• 제목/요약/키워드: washing cycle

검색결과 74건 처리시간 0.026초

국내 소비재 기업의 지속 가능한 플라스틱 경영 전략 평가를 위한 지표 개발 (Evaluation of Sustainable Plastic Management Strategy of Korean Consumer Goods Companies)

  • 한수호;권성구;박준희;이정기;이재혁;성용준;황성연;옥용식
    • 한국환경과학회지
    • /
    • 제32권11호
    • /
    • pp.745-756
    • /
    • 2023
  • Growing stringent global regulations in Korea poses a threat to corporate sustainability. Companies must respond strategically to navigate these regulations and avoid greenwashing. Objective of this research was to analyze how Korean companies are responding to the global trend of reducing plastic use and propose improved management strategies. Seven indicators were developed to assess companies' post-plastic strategies and applied to analyze the sustainability reports of Amore Pacific and LG Household & HealthCare. These indicators included, 1) disclosure of plastic raw materials used by weight or volume, 2) disclosure of recycled plastic raw materials used by weight or volume, 3) disclosure of waste recycling, reuse amounts, and disposal using waste treatment method 4) strategies to reduce environmental impact of plastics, 5) plastic packaging, reduce, recycle, reuse, and composting (in the real environment), 6) plastic management roadmap for the circular economy, and 7) education for sustainable plastic management. Based on the review of considered companies, we propose in-listed sustainable plastics management strategies: disclosing the ratio of plastic raw materials and recycled raw materials for all products, considering recycling rate throughout the product value chain, and not only for the production phase, reviewing carbon dioxide emissions based on life cycle assessment rather than reducing plastic consumption, studying the biodegradability of biodegradable plastics in natural environment such as soil, considering the consumer's perspective.

Balancing assembly line in an electronics company

  • 박경철;강석훈;박성수;김완희
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 1993년도 추계학술대회발표논문집; 서강대학교, 서울; 25 Sep. 1993
    • /
    • pp.12-19
    • /
    • 1993
  • In general, the line balancing problem is defined as of finding an assignment of the given jobs to the workstations under the precedence constraints given to the set of jobs. Usually, the objective is either minimizing the cycle time under the given number of workstations or minimizing the number of workstations under the given cycle time. In this paper, we present a new type of an assembly line balancing problem which occurs in an electronics company manufacturing home appliances. The main difference of the problem compared to the general line balancing problem lies in the structure of the precedence given to the set of jobs. In the problem, the set of jobs is partitioned into two disjoint subjects. One is called the set of fixed jobs and the other, the set of floating jobs. The fixed jobs should be processed in the linear order and some pair of the jobs should not be assigned to the same workstations. Whereas, to each floating job, a set of ranges is given. The range is given in terms of two fixed jobs and it means that the floating job can be processed after the first job is processed and before the second job is processed. There can be more than one range associated to a floating job. We present a procedure to find an approximate solution to the problem. The procedure consists of two major parts. One is to find the assignment of the floating jobs under the given (feasible) assignment of the fixed jobs. The problem can be viewed as a constrained bin packing problem. The other is to find the assignment of the whole jobs under the given linear precedence on the set of the floating jobs. First problem is NP-hard and we devise a heuristic procedure to the problem based on the transportation problem and matching problem. The second problem can be solved in polynomial time by the shortest path method. The algorithm works in iterative manner. One step is composed of two phases. In the first phase, we solve the constrained bin packing problem. In the second phase, the shortest path problem is solved using the phase 1 result. The result of the phase 2 is used as an input to the phase 1 problem at the next step. We test the proposed algorithm on the set of real data found in the washing machine assembly line.

  • PDF

전기분해수 처리에 의한 딸기의 살균 효과 및 저장 중 품질변화 (Disinfection Effects of Electrolyzed Water on Strawberry and Quality Changes during Storage)

  • 정진웅;김종훈;권기현;박기재
    • 한국식품저장유통학회지
    • /
    • 제13권3호
    • /
    • pp.316-321
    • /
    • 2006
  • 전해 방식에 따라 제조된 전기분해수로 세정처리한 딸기의 살균효과 및 저장중 품질변화를 살펴본 결과, 전기분해수에 의한 딸기의 미생물학적 살균효과는 침지수량은 중량 대비 10배수, 침지시간은 20분 처리시 초기균수에 대하여 2 log cycle 정도 감소하며 저장중 균증식 속도도 다소 느리게 나타났다. 폐기율은 $5^{\circ}C$ 저장시 EW-2 처리구에서 저장 5일째까지 10%수준을 보여 무처리 및 염소수 처리에 비해 낮은 폐기율을 보여주었고, 조직감도 $5^{\circ}C$ 저장 전기분해수 처리구에서는 저장 3일까지는 조직감 변화가 거의 없다가 그 이후 오히려 증가하는 경향을 나타내었다. 딸기의 표면색도 변화는 저장기간이 경과할 수록 무처리구와 CW 처리구는 전반적으로 L값이 증가하는 경향을 보인 반면에 전기분해수 처리구는 감소하는 경향을 보여 주었고, 저장기간별 색차(${\Delta}E$)값은 저장 3일까지는 무처리구가 가장 적은 변화를 나타내었다. 전기분해수 처리에 의한 초기 잔류염소량은 $0.04{\sim}0.06ppm$수준이며 저장 1-3일 경과 후에는 모든 처리구에서 $0.02{\sim}0.03ppm$ 수준으로 잔류염소량이 거의 동일하게 나타났다. 저장중 관능적 특성은 전기분해수 처리구(EW-1 및 EW-2)가 무처리 및 CW 처리구에 비해 높게 나타났다.

가정용 전력 모니터링 시스템 및 장치식별 알고리즘 개발 (Development of Home Electrical Power Monitoring System and Device Identification Algorithm)

  • 박성욱;서진수;왕보현
    • 한국지능시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.407-413
    • /
    • 2011
  • 본 연구에서는 가정용 전력 모니터링 시스템을 구현하고 실험가구에 적용하여 평가하였으며, 평가과정에서 확보한 기기별 전력 사용 패턴 정보를 이용하여 자동 기기 식별 알고리즘을 개발하였다. 실험가구에 적용해본 결과, 기기별 전력사용 정보와 월별 예상 사용량 정보가 전력 소비 절감에 도움이 된다는 응답을 얻을 수 있었다. 그리고 시스템을 보다 편리하게 사용하기 위해서는 설치의 편의성과 UI를 개선해야한다는 응답을 얻었다. 본 연구에서는 UI 개선을 위하여 일반냉장고, TV, 전기밥솥, 김치냉장고, 세탁기를 자동으로 식별하는 알고리즘을 구현하였다. 자동 장치 식별 알고리즘은 전력 모니터링 과정에서 수집한 전력 소비 패턴을 관찰하여 Zero-Crossing Rate(ZC), Variation of On State(VO), Slope of On State(SO), Duty Cycle(DC) 등 4가지 특징을 규정하여 이용하였으며, 특징을 적용하는 시간 구간은 기기가 동작하는 시간이 25% 이상이 되는 2시간 길이의 구간을 이용하였다. 제안된 알고리즘은 테스트 set에 동일한 기기를 포함하는 경우 82.1%의 성능을 얻을 수 있었다.

반복세탁이 산림작업복 하의의 수축률에 미치는 영향 (Effect of Repeated Laundry on Shrinkage Rate of Chainsaw Protective Pants)

  • 정응진;박수규;한상균;차두송
    • 한국산림과학회지
    • /
    • 제108권3호
    • /
    • pp.341-348
    • /
    • 2019
  • 본 연구는 체인톱에 의한 산림작업 안전사고 저감을 위하여 산림작업복 하의 4개 품목을 대상으로 작업복 17개 부위의 수축률을 측정하였다. 추가적으로 품목 및 반복세탁횟수에 따른 산림작업복의 하의의 적합성을 검토하고 반복세탁을 통한 산림작업복의 사용권장 기간을 제시하였다. 산림작업복 하의 4개 품목의 반복세탁에 따른 수축률 결과, 대부분의 품목이 세탁 20회에서 수축률 기준인 6%가 초과되는 부위가 1개소씩 발생하였으며, 가로방향 측정부위가 세로방향 측정부위보다 더 크게 수축되었다. 또한 산림작업복 하의 수축률의 영향을 미치는 인자로는 반복세탁횟수(p<0.05)와 측정부위(p<0.05)로 나타났으며, 측정부위별 수축율에 있어서 총 5개 부위(a, b, g, j, n)가 반복세탁횟수와 유의성이 있는 것으로 (p<0.05) 나타났다. 따라서, 산림작업복 하의의 사용 권장기간은 10개월 정도로 판단되며, 추후 반복세탁횟수와 측정부위와의 관계를 상세 분석하여 산림작업복 하의의 내구성에 대해 검토할 예정이다.

Integrated Rotary Genetic Analysis Microsystem for Influenza A Virus Detection

  • Jung, Jae Hwan;Park, Byung Hyun;Choi, Seok Jin;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.88-89
    • /
    • 2013
  • A variety of influenza A viruses from animal hosts are continuously prevalent throughout the world which cause human epidemics resulting millions of human infections and enormous industrial and economic damages. Thus, early diagnosis of such pathogen is of paramount importance for biomedical examination and public healthcare screening. To approach this issue, here we propose a fully integrated Rotary genetic analysis system, called Rotary Genetic Analyzer, for on-site detection of influenza A viruses with high speed. The Rotary Genetic Analyzer is made up of four parts including a disposable microchip, a servo motor for precise and high rate spinning of the chip, thermal blocks for temperature control, and a miniaturized optical fluorescence detector as shown Fig. 1. A thermal block made from duralumin is integrated with a film heater at the bottom and a resistance temperature detector (RTD) in the middle. For the efficient performance of RT-PCR, three thermal blocks are placed on the Rotary stage and the temperature of each block is corresponded to the thermal cycling, namely $95^{\circ}C$ (denature), $58^{\circ}C$ (annealing), and $72^{\circ}C$ (extension). Rotary RT-PCR was performed to amplify the target gene which was monitored by an optical fluorescent detector above the extension block. A disposable microdevice (10 cm diameter) consists of a solid-phase extraction based sample pretreatment unit, bead chamber, and 4 ${\mu}L$ of the PCR chamber as shown Fig. 2. The microchip is fabricated using a patterned polycarbonate (PC) sheet with 1 mm thickness and a PC film with 130 ${\mu}m$ thickness, which layers are thermally bonded at $138^{\circ}C$ using acetone vapour. Silicatreated microglass beads with 150~212 ${\mu}L$ diameter are introduced into the sample pretreatment chambers and held in place by weir structure for construction of solid-phase extraction system. Fig. 3 shows strobed images of sequential loading of three samples. Three samples were loaded into the reservoir simultaneously (Fig. 3A), then the influenza A H3N2 viral RNA sample was loaded at 5000 RPM for 10 sec (Fig. 3B). Washing buffer was followed at 5000 RPM for 5 min (Fig. 3C), and angular frequency was decreased to 100 RPM for siphon priming of PCR cocktail to the channel as shown in Figure 3D. Finally the PCR cocktail was loaded to the bead chamber at 2000 RPM for 10 sec, and then RPM was increased up to 5000 RPM for 1 min to obtain the as much as PCR cocktail containing the RNA template (Fig. 3E). In this system, the wastes from RNA samples and washing buffer were transported to the waste chamber, which is fully filled to the chamber with precise optimization. Then, the PCR cocktail was able to transport to the PCR chamber. Fig. 3F shows the final image of the sample pretreatment. PCR cocktail containing RNA template is successfully isolated from waste. To detect the influenza A H3N2 virus, the purified RNA with PCR cocktail in the PCR chamber was amplified by using performed the RNA capture on the proposed microdevice. The fluorescence images were described in Figure 4A at the 0, 40 cycles. The fluorescence signal (40 cycle) was drastically increased confirming the influenza A H3N2 virus. The real-time profiles were successfully obtained using the optical fluorescence detector as shown in Figure 4B. The Rotary PCR and off-chip PCR were compared with same amount of influenza A H3N2 virus. The Ct value of Rotary PCR was smaller than the off-chip PCR without contamination. The whole process of the sample pretreatment and RT-PCR could be accomplished in 30 min on the fully integrated Rotary Genetic Analyzer system. We have demonstrated a fully integrated and portable Rotary Genetic Analyzer for detection of the gene expression of influenza A virus, which has 'Sample-in-answer-out' capability including sample pretreatment, rotary amplification, and optical detection. Target gene amplification was real-time monitored using the integrated Rotary Genetic Analyzer system.

  • PDF

드럼세탁기용 커플링 부품 다이캐스팅 금형개발 (Development of Mold for Coupling Parts for Drum Washing Machine)

  • 박종남;노승희;이동길
    • 한국산학기술학회논문지
    • /
    • 제21권6호
    • /
    • pp.482-489
    • /
    • 2020
  • 본 연구의 목적은 소비자 및 현장의 니즈에 부합하면서 다이캐스팅으로 생산할 수 있는 커플링 부품을 개발하고자 하였으며, 유동 및 응고해석을 기반으로 다이캐스팅 금형 설계, 제작, 및 사출조건 최적화 도출을 실시하였고 사출된 제품의 측정 및 평가를 수행하였다. 유동해석을 통하여 캐비티 내부가 100 % 충진되기 위한 적정한 사출조건은 용탕의 온도 670 ℃, 사출속도 1.164 m/s, 충진압력 6.324~18.77 MPa로 분석되었다. 또한, 응고율이 69.47 %일 때 4개의 캐비티 모두에서 100 %에 근접하는 응고가 발생됨을 알 수 있었으며, 이를 기초로 시사출 조건설정 등에 응용하였으며 그 결과 사이클 타임은 약 6.5초로 도출되었다. 다이캐스팅으로 시사출된 제품의 표면 및 내부의 품질 검사를 수행한 결과 성형불량 및 기공 등의 결함은 전혀 발견되지 않았으며, 주요 개소의 치수를 측정한 결과 모든 항목에서 허용하는 공차 이내의 값을 보였다. 또한, 게이트로부터 약 45 mm 이격된 곳의 평균 경도값은 97.7(Hv)로 나타나는 등 전체적으로 양호한 치수 및 품질의 부품을 제작할 수 있었다.

Quantitative PCR for Etiologic Diagnosis of Methicillin-Resistant Staphylococcus aureus Pneumonia in Intensive Care Unit

  • Kwon, Sun-Jung;Jeon, Tae-Hyeon;Seo, Dong-Wook;Na, Moon-Joon;Choi, Eu-Gene;Son, Ji-Woong;Yoo, Eun-Hyung;Park, Chang-Gyo;Lee, Hoi-Young;Kim, Ju-Ock;Kim, Sun-Young;Kang, Jae-Ku
    • Tuberculosis and Respiratory Diseases
    • /
    • 제72권3호
    • /
    • pp.293-301
    • /
    • 2012
  • Background: Ventilator-associated pneumonia (VAP) requires prompt and appropriate treatment. Since methicillin-resistant Staphylococcus aureus (MRSA) is a frequent pathogen in VAP, rapid identification of it, is pivotal. Our aim was to evaluate the utility of quantitative polymerase chain reaction (qPCR) as a useful method for etiologic diagnoses of MRSA pneumonia. Methods: We performed qPCR for mecA, S. aureus-specific femA-SA, and S. epidermidis-specific femA-SE genes from bronchoalveolar lavage or bronchial washing samples obtained from clinically-suspected VAP. Molecular identification of MRSA was based on the presence of the mecA and femA-SA gene, with the absence of the femA-SE gene. To compensate for the experimental and clinical conditions, we spiked an internal control in the course of DNA extraction. We estimated number of colony-forming units per mL (CFU/mL) of MRSA samples through a standard curve of a serially-diluted reference MRSA strain. We compared the threshold cycle (Ct) value with the microbiologic results of MRSA. Results: We obtained the mecA gene standard curve, which showed the detection limit of the mecA gene to be 100 fg, which corresponds to a copy number of 30. We chose cut-off Ct values of 27.94 (equivalent to $1{\times}10^4$ CFU/mL) and 21.78 (equivalent to $1{\times}10^5$ CFU/mL). The sensitivity and specificity of our assay were 88.9% and 88.9% respectively, when compared with quantitative cultures. Conclusion: Our results were valuable for diagnosing and identifying pathogens involved in VAP. We believe our modified qPCR is an appropriate tool for the rapid diagnosis of clinical pathogens regarding patients in the intensive care unit.

고염/고방사성 폐액 내 Cs 제거를 위한 복합 흡착제 합성 및 특성 연구 (Study of Composite Adsorbent Synthesis and Characterization for the Removal of Cs in the High-salt and High-radioactive Wastewater)

  • 김지민;이근영;김광욱;이일희;정동용;문제권;현재혁
    • 방사성폐기물학회지
    • /
    • 제15권1호
    • /
    • pp.1-14
    • /
    • 2017
  • 본 연구에서는 고염/고방사성 폐액 내 함유된 주요 고방사성핵종인 Cs 제거를 목적으로 고효율의 복합 흡착제(potassium cobalt ferrocyanide (PCFC)-loaded chabazite (CHA)) 합성 및 이의 적용성을 평가하였다. 복합 흡착제는 Cs을 비롯한 다른 입자를 수용할 수 있는 CHA를 지지체로 선정하였으며, $CoCl_2$$K_4Fe(CN)_6$ 용액의 단계적인 함침/침전을 통해 PCFC를 CHA 세공 내에 고정화함으로써 합성하였다. 복합 흡착제의 합성 시 평균 입자크기가 $10{\mu}m$ 이상의 CHA를 지지체로 사용할 경우, PCFC 입자는 안정적인 형태로 고정화되었다. 또한, 합성 시 복합 흡착제의 정제를 증가시키는 세척 방법을 최적화함으로써, 복합 흡착제의 물리적 안정성이 향상되었다. 최적의 합성법을 통해 얻은 복합 흡착제에 의한 Cs 흡착 시, 담수(무염조건) 및 해수(고염 조건)에서 모두 빠른 흡착 속도를 보였으며, 염 농도와 무관하게 비교적 높은 분배계수 값($10^4mL{\cdot}g^{-1}$ 이상)을 나타내었다. 그러므로, 본 연구에서 합성한 복합 흡착제는 CHA 및 PCFC가 각각 가지고 있는 물리적 안정성과 Cs에 높은 선택성 등을 고려하여 촤적화한 소재이며, 고염/고방사성폐액에 함유되어 있는 Cs을 고효율로 신속하게 제거할 수 있음을 알 수 있다.

아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교 (Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition)

  • 박미정;김사현;구보경;김소라
    • 한국안광학회지
    • /
    • 제18권2호
    • /
    • pp.107-115
    • /
    • 2013
  • 목적: 본 연구에서는 눈 화장품인 아이라이너에 노출시킨 소프트 콘택트렌즈의 파라미터가 어떻게 변하는가를 알아보고, 세척방법을 달리하여 세척하였을 때의 세척효과와 렌즈 파라미터의 회복정도를 비교하고자 하였다. 방법: 서로 다른 재질로 제조된 3종류의 소프트 콘택트렌즈에 각각 1시간, 4시간 및 6시간 동안 아이라이너를 침착시킨 후 안경용 초음파 세척 및 손 세척을 시행하였으며, 세척 전후 렌즈의 가시광선 투과도, 직경 및 표면의 변화를 비교하였다. 결과: 소프트 콘택트렌즈의 가시광선 투과도는 아이라이너의 침착시간이 길어질수록 감소하였다. 렌즈의 표면을 관찰한 결과 아이라이너의 침착 양상은 렌즈재질의 물성에 따라 다르게 나타나 narafilcon A 재질 렌즈에서 가장 침착이 큼을 알 수 있었다. 렌즈 직경은 hilafilcon B 및 etafilcon A 재질 렌즈는 감소하였으나, narafilcon A재질 렌즈는 증가하는 것으로 나타났다. 이러한 아이라이너의 침착은 안경용 초음파 세척기를 이용한 세척보다는 다목적 용액을 이용한 손 세척 시 세척효율이 우수한 것으로 나타났으나 렌즈의 직경이나 가시광선 투과도, 렌즈표면 등 렌즈 파라미터가 원래 상태로 회복되는 데에는 한계가 있었다. 결론: 이상의 결과로 소프트렌즈를 착용한 상태에서 눈 화장 하는 것을 최소화하는 것이 옳으며, 반복적으로 눈 화장을 할 때에는 렌즈 파라미터의 변화를 고려한 착용시간의 단축이나 빠른 렌즈의 교체주기가 필요하다고 사료된다.