• Title/Summary/Keyword: water control

Search Result 12,102, Processing Time 0.039 seconds

Effect of Water Soluble Extract of Lichens on Oxidative Phosphorylation and Level of Metabolite in Rat Liver (지의류(地衣類) 추출물을 섭취한 흰쥐 간의 산화적 인산화 과정 및 대사물 측정(II))

  • An, Mi-Jung;Suh, Jung-Soon;Lee, In-Ja;Cho, Sung-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.14 no.2
    • /
    • pp.145-150
    • /
    • 1985
  • This study was conducted to examine the pharmacological effect of water soluble extract of Lichens (Parmelia, Physcia and Cladonia species) on liver-damaged rat by $CCl_4$ injection. Rat livers were damaged acutely and chronically by one-time injection of $CCl_4$ just prior to five days of experimental period and continuous injections in every three days for eight weeks of experimental period, respectively. During each period the experimental group was fed Lichens extract(5.5 mg of dry wt/ml) instead of water given to the control group. For both acute and chronic liver damage, the experimental group showed higher oxidative activity of hepatic mitochondria measured by state 3 respiration, P/O ratio, respiratory control and ATP synthesized, compard to the control group. Serum glucose was slightly higher in the experimental group but liver glycogen showed no significant difference between experimental and control groups. In experimental group, liver glucose-6-phosphatase activity was increased during first two days after acute liver damage, but not significantly different from control group during chronic damage. Liver lactate, malate plus fumarte and glutamate tended to be higher in the experimental group, especially for chronic liver damaged rat. It is concluded that Lichens extract stimulate cytoplasmic and mitochondrial oxidative activities and the possible mechanism of the latter is supposed to involve the preservation of membrane integrity by certain component(s) of water-soluble Lichens extract.

  • PDF

A study on the development of quality control algorithm for internet of things (IoT) urban weather observed data based on machine learning (머신러닝기반의 사물인터넷 도시기상 관측자료 품질검사 알고리즘 개발에 관한 연구)

  • Lee, Seung Woon;Jung, Seung Kwon
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1071-1081
    • /
    • 2021
  • In addition to the current quality control procedures for the weather observation performed by the Korea Meteorological Administration (KMA), this study proposes quality inspection standards for Internet of Things (IoT) urban weather observed data based on machine learning that can be used in smart cities of the future. To this end, in order to confirm whether the standards currently set based on ASOS (Automated Synoptic Observing System) and AWS (Automatic Weather System) are suitable for urban weather, usability was verified based on SKT AWS data installed in Seoul, and a machine learning-based quality control algorithm was finally proposed in consideration of the IoT's own data's features. As for the quality control algorithm, missing value test, value pattern test, sufficient data test, statistical range abnormality test, time value abnormality test, spatial value abnormality test were performed first. After that, physical limit test, stage test, climate range test, and internal consistency test, which are QC for suggested by the KMA, were performed. To verify the proposed algorithm, it was applied to the actual IoT urban weather observed data to the weather station located in Songdo, Incheon. Through this, it is possible to identify defects that IoT devices can have that could not be identified by the existing KMA's QC and a quality control algorithm for IoT weather observation devices to be installed in smart cities of future is proposed.

A Study on the Water Quality Management of Modular Revetment Structure installed Low-Maintenance Constructed Wetland (플랜터형 호안구조물을 설치한 저관리형 습지의 수질 제어 기작에 관한 연구)

  • Ham, Eun Kyung;Choi, Yun Eui;Kim, Min;Chon, Jinhyung
    • Journal of Wetlands Research
    • /
    • v.17 no.2
    • /
    • pp.184-192
    • /
    • 2015
  • This study is a basic research for low maintenance constructed wetlands which can prevent water quality deterioration due to wetland soils. The purpose of this study is to analyze water quality control mechanisms of constructed wetland on the artificial ground which installed the modular revetment structure(MRS), a device that separates water and soil. This study was then conducted with two different wetland mesocosms (a treatment plot and a control). These mesocosms were monitored to analyze effects of water quality control of the MRS. A treatment plot was built, and separated into soil and water, by filling the MRS with the decomposed granite soil in the mesocosm made of rubber material. A control plot was built where the decomposed granite soils were exposed to water by leaving the soil on the bottom of the mesocosm made of rubber material. Water quality was then analyzed by using Kolmogorov-Smirnov Z examination which then showed that pH, BOD, SS, Chl-a, T-P, T-N had statistically valid difference between a container with the MRS and one without it. According to the analysis of the water quality, the temperature and the EC level came out similarly and both mesocosm showed same level on pH and DO. A treatment plot had higher levels of BOD, SS Chl-a, and T-P. A control plot's T-N value was little lower than that of the treatment plot. This study suggests method of constructed wetlands using the MRS prevents problems occurring in wetland soils: aridity of wetlands by soil erosion, eutrophication, and algal blooms due to nutrients released from wetland soil. These functions of constructed wetland with the MRS increase aesthetic, ecologic, social, and economic value of the wetland. Outcomes of this research will later enable more proficient way of stabilizing water quality and provide data for planning low maintenance constructed wetlands.

Future Direction of Water Quality Standards in Korea (우리나라 물환경 기준의 개선방향)

  • Lee, Jae-Kwan;Cho, Soon;Chung, Il-Rok;Hwang, Soon-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.737-747
    • /
    • 2006
  • Ministry of Environment (MOE) of Korea has been implementing the water quality management policy to focus on the control of organic matters (BOD and COD) for 28 years since 1978 when the water quality standards had been established. However, the government and the public have begun to recognize the necessity of creating the best water environment for people and aquatic life, and also formulating the various measures of water pollution, Consequently, MOE of Korea is establishing the basic plan of water environment management, with the vision of "Clean Water, Eco River 2015." The major targets of water environment management plan are to maintain ecosystem health and to protect water quality from various hazardous substances in water bodies. In order to achieve the major targets, it is essential to amend the water quality standards, which bring about the systematic management of various pollutants and healthy ecosystem. Introduction of the new techniques of water environment assessment is also prerequisite to maintain sustainable water environment. These can be accomplished under the consideration of following suggestions in environmental quality standards. First, several criteria should be complemented in water quality standards; they include the improvement of the current water quality classification system, the strengthening and supplement of relevant parameters considering human health in the standards, the introduction of biotic indices, and management standards on eutrophication. Secondly, it should be considered to introduce the biological water quality standards using biotic indices and the management standards for sediments. Lastly, it needs to introduce or develop an ecological status classification which could be used in the assessment of the water environment as a whole.

Antitumor and Immunostimulating Activities of $Elfvingia$ $applanata$ Hot Water Extract on Sarcoma 180 Tumor-bearing ICR Mice

  • Shim, Sung-Mi;Lee, Jae-Seong;Lee, Tae-Soo;Lee, U-Youn
    • Mycobiology
    • /
    • v.40 no.1
    • /
    • pp.47-52
    • /
    • 2012
  • $Elfvingia$ $applanata$, a medicinal mushroom belonging to Basidiomycota, has been used in the effort to cure cancers of the esophagus and stomach, and is also known to have inhibitory effects on hepatitis B virus infection. The hot water soluble fraction (as Fr. HW) was extracted from fruiting bodies of the mushroom. $In$ $vitro$ cytotoxicity tests showed that hot water extract was not cytotoxic against cancer cell lines such as Sarcoma 180, HT-29, HepG2, and TR at concentrations of 10-2,000 ${\mu}g/mL$. Intraperitoneal injection with Fr. HW resulted in a life prolongation effect of 45.2% in mice previously inoculated with Sarcoma 180. Treatment of Fr. HW resulted in a 2.53-fold increase in the numbers of murine spleen cells at a concentration of 50 ${\mu}g/mL$, compared with control. Incubation of murine spleen cells with Fr. HW at a concentration of 500 ${\mu}g/mL$ resulted in improved immune-potwntiating activity of B lymphocytes through an 8.3-folds increase in alkaline phosphatase activity, compared with control. Fr. HW generated 12.5 ${\mu}M$ of nitric oxide (NO) when cultured with RAW 264.7, a mouse macrophage cell line, at the concentration of 50 ${\mu}g/mL$, while lipopolysaccharide, a positive control, produced 15.2 ${\mu}M$ of NO. Therefore, the results suggested that antitumor activities of Fr. HW from $E.$ $applanata$ might, in part, be due to host mediated immunostimulating activity.

Pollutant Control using the Separation Wall between Stormwater and Sewage in a Combined Sewer System (우오수분리벽을 이용한 합류식 하수관거의 오염물질 제어효과)

  • Lee, Kuang Chun;Choi, Bong Choel;Lim, Bong Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.461-469
    • /
    • 2004
  • This research is to determine the stormwater effects on sewer concentrations by measuring and comparing the flow and pollutant concentrations during dry and rainy periods in the existing BOX type combined sewer pipes. The monitoring was carried out in two sites, which are the Daesachen outfall having PE separation wall in BOX type combined sewer pipes and the Yongunchen outfall not having seperatioin wall. The average flow-weighted BOD concentraion in Yongunchen outfall is 2-fold lower than in Daesachen outfall because of the dilution effect from ravine water. However, the pollutant mass loading is 16 fold higher in Yongunchen outfall than in Daesachen outfall because of more flows. According to the research, the separation wall controls 52% pollutant mass during a storm period (11.5 mm/hr rainfall intensity). Therefore, the Yongunchen combined sewer system (CSS) need separation wall to control and to prevent more pollutant input in stream. In Daesachen area, the maximum sewer flow rate during a storm period measured about 10 fold bigger than average sewer flow during dry periods. Also the concentrations between rainy and dry periods increase approximately 33 fold for BOD and 120 fold for SS. In Yongunchen area, it increases about 9 fold for the maximum flow rate, 18 fold for BOD and 22 fold for SS during a storm. Therefore, the research is concluded that the separation wall between stromwater (or ravine water) and sewage can decrease the dilution effect in CSS and control the pollutant loading.

Effect of Soy Protein Hydrolysates Prepared by Subcritical Water Processing on the Physicochemical Properties of Pork Patty during Chilled Storage

  • Lee, Yun-Kyung;Ko, Bo-Bae;Min, Sang-Gi;Hong, Geun-Pyo
    • Food Science of Animal Resources
    • /
    • v.35 no.4
    • /
    • pp.557-563
    • /
    • 2015
  • The present study was carried out to investigate the effects of soy protein hydrolysates (SPHs) addition on the quality characteristics of pork patties. The SPHs was prepared by subcritical water process (SWP) at 180℃ without holding time and mixed with the pork patty components at varying concentrations (0-3%), and the patties were stored at 4℃ for 14 d. As quality parameters, instrumental color, thiobarbituric acid-reactive substances (TBARS), pH, water holding capacity (WHC) and shear force were measured at the end of storage. Regardless of SPHs concentration, the addition of SPHs significantly manifested low L* and high a* values compared to those of untreated control (p<0.05). For b* value, addition of SPHs in the 0.5-1.5% was unaffected, while >2.0% of SPHs caused significantly lower b* than control (p<0.05). The color changes in pork patties with and without SPHs were also identified in visual appearance where the pork patties containing 0.5-2.0% showed bright red color which was comparable to brownish color of control and patties containing >2.5% SPHs. Lipid oxidation was delayed by the addition of 0.5-1.5% SPHs, while it was accelerated by the addition of 3% SPHs. The pH of patties increased with increasing concentration of SPHs, whereas there were no significant differences in WHC and shear force of patties. Consequently, the results indicated that the addition of 0.5-1.5% SPHs had a potential advantage in suppressing oxidative deterioration of fat-containing meat products during chilled storage.

A Study on Control Disinfection By-products in High Sodium Hypochlorite Generation (고농도 차아염소산나트륨 발생장치의 소독부산물 제어에 관한 연구)

  • Cho, Haejin;Shin, Hyunsoo;Ko, Sungho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.183-189
    • /
    • 2017
  • Sodium hypochlorite used in water disinfection processes is generally in the production of chlorine to 0.8%. As the dose of chlorine increases, disinfection by-products (Chlorate) also increase simultaneously and exceed water quality standards. In this study, the electrolytic cell of a sodium hypochlorite generator (12% chlorine) was adjusted to control the production of the disinfection by-products. As a result, it was possible to reduce Chlorate concentrations by more than 95% by adjusting the pH of the electrolytic cell from 1.53 to 4.2 (normal pH of the electrolytic cell). As a low current is required to obtain these results, a 15% improvement in the efficiency of the positive electrode is also observed. For the development of High Sodium Hypochlorite Generation can be used in a safe sodium hypochlorite solution, which is expected to contribute to improvement in the safety of the disinfection process.

Biochemical Studies on Colon Tumor Non-Promoting Effect of Green Tea Extract in Chemical Carcinogen-Treated Rats (화학적 발암원을 투여한 쥐에서 녹차 추출물의 대장암 억제효과에 관한 생화학적 연구)

  • 박현서
    • Journal of Nutrition and Health
    • /
    • v.33 no.6
    • /
    • pp.632-638
    • /
    • 2000
  • This study was designed to observe the effect of green tea on colon tumor incidence and biomarkers of colon carcinogenesis in 1, 2-dimethlhydrazine-treated rats. Male Sprague Dawley rats at 7 weeks of age were divided into two groups: control and green tea(GT) groups. Control rats had distilled water as drinking water but GT group received green tea extracts(2.5%, w/v water) as drinking water throughout the experiment periods. All rats were fed the experimental diet containing 15% fat by weight for 20 weeks. and were i.m. injected with DMH for 6 weeks to give total dose of 180mg/kg body weight. Tumor incidence was reduced in GT group (39%) compared with control group (56%) Green tea significantly reduced cell proliferation (total cells per crypt, crypt length and proliferative zone) in colonic mucosa and also significantly reduced the levels of preformed prostalandin E2(PGE2) and thromboxance B2(TXB2) in colonic mucosa but the fatty acid profile of total lipid in colonic mucosa was not significantly influenced by green tea. However the relative percent of C20:4 and the levels f preformed PGE2 and TXB2. were significantly higher in tumor tissue compared with normal surrounding mucosa.Green tea increased the fecal excretion of total bile acid but not scondary bile acid which is known as one of promoters for colon cancer,. These results suggest that green tea could have preventive effect against colon cancer when consumed daily by influencing on antioxidant effect and the metabolism of arachidonic acid.

  • PDF

OPTIMUM STORAGE REALLOCATION AND GATE OPERATION IN MULTIPURPOSE RESERVOIRS

  • Hamid Moradkhani
    • Water Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.57-62
    • /
    • 2002
  • This research is intended to integrate long-term operation rules and real time operation policy for conservation & flood control in a reservoir. The familiar Yield model has been modified and used to provide long-term rule curves. The model employs linear programming technique under given physical conditions, i.e., total capacity, dead storage, spillways, outlet capacity and their respective elevations to find required and desired minimum storage fur different demands. To investigate the system behavior resulting from the above-mentioned operating policy, i.e., the rule curves, the simulation model was used. Results of the simulation model show that the results of the optimization model are indeed valid. After confirmation of the above mentioned rule curves by the simulation models, gate operation procedure was merged with the long term operation rules to determine the optimum reservoir operating policy. In the gate operation procedure, operating policy in downstream flood plain, i.e., determination of damaging and non-damaging discharges in flood plain, peak floods, which could be routed by reservoir, are determined. Also outflow hydrograph and variations of water surface levels for two known hydrographs are determined. To examine efficiency of the above-mentioned models and their ability in determining the optimum operation policy, Esteghlal reservoir in Iran was analyzed as a case study. A numerical model fur the solution of two-dimensional dam break problems using fractional step method is developed on unstructured grid. The model is based on second-order Weighted Averaged Flux(WAF) scheme with HLLC approximate Riemann solver. To control the nonphysical oscillations associated with second-order accuracy, TVD scheme with SUPERBEE limiter is used. The developed model is verified by comparing the computational solutions with analytic solutions in idealized test cases. Very good agreements have been achieved in the verifications.

  • PDF