• Title/Summary/Keyword: wall defect

Search Result 432, Processing Time 0.022 seconds

Reconstruction of Thoracic Wall Defect in Tumors of Chest Wall -Report of Four Cases- (흉벽에 발생한 종양 -흉벽 재건술 4례-)

  • 이선희;김세화;이홍균
    • Journal of Chest Surgery
    • /
    • v.8 no.1
    • /
    • pp.29-36
    • /
    • 1975
  • We have experienced 49 cases of tumors of chest wall at St. Mary`s Hospital from Jan. 1963 to Dec.1974. In four cases of them, the reconstruction of chest wall defects performed. 1] Out of 49 cases of tumors of the chest wall, 27 cases were benign tumors, 14 cases metastatic malignant tumors, and 8 cases primary malignant tumors. 2] Twenty-six cases [50%] of tumors of the chest wall were on the bony cage. Among them benign tumors were 9 cases [35%], metastatic malignant tumors 14 cases [53%], and primary malignant tumors 3 cases [12%]. Of these, 24 cases were located on the ribs and 2 cases on the sternum.3] The malignant tumors of bony chest wall were excised in en bloc resection including involved ribs. The wide defects of bony chest wall were reconstructed by means of displacement of neighboring ribs and mobilized diaphragm, in the two osteogenic sarcomas of rib, and of prosthesis with silastic sheets in one rhabdomyosarcoma and one metastatic adenocarcinoma of lung.

  • PDF

Experimental study on hybrid FRP-steel RC shear wall with replaceable dampers

  • Shiying Xiao;Mengfu Wang
    • Steel and Composite Structures
    • /
    • v.52 no.2
    • /
    • pp.217-236
    • /
    • 2024
  • The objective of this paper was to discuss the seismic performance of hybrid FRP-steel reinforced concrete shear wall with replaceable friction dampers at the feet of the wall. The hysteretic characteristics of five wall specimens were studied by pseudo-static loading tests. The results showed that the damage of the specimens was concentrated on the friction dampers, and the energy consumption capacity was increased while making up for the defect of low ductility of FRP reinforced wall specimens. And the repairability of the wall after earthquake was improved. Finally, a calculation method of initial stiffness of shear wall with replaceable dampers was proposed.

The study on the flow defect of cold combined forward-backward extrusion product (${\cdot}$후방 압출 제품의 유동 결함에 관한 연구)

  • Hwang S. H.;Lee D. J.;Kim B. M.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.05a
    • /
    • pp.79-82
    • /
    • 1999
  • This paper presents a study of cold combined forward-backward extrusion product. The case of product with thin wall in piercing process occur defects of deformation and breakdown during piercing process and the center web of product with thin thickness cause flow defect. Such defect is made by the difference of material flow. Methods of the material flow control in the two directions and forming process to remove this flow defect is proposed. The effectiveness of the proposed methods is examined by comparison experiment and finite element simulation.

  • PDF

Analysis of Relationship between Standard Depth of Penetration Skin Effect and Phase Angle of Defect Signal of Eddy Current Testing (와전류(渦電流) 표준침투(標準浸透) 깊이 표피효과(表皮效果)와 결함신호(缺陷信號) 위상각(位相角)의 관계해석(關係解析))

  • Chung, Tae-Eon;Chang, Kee-Oak;Park, Dae-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.2
    • /
    • pp.7-14
    • /
    • 1985
  • An experiment to investigate the rate of change of phase angle of eddy current output signal caused by outer surface defect of nonferromagnetic tube by variation of standard depth of penetration and variation of percent of tube wall penetration was carried out. The results of the experiment show that the phase angle of defect signal is increased with decreasing the standard depth of penetration or the depth of defect. The results also show that the phase angle is decreased with increasing the skin effect of eddy current, and that the resolution is decreased with decreasing the depth of defect.

  • PDF

Traumatic Ventricular Septal Defect Secondary to Nonpenetrating Chest Trauma -A Case Report- (비관통성 외상에 의한 심실중격결손증 -수술치험 1례-)

  • 홍기표
    • Journal of Chest Surgery
    • /
    • v.27 no.2
    • /
    • pp.161-165
    • /
    • 1994
  • We have experienced a case of ventricular septal defect due to blunt chest trauma. A 22 year old male patient was admitted due to chest pain after Motor cycle accident on July 1st,1993. On 5th hospital day, sudden onset of dyspnea was noted and auscultation represented newly developed systolic murmur. A cardiac catheterization and Left ventriculogram revealed ruptured septum at the apical portion. Because there was open wound on anterior chest wall and congestive heart failure was medically controlled, the patient was discharged for elective operation. He was readmitted on August 14th, 1993.At operation, ventricular septal defect was found in apico-posterior muscular septal area, about 2.0 x 1.5 cm in size. The defect was repaired by double velour patch with interrupted suture and ventriculotomy was closed with Teflon felt. The patient`s postoperative course was uneventful and discharged 10 days postoperatively without complication. The patient have been followed up~ for 2 months. He is on functional class I with small amount of residual shunt at the ventricular septum.

  • PDF

One Case Tratment of Multiple Ribs Fracture with Chest Wall Defects (by Use of Judet's Struts and Teflon Mesh) (Judet's Strut와 Teflon Mesh를 이용한 다발성 늑골골절 및 흉벽결손의 치험 1례)

  • 신윤곤
    • Journal of Chest Surgery
    • /
    • v.27 no.5
    • /
    • pp.422-426
    • /
    • 1994
  • Recently, we experienced one case of multiple ribs fracture with large chest wall defects. This patient was treated with internal fixation of ribs by use of Judet`s struts and reconstruction of chest wall defects by use of Teflon mesh. Postoperative outcome was satisfactory result and its advantages were reduced duration of operation, prevention of pulmonary herniation and reduced risk of postoperative infection.

  • PDF

Comparative Study for Compatibility of Acellular Dermis ($SureDerm^{TM}$) and Synthetic Material (PROCEED$^{(R)}$) on Abdominal Wall Defect in Rabbit Models (토끼의 전층 복벽 결손 재건에서 무세포진피 ($SureDerm^{TM}$)와 합성물질(PROCEED$^{(R)}$)에 대한 생체적합성 비교 연구)

  • Kang, Nak-Heon;Song, Seung-Han;Kang, Dae-Young;Ahn, Jae-Hyoung;Choi, Da-Mi;Kim, Jin-Young
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2011
  • Purpose: Deficiencies of the abdominal wall can be the a result of infection, surgery, trauma, or primary herniation. For abdominal wall reconstruction, synthetic materials have been shown to provide a better long-term success rate than primary fascial repair. But, synthetic materials cannot elicit angiogenesis or produce growth factor and are therefore plagued by an inability to clear infection. As a result of the inherent drawbacks of synthetic, significant effort has been spent on the identification of new bioprosthetic materials. The aim of our study is to evaluate the effectiveness of a synthetic material (PROCEED$^{(R)}$) and an ADM ($SureDerm^{TM}$) to repair abdominal wall defects in a rabbit models. Methods: We measured the tensile strength of the $SureDerm^{TM}$ and PROCEED$^{(R)}$ by a Tension meter (Instron 4482). 16 Rabbit models were assigned to this study for abdominal wall reconstruction. Abdominal defect of 8 rabbits were reconstructed by PROCEED$^{(R)}$ and the rest were reconstructed by $SureDerm^{TM}$. We assessed gross and histologic examinations for the reconstructed abdominal wall. Results: The tensile strength of $SureDerm^{TM}$ and Gore Tex$^{(R)}$ is $14.64{\pm}0.51Mpa$, $8.54{\pm}0.45Mpa$. PROCEED$^{(R)}$ was estimated above the limits of measurement. Inflammatory reaction of PROCEED$^{(R)}$ persisted for 32weeks, but $SureDerm^{TM}$ decreased after 16weeks. Vascular ingrowth into the $SureDerm^{TM}$ was seen after 32 weeks. The basement membrane of $SureDerm^{TM}$ changed into a form of pseudoperitoneum. In PROCEED$^{(R)}$, it seemed like pseudoepithelial lining was made from the fibrosis around the mesh. Conclusion: In our study, the $SureDerm^{TM}$ not only have less inflammatory reaction and presented more angiogenesis than the PROCEED$^{(R)}$, but also have pseudoperitoneum formation. It is expected that $SureDerm^{TM}$ is useful for abdominal wall reconstruction. However, a long-term study of its usage consequences are thought to be needed.

Simulation of Remote Field Scanner for Defect Evaluation of Water Wall Tube Within the Fluidized Bed Boiler (유동층보일러 수냉벽튜브 결함평가를 위한 원격자장 스캐너 시뮬레이션에 관한 연구)

  • Gil, Doo-Song;Jung, Gye-Jo;Seo, Jung-Seok;Kim, Hak-Joon;Kwon, Chan-Wool
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.145-150
    • /
    • 2020
  • Water wall tube is one of the major factors consisting of a fluidized bed boiler and it plays very important role for the generation of electricity within the boiler. But these water wall tubes within the fluidized bed boiler are subject to the ware and corrosion caused by the high temperature gas and the flowing medium. If water leak is occurred, the secondary damage by the water leak will occur. As a result of that, the power generation efficiency decreases noticeably. Therefore, the maintenance of the water wall tube is very important. In this study, we designed a exciter sensor based on simulation and composed a remote field eddy current system for the defect evaluation of the outer water wall tube. Starting from the shape design of exciter, we conducted simulations for various design factors such as the water wall tube size, material, frequency, lift-off and so on. Based on the results, we designed the optimum exciter sensor for the water wall tube test within the fluidized bed boiler.

The effects of Acellular dermal matrix on the healing of 1 wall intrabony defects in dogs (성견에서 Acelluar dermal matrix가 1면 골내낭 결손부의 치주조직 재생에 미치는 영향)

  • Park, Ju-Un;Kim, Byung-Ock;Park, Joo-Cheol;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.27-37
    • /
    • 2006
  • Although the main purpose of periodontal treatment to regenerate is the complete regeneration of periodontal tissue due to periodontal disease, most of the treatment cannot meet such purpose because healing by long epithelial junction. Therefore, diverse materials of resorbable and non-resorbable have been used to regenerate the periodontal tissue. Due to high risk of exposure and necessity of secondary surgical procedure when using non-resorbable membrane, guided tissue regeneration using the resorbable membrane has gain popularity, recently. However, present resorbable membrane has the disadvantage of not having sufficient time to regenerate date to the difference of resorption rate according to surgical site. Meanwhile, other than the structure stability and facile manipulation, acellular dermal matrix has been reported to be a possible scaffold for cellular proliferation due to rapid revascularization and favorable physical properties for cellular attachment and proliferation. The purpose of this study is to estimate the influence of acellular dermal matrix on periodontal ligament, cementum and alveolar bone when acellular dermal matrix is implanted to 1-wall alveolar bone defect. 4 dogs of 12 to 16 month old irrelevant to sex , which below 15Kg of body weight, has been used in this study. ADM has been used for the material of guided tissue regeneration. The 3rd premolar of the lower jaw was extracted bilaterally and awaited for self-healing. subsequently buccal and lingual flap was elevated to form one wall intrabony defect with the depth and width of 4mm on the distal surface of 2nd premolar and the mesial surface of 4th premolar. After the removal of periodontal ligament by root planing. notch was formed on the basal position. Following the root surface treatment, while the control group had the flap sutured without any treatment on surgically induced intrabony defect. Following the root surface treatment, the flap of intrabony defect was sutured with the ADM inserted while the control group sutured without any insertion. The histologic specimen was observed after 4 and 8 weeks of treatment. The control group was partially regenerated by periodontal ligament, new cementum and new alveolar bone. the level of regeneration is not reached on the previous formed notch. but, experimental group was fully regenerated by functionally oriented periodontal ligament fiber. new cementum and new alveolar bone. In conclusion, we think that ADM seems to be used by scaffold for periodontal ligament cells and the matrix is expected to use on guided tissue regeneration.

Patch Reinforcement and Safety Evaluation for Pressure Vessel with Internal Wall Thinning (내부 부식 감육부를 갖는 압력용기의 패치 보강 및 안전성 평가)

  • Song, Tae-Kwang;Chun, Yun-Jae;Myung, Man-Sik;Kim, Yon-Jae;Lee, Tae-Hee;Park, Ji-Yoon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.22-29
    • /
    • 2008
  • This paper provides the evaluation method for the pressure vessel with internal wall-thinning defect, which is based on ASME design criteria. Pressure vessel has wall-thinning partially and patch reinforcement has been attached for reliable operating. However, present partial wall thinning could be through wall thinning at the next inspection time with present corrosion progress speed. Therefore safety margin was calculated for various conditions from present wall-thinning condition to additive patch reinforced condition via two-dimensional and three-dimensional, geometrically linear FE analyses using elastic materials.