• Title/Summary/Keyword: water addition ratio

Search Result 1,298, Processing Time 0.032 seconds

Fermentation Properties of Yulmoo Mulkimchi According to the Ratio of Water to Yulmoo (물비율을 달리한 열무 물김치의 발효특성)

  • 최성유;오지영;유정화;한영숙
    • Korean journal of food and cookery science
    • /
    • v.14 no.4
    • /
    • pp.327-332
    • /
    • 1998
  • In the fermentation of Yulmoo Mulkimchi, various ratios of Yulmoo to water (l/l.14, l/l.5, 1/2, l/2.75, 1/4) were prepared and fermented at 4$^{\circ}C$, 15$^{\circ}C$, 25$^{\circ}C$ for up to 10 days. According to the fermentation time, the pH, acidity, total vitamin C content and microbial growth in Mulkimchi samples were determined together with sensory evaluation. Fermentation temperature on water addition ratio didn't show any difference in pH and microbial growth of Mulkimchi. However, low ratio of water resulted in high acidity and vitamin C content in Mulkimchi. In terms of acid odor and acid taste, the least water addition (l/l.4) sample was significantly strong than those of other samples. The ratio of Yulmoo to water, l/2 showed the highest overall sensorial acceptability and followed by l/l.5, l/l.4, l/2.75 and 1/4 samples. It was found that the content of vitamin C and acid taste of Mulkimchi have correlation with its acceptability.

  • PDF

Water Absorption Ratio and Flexural Strenght of the Magnesium Oxide Light Weight Matrix According to the Powdery Modified Sulfur Addition Ratio (분말형 개질유황 첨가율에 따른 산화마그네슘 경량 경화체의 흡수율 및 휨강도 특성)

  • Yoo, Yong-Jin;Jeong, Byeong-Yeol;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.114-115
    • /
    • 2014
  • Recently, the construction structure repeats the brilliant development including the shper high rising, high functionalization, environmental friendliness, conversion to ubiquitous, and etc. upon with the construction industry development and it is continually soothed. Meanwhile, as to the construction structure of the modern society, the research for corresponding to the box-frame construction way where the response to the diversity of the life of the occupant is difficult is needed. Thus, the lightweight of the structure is the important factor in order to secure the functionality. Therefore, this research tries to study the water absorption ratio and flexural strenght of the magnesium oxide light weight matrix according to the powdery modified sulfur addition ratio.

  • PDF

A study on the evaluation for variation of revenue water ratio considering water supply area conditions and the development of proper cost estimation model of project for improvement of revenue water ratio (급수지역 여건을 고려한 유수율 변동 분석 및 적정 유수율 제고 사업비 산정 모델 개발)

  • Kiwon Kwon;Jinseok Hyung;Taehyeon Kim;Haekeum Park;Yoojin Oh;Jayong Koo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.409-423
    • /
    • 2023
  • In this study, we analyzed how the revenue water ratio(RWR) is affected by changes in conditions of the water supply area, such as the ratio of aging pipes, maintenance conditions, and revenue water. As a result of analyzing the impact of pipe aging and maintenance conditions on the RWR, it was confirmed that the RWR could be decreased if the pipe replacement project to improve the aging pipe ratio was not carried out and proper maintenance costs were not secured. It was also confirmed that an increase in the revenue water could be operated to facilitate the achievement of the project's target RWR. In contrast, a decrease in the revenue water due to a population reduction could affect the failure of the target RWR. In addition to analyzing the causes of variation in the RWR, the calculation of estimated project costs was considered by using leakage reduction instead of RWR from recent RWR improvement project cost data. From this analysis, it was reviewed whether the project costs planned to achieve the target RWR of the RWR improvement project in A city were appropriate. In conclusion, the RWR could be affected by variations in the ratio of aging pipes, maintenance conditions, and revenue water, and it was reasonable to consider not only the construction input but also the input related to RWR improvement, such as leakage reduction, when calculating the project cost.

A Study on the Improvements of Strengths of Water-Permeable Concrete (투수성 콘크리트의 강도개선에 관한 연구)

  • 은재기;이철웅;김완기;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.307-312
    • /
    • 1999
  • The purpose of this study is to ascertain the strength properties of water-permeable concrete with redispersible polymer powder, silica fume and polypropylene fibers. The water-permeable concrete using rediapersibel polymer powder with a water-cement ratio of 25%, polymer-cement ratios of 0 to 10%, silica fume contents of 0 to 10% and fiber contents of 0 to 1.5% are prepared, and tested for flexural strength, compressive strength and water permeability. From the test results, improvements in the strength properties of the water-permeable concrete due to the addition of the redispersible polymer powder, silica fume and fibers are discussed. It is concluded from the test results that the superior flexural and compressive strengths of water-permeable concretes are obtained at a propylene fiber content of 1.0% with a void filling ratio of 50%. And, the water-permeable concrete having a flexural strength of 15.6~28.4kgf/$\textrm{cm}^2$, a compressive strength of 63.5~120.6kgf/$\textrm{cm}^2$, and a coefficient of permeability of 1.14~1.70cm/s at a void filling ratio of 30% can be prepared. Also water-permeable concrete having a flexural strength of 35.6~57.9kgf/$\textrm{cm}^2$, a compressive strength of 164.0~290.0kgf/$\textrm{cm}^2$, and a coefficient of permeability of 0.19~1.04cm/s at a void filling ratio of 50% can be prepared in the consideration of the mix proprotioning factors.

  • PDF

Analysis of Operational Plan and Economical Validity in Aquacultural for Contingency Red Tide (적조 대응 육상양식장 운영방안 및 경제적 타당성 분석)

  • Lee, Kwang-Nam
    • The Journal of Fisheries Business Administration
    • /
    • v.47 no.3
    • /
    • pp.35-52
    • /
    • 2016
  • This paper analyzed economic feasibility of aquacultural construction which of large-scale. The results of the economic analysis, cage cultural and water recycling cultural by post-water treatment were analyzed that NPV is 2,083,685 thousand won and -14,105,896 thousand won and B/C ratio is 0.590 and 0.855, respectively. These were shown economic infeasibility. But, running water culture by pre-water treatment(small scale) and running water culture by pre-water treatment(large scale) were analyzed that the one is 5,555,747 thousand won and 15,048,589 thousand won and the other is 1,154 and 1,1221, respectively. these were shown economic feasibility. In addition, measurement of B/C ratio through a sensitivity analysis on running water cultural by pre-water treatment(small scale) and running water cultural by pre-water treatment(large scale) is economic feasibility in all cases. However, these were analyzed when the selling price was falling to 20 percent, it has shown economic infeasibility and when the selling price rises to 20 percent, water recycling culture by post-water treatment has economic feasibility. The significance of the study analyzed a sensibility as well as economic feasibility by methods and scales. It is expected that used as basic materials when constructing and operating of land aquaculture in order to minimize the damage from natural disasters.

Development of Biological Filtration Process for Effective Nitrogen Removal and its Control strategies in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거를 위한 운전제어법 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.230-237
    • /
    • 2006
  • The operational parameters and control strategies of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. Methanol addition was controlled based on the COD/N ratio or McCarty's equation. Constant COD/N ratio control results in excess addition under large diurnal fluctuation of $NOx^--N$, and McCarty's equation can be used to add appropriate amount of methanol. Control of methanol addition by on-line nitrate measurement, control of aeration by on-line DO measurement, and control of backwashing by head loss measurement are successfully operated. These results proved that this process prove the easy-maintenance and cost-effectively treatment is attainable.

Effect of polyolefin fibers on the permeability of cement-based composites

  • Hsu, Hui-Mi;Lin, Wei-Ting;Cheng, An
    • Computers and Concrete
    • /
    • v.9 no.6
    • /
    • pp.457-467
    • /
    • 2012
  • This study evaluates the permeability of cement-based composites, which are a mix of polyolefin fibers and silica fume. Test results indicate that permeability increases as the water/cementitious ratio increases. Silica fume in cement-based composites produced hydrated calcium silicate and filled the pores. However, permeability decreased as the addition of silica fume increased. Specimens containing polyolefin fibers also provided higher permeability resistance. The polyolefin fiber length did not have a significant effect on permeability. The decrease in the permeability is mainly due to the addition of silica fume and lower water/cementitious ratio. Addition of fibers marginally decreases the permeability. Incorporating polyolefin fiber and silica fume in composites achieved more significant decreases in permeability. The correlated test results reveal the interrelationship between them.

Design of Oral Patches for the Treatment of Aphthous Stomatitis : Drug Layer (아프타성 구내염 치료용 구강 패취의 설계 : 약물층)

  • Lee, Kyu-Hyun;Park, Eun-Seok;Chi, Sang-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.4
    • /
    • pp.339-345
    • /
    • 1995
  • For the effective treatment of aphthous stomatitis, the matrix type mucoadhesive patches containing triamcinolone acetonide have been formulated. The drug layer was obtained by drying the polymer gel which was prepared with carbomer 934P, ammoniomethacrylate copolymer, titanium dioxide and polyethylene glycol 400. The effects of the content of additives on physical characteristics of the polymer gel and the drug layer were evaluated. The addition of carbomer increased the yield point and the zero-shear viscosity of polymer gel as well as the thickness, the water absorption ratio, the adhesive time and $T_{50%}$ of drug layer. The adhesive time and the water absorption ratio of drug layer were also improved by the addition of ammoniomethacrylate copolymer, but the addition of titanium dioxide had decreased the zero-shear viscosity of polymer gel and the adhesive time of drug layer.

  • PDF

Optimization of Cholesterol Removal by Crosslinked ${\beta}$-Cyclodextrin in Egg Yolk

  • Jung, Tae-Hee;Park, Heung-Sik;Kwak, Hae-Soo
    • Food Science and Biotechnology
    • /
    • v.14 no.6
    • /
    • pp.793-797
    • /
    • 2005
  • Optimum conditions for cholesterol removal in egg yolk were evaluated based on ratio of egg yolk-to-water, crosslinked ${\beta}$-cyclodextrin (${\beta}$-CD) concentration, and mixing temperature, time, and speed by adding crosslinked ${\beta}$-CD treated with adipic acid. Cholesterol removal in egg yolk-water mixture increased with increasing ${\beta}$-CD level (10-25%). About 95% was removed by 25% ${\beta}$-CD at 1:1 ratio of egg yolk-to-water and 800 rpm mixing at $40^{\circ}C$ for 30 min. In recycling study, removal rates were measured using ten times recycled crosslinked ${\beta}$-CD in egg yolk, and 85% cholesterol removal was observed with eight times reuse. These results indicated that over 90% cholesterol was removed at 1:1 ratio of egg yolk-to-water, 20% crosslinked ${\beta}$-CD addition, and 30 min mixing with 600 rpm at $40^{\circ}C$.

Experimental investigation of the effect of the addition of Aerosil 200 nanoparticles on the water absorption of polymer concrete

  • A.M. Fattahi;Babak Safaei;Elham Moaddab;Zahra Pezeshki
    • Advances in nano research
    • /
    • v.14 no.1
    • /
    • pp.81-92
    • /
    • 2023
  • In this work, the effect of the addition of Aerosil 200, an insulating resin applied in many industries, on the water absorption of cement plast mixture has been experimentally evaluated. First, the preparation stages of cement plast mixture was evaluated based on corresponding standards and then, the effect of the addition of Aerosil 200 nanoparticles (NPs) to cement plast mixtures with sand weight percentage range of 0-0.1% on the variation of water absorption properties was evaluated based on National Standard Institution of Iran 20185 for Concrete Flooring Blocks - Requirements and Test Procedures. Based on the obtained results, it could be found that excessive addition of NPs did not affect the physical properties of the final product. Water absorption percentage was increased in the weight percentage of cement. By the increase of the amount of Aerosil 200 NPs in the prepared cement plast mixture, the percentage of water absorption in weight percentage of sand was decreased. Cement plast with NPs presented significantly lower water absorption than that without NPs.