• 제목/요약/키워드: wall panels

검색결과 241건 처리시간 0.025초

외부화염에 의한 드라이비트의 소손패턴 연구 (A Study on the Damaged Pattern of Dryvit by External Flame)

  • 박영주;홍이표;이해평
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.40-47
    • /
    • 2015
  • In this study, temperature characteristics and fire damage form were analyzed to investigate flame spreading form and fire probability from ignition sources subject to drivit component materials which is finishing material in architecture. Ignition sources were limited to a gas torch and exterior panel board fire, and the size of the sample was manufacture in 30 cm length ${\times}$ 50 cm height ${\times}$ 5cm thickness size. Marble (inner wall) + 3 mm drivit (outer wall), marble (inner wall) + 4 mm plaster stone (outer wall), sandwich panel + 3 mm driver bit (outer wall), sandwich panel + 3 mm driver bit + insulation (outer wall), and gypsum board (inner wall) + 3 mm drivit (outer wall) were prepared for the sample. As result of the research for temperature characteristics, large temperature difference by each material was shown in $218^{\circ}C{\sim}995^{\circ}C$ at 30 seconds and $501^{\circ}C{\sim}1078^{\circ}C$ at 300 seconds. Especially when the inner wall was a plaster board, lowest temperature of $501^{\circ}C$ was shown at 300 seconds and marble inner wall showed the following lowest temperature of $900^{\circ}C$. Temperature rising over $1000^{\circ}C$ was shown in other materials. Regarding fire damage form, drivit or gypsum board outer wall parts exposed to fire showed combustion and carbonization to show calcination(breaking phenomenon) and influence of heat exposure was higher as calcination became more severe.

경량칸막이 복합벽체의 가열온도에 따른 전도 열전달 특성 연구 (Study on the Characteristics of Conduction Heat Transfer According to the Heating Temperature of a Composite Wall in a Light-weight Partition)

  • 박상민;최수길;김시국
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.60-68
    • /
    • 2019
  • 본 논문은 실내 공간구획에 사용되는 경량칸막이 복합벽체의 가열온도에 따른 이면부로의 전도 열전달 특성에 관한 연구이다. 경량칸막이 벽체로 일반적으로 사용되고 있는 복합재료로 구성된 스터드 칸막이, SGP 칸막이, 샌드위치 패널, 우레탄폼 패널, 그라스울 패널을 실험시료로 선정하고, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$의 가열온도를 하단부 표면에 1800 s 동안 인가하여 상단부 표면인 이면부로의 전도 열전달 특성을 분석하였다. 실험결과 가열온도가 최대 $500^{\circ}C$로 인가됨에 따라 최대 이면온도는 스터드 칸막이 $51.6^{\circ}C$, SGP 칸막이 $63.6^{\circ}C$, 샌드위치 패널 $317.2^{\circ}C$, 우레탄폼 패널 $124.9^{\circ}C$, 그라스울 패널 $42.2^{\circ}C$로 측정되었다. $500^{\circ}C$에서의 최대 전도 열전달율은 스터드 칸막이 17.16 W, SGP 칸막이 18.39 W, 샌드위치 패널 136.65 W, 우레탄폼 패널 14.34 W, 그라스울 패널 5.57 W로 측정되었다.

침엽수 합판의 구조용 및 콘크리트 거푸집용으로서의 성능 평가 (Performance Evaluation of Softwood Plywood as Structural and Concrete-Form Panels)

  • 이전제;김광철;이국식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제28권3호
    • /
    • pp.14-24
    • /
    • 2000
  • 본 연구에서는 향후 공급량이 증가될 것으로 예상되는 라디아타소나무와 국산 낙엽송의 두 수종을 이용하여 합판을 제조하고 구조용 합판 및 콘크리트 거푸집용 합판으로서의 사용 가능성을 검토하고자 하였다. 먼저, 기초적인 재질을 평가하기 위하여 합판의 재질시험 및 못성능 등의 시험을 실시하였고, 콘크리트조 주택 혹은 목조주택 등의 구조용 재료로의 사용을 검토하기 위해 집중하중과 균일분포하중에 의한 구조성능 시험 및 콘크리트 거푸집용으로서의 성능시험을 실시하였다. 합판의 기초 재질에 해당되는 비중, 너비 굽음, 길이 굽음 비틀림에 대한 실험 결과, 구조용 재료로서의 기준을 만족하였다. 못 측면 저항력, 못 인발 저항력 그리고 못머리 관통력에 대한 실험 결과, 구조용 재료로서의 벽체나 지붕재에 대한 표준성능을 만족하였다. 이들 두 수종으로 제조한 합판의 경우, 집중하중과 균일 분포하중에 의한 구조성능 평가, 콘크리트 거푸집용으로서의 성능 평가 결과를 볼 때 구조용 덮개재, 바탕바닥 마감재, 콘크리트 거푸집용 재료로의 사용이 가능하다고 판단되었다.

  • PDF

공동주택 경량칸막이 벽체구성재 분류별 사용자 평가 및 특성 분석 (Analysis of Characteristics and User's Evaluation for Lightweight Panel in Apartment)

  • 박현구
    • 한국건축시공학회지
    • /
    • 제10권1호
    • /
    • pp.181-191
    • /
    • 2010
  • 최근 공동주택, 오피스 등 고층 초고층 건물의 경량화, 공간의 가변성, 시공의 용이성, 공기단축 등 설계, 시공상의 요구조건을 충족시키기 위하여 가변화된 건식부재로 벽체를 구성하고 있으며, 조적방식의 칸막이 벽체의 개선이나 건식 및 조립공법과 같은 새로운 경량칸막이 벽체 공법 개발에 대한 관심이 증가되고 있다. 공동주택 등 주거용 건축물의 경우 구조적 안전성이나 내구성 외에 거주성 및 환경성, 프라이버시 등의 추가성능 확보가 요구되면서, 벽체계획 시 제반 요구성능에 대한 종합적 분석 및 검토와 대안별 비교평가를 통한 적합공법 선정을 위한 기초자료가 필요하다. 즉, 현장 및 건축물의 특성, 설계 및 시공 시 요구성능을 고려한 경량칸막이 벽체구성재의 분류와 성능평가를 통한 적정자재 및 공법선정에 활용될 수 있는 기초자료의 확보가 필요하다. 이에 본 연구에서는 국내 공동주택에서 주로 사용되고 있는 경량칸막이 벽체구성재의 시공현황을 조사하고, 벽체구성재 종류별 특성을 파악하여 분류한 후, 시공자 관점에서의 성능평가를 실시하여 제시하였다.

다공패널형 공명기의 흡음성능에 관한 연구 (A Study on the Absorption Performance of a Perforated Panel type of Resonator)

  • 송화영;양윤상;이동훈
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.224-231
    • /
    • 2016
  • When aiming to reduce the low frequency noise of a subway guest room through sound absorbing treatment methods inside the wall of a tunnel the resonator is often more effective than a porous sound absorbing material. Therefore, the perforated panel type resonator embedded with a perforated panel is proposed. The perforated panel is installed in the neck, which is then extended into the resonator cavity so that it can ensure useful volume. The absorption performance of the perforated panel type of resonator is obtained by acoustic analysis and experiment. The analytical results are in good agreement with the experimental results. In the case of multiple perforated panel type resonators, as the number of perforated panels increase, the 1st resonance frequency is moved to a low frequency band and sound absorption bandwidth is extended on the whole. In order to obtain excellent absorption performance, the impedance matching between multi-panels should be considered. When the perforated panel in the resonator is combined with a porous material, the absorption performance is highly enhanced in the anti-resonance and high frequency range. In case of the resonator inserted with perforated panels of 2, the 2nd resonance frequency is shifted to a low frequency band in proportion to the distance between perforated panels.

경량기포콘크리트 재료를 활용한 커튼월 구법에 관한 일본 특허기술의 분석 연구 (Patent Investigations and Analysis for the Curtain Wall System based on the Autoclaved Lightweight Concrete(ALC))

  • 김영호
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권1호
    • /
    • pp.81-88
    • /
    • 2012
  • According to the survey results of the Ministry of Land, Transport and Maritime Affairs in the end of December 2011, the residential buildings was reported as 67.3% of 4,529,464 buildings. Reflected in the national energy policy, the residential building is expected that greater energy savings. To have realized the Passive House Project used the Autoclaved Lightweight Concrete(ALC) material on exterior wall, we take advantage of a very large energy savings. Therefore, this study investigate the patent documents of three major companies, SUMITOMO, CLION, ASAHI KASEI, in Japan. and analyze technical flow and benchmarking patent. As a result, the Sliding method or the Rocking method of ALC panels how to install is to be superior to high-performance drift and safety by a earthquake. And the embedded anchor in panel needs to improve the shape and the strength of bearing. Thus installation technology of the ALC exterior wall investigated in japanese patent documents is expected to the fastening units and anchors.

The Study on Thermal Performance Evaluation of Building Envelope with VIPs

  • Jeon, Wan-Pyo;Kwon, Gyeong-Jin;Kim, Jin-Hee;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.5-10
    • /
    • 2016
  • Purpose: The energy consumption in buildings has continuously increased in some countries and it reaches almost 25% of the total energy use in korea. Therefore there are various efforts to minimize energy consumption in buildings, and the regulations on building envelope insulation have been tightened up gradually. To satisfy the building regulation, the use of vacuum insulation panels(VIPs) is increasing. VIP is a high performance insulation materials, so that it can be thinner than conventional insulation material. When VIP is applied in a building, it may cause thermal bridge, which occurs due to very low thermal conductivity compared to other building materials and the envelope of VIPs. Method: This study designed the capsulized VIPs using conventional insulation for reduction of the thermal bridge. Then designed VIPs were applied to a wall. The linear thermal transmittance and the effective thermal conductivity were analyzed by HEAT2 simulation program for two dimensional steady-state heat transfer. The result compared with a wall with non-capsulized VIPs. Result: It analyzed that the wall with capsulized VIPs had lower linear thermal transmittance and reduced the difference of the effective thermal transmittance with one dimensional thermal transmittance compared to that of the wall with non-capsulized VIPs.

반복 횡하중을 받는 프리캐스트 대형 콘크리트 판구조의 이력특성에 관한 실험적 연구 (Hysteretic Behavior of Precast Concrete Large Panel Structures Subjected to Horizontal Cyclic Loading)

  • 서수연;이원호;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.253-260
    • /
    • 1999
  • Main objective of this study is to examine the hysteretic behaviors and to evaluate the capacity of precast concrete (PC) large panel structures simulated from the prototype of 15-story building, Two 1/2 scaled precast concrete wall specimens and one monolithic reinforced concrete specimen were designed and tested under the cyclic loading conditions. The main parameter of test specimens in PC large panel structure is the type of details for vertical continuity of vertical steel in horizontal joint. Also the behaviors of PC large panel structures are compared with that of monolithic reinforcement concrete wall structure. From the results, the stiffness and energy dissipation ratio of the precast concrete specimens are shown little bit lower than those of monolithic reinforced concrete specimen. In the PC large panel structures, the specimen connected vertically by welding (strong connection) showed higher strength than that of the specimen connected vertically by joint box. However the failure pattern of the former showed more brittle than that of the latter due to the diagonal compressive failure of wall panels.

  • PDF

Experimental and AI based FEM simulations for composite material in tested specimens of steel tube

  • Yahui Meng;Huakun Wu;ZY Chen;Timothy Chen
    • Steel and Composite Structures
    • /
    • 제52권4호
    • /
    • pp.475-485
    • /
    • 2024
  • The mechanical behavior of the steel tube encased high-strength concrete (STHC) composite walls under constant axial load and cyclically increasing lateral load was studied. Conclusions are drawn based on experimental observations, grey evolutionary algorithm and finite element (FE) simulations. The use of steel tube wall panels improved the load capacity and ductility of the specimens. STHC composite walls withstand more load cycles and show more stable hysteresis performance than conventional high strength concrete (HSC) walls. After the maximum load, the bearing capacity of the STHC composite wall was gradually reduced, and the wall did not collapse under the influence of the steel pipe. For analysis of the bending capacity of STHC composite walls based on artificial intelligence tools, an analysis model is proposed that takes into account the limiting effect of steel pipes. The results of this model agree well with the test results, indicating that the model can be used to predict the bearing capacity of STHC composite walls. Based on a reasonable material constitutive model and the limiting effect of steel pipes, a finite element model of the STHC composite wall was created. The finite elements agree well with the experimental results in terms of hysteresis curve, load-deformation curve and peak load.

고대 로마의 실내 장식벽화가 과학적인 원근법에 미친 영향 연구 (A Study on Effects of Decorative Interior Wall Paintings of the antique Rome on the Scientific Perspective)

  • 홍재동
    • 건축역사연구
    • /
    • 제11권3호
    • /
    • pp.69-86
    • /
    • 2002
  • Under the assumption that techniques of interior decoration often frequently used by people of the antique Greece and Rome became basis for scientific perspective in the period of Renaissance, this study analyzed characteristics of wall paintings excavated as relics of the antique Greece and Rome. The result of the study can be summarized as follows ; (1) Decorative wall paintings which were and have been excavated from relics of the antique Roman cities are characterized by single and multiple point techniques as their perspective. The two techniques were later adapted by people of the Baroque in the 16th century who recognized and expressed space through putting it into a certain framework. (2) Such antique wall paintings drawn using the technique of single point clearly indicate that the technique was not fully created in the period of Renaissance but developed by people of the antique Greece and Rome. Unlike its present form, the technique was unsophisticated and poor in many respects when first created. Since then, it has become manipulated as spatial recognition has been developed in various ways. (3) Illustrations on vase surfaces or wall-decorative painting panels of the antique Greece were painted mainly through the technique of multiple points which helped changes in the sense of space. The technique were later complied with by the theory of cubism which was emerged in the late 19th century. In other words, the technique was developed over times into a basis of the theory. (4) Some of the antique Roman and Greek wall paintings were drawn by using the method of single point perspective. When the height of the wall foundation, 90cm, as specified in [Ten Books of Architecture] by Vitrubius, the viewpoint for the method almost complied with the height of spectators' view, or 150cm. This height is almost same as the height of the view point employed by wall paintings in the Renaissance period.

  • PDF