• Title/Summary/Keyword: volume measurement

Search Result 1,615, Processing Time 0.031 seconds

Carburization Characteristics of MERT Type KHR-45A Steel in Carbon Rich Environment (Carbon Rich 분위기에서의 KHR45강의 침탄특성 평가 연구)

  • Lim, Jae Kyun;Yang, Gimo;Ihm, Young Eon
    • Korean Journal of Materials Research
    • /
    • v.23 no.5
    • /
    • pp.293-298
    • /
    • 2013
  • In this study, an HP-mod. type(KHR-45A), which is used as a heater tube material in the pyrolysis process, was evaluated for its carburizing properties. It was confirmed from the microstructural observation of the tubes that the volume fraction of carbide increased and that the coarsening of Cr-carbide generated as a degree of carburization increased. The depth of the hardened layer, which is similar to the thickness of the carburized region of each specimen, due to carburization is confirmed by measurement of the micro-Vickers hardness of the cross section tube, which thickness is similar to that of the carburized region of each specimen. Two types of chromium carbides were identified from the EBSD (electron back-scattered diffraction) image and the EDS (energy-dispersive spectroscopy) analysis: Cr-rich $M_{23}C_6$ in the outer region and Cr-rich $M_7C_3$ in the inner region of tubes. The EDS analysis revealed a correlation between the ferromagnetic behavior of the tubes and the chromium depletion in the matrix. The chromium depletion in the austenite matrix is the main cause of the magnetization of the carburized tube. The method used currently for the measurement of the carburization of the tubes is confirmed; carburizing evaluation is useful for magnetic flux density measurement. The volume fraction of the carbide increased as the measuring point moved into the carburized side; this was determined from the calculation of the volume fraction in the cross-section image of the tubes. These results are similar to the trends of carburization measurement when those trends were evaluated by measurement of the magnetic flux density.

Evaluate the usefulness of Coincidence Summing Correction Factors for Cylinder and Extended Source Penelope Simulation (실린더 및 확장 소스 PENELOPE 시뮬레이션에 대한 동시합성보정 계수 유용성 평가)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.821-831
    • /
    • 2021
  • In order to calibrate energy and efficiency using the PENELOPE Code, a PENELOPE simulation was performed using a volume source. Here, we want to verify peak efficiency and usefulness by performing simultaneous measurement and correction. calculate the coincident sum correction for all volumes, first subdivide the volumes of the cylinder and the four Marinelli beakers into three heights again. Therefore, the simultaneous measurement correction coefficient in three areas and the simultaneous measurement correction coefficient for the entire volume source are calculated as output. At low energies, the j value for each source volume (50-300 ml) is small and increases significantly in the high energy range. Simulation results showed good agreement within 2.5% for all source volumes except for 50 ml and 300 ml, which were up to 4%. This means that the correction for the simultaneous measurement effect during measurement is effective. In addition. Based on this, it can be confirmed that there is an advantage to improve the detection efficiency when measuring various sources and environmental samples.

Measurement of Mechanical-acoustic Transfer Functions of Vehicles by Combination of Mechanical and Acoustic Excitations (구조가진과 음향 가진의 결합에 의한 차량의 구조-음향 전달 함수 측정)

  • 고강호;이장무
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.9
    • /
    • pp.158-164
    • /
    • 1999
  • In this paper a simple measurement technique for mechanical-acoustic transfer functions is proposed . The mechanical-acoustic transfer functions, generally , are measured through mechanical excitations ; impact hammers or shakers. Recently , by virtue of vibro-acoustical reciprocity principle, they are measured through acoustic excitations : loudspeakers. This kind of test needs to measure the volume velocity , the radiation characteristics of a sound source. Because the volume velocity of the sound source is changed by driving signal , it is difficult to measure it. However , the new method in this paper needs not to measure the volume velocity of a sound source by combination of mechanical and acoustic excitations. Moreover, this method has the methodological advantages, such as usage of a general loudspeaker for the reciprocal excitation, no sptatial limitations for measurements of mechanical-acoustic transfer functions.

  • PDF

The Development of Ultrasonic Transducer for Measurement of Urine Volume in Incontinence Preventive System (뇨실금 방지 시스템에서의 뇨량 측정을 위한 초음파 변환기의 개발)

  • Choi, Heung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.5 s.305
    • /
    • pp.35-42
    • /
    • 2005
  • In this study, we designed and developed an ultrasonic transducer which can measure urine volume based on the estimation of distance between the interior-wall and posterior-wall of bladder. Measurement of urine volume is a way to help patients with urinary incontinence by detecting the amount of urine before the urine is released from the bladder. With the results of this experiment, we can measure the urine volume more accurately and also develop an incontinence preventive system. This study can help patients with urinary incontinence and enuresis to live longer, healthier lives.

The Effects of Training on the Proper Use of Respiratory Rate Measurement Devices for Providing High-Quality Artificial Ventilation

  • Jae-Ran Lim;Sung-Hwan Bang;Hyo-Suk Song;Gyu-Sik Shim;Ho-Jin Park
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.165-171
    • /
    • 2024
  • This study aims to investigate the appropriate volume of artificial ventilation and success rate when Basic - emergency medical Technician administer bag valve mask(BVM) artificial ventilation to patients experiencing respiratory failure or respiratory arrest using a respiratory rate measurement device. The research was conducted from December 11th to 12th, 2023, targeting 20 Basic - emergency medical Technicians enrolled at D University. Ten participants were selected for the experimental group, receiving BVM ventilation training with the use of a respiratory rate measurement device, while the other ten were assigned to the control group, receiving BVM ventilation training without the use of a respiratory rate measurement device. The experiment involved providing artificial ventilation for 2 minutes. The results of the study indicated that the control group did not provide accurate tidal volume (p=.025). The experimental group demonstrated a higher success rate of ventilation over the 2-minute period, while the control group showed a significant difference (p=.001). Subjective perception of tidal volume and objectively measured tidal volume also exhibited a significant difference in the control group (p=.010). Therefore, training with a respiratory rate measurement device can align the subjective perception of tidal volume with objective measurements, increase the success rate of ventilation, and potentially contribute to improving survival rates in patients experiencing respiratory failure or respiratory arrest during cardiopulmonary resuscitation.

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF

Estimation Algorithm for Portable Bladder Volume Measurement System (휴대용 방광용적 측정 시스템을 위한 추정 알고리듬 연구)

  • 하재규;송무용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.10-16
    • /
    • 2000
  • A new algorithm for estimating bladder volume for portable bladder volume measurement system is proposed. Given the actual image of a bladder, edges between bladder wall and urine are extracted first. Axes are calculated from these data and actual cross section shape is obtained by filtering. Since ordinary shape of a bladder is irregular, two cross-sections(transverse and longitudinal) are considered. With the area of a longitudinal cross-section projected along the axes of transverse cross-section, or vice versa, two estimated volume are obtained. Averaging these two value yields the volume of the bladder. Applied to actual experiments, the proposed algorithm showed explicitly good results in comparison with the conventional techniques.

  • PDF

Research on the characteristics of noise exposure on worker wearing acoustic devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.808-813
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset Noise exposure measurements of 17 operators were performed in 7 call centers and Head and Torso Simulator method in compliance with the ISO Standard 11904-2 was used for the measurement of noise transmitted from the headset Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of Pearson Correlation Analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

  • PDF

Shape, Volume Prediction Modeling and Identical Weights Cutting for Frozen Fishes (동결생선의 외형과 부피 예측 모델링 및 정중량 절단)

  • Hyun, Soo-Hwan;Lee, Sung-Choon;Kim, Kyung-Hwan;Seo, Ki-Sung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.3
    • /
    • pp.294-299
    • /
    • 2012
  • This paper suggests a modeling technique for shape and volume prediction of fishes to cut them with identical weights for group meals. The measurement and prediction of frozen fishes for group meals are very difficult because they have a bending deformation occurring at frozen stage and a hollow by eliminating the internals. Besides there exist twinkles problem of surface caused by freeze and variable weights by moisture conditions. Therefore a complex estimation algorithm is necessary to predict the shape and volume prediction of fishes exactly. Hollow prediction, pattern classification and modeling for tails using neural network, integration based volume prediction algorithm are suggested and combined to solve those problems. In order to validate the proposed method, the experiments of 3-dimensional measurement, volume prediction and fish cutting for spanish mackerel, saury, and mackerel are executed. The cutting experiments for real fish are executed.