• Title/Summary/Keyword: wall defect

Search Result 432, Processing Time 0.023 seconds

Defect formation mechanism of 6H-SiC crystals grown by sublimation method

  • Kim, Hwa-Mok;Kyung Joo;Auh, Keun-Ho
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1998.09a
    • /
    • pp.35-40
    • /
    • 1998
  • There have two kinds of defects, planar defects and vertical defects which were called micropipes in SiC bulk crystals grown by a sublimation method. We could decrease these defects by adding a little piece of Si in the SiC powder or using Ta cylinder in the crucible. so were report the dependence of these defects in a wafer on silicon/carbon ratio in this paper. The chemical species sublimed from SiC powder is affected by carbon from the graphite wall of the crucible. It is important to control the chemical species on the substrate.

  • PDF

Ileocecocolic and Colocolic Intussusception in a Young Jindo

  • Jung, Joo-Hyun;Chae, Woong-Joo;Kwon, Do-Hyoung;Chang, Jin-Hwa;Oh, Sun-Kyoung;Yoon, Jung-Hee;Choi, Min-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.25 no.6
    • /
    • pp.549-552
    • /
    • 2008
  • An eight-month-old, intact female Jindo, weighing 9 kg with a one-day history of acute bloody diarrhea was referred. Plain abdominal radiographic findings included evidence of a soft tissue tubular mass within the dilated colon. In ultrasonographs, a target-like mass was identified with multiple hyperechoic and hypoechoic parallel wall layers. A barium enema showed a large radiolucent filling defect within the colon and a completely occlusive lumen. On the basis of these images, ileocecocolic and colocolic intussusception was diagnosed. Surgical manual reduction, resection and anastomosis were performed. The patient recovered normally without any complications or recurrence.

Growth and effect of thermal annealing for $AgGaS_2$ single crystal thin film by hot wall epitaxy (Hot wall epitaxy(HWE)법에 의한 $AgGaS_2$ 단결정 박막 성장과 열처리 효과)

  • Moon Jongdae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • A stoichiometric mixture of evaporating materials for AgGaS₂ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, AgGaS₂ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the hot wall epitaxy (HWE) system. The source and substrate temperatures were 590℃ and 440℃, respectively. The temperature dependence of the energy band gap of the AgGaS₂ obtained from the absorption spectra was well described by the Varshni's relation, E/sub g/(T) = 2.7284 eV - (8.695×10/sup -4/ eV/K)T²/(T + 332 K). After the as-grown AgGaS₂ single crystal thin films was annealed in Ag-, S-, and Ga-atmospheres, the origin of point defects of AgGaS₂ single crystal thin films has been investigated by the photoluminescence (PL) at 10 K. The native defects of V/sub Ag/, V/sub s/, Ag/sub int/, and S/sub int/ obtained by PL measurements were classified as a donors or accepters type. And we concluded that the heat-treatment in the Ag-atmosphere converted AgGaS₂ single crystal thin films to an optical n-type. Also, we confirmed that Ga in AgGaS₂/GaAs crystal thin films did not form the native defects because Ga in AgGaS₂ single crystal thin films existed in the form of stable bonds.

Growth and effect of thermal annealing for $AgGaSe_2$ single crystal thin film by hot wall epitaxy (Hot wall epitaxy(HWE)법에 의한 $AgGaSe_2$ 단결정 박막 성장과 열처리 효과)

  • Baek, Seung-Nam;Hong, Kwang-Joon;Kim, Jang-Bok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.16 no.5
    • /
    • pp.189-197
    • /
    • 2006
  • A stoichiometric mixture of evaporating materials for $AgGaSe_2$ single crystal thin films was prepared from horizontal electric furnace. To obtain the single crystal thin films, $AgGaSe_2$ mixed crystal was deposited on thoroughly etched semi-insulating GaAs(100) substrate by the hot wall epitaxy(HWE) system. The source and substrate temperatures were $630^{\circ}C\;and\;420^{\circ}C$, respectively. The temperature dependence of the energy band gap of the $AgGaSe_2$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)=1.9501eV-(8.79x10^{-4}eV/K)T^2(T+250K)$. After the as-grown $AgGaSe_2$ single crystal thin films was annealed in Ag-, Se-, and Ga-atmospheres, the origin of point defects of $AgGaSe_2$ single crystal thin films has been investigated by the photoluminescence (PL) at 10K. The native defects of $V_{Ag},\;V_{Se},\;Ag_{int},\;and\;Se_{int}$ obtained by PL measurements were classified as a donors or accepters type. And we concluded that the heat-treatment in the Ag-atmosphere converted $AgGaSe_2$ single crystal thin films to an optical p-type. Also, we confirmed that Ga in $AgGaSe_2$/GaAs did not form the native defects because Ga in $AgGaSe_2$ single crystal thin films existed in the form of stable bonds.

Analysis of Polar Maps of Dipyridamole Stress/Rest $^{99m}Tc$-MIBI Myocardial SPECT in 14 Healthy Young Men (건강한 청년 남자 14 례에서 Dipyridamole 부하 $^{99m}Tc$-MIBI 심근 SPECT 극성지도의 분석)

  • Cho, Ihn-Ho;Sin, Dong-Gu;Lee, Hyoung-Woo;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.146-152
    • /
    • 1994
  • We performed the same day dipyridamole stress/rest myocardial SPECT in 14 healthy young men, reconstructed the polar maps according to Cedars-Sinai method and quantitated the radioactivity of myocardial wall. We divided the whole myocardium to 9 sectors. The latero-anterior wall contains the highest count. The infero-septal wall contains the lowest count. There isn't any significant differences of radioactivity in each segment between stress and rest polar map. The hemodynamic parameters after dipyridamole injection in the subjects were significantly changed except systolic blood pressure : the heart rate was increased and diastolic blood pressure was decreased. Adverse effects were reported in 85.7%. We suggest that these data can be used to dectect perfusion defect in the coromary artery disease.

  • PDF

Implementation of Water Bolus in Patient with Large Tissue Defect (조직결손이 큰 환자에서 물 볼루스의 적용에 관한 고찰)

  • Park, Hyo-Kuk;Lee, Sang-Kyu;Yoon, Jong-Won;Cho, Jeong-Hee;Kim, Dong-Wook;Kim, Joo-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.105-112
    • /
    • 2006
  • Purpose: To demonstrate that water bolus in the patient surface can decrease the dose inhomogeneity by patient surface large tissue defect when the surface is in an electron-beam field. And We tried to find a easy way to water control. Methods and Materials: To demonstrate the use of water bolus in the irregular surface clinically, the case of a patient with myxofibrosarcoma of the chest wall who was treated with electrons. We obtained dose distribution using missing tissue option of PINACLE 6.2b (ADAC, USA). We fabricate a Mev-green for water bolus in patient with defect of tissue. Then put the water bolus which is vinyl packed water into the designed Mev-green. We peformed CT scan with CT-simulator. Three-dimensional (3D) dose distributions with and without water bolus in the large irregular chest wall were calculated for a representative patient. Resulting dose distributions and dose-volume histograms of water bolus were compared with missing tissue option and non bolus plans. We fabricate a new water control device. Results: Controlled Water bolus markedly decrease the dose heterogeneity, and minimizes normal tissue exposure caused by the surface irregularities of the chest wall mass. In the test case, The non bolus plan has a maximum target dose of 132%. After applying water bolus, the maximum target dose has been reduced substantially to 110.4%. The maximum target dose was reduced by 21.6% using this technique. Conclusion: The results showed that controlled water bolus could significantly improve the dose homogeneity in the PTV for patients treated with electron therapy using water control device. This technique may reduce the incidence of normal organ complications that occur after electron-beam therapy in irregular surface. And our new device shows handiness of water control.

  • PDF

Experimental Study on Rupturing of Artificial Flaw of Pipes for Life Prediction of Underground High Pressure Gas Pipes (지하매설 고압가스배관의 수명예측을 위한 인위결함 배관의 파열실험)

  • Lee, Kyung-eun;Kim, Jeong Hwan;Ha, Yu-jin;Kil, Seong-Hee;Jo, Young-do;Moon, Jong-Sam
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.62-71
    • /
    • 2018
  • According to own investigation conducted by Korea Gas Safety Corporation Gas Safety Research Institute in 2017, the length of underground pipes in domestic high-pressure gas pipelines is approximately 770km, of which 84% is buried in Ulsan and Yeosu industrial complexes. In particular, 56% of underground pipelines have been in operation for more than 20 years. This suggests urgent management of buried high pressure gas pipelines. PHMSA in US and EGIG in Europe, major causes of accidents in buried gas pipelines are reported as third party damage, external corrosion and loss of pipe wall thickness. Therefore, it is important to evaluate whether the defects affect the remaining life of the pipe when defects occur in the pipe. DNV and ASME have evaluated the residual strength of pipelines through the hydraulic rupture test using pipe specimens with artifact flaws. Once the operating pressure is known through the residual strength of the pipe, the wall thickness at the point at which the pipe ruptures is calculated. If we know the accurate rate of corrosion growth, we can predict the remaining life of pipe. In the study, we carried out experiments with A53 Grade.B and A106 Grade.B, which account for 80% of domestic buried pipes. In order to modify the existing model equation, specimens with a defect depth of 80% to 90% was tested, and a formula expressing the relationship between defect and residual strength was made.

Comparison between $180^{\circ}$ and $360^{\circ}$ Data Collection in $^{99m}Tc-MIBI$ Myocardial SPECT ($^{99m}Tc-MIBI$ 심근 SPECT에서 180도와 360도 데이터 집적의 비교)

  • Kang, Keon-Wook;Lee, Dong-Soo;Kwark, Cheol-Eun;Hyun, In-Young;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.478-483
    • /
    • 1995
  • We compared the influences of reconstruction methods using $180^{\circ}$ or $360^{\circ}$ data upon contrasts and discriminating capability and diagnostic accuracy in $^{99m}Tc-MIBI$ stress/rest myocardial SPECT. We reviewed SPECT images reconstructed only with $180^{\circ}$ projection data or with $360^{\circ}$ data in 18 patients and in 11 normal subjects. To compare counts of surface structures and deep structures, we measured ape# posterior wall ratios in 11 normal subjects. To compare the contrasts of images, we measured apex/ventricle ratios. To compare contrasts between normal and diseased myocardial segments, we measured count ratios of defect and normal segments in 4 patients who had single coronary artery diseases. To compare diagnostic accuracy, we scored SPECT images made with $180^{\circ}$ and $360^{\circ}$ data segmentally. Sensitivity and specificity for the diagnosis of coronary artery disease and for the revelation of diseased arteries with both $180^{\circ}$ and $360^{\circ}$ SPECT images. If involved coronary arteries had more narrowing than 50% In coronary angiogram, we considered them as diseased arteries Apex/posterior wall ratios were not different significantly in normal subjects. Apex/ ventricle ratios in normal subjects were different significantly between $180^{\circ}$ and $360^{\circ}$ SPECT images. Defect/normal ratios were different significantly between $180^{\circ}$ and $360^{\circ}$ SPECT images in single vessel disease patients. The overall diagnostic accurracy was the same between $180^{\circ}$ and $360^{\circ}$ data collection. Sensitivity was 94% and specificity was 91% for both types of data collection in this sample population. Sensitivity and specificity of each coronary artery territory were not significantly different between the images made with $180^{\circ}$ and $360^{\circ}$ data. The images made with $180^{\circ}$ data had better contrast between ventricle and myocardium and between hypoperfused and normal myocardium, though no difference was found between the ratios of the myocardial counts of surface and deep structures. However, diagnostic sensitivities of diseased artery territories were not different significantly and so were overall diagnostic accuracy between both methods of making images with $180^{\circ}$ and $360^{\circ}$ data.

  • PDF

Magnetic Properties of Transition Metal Doped La0.5Ca0.5(Mn0.98TM0.02)O3(TM=Cr, Ti) (전이금속을 치환한 란탄망간산화물계 La0.5Ca0.5(Mn0.98TM0.02)O3(TM=Cr, Ti)의 자성 특성 연구)

  • Kang, J.H.;Jun, S.J.;Park, J.S.;Lee, Y.P.;Lee, Y.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.14-17
    • /
    • 2007
  • Magnetic properties of transition metal doped $La_{0.5}Ca_{0.5}(Mn_{0.98}TM_{0.02})O_3$(TM=Cr and Ti) are studied. The samples are synthesized by the conventional solid-state method. Using vibrating sample magnetometer magnetization-temperature measurement were carried out with zero field cooling and field cooling at 50 Oe. Cr-doped sample shows cluster or spin glass like behavior while Ti doped does not. Curie temperature obtained were decreased from that of LCMO(245.5 K). Curie temperatures of Cr-doped and Ti-doped samples are 235.5 K and 232.7 K, respectively. The temperature-dependent coercivity $H_c(T)$ was also measured. The coercive force continuously decreases with the substitution of Cr and Ti, The result can be understood in terms of the interaction between defect and domain wall.

$BBPY^{(R)}$ graft for periodontal intrabony defects and molar furcation lesions: Case Report (다양한 치주 골내낭과 이개부 병변의 처치를 위한 $BBP^{(R)}$ 이식재의 임상적 효과)

  • Kim, Myung-Jin;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.1
    • /
    • pp.97-102
    • /
    • 2008
  • Purpose: Periodontal intrabony defects have great deal of importance since they contribute to the development of periodontal disease. Current treatment regimens for intrabony defects involve grafting of numerous bony materials, GTR using biocompatible barriers, and biomodification of root surface that will encourage the attachment of connective tissue. Xenograft using deproteinized bovine bone particles seems to be very convenient to adjust because it doesn't require any donor sites or imply the danger of cross infections. These particles are similar to human cancellous bone in structure and turned out to be effective in bone regeneration in vivo. We here represent the effectiveness of grafting deproteinized bovine bone particles in intrabony defect and furcation involvements that have various numbers of bony walls. Materials and methods: Open flap debridement was done to remove all root accretions and granulation tissue from the defects within persisting intrabony lesions demonstrating attachment loss of over 6mm even 3 months after nonsurgical periodontal therapy have been completed. Deproteinized bovine bone particles($BBP^{(R)}$, Oscotec, Seoul) was grafted in intrabony defects to encourage bone regeneration. Patients were instructed of mouthrinses with chlorohexidine-digluconate twice a day and to take antibiotics 2-3 times a day for 2 weeks. They were check-up regularly for oral hygiene performance and further development of disease. Probing depth, level of attachment and mobility were measured at baseline and 6 months after the surgery. The radiographic evidence of bone regenerations were also monitored at least for 6 months. Conclusion: In most cases, radio-opacities increased after 6 months. 2- and 3-wall defects showed greater improvements in pocket depth reduction when compared to 1-wall defects. Class I & II furcation involvements in mandibular molars demonstrated the similar results with acceptable pocket depth both horizontally and vertically comparable to other intrabony defects. Exact amount of bone gain could not be measured as the re-entry procedure has not been available. With in the limited data based on our clinical parameter to measure pocket depth reduction following $BBP^{(R)}$ grafts, it was comparable to the results observed following other regeneration techniques such as GTR.