• Title/Summary/Keyword: wall boundary

Search Result 1,048, Processing Time 0.029 seconds

A Study on the Changing Patterns of the Ancient Buddhist Temples of Korea - Based on the Analysis about Development of View of Buddha-kaya, Change of Status of Stupa and Statue of the Buddha - (한국고대가람 변천양상에 관한 불교사적 고찰 - 불신관의 발전과 불탑 및 불상의 위상변천에 관한 분석을 중심으로 -)

  • Lee, Zu-Hyung;Jang, Suk-Ha
    • Journal of architectural history
    • /
    • v.20 no.1
    • /
    • pp.95-116
    • /
    • 2011
  • It is a true fact that the ancient Buddhist temples of Korea were great, important historical influence revealing the transition and developing stages of all the BUddhist temples in Eastern Asia including China and Japan. Before Mahayana arose within India, the monastery and pagoda were united during the conflict and development of the original Buddhism and pagoda faith. With the arising of Mahayana and the introduction of Buddhist statues, the Buddhist temple and pagoda were in conflict and resulted in separation. With the creation and development of the Mahayana Bodhisattva concept, Hinayana and Mahayana started to show doctrine differences and expressed each others' characteristics relevant to the structure of the temple. As a result, the Buddhist Temple having 1 pagoda spread in China together with Hinayana and Mahayana. The Buddhist temple of Hinayana had its temple and pagoda separated and the Buddhist temple that has a pagoda in front was divided into a form of 1 pagoda and 1 main temple. The temple and pagoda for Mahayana in the form of 1 pagoda and 2 temple, where the main statue of the Buddha may be worshipped from both the left and right hand sides, were separated in the form of 1 pagoda and 3 temples to have its original form again. Mahayana was first introduced into Goguryeo through the routes in the northern region and developed from having 1 pagoda and 2 temples, to having 1 pagoda and 3 temples. China was influenced by the southern regions, which is why Abhidharma was introduced into Baekje. Later on, the importance of Bodhisattva increased and the transition speed of the Buddhist temple having 1 pagoda and 3 temples accelerated, as Buddhism became more popular and as Mahayana flourished. The statue of the Buddha on both sides of the pagoda shall gradually move next to the central temple, and the temple shall form large crowds to not only form a tacit boundary with the pagoda but the expansion of Bodhisattva shall also have a wall or a corridor constructed in between the central, left and right hand side temples to form separate areas, and shall have a pagoda built in front of the temples that worship from both sides. In conclusion, independence shall exist among each Bodhisattva within the Buddhist temple, and the status of the pagoda shall fall and appear as the pagoda on both sides in front of the main Buddha statue.

Evaluation of Surcharge toads Acting in Backfilled Space (되메움 공간의 상재하중 영향평가에 관한 연구)

  • Moon Chang-Yeul;Kim Hee-Dong;Choi Heon
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.9
    • /
    • pp.167-176
    • /
    • 2004
  • Underground structures will be affected by the additional surcharge loads such as traffic load et al. Terzaghi (1956) suggested the equation on the influences of surcharge loads in vertically backfilled spaces. In field, the shapes of backfill spaces are not always formed vertically. Then the Terzagi (1956) equation is not suitable to use because of boundary condition. This study suggests equation to calculate the stress in backfilled space caused by surcharge loads when the backfilled space is sloped symmetrically. The suggested equation is verified by carbon box test and numerical analysis. The experimental results show good agreement with the suggested equation but the numerical analysis result shows a little disagreement. The differences are estimated to be caused by the fact that ground made by carbon rod has become more dense and internal frction and wall friction has increased itself as surcharge load is added but that this increase can not be considered in the numerical analysis. The suggested equation shows good agreement with Terzaghi (1956) equation in case of sloped backfill ground. According to the results, it is considered that the suggested equation can be applied not only to sloped space but also to vertical space. Further investigation using full scale experiment is needed.

Classification of Ground Subsidence Factors for Prediction of Ground Subsidence Risk (GSR) (굴착공사 중 지반함몰 위험예측을 위한 지반함몰인자 분류)

  • Park, Jin Young;Jang, Eugene;Kim, Hak Joon;Ihm, Myeong Hyeok
    • The Journal of Engineering Geology
    • /
    • v.27 no.2
    • /
    • pp.153-164
    • /
    • 2017
  • The geological factors for causing ground subsidence are very diverse. It can be affected by any geological or extrinsic influences, and even within the same geological factor, the soil depression impact factor can be determined by different physical properties. As a result of reviewing a large number of papers and case histories, it can be seen that there are seven categories of ground subsidence factors. The depth and thickness of the overburden can affect the subsidence depending on the existence of the cavity, whereas the depth and orientation of the boundary between soil and rock are dominant factors in the ground composed of soil and rock. In case of soil layers, more various influencing factors exist such as type of soil, shear strength, relative density and degree of compaction, dry unit weight, water content, and liquid limit. The type of rock, distance from the main fracture and RQD can be influential factors in the bedrock. When approaching from the hydrogeological point of view, the rainfall intensity, the distance and the depth from the main channel, the coefficient of permeability and fluctuation of ground water level can influence to ground subsidence. It is also possible that the ground subsidence can be affected by external factors such as the depth of excavation and distance from the earth retaining wall, groundwater treatment methods at excavation work, and existence of artificial facilities such as sewer pipes. It is estimated that to evaluate the ground subsidence factor during the construction of underground structures in urban areas will be essential. It is expected that ground subsidence factors examined in this study will contribute for the reliable evaluation of the ground subsidence risk.

The Estimation of Friction Velocity in an Open Channel by the Entropy Concept (엔트로피 개념을 활용한 개수로 마찰속도 산정)

  • Choo, Tai Ho;Son, Hee Sam;Yun, Gwan Seon;Noh, Hyun Seok;Ko, Hyun Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1533-1540
    • /
    • 2015
  • In order to demonstrate the flow properties of the river bed and the design of hydraulic structures, the estimation of friction velocity is essentially required. However, existing friction velocity equations such as Log method and Power law have trouble to estimate the friction velocity because a boundary condition and various hydraulic properties are changed constantly in near the wall. In the present study, therefore, a new friction velocity equation that can minimize the parameters and reduce an error was suggested. To verify accuracy and reliability for the proposed equation, Clauser method, $\sqrt{gRI}$ method, reynolds stress method by Dr. Song were compared with the proposed method by estimated entropy parameter M for each channel. Consequently, the results show that uniform flow condition as well as non-uniform flow condition with highly accuracy nearly matched in case of accelerating non-uniform condition of $R^2=0.9621$, Decelerating Non Uniform condition of $R^2=0.9274$, Uniform condition of $R^2=0.8865$.

Hypolipidemic and Anti-oxidant Effects of Chunghyl Plus in Type II Diabetic Mice Model (제2형 당뇨 마우스 모델에서 청혈플러스의 항고지혈 및 항산화효과)

  • Choi, Koh Eun;Seol, In Chan;Kim, Yoon Sik;Cho, Hyun Kyoung;Yoo, Ho Ryong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.3
    • /
    • pp.164-176
    • /
    • 2016
  • This study was perfomed to investigate the effects of Chunghyul-plus(CHP) on oxidative damage and hyperlipidemia in db/db mouse. After treatment with CHP, safety in cytotoxicity, heavy metal toxicity, production of reactive oxygen species(ROS), nitric oxide (N0) and proinflammatory cytokine IL-Ib, TNF-a, IL-6 in RAW 264.7 cells. Serum total cholesterol, LDL cholesterol, HDL cholesterol, triglyceride, insulin, GLP-1, glucose, food intake, body weight, organ weight, AST, ALT, ALP, BUN, creatine and histologic change of liver and aorta were measured in db/db mouse after oral administration of CHP. CHP showed safety in cytotoxicity and toxicity of liver and kidney for logn time administration. CHP increased the DPPH and ABTS radical scavenging activity. CHP showed significant inhibitory effect on reactive oxygen species (ROS), and showed inhibitory effect on nitiric oxide(NO) compared to control group. CHP decreased cytokine IL-6 production significantly, and decreased IL-1β and TNF-α compared to control group. CHP decreased body and organ weitht, intake food, and glucose levels compared to control group. CHP decreased total cholesterol and triglyceride significantly, and decreased LDL-cholesterol levels and increased HDL-cholesterol levels compared to control group. CHP decreased atherogenic index and cardiac risk factor significantly. CHP increased serum insulin and GLP-1 compared to control group. In histologic examination, lipophagy in the liver and aorta decreased in CHP treated mice and the cell was regular and boundary of vessel wall was clear compared to control group. These results suggest that CHP is effective in antioxidation activity and treatment and prevention of hyperlipidemia, atherosclerosis, diabetes, ischemic heart disease, stroke and other cardiocerebrovascular disease.

The heat transfer characteristics of viscoelastic non-newtonian fluids in the entrance region of circular tube flows (원형관속을 유동하는 점탄성 유체의 입구 영역 열전달 특성에 관한 연구)

  • 엄정섭;황태성;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.1032-1043
    • /
    • 1989
  • The heat transfer characteristics of the drag reducing polymer solutions are investigated experimentally in the thermal entrance region of circular tube flows. Fluids used in experiments are the aqueous solutions of high molecular polymer, polyacrylamide Separan AP-273 and the range of polymer concentrations is from 20 to 1000 wppm. Two stainless steel tubes with inside diameter 8.5mm(L/D=712) and 10.3mm(L/D=1160) are used for the heat transfer flow loops. The flow loop is set up to measure friction factors and heat transfer coefficients of test sections in two different modes; the recirculating flow system and once-through flow system. The test tubes are heated directly by electricity to apply the constant heat flux boundary conditions to the wall. Three different types of adaptors are used to observe the effects of the upstream flow conditions of the heat transfer test sections. The viscosity and characteristic relaxation time of the test fluids circulating in the flow system are measured by the capillary tube viscometer and falling ball viscometer at regular time intervals. The installed adaptors exhibit slight effect on the entrance heat transfer of Newtonian fluid. However, no noticeable effects are observed for the entrance heat transfer of the drag reducing fluids. The order of magnitude of the thermal entrance lengths of the drag reducing fluids which follow the minimum friction asymptote is much longer than that of Newtonian fluids in turbulent flows. A new dimensionless parameter, the viscoelastic Graetz number, is defined and all the experimental data are recasted in terms of the viscoelastic Graetz number. The local Nusselt number of the viscoelastic fluids is represented as a function of flow behavior index n and the viscoelastic Graetz number. As degradation continues the viscosity and the characteristic relaxation time of the testing fluids decrease. Weissenberg number defined by the relaxation time and D/V appears to be a proper dimensionless parameter in describing degradation effects on heat transfer of the viscoelastic fluids.

A Numerical Study on Heat Transfer and Flow Characteristics of a Finned Downhole Coaxial Heat Exchanger (외부유로 내벽에 설치된 핀 형상에 따른 이중관 열교환기의 열전달 및 유동에 대한 수치해석적 연구)

  • Park, Chun Dong;Lee, Dong Hyun;Park, Byung-Sik;Choi, Jaejoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.2
    • /
    • pp.79-86
    • /
    • 2017
  • In this study, the flow and heat transfer characteristics of the finned annular passage were investigated numerically. The annular passage simulates co-axial geothermal heat exchanger, and fins are installed on its inner wall to reduce heat loss from the production passage (annulus) to injection passage (inner pipe). A commercial CFD program, Ansys Fluent, was used with SST $k-{\omega}$ turbulence model. The effects of the geometric parameters of the fin on the inner tube were analyzed under the periodic boundary condition. The result indicated that most parameters had a tendency to increase with an increase in the height and angle of the fin. However, it was confirmed that the Nusselt number of the inner tube on the coaxial 15, 5, 0.3 was lower than that of the smooth tube. Additionally, the Nusselt number of the inner tube exhibited a tendency of decreasing with a decrease in the spacing in Coaxial 15, $S_f$, 0.3.

Application of Slip-line Method to the Evaluation of Plastic Zone around a Circular Tunnel (원형터널 주변의 소성영역 평가를 위한 slip-line 해석법 활용)

  • Lee, Youn-Kyou
    • Tunnel and Underground Space
    • /
    • v.32 no.5
    • /
    • pp.312-326
    • /
    • 2022
  • The generalized Hoek-Brown (GHB) criterion, which is recognized as one of the standard failure conditions for rock mass, is specialized for rock engineering applications and covers a wide range of rock mass conditions. Accordingly, many research efforts have been devoted to the incorporation of this criterion into the stability analysis of rock structures. In this study, the slip-line analysis method, which is a kind of elastoplastic analysis method, is combined with the GHB failure criterion to derive analytical equations that can easily calculate the plastic radius and stress distribution in the vicinity of the circular tunnel. In the process of derivation of related formulas, it is assumed that the behavior of rock mass after failure is perfectly plastic and the in-situ stress condition is hydrostatic. In the formulation, it is revealed that the plastic radius can be calculated analytically using the two respective tangential friction angles corresponding to the stress conditions at tunnel wall and elastic-plastic boundary. It is also shown that the plastic radius and stress distribution calculated using the derived analytical equations coincide with the results of Lee & Pietruszczak's numerical method published in 2008. In the latter part of this paper, the influence of the quality of the rock mass on the size of the plastic zone, the stress distribution, and the change of the tangential friction angle was investigated using the derived analytical equations.

Examination of Root Causes of Buckling in the Stern Structure of an Oil Tanker using Numerical Modeling (수치해석 모델링을 이용한 유조선 선미부 구조에 발생한 좌굴 발생 원인 검토)

  • Myung-Su Yi;Joo-Shin Park
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.7
    • /
    • pp.1259-1266
    • /
    • 2022
  • Recently, due to the specialization of structural design standards and evaluation methods, the classification rules are being integrated. A good example is the common international rules (CSR). However, detailed regulations are presented only for the cargo hold area where the longitudinal load is greatly applied, and no specific evaluation guidelines exist for the bow and stern structures. Structural design of the mentioned area is carried out depending on the design experience of the shipbuilder, and because no clear standard exists even in the classification, determining the root cause is difficult even if a structural damage problem occurs. In this study, an engineering-based solution was presented to identify the root cause of representative cases of buckling damage that occurs mainly in the stern. Buckling may occur at the panel wall owing to hull girder bending moment acting on the stern structure, and the plate thickness must be increased or vertical stiffeners must be added to increase the buckling rigidity. For structural strength verification based on finite element analysis modeling, reasonable solutions for load conditions, boundary conditions, modeling methods, and evaluation criteria were presented. This result is expected to be helpful in examining the structural strength of the stern part of similar carriers in the future.

An Estimation on the Applicability of Hollow FRP Soil Nailing System (중공식 FRP쏘일네일링 시스템의 적용성 평가)

  • Lee, Hyuk-Jin;Koh, Hyung-Seon;Han, Yong-Hee;Kim, Hong-Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6C
    • /
    • pp.385-393
    • /
    • 2006
  • Soil nailing is a reinforcement method used for stabilizing excavated walls or slopes. Due to its much advantages such as ease of construction and economical efficiency, use of soil nailing is increased. However, the soil nail has much disadvantages for use in urban area. The soil nail needs to be installed inevitably beyond private land boundary, which causes rent for use. For this reason, removable soil nailing system was developed. However, the removal rate of this system is just about 50¢¦70%. To resolve this problem, the Fiber Reinforced Plastic (FRP) soil nailing system which does not need to be removed and allows for the installation beyond private land, is developed. In this paper, through theoretical and experimental studies in laboratory and field such as prototype tests, pullout tests, we evaluate the stability and behavior characteristics of the FRP soil nailing system. And, numerical analyses using FLAC2D were performed with respect to various soil conditions, where prototype test for excavation wall and pullout tests were carried out. As a result of this study, the FRP soil nailing systems show similar behavior characteristics with those of removable soil nailing system. Finally, considering the serviceability and mechanical stability of FRP soil nailing systems, it is enough to be used as a good alternative of general soil nailing system.