하수처리수의 재이용을 위한 벼 재배시험 (Rice Cultivation with Reclaimed Wastewater Irrigation for Wastewater Reuse)

  • 강문성;박승우;김상민;성충현
    • 한국농공학회논문집
    • /
    • 제46권1호
    • /
    • pp.75-86
    • /
    • 2004
  • The objective of the research is to develop agricultural resue technologies of reclaiming the effluents from a municipal wastewater treatment plant and reusing for irrigated rice paddies. The Suwon wastewater treatment plant was selected for wastewater reuse tests. The control was the plots with groundwater irrigation (TR#1), the treatment (TR#2) using polluted stream water as it was, and three others using wastewater after treatment. Three levels of wastewater treatments were employed: the effluent from the wastewater treatment plant (TR#3), sand filtering after treatment plant(TR#4), and ultra-violet treatment after sand filtering (TR#5). The randomized block method was applied to wastewater application to paddy rice with five treatments and six replica. The effects of various wastewater treatment levels on water quality, paddy soil, crop growth, yields, and the health hazards were investigated. The primary results indicate that cultivating rice with reclaimed wastewater irrigation did not cause a problem to adverse effects on crop growth and yields. Overall, wastewater could be used as a practical alternative measure for reclaimed wastewater irrigation. However, long-term monitoring is recommended on the effects on soil chemical characteristics and its related health concerns.

정수 및 하수처리공정 중 침전지 부착조류 및 미생물 군집구조 해석 (Analysis of Attached Algae and Microbial Community Structure in Sedimentation Basin of Water and Wastewater Treatment Plant)

  • 임병란;안규홍;송경근;박유정;전대영
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.61-67
    • /
    • 2005
  • The objective of this study was to investigate community structure of attached algae and microbes in sedimentation basin of water and wastewater treatment plants by using respiratory quinone profile. There was an evident difference, in microbial community structure and attached algae species, between inclination plate settler and drainage canal in the sedimentation basin. The algae was composed of species in following order; Chlorophyceae>Bascillariophyceae>Cyanophyceae. The dominant quinone types of attached microorganisms in the wastewater treatment plant were plastoquinone (PQ)-9, vitamin(V)K-1 followed by UQ-8, but those for water treatment plant were VK-1, PQ-9 followed by UQ-8. These results suggests that nutrients, seasons and material of sedimentation basin have notable influence on composition of attached algae and microbial community structure in water and wastewater treatment plants.

농촌 지역에서 유입 유량이 소규모 하수처리장 처리 효율에 미치는 영향 (Effect of sewage flow on treatment efficiency of small scale wastewater treatment plant in rural community)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제18권3호
    • /
    • pp.267-274
    • /
    • 2016
  • 농촌 지역 하수도 보급은 하천, 호소 및 습지와 같은 수계 수질 보호를 위해서 반드시 필요하다. 또한 안정적인 소규모 하수처리장 운영을 위해서는 유입 유량과 농도의 변화가 큰 소규모 하수도 특성을 고려해야 한다. 본 연구에서는 봉화군 18개의 소규모 하수처리장 운전 결과를 통해 유입유량비 (유입 유량 / 설계 유량) 특성, 소규모 하수처리장 처리 효율에 미치는 영향과 적정 유입유량비 산정에 관한 연구를 수행하였다. 분석 결과 유입유량비는 여름철에 가장 높은 것으로 나타난 반면, 유입 하수 농도는 가을철과 겨울철에 높은 것으로 나타났다. 유입유량비가 증가할수록 처리 효율이 증가하는 경향을 보였으며, 영양염류 처리 효율이 유기물과 부유물질 처리 효율에 비해 민감한 영향을 받는 것으로 나타났다. 안정적인 소규모 하수처리장 처리 효율을 위해서는 유입유량비 0.8 이상을 유지해야 할 것으로 판단된다.

파일럿 플랜트 규모에서 일체형 침전부상공정 (SeDAF)의 설계인자 및 운전특성에 대한 실증적 평가 (Empirical evaluation for design parameters and operating characteristics of the integrated sedimentation and dissolved air flotation (SeDAF) process at the pilot-scale plant)

  • 장여주;정진홍;임현만;김원재
    • 상하수도학회지
    • /
    • 제35권1호
    • /
    • pp.1-14
    • /
    • 2021
  • Eutrophication and algal blooms can lead to increase of taste and odor compounds and health problems by cyanobacterial toxins. To cope with these eco-social issues, Ministry of Environment in Korea has been reinforcing the effluent standards of wastewater treatment facilities. As a result, various advanced phosphorus removal processes have been adopted in each wastewater treatment plant nation-widely. However, a lot of existing advanced wastewater treatment processes have been facing the problems of expensive cost in operation and excessive sludge production caused by high dosage of coagulant. In this study, the sedimentation and dissolved air flotation (SeDAF) process integrated with sedimentation and flotation has been developed for enhanced phosphorus removal in wastewater treatment facilities. Design and operating parameters of the SeDAF process with the capacity of 100 ㎥/d were determined, and a demonstration plant has been installed and operated at I wastewater treatment facility (located in Gyeonggi-do) for the verification of field applicability. Several empirical evaluations for the SeDAF process were performed at demonstration-plant scale, and the results showed clearly that T-P and turbidity values of treated water were to satisfy the highest effluent standards below 0.2 mg/L and 2.0 NTU stably for all of operation cases.

시설용량을 초과하는 폐수량의 유입확률 분석을 위한 극치분포모델의 적용에 관한 연구 (A study on the application of the extreme value distribution model for analysis of probability of exceeding the facility capacity)

  • 최성현;유순유;박태욱;박규홍
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.369-379
    • /
    • 2016
  • It was confirmed that the extreme value distribution model applies to probability of exceeding more than once a day monthly the facility capacities using data of daily maximum inflow rate for 7 wastewater treatment plant. The result of applying the extreme value model, A, D, E wastewater treatment plant has a problem compared to B, C, F, G wastewater treatment plant. but all the wastewater treatment plant has a problem except C, F wastewater treatment plant based 80% of facility capacity. In conclusion, if you make a standard in statistical aspects probability exceeding more than once a day monthly can be 'exceed day is less than a few times annually' or 'probability of exceeding more than once a day monthly is less than what percent'.

하수처리장 연계처리를 위한 가축분뇨 최적 처리공정 선정에 관한 연구 (Determination of Optimal Livestock Wastewater Treatment Process for Linked Treatment in Sewage Treatment Plant)

  • 김충곤;신현곤
    • 유기물자원화
    • /
    • 제20권3호
    • /
    • pp.52-59
    • /
    • 2012
  • 처리공정별 연계처리수질을 검토한 결과 생물학적처리만 거친 생물반응조 처리수의 경우 연계부하율이 $COD_{Mn}$의 경우 1.67%(설계수질 기준), 2.59%(운영수질 기준), T-P의 경우 3.69%(설계수질 기준), 7.67%(운영수질 기준)로 다소 높게 나타났으나 하수처리장 운영에 미치는 영향은 거의 없을 것으로 판단된다. 또한, 고도처리공정인 산화부상분리 처리수 및 생물여과 처리수의 경우 연계부하율은 1% 내외로 고도처리설비 설치 시 과대 설비설치의 우려가 있다. 따라서 S하수처리장의 경제성 및 안정적인 운영을 고려할 경우 생물학적처리인 생물반응조를 거친 처리수를 연계하는 것이 바람직할 것으로 판단된다.

에너지 자립형 MBR, A/O 공정의 효율 평가 (Efficiency evaluation of MBR, A/O processes utilizing self-sufficient energy)

  • 임세택;김진근
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.305-314
    • /
    • 2014
  • A pilot plant (Q=5 $m^3/d$) study was implemented for small and medium sized personal wastewater treatment plant effluent to evaluate MBR and A/O processes utilizing self-sufficient energy composed of wind and solar energy. The removal efficiencies of BOD, SS, turbidity and color were sufficient for legal water quality standards for gray water. However, those of nitrogen and phosphorus could not meet legal regulations which suggested that further removal of those contaminants were needed for reuse of the treated water. Self-sufficient energy rate was 100 % for the pilot plant due to excessive design capacity. In this research, wind and solar energy system was applied considering geological characteristics, which significantly improved energy self-sufficiency. Substantial improvement on energy self-sufficiency can be obtained by optimized investment and operation at a full scale wastewater treatment plant.

화학적 처리에 의한 1차 하수처리장의 처리효과 개선 -현장시험을 중심으로- (Chemically Enhanced Primary Treatment at D Wastewater Treatment Plant)

  • 곽종운;김승현;이찬원
    • 상하수도학회지
    • /
    • 제11권1호
    • /
    • pp.99-108
    • /
    • 1997
  • This study examined the feasbility of upgrading D waste water treatment plant which treats incoming wastewater by primary sedimentation only. By adding 20-40 ppm of Hi-PAX into the outlet of the aerated grit chamber, BOD and SS removal efficiences were improved from 29% and 36% to 53 % and 73%,respectively. However, chemically enhanced primary treatment failed to meet the upcoming wastewater quality standard(BOD and SS <20 mg/l) consistently. This was suspected to result from the deteriorated plant return stream. The wastewater treatment by chemical treatment should have increased the amount of the sludge to be removed as the sludge production was increased. Chemically enhanced primary treatment is anticipated to consistently produce effluent of the 1996 standards quality by adjusting the amount of the sludge to be removed. Besides BOD and SS removal, chemically enhanced primary treatment resulted in the improved T-P removal from 30% to 64-74%. However, such benefit was not observed in T-N removal. Improved T-P removal will be expected to help control water pollution in Masan bay.

  • PDF

섬유 형태에 따른 염색폐수 배출특성 연구 (Studies on the Effluent Characteristics of Dyeing Wastewater by Textile Classification)

  • 이수형;박정민;박상정;정제호
    • 한국물환경학회지
    • /
    • 제23권6호
    • /
    • pp.881-888
    • /
    • 2007
  • In order to investigate the characteristics of the non-biodegradable material, the $BOD_5/COD_{Cr}$ ratio was used. The average ratio of industrial complex's influent wastewater was 2.29~2.96, the effluent ratio was 4.29~19.0. The removal efficiency of $UV_{254}$ by physicochemical treatment was 22.8~94.7% and 5.3~77.2% by biological treatment, respectively. Of the wastewater removal efficiency for each of the items, the $BOD_5$ treatment efficiency was the greatest at 97.3% and the color & TN treatment efficiency was 40~70%. The study of the economical assessment showed that the complex as well as the individual companies spent 722~1,298 won for each ton of treated wastewater. All of the wastewater treatment facilities spent the most money on chemicals needed to treat the wastewater. The total cost for Nylon manufacturing wastewater treatment plant was the greatest while the total cost for cotton manufacturing wastewater treatment plant turned out to the lowest. As respects of removal efficiency and economocal assessment, Polyester A and Cotton manufacturing wastewater treatment plants were better effective than a dyeing industrial complex wastewater treatment plant.