• Title/Summary/Keyword: wash-off

Search Result 64, Processing Time 0.024 seconds

Determination of Design Capacity for NPS Pollutant Treatment Facilities by Long-term Simulation in Urban Areas (장기모의를 통한 도시유역 비점오염원 처리장치 용량 산정)

  • Joo, Jingul;Yoo, Doguen;Kim, Joonghoon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.841-847
    • /
    • 2011
  • In this study, a method to determine the design capacities of nonpoint source (NPS) pollutant treatment facilities in urban areas was suggested. A facility capacity to treat 80 percent of total SS discharge was estimated by 2-year rainfall - runoff - build-up and wash-off simulation at Goonja drainage district in Seoul. For wash-off simulation, four wash-off models (EMC, RC, EXP, and Joo model) were used. As the results, 80 percent of total SS discharge could be treated with only 7.7~31.4% facility capacity of peak flow. The suggested method and results will provide a guideline to determine design capacities of NPS pollutant treatment facility in urban areas.

환망 초지기의 뱃 운용이 종이의 품질에 미치는 영향

  • Park, Yong-Seong;Jeon, Yang;Seo, Yeong-Beom
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.04a
    • /
    • pp.55-55
    • /
    • 2000
  • Cylinder machine usually gives more fiber orientation than fourdrinier and has limitation in machine speed because of fiber wash-off caused by centrifugal force in case of adding machine speed. This study aimed at improvement of paper formation and higher productivity by setting up an apron in vat inlet and by adjustment of mould water head. As results, there were improvement of formation and increase of machine speed, which ultimately improve productivity. Setting up an apron successfully decreased fiber wash-off. Fiber orientation and two-sideness of ash distribution became less severe. These results could lead to better dimension stabilities in the CD through mitigation of fiber orientation and also could result in less curl from two-sideness of paper. The proper adjustment of water head inside the cylinder mould proved to be important factor not only in paper formation but also in decreasing paper two-sideness.

  • PDF

Effect of Vat Control in Cylinder Machine on Physical Properties of Paper (환망 초지기의 배트 운용이 종이의 품질에 미치는 영향)

  • Park, Yong-Sung;Jeon, Yang;Seo, Yung Bum
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.2
    • /
    • pp.51-57
    • /
    • 2000
  • Cylinder machine usually gives more fiber orientation than fourdrinier and has limitation in machine speed because of fiber wash-off caused by centrifugal force when machine speed increases. This study aimed for the improvement of paper formation and productivity by setting an apron in vat inlet and by adjusting mould water head. Improvement of formation and increase of machine speed were achieved, which ultimately improve productivity. Installing an apron successfully decreased fiber wash-off. Fiber orientation and two-sideness of ash distribution became less severe. The proper adjustment of water head inside the cylinder mould proved to be an important factor not only in paper formation but also in decreasing paper two-sideness.

  • PDF

Characteristics of Road Runoff depending on the Rainfall Intensity (강우강도에 따른 노면유출수의 유출 특성)

  • Kim, Seog-Ku;Kim, Young-Im;Yun, Sang-Leen;Lee, Yong-Jae;Kim, Ree-Ho;Kim, Jong-Oh
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.494-499
    • /
    • 2004
  • Growth in population and urbanization has progressively increased the loadings of pollutants from non-point sources as well as point sources. Therefore, it is necessary to manage both point and non-point sources contaminations for protecting water environment and improving water quality. This study investigated the characteristics of pollutant release over a wide range of rainfall intensities as a requisite to control road runoff that accounts for the largest portion of non-point source contamination in urban areas. Samples of runoff rainwater collected from real road surfaces were analyzed for physicochemical parameters such as pH, suspended solids, and heavy metals. A experimental model road ($30cm{\times}30cm$) was also used to evaluate wash-off properties of pollutants deposited on the surface as functions of time and rainfall intensity. Analysis of runoff samples on rain events showed that the pollutant wash-off patterns for heavy metal and suspended solids were similar. This implies that the particles in rainwater adsorb heavy metals. Experiments using the model road made of impervious asphalt demonstrate a strong first flush phenomenon. At high rainfall intensity, approximately 80% of total pollutants were released within 15 min. The pollutant wash-off rates rapidly increase from 9 mm/hr to 12 mm/hr of rainfall intensity and decrease over 12 mm/hr of rainfall intensity.

Reuses Of Wash Water Effluents Of The Ion-Exchanger Units Of Water Demineralization Plant For Economic And Environmental Benefits

  • Miah, Raisuddin
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.799-806
    • /
    • 1995
  • In industrial field, a large volume of regenerants (acid and caustic soda) and their washing effluents are regularly disposed off from the water demineralization plant during regeneration of the ion-exchanger units. Of these waste effluents, a part of the wash water discharged from the single bed Anion and Mixed Bed units can be utilized at a certain stage of their washing cycles when its conductivity is fallen down and becomes considerably less than that of the input raw water. The main aim of this specific waste effluent utilization is to dilute the TDS concentration of the input raw water (fed into the single bed ion-exchanger units) by blending. The achievement is the increase of the longevity of the production cycles of the I.E. units along with the improvement of the production quality and decrease of the regeneration frequencies. As a result, regenerant consumption would be saved because of the reduction of ionic load in feed water which will ultimately reduce the water purification cost. At the same time, the environment pollution will also be protected to a considerable extent. This operational measure is quite effective and useful specially where high TDS water is demineralized only by single bed ion-exchangers. In such case, the water treatment plant is very often found to suffer from both production quality and quantity in addition to carrying out of random and restless regenerations. Proper reuses of the aforesaid wash water effluents of the Anion and MB units excellently minimizes the difficulties experienced in practice. This paper contains the utilities and techniques of reuses of the different kinds of waste effluents of the industrial water treatment plant in addition to the specific reuses of the post-regeneration wash waters of the Anion and MB ion-exchanger units.

  • PDF

Aerosol Deposition and Behavior on Leaves in Cool-temperate Deciduous Forests. Part 1: A Preliminary Study of the Effect of Fog Deposition on Behavior of Particles Deposited on the Leaf Surfaces by Microscopic Observation and Leaf-washing Technique

  • Watanabe, Yoko;Yamaguchi, Takashi;Katata, Genki;Noguchi, Izumi
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • To establish the method for investigating the behavior of aerosol particles deposited on the leaf surface against fog water under natural conditions, scanning electron microscopy with energy-dispersive X-ray (SEM-EDX) analysis and wash water analysis by ion chromatography after the washing treatment were performed using leaves of white birch collected from low part of the tree crown and the top of the tree in Sapporo City, Hokkaido, northern Japan. Each of collected leaves was divided into two parts according to the treatment performed: leaf surface (adaxial side) was 1) untreated, and 2) washed with deionized water with a pipette. In untreated samples, many particles of various shapes, including soil particles and organic debris, were deposited on the surface. Particles containing S were found on the surface of samples collected from only low part of the tree crown. After the washing treatment, SEM-EDX analysis revealed that soil particles and particles containing S had been washed off with water, although some particles such as soil particles and organic debris still remained on the leaf surface. The major anion such as $SO{_4}^{2-}$ was detected in wash water of all samples, although the peak of S in X-ray spectra was not detected from samples collected at top of the tree. The combination of SEM-EDX analysis with wash water analysis indicated that $SO{_4}^{2-}$ was deposited on the leaf surface in dissolved state and/or in state of submicron particles. These results suggested that fog water could remove soil particles and particles containing S and $SO{_4}^{2-}$ from the leaf surfaces, but not all particles. There was no difference in sampling position in the tree crown. Our study suggested that combination with SEM-EDX analysis and wash water analysis would be effective for investigation of the behavior of particles on the leaf surface against fog water.

Characteristics of Non-point Pollutant from Highway Toll Gate Landuse (고속도로 영업소지역에서의 비점오염물질 유출특성)

  • Lee, Eun-Ju;Son, Hyun-Geun;Kang, Hee-Man;Kim, Lee-Hyung
    • International Journal of Highway Engineering
    • /
    • v.9 no.4
    • /
    • pp.185-192
    • /
    • 2007
  • Newly constructed road is a requisite to be able to carry out BMPs (Best Management Practices) under TMDL(Total Maximum Daily Load) program of the Ministry of Environment. BMPs require pollutant source control during road construction and wash off reduction plan as well as maintenance practices subsequent to construction on the purpose of discharging the minimum wash off non-point source pollutants. The objective of this study is to provide supportive discharged data in evaluating the discharged non-point pollutant load from a highway toll gate area. It can be applied to manage non-point source pollutants on roads. The results validate the first flush phenomenon that it is known to be one of the wash off characteristics in paved area. In addition, the load per unit area and load per unit rainfall duration applying EMC are calculated. The mean load per unit rainfall duration is assessed to be $533.7mg/m^2-hr$ for TSS, $396.2mg/m^2-hr$ for COD, $17.0mg/m^2-hr$ for TN, and $4.8mg/m^2-hr$ for TP. These results show the unitload taken from monitoring are higher than the unit load suggested in the TMDL. It is important to adopt real pollutant unit for road to be able to perform BMP successfully.

  • PDF

EFFECT OF PLASTICIZERS ON THE PROPERTIES OF COSMETIC MASK USING POLYVINYL ALCOHOL(PVA) AS A FILM FORMER

  • Park, J.H.;Kyong, K.Y.;Kwak, T.J.;Yoon, M.S.;Kang, S.H.
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.25 no.4 s.34
    • /
    • pp.51-55
    • /
    • 1999
  • Cosmetic mask is one of the traditional cosmetic product and is used to keep skin healthy and beautiful through moisturizing effect, cleansing effect and acceleration effect on microcirculation. There are several types of cosmetic mask such as peel-off type, tissue-off type, wash-off type and cotton sheet type immersed in cosmetic water. It is important for cosmetic formulators to develop an adequate type of cosmetic mask that meets the needs of the target consumers because each type of cosmetic mask has benefits and problems in its usage and efficacy. Polyvinyl alcohol (PVA) is widely used as an active ingredient of peel-off type cosmetic mask and the physical property of the PVA film changes with the usage of other ingredients. We studied the change of physical properties of the film containing PVA by formulating peel-off type cosmetic mask with the variation of humectants. Methylguceth-20 and glycereth-26 reduce the interaction between skin surface and PVA film without serious weakening of tensile strength and they can alleviate irritation. Glycerin, urea and betaine help PVA film soften and they also have excellent efficacy as humectants.

  • PDF

EFFECT OF PLASTICIZERS ON THE PROPERTIES OF COSMETIC MASK USING POLYVINYL ALCOHOL (PVA) AS A FILM FORMER

  • Park, J.H.;K.Y.Kyong;Kwak, T.J.;Yoon, M.S.;Kang, S.H.
    • Proceedings of the SCSK Conference
    • /
    • 1999.10a
    • /
    • pp.51-55
    • /
    • 1999
  • Cosmetic mask is one of the traditional cosmetic product and is used to keep skin healthy and beautiful through moisturizing effect, cleansing effect and acceleration effect on microcirculation. There are several types of cosmetic mask such as peel-off type, tissue-off type, wash-off type and cotton sheet type immersed in cosmetic water. It is important for cosmetic formulators to develop an adequate type of cosmetic mask that meets the needs of the target consumers because each type of cosmetic mask has benefits and problems in its usage and efficacy. Polyvinyl alcohol (PVA) is widely used as an active ingredient of peel-off type cosmetic mask and the physical property of the PVA film changes with the usage of other ingredients. We studied the change of physical properties of the film containing PVA by formulating peel-off type cosmetic mask with the variation of humectants. Methylguceth-20 and glycereth-26 reduce the interaction between skin surface and PVA film without serious weakening of tensile strength and they can alleviate irritation. Glycerin, urea and betaine help PVA film soften and they also have excellent efficacy as humectants.

  • PDF

Wash-off Characteristics of NPS Pollutants from Forest Landuse (산림지역의 비점오염물질 유출특성 및 EMC 산정)

  • Choi, Ji-Yeon;Lee, So-Young;Kim, Lee-Hyung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.4
    • /
    • pp.129-134
    • /
    • 2009
  • As a result of improved wastewater treatment facilities, the point source pollution emitted from human and municipal wastes is greatly decreasing. Conversely, the non-point source (NPS) pollution emanated from city streets, rural homes, suburban development, animal feedlot, croplands, and forestry is rapidly increasing. Practically, the main concern of the government is to control NPS pollutants by means of establishing a long term plan in order to protect the aqua-ecosystem. Studies have been conducted to assess the intensity of NPS from various landuses. In Korea, the data on NPS pollutant loadings are limited to few and broadly categorized landuses unlike in USA wherein specific landuses are available. This research aims to characterize the wash-off characteristics of NPS pollutants from forest landuse. Two sites were monitored during 15 storm events from 04/2008 to 10/2008. Mean $BOD_5$ EMCs are 1.13 mg/L and 0.91 mg/L for the two sites, respectively. The results of this research will be a helpful contribution for the assessment of total NPS pollutant loadings.