• Title/Summary/Keyword: volume measurement

Search Result 1,615, Processing Time 0.028 seconds

Accuracy Improvement of Breast Volume Estimation Using Length Parameters of Breast (유방에 대한 길이 파라미터를 이용한 3차원 유방 부피의 예측 개선)

  • Lee, Hyun-Young;Hong, Kyung-Hi
    • The Research Journal of the Costume Culture
    • /
    • v.14 no.5
    • /
    • pp.840-849
    • /
    • 2006
  • Breast volume has been approximately estimated under the assumption that the shape of breast is a corn. However, women's breast is more like a bulged bag in reality. In this paper, three methods of breast volume estimation were compared to find out the more accurate method. The shape of the breast is assumed as a hemisphere in the first estimation method and a corn in the second one. In the third method, arc along the cross sectional shape of breast was utilized in the calculation. Comparisons among the methods were made using the actual 3D volume measurement of thirty seven women's breast. As results, the third method was the best one for the normal breast type, especially for the lower part of the breast ($R^2=0.74$) which is the crucial design parameter of the brassiere. Assumption of the shape of breast as a corn was reasonably acceptable when the breast is sagged. It was expected that when women wore brassiere, the accuracy of the third method would increase more, since the shape of breast becomes more symmetrical.

  • PDF

A Study on the Classification of Brassiere Cups by Breast Volume Measurement Values on Women in their Twenties (20대 여성의 유방 부피 계측치에 따른 브래지어 컵의 분류)

  • Park, Yu-Sin;Kim, Seon-Mi;Kim, Eun-Ran
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.2
    • /
    • pp.93-104
    • /
    • 2004
  • The research subjects of this study were 30 unmarried Korean women from 20 to 29 who had never had an operation on their breast. Measurement method using plaster breast mold was used for measuring their volume of breast. The correlation between their breast volume and the methods to set up brassiere cups with the existing method and with their circumference of breast was analyzed using KendalI's Coefficient. which was to figure out a method which had a bigger correlation with the volume of breast between the method to set up brassiere cups using the existing method and the method using the circumference of breast. The results analyzed showed that the coefficient of correlation between the existing method and the volume of breast was .12 and the significance level was .45. They didn't have any correlation. On the other hand. the coefficient of correlation between the circumference of breast and the volume of breast was .82. which was very high values and the significance level was very high .0001. Therefore. it turned out that it was difficult to set up brassiere cups by using the existing method and it was easier and more reliable to set up the cups by using the circumference of breast.

Volume Resistivity, Specific Heat and Thermal Conductive Properties of the Semiconductive Shield in Power Cables

  • Lee Kyoung-Yong;Choi Yong-Sung;Park Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.89-96
    • /
    • 2005
  • To improve the mean-life and reliability of power cables, we have investigated the volume resistivity and thermal properties demonstrated by changing the content of carbon black, an additive of the semiconductive shield for underground power transmission. Nine specimens were made of sheet form for measurement. Volume resistivity of the specimens was measured by a volume resistivity meter after 10 minutes in a preheated oven at temperatures of both 25$\pm$1[$^{\circ}C$] and 90$\pm$ 1[$^{\circ}C$]. As well, specific heat (Cp) and thermal conductivity were measured by Nano Flash Diffusivity and DSC (Differential Scanning Calorimetry). The ranges of measurement temperature were from 0[$^{\circ}C$] to 200[$^{\circ}C$], and heating temperature was 4[$^{\circ}C$/min]. From these experimental results, volume resistivity was high according to an increase of the content of carbon black. Specific heat was decreased, while thermal conductivity was increased according to a rise in the content of carbon black. Furthermore, both specific heat and thermal conductivity were increased by heating temperature because the volume of materials was expanded according to a rise in temperature.

Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

Selective Segmentation of 3-D Objects Using Surface Detection and Volume Growing (표면 검출과 볼륨 확장을 이용한 삼차원 물체의 선택 분할)

  • Bae, So-Young;Choi, Soo-Mi;Choi, Yoo-Joo;Kim, Myoung-Hee
    • The KIPS Transactions:PartA
    • /
    • v.9A no.1
    • /
    • pp.83-92
    • /
    • 2002
  • The segmentation of target objects from three dimensional volume images is an essential step for visualization and volume measurement. In this paper, we present a method to detect the surface of objects by improving the widely used levoy filtering for volume visualization. Using morphological operators we generate completely closed surfaces and selectively segment objects using the volume growing algorithm. The presented method was applied to 3-D artificial sphere images and angiocardiograms. We quantitatively compared this method with the conventional levoy filtering using artificial sphereimages, and the results showed that our method is better in the aspect of voxel errors. The results of visual comparison using angiocardiograms also showed that our method is more accurate. The presented method in this paper is very effective for segmentation of volume data because segmentation, visualization and measurement are frequently used together for 3-D image processing and they can be easily related in our method.

Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison with Cardiac MRI: A Meta-Analysis

  • Jin Young Kim;Young Joo Suh;Kyunghwa Han;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.450-461
    • /
    • 2020
  • Objective: We performed a meta-analysis to evaluate the agreement of cardiac computed tomography (CT) with cardiac magnetic resonance imaging (CMRI) in the assessment of right ventricle (RV) volume and functional parameters. Materials and Methods: PubMed, EMBASE, and Cochrane library were systematically searched for studies that compared CT with CMRI as the reference standard for measurement of the following RV parameters: end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), or ejection fraction (EF). Meta-analytic methods were utilized to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT and CMRI. Heterogeneity was also assessed. Subgroup analyses were performed based on the probable factors affecting measurement of RV volume: CT contrast protocol, number of CT slices, CT reconstruction interval, CT volumetry, and segmentation methods. Results: A total of 766 patients from 20 studies were included. Pooled bias and LOA were 3.1 mL (-5.7 to 11.8 mL), 3.6 mL (-4.0 to 11.2 mL), -0.4 mL (5.7 to 5.0 mL), and -1.8% (-5.7 to 2.2%) for EDV, ESV, SV, and EF, respectively. Pooled correlation coefficients were very strong for the RV parameters (r = 0.87-0.93). Heterogeneity was observed in the studies (I2 > 50%, p < 0.1). In the subgroup analysis, an RV-dedicated contrast protocol, ≥ 64 CT slices, CT volumetry with the Simpson's method, and inclusion of the papillary muscle and trabeculation had a lower pooled bias and narrower LOA. Conclusion: Cardiac CT accurately measures RV volume and function, with an acceptable range of bias and LOA and strong correlation with CMRI findings. The RV-dedicated CT contrast protocol, ≥ 64 CT slices, and use of the same CT volumetry method as CMRI can improve agreement with CMRI.

Measurement Uncertainty for Analytical Method of Hyaluronic Acid Used as a Dietary Supplement (식이보충제로 사용되는 히알루론산의 분석법에 대한 불확도 산정)

  • Park, Sang-Wook;Kim, Hyung Bum;Kim, Kwang Joon;Lee, Wonjae
    • KSBB Journal
    • /
    • v.32 no.1
    • /
    • pp.54-62
    • /
    • 2017
  • This study aimed to estimate the measurement uncertainty related to determination of hyaluronic acid used as a dietary supplement by high-performance liquid chromatography. According to the guidelines of the Association of Official Analytical Chemists, the analytical processes for determination of hyaluronic acid were performed. And the measurement uncertainty obtained during the analytical processes were expressed in accordance with mathematical/ statistical guidances of GUM (Guide to the Expression of Uncertainty in Measurement) & EURACHEM (Focus for Analytical Chemistry in Europe) for the analytical operations. For the uncertainty in measurement produced based on this analytical method, the expanded uncertainty was calculated by using the relative standard uncertainty between analytical results and sources of uncertainty in measurement (sample weight, final volume, extraction volume, standard solution, matrix and instrument etc). In the results of 95% confidence interval, it was calculated that the uncertainty in measurement was $57.75{\pm}8.76{\mu}g/kg$ (k=2.0). Therefore, it showed that the measurement uncertainty obtained by this analytical method influences on 15.2% of the contents of hyaluronic acid as the analytical results.

Accuracy and Usefulness of Volume Measurement using CT and Ultrasound Scan Data (CT 및 초음파 스캔 데이터를 이용한 체적 측정의 정확도 및 유용성)

  • Kim, Hyeon-Ju;Lee, Hoo-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 2022
  • In this study, the accuracy and usefulness of volume measurement were investigated as a phantom experiment using CT and USG scan data and a clinical trial using patient scan data. As a result, there was no significant difference between the volume of the actual round phantom of various volumes for both the CT and ultrasound devices (p>0.05). As a result of statistical analysis, it was analyzed that there was no significant difference (p>0.05). Clinical application of this result requires more clinical trials, but if a CT or ultrasound device is selected and applied in consideration of patient radiation exposure, the examiner's scanning technology, and CT reconstruction experience, the basic data in terms of the usefulness of volume measurement using CT scan image is considered to have application value.

Validation of Urine Volume Evaluation by Hydraulic Pressure Measurement (압력 측정에 의한 요량 계측의 유용성 분석)

  • Kim, Kyung-Ah;Choi, Sung-Soo;Lee, In-Kwang;Park, Kyung-Soon;Kim, Wun-Jae;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.577-584
    • /
    • 2007
  • Uroflowmetry is non-invasive and easily performed to diagnose benign prostatic hypertrophy(BPH) frequent in aged men. Weight change during urination is usually measured to estimate the urinary flow rate by a load cell, but sensitive to any impacts against the bottom of the container, leading to unnecessary noise generation. Moreover, load cells are relatively expensive raising the production cost. The present study proposed a new technique, measuring hydraulic pressure on the bottom of the urine container to evaluate the urinary volume. Low cost pressure transducer enabled almost perfectly linear relationship between the urine volume and the hydraulic pressure. During both the simulated and human urination experiments, variance of the pressure signal was more than 50% smaller than the weight signal acquired by a load cell, which demonstrated that the impact noise was decreased to a great degree by pressure compared to weight measurement.

Effects of Sweet Bee Venom on the respiratory system in Rats (Sweet Bee Venom 시술이 Rat의 호흡기계에 미치는 영향)

  • Lee, Jong-Young;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.14 no.3
    • /
    • pp.47-53
    • /
    • 2011
  • Objectives: This study was performed to analyse the effects of Sweet Bee Venom(SBV-purified melittin supported by G&V Co., the major component of honey bee venom) on the respiratory system in rats. Methods: All experiments were conducted at Biotoxtech Company, a non-clinical studies authorized institution, under the regulations of Good Laboratory Practice(GLP). Male rats of 5 weeks old were chosen for this study and after confirming condition of rats was stable, SBV was administered in thigh muscle of rats in 0.175, 0.35 and 0.7 mg/kg dosage. And checked the effects of SBV on the respiratory system using the whole body plethysmography. And respiratory rate, tidal volume and minute volume of rats were checked after administered SBV (melittin). Results: 1. In the measurement of respiratory rate, there were not observed any significant differences compared with control group. 2. In the measurement of tidal volume, there was not observed any significant differences compared with control group. 3. In the measurement of minute volume, 0.35mg/kg dosage group showed significant differences compared with control group. But we estimated that this result was caused by individual differences. Conclusions: Above findings suggest that SBV seems to be safe treatment in the respiratory system of rats. And further studies on the subject should be conducted to yield more concrete evidences.