• Title/Summary/Keyword: walking-induced vibration

Search Result 32, Processing Time 0.02 seconds

Vibration Reduction of Walking-type Cultivator's Handle using Modal Analysis and Operational Deflection Shapes Techniques (모드 해석과 운전 중 변형 형상 기법을 이용한 보행형 관리기의 핸들 진동 감소 방안)

  • 박영준;이윤세;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2004
  • The objectives of this study were to determine the natural frequency of a walking-type cultivator's handle using a modal analysis, to determine whether or not the handle resonates with forcing frequency induced by its engine, and to determine a method to reduce the handle vibration using a technique of the operational deflection shapes(ODS). Results of the study are as follows: The natural frequencies of the handle up to third harmonics were found to be 20.4, 22.5 and 92.1 Hz in the vertical direction and 14.9, 93, and 132 Hz in the horizontal direction. It was found that the handle does not resonate with the forcing frequency of the engine, which is 52 Hz. The operational deflection shape analysis revealed the deflected shapes of the handle in the vertical and horizontal directions and suggested that the handle vibration can be reduced by adding some mass to the place where the largest deflection occurs. Attaching of 1.1 kg mass adjacent to the largely deflected area resulted in reductions of vibration from 9.45 to 8.03 m/s$^2$ in x-axis direction from 3.89 to 3.16 m/s$^2$ in y-axis direction and from 7.89 to 3.09 m/s$^2$ in z-axis direction, which are respectively 15, 19 and 61% reductions. The total vibration level was reduced by 29%, indicating that mass-adding method by the ODS is very effective for reducing the handle vibrations of the cultivators.

A simplified method for determining the acceleration amplitudes of long-span floor system under walking/running loads

  • Cao, Liang;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • v.75 no.3
    • /
    • pp.377-387
    • /
    • 2020
  • Modern long-span floor system typically possesses low damping and low natural frequency, presenting a potential vibration sensitivity problem induced by human activities. Field test and numerical analysis methods are available to study this kind of problems, but would be inconvenient for design engineers. This paper proposes a simplified method to determine the acceleration amplitudes of long-span floor system subjected to walking or running load, which can be carried out manually. To theoretically analyze the acceleration response, the floor system is simplified as an anisotropic rectangular plate and the mode decomposition method is used. To facilitate the calculation of acceleration amplitude aP, a coefficient αwmn or αRmn is introduced, with the former depending on the geometry and support condition of floor system and the latter on the contact duration tR and natural frequency. The proposed simplified method is easy for practical use and gives safe structural designs.

Efficient Analysis of Structure Vibration Induced by Walking Loads (보행하중에 의한 구조물 진동의 효율적인 해석)

  • 김기철;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.21-29
    • /
    • 2001
  • 주차장, 버스터미널, 스타디움, 집회공간과 같은 낮은 고유진동수를 갖는 장경간 건축물에서는 저속 차량의 이동하중이나 보행자의 보행하중과 같은 동적하중에 의해 과도한 바닥판 진동이 발생할 수 있으며 이러한 진동은 건축물의 이용자에게 불쾌감을 일으켜 건축물의 사용성에 심각한 영향을 주게된다. 구조물에 가해지는 보행하중의 일반적인 적용방법은 분할된 요소의 절점을 따라 절점하중으로 가하는 것이다. 그러나 이러한 해석모델은 보행하중을 절점에만 가해야하는 제한적인 문제점을 가지고 있어 보폭 수만큼 절점을 생성시켜야 하며 보폭이 변하거나 절점이외에 하중이 작용할 경우 해석모델을 수정해야하는 번거로움이 있다. 본 연구에서는 보행하중에 대한 계측과 분석을 통하여 보행하중의 동적특성을 분석하였으며 계측한 보행하중을 예제구조물에 적용하였다. 그리고 보행하중에 의한 구조물 진동의 효율적인 해석을 위하여 구조물에 가해지는 보행하중을 등가의 절점하중으로 치환하는 방법을 제안하였으며 제안된 등가절점 하중의 타당성을 검증하기 위하여 예제구조물의 진동해석을 수행하였다.

  • PDF

Serviceability Evaluation of Sky Bridge With Isolation Device (면진장치 장착 스카이 브릿지의 사용성 평가)

  • Kim, Gee-Cheol;Kim, Hyun-Su;Kim, Su-Geun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.71-77
    • /
    • 2017
  • In this study, the boundary non-linear analysis of the sky bridge subjected to walking load and running load is performed. The sky bridge is installed in the mid-story between two buildings and the walking load and running load induced by pedestrians are measured by load cell. LRB is modeled as a non-linear hysteresis model to accurately represent the behavior of LRB. For the serviceability evaluation of sky bridge, the acceleration responses of sky bridge are analyzed based on ISO 2631-2 and the velocity response are analyzed based on standards Bachmann &Amann. In serviceability evaluation of this sky bridge, the pedestrian can not perceive the vibration except for resonance running loads consequently. Therefore, it is concluded that this sky bridge haven't problem in the serviceability.

Measurements of pedestrian's ioad using smartphones

  • Pan, Ziye;Chen, Jun
    • Structural Engineering and Mechanics
    • /
    • v.63 no.6
    • /
    • pp.771-777
    • /
    • 2017
  • The applications of smartphones or other portable smart devices have dramatically changed people's lifestyle. Researchers have been investigating useage of smartphones for structural health monitoring, earthquake monitoring, vibration measurement and human posture recognition. Their results indicate a great potential of smartphones for measuring pedestrian-induced loads like walking, jumping and bouncing. Smartphone can catch the device's motion trail, which provides with a new method for pedestrain load measurement. Therefore, this study carried out a series of experiments to verify the application of the smartphone for measuring human-induced load. Shaking table tests were first conducted in order to compare the smartphones' measurements with the real input signals in both time and frequency domains. It is found that selected smartphones have a satisfied accuracy when measuring harmonic signals of low frequencies. Then, motion capture technology in conjunction with force plates were adopted in the second-stage experiment. The smartphone is used to record the acceleration of center-of-mass of a person. The human-induced loads are then reconstructed by a biomechanical model. Experimental results demonstrate that the loads measured by smartphone are good for bouncing and jumping, and reasonable for walking.

Performance Evaluation of Vertical Vibration of Precast Concrete Slabs (프리캐스트 콘크리트 바닥판의 수직진동 허용치 평가)

  • Heo, Seok-Jae;Lee, Sang-Hyun;Cho, Seung-Ho;Chung, Lan;Kim, Sung-Bae;Park, Sung-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.662-667
    • /
    • 2009
  • In this study, the serviceability of Waffle shaped(WAS) and Double-Tee(DT) precast concrete slabs was evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures (a shopping mall in Hanam) of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan), and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and the maximum acceleration level of WAS slabs was lower than that of DT slabs.

  • PDF

VSimulators: A New UK-based Immersive Experimental Facility for Studying Occupant Response to Wind-induced Motion of Tall Buildings

  • Antony Darby;James Brownjohn;Erfan Shahabpoor;Kaveh Heshmati
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.347-362
    • /
    • 2022
  • Current vibration serviceability assessment criteria for wind-induced vibrations in tall buildings are based largely on human 'perception' thresholds which are shown not to be directly translatable to human 'acceptability' of vibrations. There is also a considerable debate about both the metrics and criteria for vibration acceptability, such as frequency of occurrence or peak vs mean vibration, and how these might vary with the nature of the vibration. Furthermore, the design criteria are necessarily simplified for ease of application so cannot account for a range of environmental, situational and human factors that may enhance or diminish the impact of vibrations on serviceability. The dual-site VSimulators facility was created specifically to provide an experimental platform to address gaps in understanding of human response to building vibration. This paper considers how VSimulators can be used to inform general design guidance and support design of specific buildings for habitability, in terms of vibration, which allow engineers and clients to make informed decisions with regard to sustainable design, in terms of energy and financial cost. This paper first provides a brief overview of current vibration serviceability assessment guidelines, and the current understanding and limitations of occupants' acceptability of wind-induced motion in tall buildings. It then describes how the dual-site VSimulators facility at the Universities of Bath and Exeter can be used to assess the effects of motion and environment on human comfort, wellbeing and productivity with examples of how the facility capabilities have been used to provide new, human experience based experimental research approaches.

Optimal Design of an Auto-Leg System for Washing Machines (세탁기용 자동신통저감장치($Auto-Leg^{TM}$)의 최적 설계)

  • Seo, H.S.;Lee, T.H.;Jeon, S.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.996-1001
    • /
    • 2006
  • Automatic washing machines have been improved and popularized steadily since the first electric washing machine was produced in the early 1900's. Appliance industry has tried to obtain the performance of washing machine with large capacity, high energy efficiency, low vibration and low noise levels. As the installation peace of a washer becomes closer to the living space, vibration and noise problems become more important challenges. In general, a washing machine has four legs to support its body. Four legs of the washing machine should be attached on a floor. If not so, it may cause severe vibration or walking in the spin-drying process. Unfortunately, the floor of an ordinary house is bumpy in general, and the consumers will not accept bolting washing machines to a foundation; moreover, sometimes they move the location of their washing machines to utility rooms or bath rooms or kitchens and don't care for leveling the legs exactly. In this study, we devise an auto-leg system that prevents the occurrence of abnormal vibration and walking of washing machines. It is simply composed of a spring and a friction damper. Some experiments are implemented to show the dynamic characteristics of the three-dimensional auto-legged washing machine model that is located on the even or uneven ground. A spring parameter is optimized to adjust the length of the auto-leg system automatically up to 10 mm irregularity, and the friction damper is designed to decrease a resonance induced by the spring of the auto-leg system. Some numerical results show that placing the proposed auto-leg system in a washing machine makes good performance with low vibration, as well as low noise, regardless of the unevenness of the floor.

  • PDF

Comparison of Performance of the Exciter and Impact Hammer Test for Dynamic Characteristics Analysis of Floor Slabs (건물바닥 슬래브의 동특성 분석을 위한 가진기와 Impact Hammer의 성능 비교)

  • Ahn, Sang-Kyung;Moon, Yeong-Jong;Oh, Jung-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.117-120
    • /
    • 2007
  • The floor slabs of building structures are often subjected to the periodic force which is induced by vibrating machines or human activity(walking, jumping, running etc). These periodic forces cause excessive oscillation. In order to examine the dynamic characteristics of floor slabs, the dynamic characteristics test is accomplished. Generally, the Impact Hammer and Dynamic Exciter test is used to dynamic characteristics test. But the Impact Hammer test is not suitable to apply in building slabs. In this paper, It compared the performance of the Exciter and Impact Hammer test for dynamic characteristics analysis of floor slabs.

  • PDF

Conditions to avoid synchronization effects in lateral vibration of footbridges

  • Andrade, Alexandre R.;Pimentel, Roberto L.;Silva, Simplicio A. da;Souto, Cicero da R.
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.2
    • /
    • pp.201-220
    • /
    • 2022
  • Lateral vibrations of footbridges may induce synchronization between pedestrians and structure itself, resulting in amplification of such vibrations, a phenomenon identified by lock-in. However, investigations about accelerations and frequencies of the structural movement that are related to the occurrence of synchronization are still incipient. The aim of this paper is to investigate conditions that could lead to avoidance of synchronization among pedestrians themselves and footbridge, expressed in terms of peak acceleration. The focus is on the low acceleration range, employed in some guidelines as a criterion to avoid synchronization. An experimental campaign was carried out, employing a prototype footbridge that was set into oscillatory motion through a pneumatic exciter controlled by a fuzzy system, with controlled frequency and amplitude. Test subjects were then asked to cross the oscillating structure, and accelerations were simultaneously recorded at the structure and at the subject's waist. Pattern and phase differences between these signals were analysed. The results showed that test subjects tended to keep their walking patterns without synchronization induced by the vibration of the structure, for structural peak acceleration values up to 0.18 m/s2, when frequencies of oscillation were around 0.8 to 0.9 Hz. On the other hand, for frequencies of oscillation below 0.7 Hz, structural peak accelerations up to 0.30 m/s2 did not induce synchronization.