• 제목/요약/키워드: w-finite type

검색결과 172건 처리시간 0.025초

Electromagnetic Behavior of High -$T_c$ Superconductors underthequenchstate -

  • 정동철;최효상;황종선;윤기웅;한병성
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.183-187
    • /
    • 2002
  • In this paper we analyzed the electromagnetic behavior of high $-T_{c}$ superconductor under the quench state using finite element method. Poisson equation was used in finite element analysis as a governing equation and was solved using algebra equation using Gallerkin method. We first investigate d the electromagnetic behavior of U-type superconductor. Finally we applied our analysis techniques to 5.5 kVA meander-line superconducting fault current limiters (SFCL) which are currently developed by many power-system researcher in the world. Meshes of 14,600 elements were used in analysis of this SFCL. Analysis results show that the distribution of current density was concentrated to inner curvature in meander-line type-superconductors and maximum current density 14.61 $A/\m^2$ and also maximum Joule heat was 6,420 W/㎥. We concluded that this meander line-type SFCL was not pertinet fur uniform electromagnetic field distribution.n.

  • PDF

A NEW CHARACTERIZATION OF PRÜFER v-MULTIPLICATION DOMAINS

  • CHANG, GYU WHAN
    • Korean Journal of Mathematics
    • /
    • 제23권4호
    • /
    • pp.631-636
    • /
    • 2015
  • Let D be an integral domain and w be the so-called w-operation on D. In this note, we introduce the notion of *(w)-domains: D is a *(w)-domain if $(({\cap}(x_i))({\cap}(y_j)))_w={\cap}(x_iy_j)$ for all nonzero elements $x_1,{\ldots},x_m$; $y_1,{\ldots},y_n$ of D. We then show that D is a $Pr{\ddot{u}}fer$ v-multiplication domain if and only if D is a *(w)-domain and $A^{-1}$ is of finite type for all nonzero finitely generated fractional ideals A of D.

동축전송선로에 연결된 도파관형 소자의 입력 임피던스 해석 (Input impedance analysis of the coaxial to W/G type devices)

  • 이평화;천창율;신판석
    • 전자공학회논문지D
    • /
    • 제34D권11호
    • /
    • pp.9-19
    • /
    • 1997
  • By noticing that most waveguide devices were connected to power source through coaxial line, three dimentional finite element analysis using TEM mode incident was tried. When tEM mode was used, being dissimilar to TE$_{10}$ mode incident, analysis model of TEM mode incident has almost the same geometry with real products. Therefore, the degree of trust about analysis result is improved. Reflection coefficients of coaxial line, W/G adaptor, magnetron obtained by simulation was compared with experimental results.

  • PDF

EQUIVALENCES OF SUBSHIFTS

  • Lee, Jung-Seob
    • 대한수학회지
    • /
    • 제33권3호
    • /
    • pp.685-692
    • /
    • 1996
  • Subshifts of finite type can be classified by various equivalence relations. The most important equivalence relation is undoubtedly strong shift equivalence, i.e., conjugacy. In [W], R. F. Williams introduced shift equivalence which is weaker than conjugacy but still sensitive.

  • PDF

1.5kW급 풍력발전용 축자속/반경자속 영구자석 발전기의 특성 비교 (Characteristics Comparison of Axial and Radial Flux Permanent Magnet Generators for 1.5kW Class Wind Power Systems)

  • 고경진;장석명;구민모;이성호;한상철;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1075-1076
    • /
    • 2011
  • This paper compares performance characteristics and mechanical design specifications of outer rotor radial flux type and double-sided axial flux type permanent magnet generator for 1.5-kW class small scale wind power applications to suggest most suitable type. In order to analyze electromagnetic performances of two different type generators, this paper performs generating performance and efficiency characteristic analysis from electrical parameters obtained by using nonlinear finite element analysis using commercial software, electromagnetic losses characteristics equations and d-q characteristics equation. Considering the derived electromagnetic performance, mechanical design specifications and manufacturing cost, the best suitable model for 1.5-kW class wind power system is determined, and its experiment was performed to validate the suggested analysis method.

  • PDF

평판형 선형 초음파 모터의 시작 (Fabrication of Plate-Type Linear Ultrasonic Motor)

  • 이종섭;정수현;이강원;임기조;김영욱;임태빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1534-1536
    • /
    • 1998
  • We designed and fabricated plate-type linear ultrasonic motor. It used multi-vibration mode, 1st Longitudinal and 4th Bending mode. To analyze vibration mode and find maximum displacement point, we simulated using FEM(Finite Element Method). The plate-type linear ultrasonic motor was fabricated by the simulation results. Also, to confirm application to card-forwarding device, frequency and load characteristics were measured. Its resonance frequency was 49.6 kHz, and its maximum speed was about 0.6m/s when no load. Also, its maximum efficiency was 1.2 % and in that time, speed and torque was 0.3 m/s and 0.7 mNm, respectively.

  • PDF

토크비 개선을 위한 자속 장벽형 회전자 구조 동기 릴릭턴스 전동기의 설계 (Design of Flux Barrier type Synchronous Reluctance Motor to improve Saliency Ratio)

  • 장석명;박병임;이성호;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.660-662
    • /
    • 2000
  • It is demonstrated that the torque performance of the flux barrier type synchronous reluctance motor(SynRM) can be improved in terms of geometric parameters. Torque ana power factor are related to the difference of inductances and the saliency ratio. And these inductance characteristics are determined by the geometric parameters of rotor: the number of layers. the width of iron to the width of flux barrier($K_w$). slot number and shape, airgap, bridge, etc. The relationship between geometric parameters. especially, $K_w$ and motor performance will be studied. This paper shows that torque and power factor are improved through redesign with considering geometric parameters. Performance comparisons of proto type SynRM and improved SynRM are given by FEA(Finite Element Analysis).

  • PDF

Locker 의 물림각이 쐐기형 레일클램프의 압착력에 미치는 영향 평가 (The Effect of Clamping Angle of a Locker on the Clamping Force of the Wedge Type Rail Clamp)

  • 한동섭;이성욱;한근조;안찬우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.1042-1045
    • /
    • 2005
  • The wedge type rail clamp has the operating mechanism: First, the jaw pad clamps a rail with small clamping force. Next as the wind speed increases, the clamping force of the Jaw pad Is Increased by the wedge. The initial clamping force of a jaw pad was determined by the clamping angle of a locker. In this study, we carried out the finite element analysis to evaluate the relationship between the clamping angle of a locker and the clamping force of a jaw pad with respect to the design wind speed, such as 2, 4, 6, 8, and 10m/s, we adopted the wedge type rail clamp fur 50tons class container crane with the wedge angle of $10^{\circ}$.

  • PDF

유한요소법을 이용한 공기 순환 방식의 골프화 설계에 관한 연구 (1Analysis of Outsole in Golf shoes by using Finite Element Method)

  • 송우진;김용욱;문병영;강범수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.224-228
    • /
    • 2001
  • This paper presents the analyzing method of golf shoes and shows design technique including air-cycled pump in the midsole. The golf shoes are analyzed by using the finite element method for the optimization in design by considering the configuration of midsole and outsole, which compose the golf shoes. Also the optimum size of air-cycled pump in the midsole is examined. Standard human pressure values for boundary conditions are adoped for the finite element analysis. The unknown constants of the strain energy function of Ogden type are observed in accordance with the axial tension test. By using the commercial FEM software for nonlinear analysis, MARC V7.3, the strains and the values of volume change for midsole and outsole are obtained, respectively. As a result, it can be concluded that these values in the midsole and the outsole are different depending on the characteristic of elastomer. More precise investigation about the assembly of two parts, which represent midsole and outsole, is under studying.

  • PDF

Spring rod를 사용한 척추경 나사못과 동반 시술된 Flexible cage의 생체역학적 효과 (Biomechanical Efficacy of a Combined Flexible Cage with Pedicle Screws with Spring rods: A Finite Element Analysis)

  • 김영현;박은영;김원현;황성필;박경우;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권1호
    • /
    • pp.9-15
    • /
    • 2017
  • Recently, flexible cages have been introduced in an attempt to absorb and reduce the abnormal load transfer along the anterior parts of the spine. They are designed to be used with the pedicle screw systems to allow some mobility at the index level while containing ROM at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the flexible cage when combined with pedicle screws with flexible rods. The post-operated models were constructed by modifying the L4-5 of a previously-validated 3-D FE model of the intact lumbar spine (L2-S1): (1) Type 1, flexible cage only; (2) Type 2, pedicle screws with flexible rods; (3) Type 3, interbody fusion cage plus pedicle screws with rigid rods; (4) Type 4, interbody fusion cage plus Type 2; (5) Type 5, Type 1 plus Type 2. Flexion/extension of 10 Nm with a compressive follower load of 400N was applied. As compared to the Type 3 (62~65%) and Type 4 (59~62%), Type 5 (53~55%) was able to limit the motion at the operated level effectively, despite moderate reduction at the adjacent level. It was also able to shift the load back to the anterior portions of the spine thus relieving excessively high posterior load transfer and to reduce stress on the endplate by absorbing the load with its flexible shape design features. The likelihood of component failure of flexble cage remained less than 30% regardless of loading conditions when combined with pedicle screws with flexible rods. Our study demonstrated that flexible cages when combined with posterior dynamic system may help reduce subsidence of cage and degeneration process at the adjacent levels while effectively providing stability at the operated level.