagulation efficiency. This study focused on the measurement of zeta potential of algae and clay under various experimental conditions including water characteristics (pure water, stream water, reservoir water) and coagulant dose (10~50 mg/L). Results showed that the variation of zeta potential was highly sensitive depending on the water characteristics and coagulation conditions. Zeta potential of two genera of algae (anabaena sp. and microcystis sp.) were changed highly with coagulant dosage, especially. On the basis of trajectory analysis, bubble-floc collision efficiency simulated in terms of zeta potential was fitted well with removal efficiency of chlorophyll-a from algae particles. It was found that the control of zeta potential was important for effective removal of algae particles.

Changes in Photosynthetic Performance and Water Relation Parameters in the Seedlings of Korean Dendropanax Subjected to Drought Stress (건조 스트레스에 따른 황칠나무 유묘의 광합성과 수분특성인자 변화)

  • Lee, Kyeong Cheol
    • Korean Journal of Medicinal Crop Science
    • /
    • v.26 no.2
    • /
    • pp.181-187
    • /
    • 2018
  • Background: This study aimed to investigate out the influence of drought stress on the physiological responses of Dendropanax morbifera seedlings. Methods and Results: Drought stress was induced by discontinuing water supply for 30 days. Under drought stress, photosynthetic activity was significantly reduced with decreasing soil water content (SWC), as revealed by the parameters such as Fv/Fm, maximum photosynthetic rate ($P_{N\;max}$), stomatal conductance ($g_s$), stomatal transpiration rate (E), and intercellular $CO_2$ concentration (Ci). However, water use efficiency (WUE) was increased by 2.5 times because of the decrease in $g_s$ to reduce transpiration. Particularly, E and $g_s$ were remarkably decreased when water was withheld for 21 days at 6.2% of SWC. Dendropanax morbifera leaves showed osmotic adjustment of -0.30 MPa at full turgor and -0.13 MPa at zero turgor. In contrast, the maximum bulk modulus of elasticity ($E_{max}$) did not change significantly. Thus, Dendropanax morbifera seedlings could tolerate drought stress via osmotic adjustment. Conclusions: Drought avoidance mechanisms of D. morbifera involve reduction in water loss from plants, through the control of stomatal transpiration, and reduction in cellular osmotic potential. Notably photosynthetic activity was remarkably reduced, to approximately 6% of the SWC.

Performance of the Geothermal Heat Pump using Vapor Injection for Hot Water (증기분사를 적용한 고온수용 지열 히트펌프의 성능특성)

  • Park, Yong-Jung;Park, Byung-Duck
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.3
    • /
    • pp.297-304
    • /
    • 2014
  • The purpose of this study is to evaluate the experimental performance characteristics of a water-to-water geothermal heat pump featuring a vapor refrigerant injection for the production of hot water. The performance of geothermal heat pump with a vapor injection was evaluated by comparing with that of a conventional geothermal heat pump without a vapor injection. For heating operation, the geothermal heat pump with a vapor injection is superior in COP and heating capacity. The vapor injection was more effective for supplying hot water while overloading. The vapor injection was effective for the improvement of the cooling capacity. However, the vapor injection was not effective for the increasing of COP according to the increased input of a compressor. The advantage of vapor injection in water-to-water geothermal heat pump become disappeared while cooling operation with lower part loading.

Seasonal Phosphorus Dynamics in a Forest Stream Water Following Different Harvests

  • Park, Byung Bae
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.2
    • /
    • pp.181-186
    • /
    • 2008
  • Even small changes in phosphorus concentrations in stream water could cause eutrophication because of very low level of phosphorus concentrations in natural waters. I investigated the impact of strip cut and clear cut on phosphorus concentrations in stream water at the Hubbard Brook Experimental Forest and investigated stream water phosphorus concentrations as a function of flow rate and season (as well as cutting history). Mean phosphate concentrations in the control (undisturbed forest) increased $1.9{\mu}g\;L^{-1}\;to\;2.6{\mu}g\;L^{-1}$, while strip cut treatment increased phosphate concentrations in stream water $2.2{\mu}g\;L^{-1}\;to\;3.7{\mu}g\;L^{-1}$ during the same period. There was no significant effect of clear cut treatment on phosphate concentrations in stream water. No relationships were found between discharge rate and phosphate concentrations, but the magnitude of fluctuation were increased during two decades in undisturbed forest: $1-5{\mu}g\;L^{-1}$ from 1963 to 1975 and $1-12{\mu}g\;L^{-1}$ from 1983 to 1995. Based on this study, forest harvests with buffer zone will not make a problem by imported phosphate to cause eutrophication in natural water.

The Characteristics of Toxin Production in the Korean Toxic Cyanobacteria (국내산 유독 남조류의 독소생산 특성)

  • Kim, Hwa-Bin;Park, Hae-Kyung;Shin, Kyodong;Moon, Jeong-Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.834-840
    • /
    • 2010
  • To find out the toxin production characteristics of Korean harmful cyanobacteria, we isolated 14 cyanobacterial strains from Korean lakes and rivers and analyzed the kinds and cellular content of microcystins (MCYSTs) of cyanobacterial isolates using cultured biomass. And we measured the MCYSTs production by growth phase of two representative toxic strains, Microcystis aeruginosa (HG-015) and Anabaena planktonica (HG-012). Among seven cyanobacteral species, Microcystis wesenbergii showed the highest cellular MCYSTs content. MCYST-RR was the most dominant toxin reaching more than 85% of MCYSTs produced by isolated cyanbacterial strains. During the mass culture, Microcystis aeruginosa (HG-015) showed the highest yield and accumulation of MCYSTs in the exponential growth phase. However the cellular content of chlorophyll a and MCYSTs of Anabaena planktonica (HG-012) showed higher value in the stationary and early death phase than in the exponential growth phase. Our results suggest that control and removal of harmful cyanobacterial bloom before exponential growth phase may be effective to prevent health risk of cyanobacterial toxins in the drinking water sources.

Rainwater Harvesting System as an Alternative Water Source

  • Kim, Phil-S.;Yoo, Kyung-H.;Kim, Sun-Joo;Lee, Nam-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.524-528
    • /
    • 2009
  • The objectives of this study were to install RCR systems at a typical single family house and a school in Alabama, and evaluate the feasibility and efficiency of using the RCR systems for water harvesting in Alabama. The RCR systemswere equipped with a control system and a CR10X data logger to monitor the system operation and to collect data on precipitation, temperature, overflow, water depth in the storage tank and daily uses of toilet flushing. Daily average water use of the home for toilet flushing was 95 liter and 2100 liter was used at the school during the school days. Rainwater harvesting efficiency was 83.3 and 89 percent and RCR use efficiency was 18 and 98 percent from the home and the school, respectively. A computer program was developed to estimate potential effectiveness of RCR systems. From the analysis result with 10 years rainfall data, a total of 67,000 liters of rainwater could be harvested for domestic uses from a typical single family house which supplies 190 liters per day.

  • PDF

The Evaluation of Water Quality in the Mankyung River using Multivariate Analysis (다변량해석기법을 이용한 수계의 수질평가)

  • O, Yeon Chan;Lee, Nam Do;Kim, Jong Gu
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.233-244
    • /
    • 2004
  • This study was conducted to evaluate water quality in the Mankyung River using multivariate analysis. The analysis data which was surveyed from January 1996 to December 2002 in Mankyung river was aquired by the ministry of environment. Twelve water quality parameters were determined on each survey. The results were summarized as follow; Water quality in the Mankyung River could be explained up to 74.90% by four factors which were included in loading of organic matter and nutrients by the tributaries(43.28%), seasonal variation(10.40%), loading of pathogenic bacteria by domestic sewage of Gapcheon (12.41%) and internal metabolism in river(8.81%). The result of cluster analysis by station was classified into three group that has different water quality characteristics. Especially, Iksan river was appeared to considerable water quality characteristics against other station. In monthly cluster analysis, three group was classified by seasonal characteristics. Also, in yearly cluster analysis, three group was classified. It is necessary to control the pollutant loadings by domestic sewage and livestock waste for water quality management of Mankyung river.

A Study on the Optimal Use of Silent Discharge Type Ozonizer in Purification Plant (정수장의 무성방전형 오존발생기 최적활용방안에 관한 연구)

  • Shin, Hong-Sub;Park, Hyun-Mi;Kwon, Young-Hak;Song, Hyun-Gig;Park, Won-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.54-60
    • /
    • 2015
  • There are 5 purification plants with the adopted advanced water purification treatment process in Korea. Annual operating costs were 8,990 million won including purchase cost of oxygen and power usage charges. We need research to optimize, in the future, when considering the direction of domestic water treatment continues to adopt advanced water treatment process. In this paper, calculate the optimal operating costs by injected the oxygen gas, used power cost. approximately 25% of the operating costs can be reduced when injected the ozone gas is 1.0ppm than 2.0ppm, the necessary amount of oxygen is increased then power is lower. so operating costs are decided according to oxygen costs. On the other hand, high ozone concentration 2.0ppm, the necessary power is increased then amount of oxygen is lower. Therefore, in the case of G purification plant, the controlling factor of the input ozone concentration 2ppm, PID control operation by setting the concentration of over 10Wt% is efficient. The installed capacity is the more little the more better when considering on Ozone injection rate in the process of water treatment.

Application of Water Quality Management System of Freshwater Lake

  • Kim, Sun-Joo;Kim, Phil-Shik;Lee, Joo-Young
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.38-48
    • /
    • 2003
  • Lake water quality assessment information is useful to anyone involved in lake management, from lake owners to lake associations. It provides lake water quality criteria, which can improve the ways how to manage out lake resources and how to measure current conditions. It also provides a knowledge base so that the lakes can be protected and restored. Here, the Freshwater Lake Water Quality Management System(FLAQUM) was developed. The results of FLAQUM application by scenario proved that pollutant load at rainfall by the nonpoint sources was much more than normal times at rainfall. From the result of Scenario I (pollutant source increase case), the concentrations of Boryeong freshwater lake were BOD 9.43mg/L, T-N 4.53 mg/L and T-P 0.21 mg/L, respectively, and those values exceed the standard of agricultural water. And in case of Scenario I and II(the present case) excluding Scenario III (pollutant source decrease case), all of T-N and T-P are either mesotrophication or eutrophication, on the other hand when 60% of pollution source is removed, the concentrations of Scenario III were BOD 3.21 mg/L, T-N 0.95 mg/L, T-P 0.11 mg/L, respectively, and which satisfies the standard of agricultural water quality.

Prediction of Reservoir Water Level using CAT (CAT을 이용한 저수지 수위 예측)

  • Jang, Cheol-Hee;Kim, Hyeon-Jun;Kim, Jin-Taek
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.1
    • /
    • pp.27-38
    • /
    • 2012
  • This study is to analyse the hydrological behavior of agricultural reservoir using CAT (Catchment hydrologic cycle Assessment Tool). The CAT is a water cycle analysis model in order to quantitatively assess the characteristics of the short/long-term changes in watershed. It supports the effective design of water cycle improvement facilities by supplementing the strengths and weaknesses of existing conceptual parameter-based lumped hydrologic models and physical parameter-based distributed hydrologic models. The CAT especially supports the analysis of runoff processes in paddy fields and reservoirs. To evaluate the impact of agricultural reservoir operation and irrigation water supply on long-term rainfall-runoff process, the CAT was applied to Idong experimental catchment, operated for research on the rural catchment characteristics and accumulated long term data by hydrological observation equipments since 2000. From the results of the main control points, Idong, Yongdeok and Misan reservoirs, the daily water levels of those points are consistent well with observed water levels, and the Nash-Sutcliffe model efficiencies were 0.32~0.89 (2001~2007) and correlation coefficients were 0.73~0.98.