• Title/Summary/Keyword: volume measurement

Search Result 1,621, Processing Time 0.029 seconds

A New Ultrasound Bladder Scanner to Estimate Urine Volume Using Hand-Motion Scan (손 동작 스캔을 이용한 잔뇨량 측정용 초음파 방광 스캐너)

  • Lee, Jung Hwan;Bae, Jung Ho;Lee, Soo Yeol;Cho, Min Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.153-160
    • /
    • 2018
  • 3D ultrasound bladder scanners are getting popular in hospitals for the patients with bladder dysfunction. A current bladder scanner adopts a mechanical scan to acquire 3D images and requires two motors and complicated mechanical devices. In this paper, we propose a new ultrasound bladder scanner using hand-motion scan. Instead of two motors and mechanical devices, it has a motion sensor to record transducer positions during hand-motion scan. The experiments with a bladder phantom and volunteers showed similar measurement accuracy to a conventional 3D ultrasound bladder scanner. We expect that the proposed method will reduce the cost and size of the bladder scanner.

The Volume Resistivity Properties due to Mixture ratio of Linear Low Density Polyethylene and Ethylene Vinyl Acetate (선형 저밀도 폴리에틸렌과 에틸렌 비닐아세테이트의 혼합비에 따른 체적고유저항 특성)

  • 박정구;육영수;신현택;신종열;이충호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.552-555
    • /
    • 1999
  • In this paper, the volume resistivity properties due to mixture ration of linear low density polyethylene(LLDPE) and ethylene vinyl acetate(EVA) are studied. Electrodes is composed of upper electrode 37(mm $\Phi$), guardring electrode(inner 55(mm $\Phi$ ), and lower electrode 87(mm $\Phi$ In order to measure the leakage current, We used electrometer and stable oven with temperature controller. Measurement method is to measure the leakage current of next specimen after applying the voltage according to 'Step Apply Methods' for ten minutes. In order to measure the volume resistivity properties, the micro electrometer is used, the range of temperature and applying voltage are 25 to 100[$^{\circ}C$] to 100[V] respectively.

  • PDF

Numerical study on the flow characteristics in Air-conditioner duct of EMU (전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구)

  • Kim Seung-Tech;Kim Sung-Jong;Park Geun-Soo;Park Hyung-Soon
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

EVALUATION OF VOLUME VELOCITY OF A LOUDSPEAKER IN A CHAMBER

  • Lee, J.S.;Ih, J.G.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.770-774
    • /
    • 1994
  • The volume of an acoustic source is important in determining various acoustic parameters. One of the suggested techniques is the internal pressure method incorporating a loudspeaker attached to a chamber wall and a microphone inserted into the cavity. Although the method is easy to handle with a very simple measurement setup, the coupling effects between the dynamic system of the loudspeaker and acoustic field, and the effects of higher order modes introduced by the discontinuities in the acoustic field, and the effects of higher order modes introduced by the discontinuities in the acoustic field should be considered for precise result. In this study, higher order modes due to the discontinuities of loudspeaker and microphone boundaries are included and the electro-acoustic coupling effects are compensated for by using the results of two cylinders with different lengths. The volume velocity of a loudspeaker thus obtained agrees very with that measured by laser sensor.

  • PDF

Uncertainty Evaluation of the Analysis of 11-Nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol in Human Urine by GC/MS (GC/MS를 이용한 소변 중 대마 대사체 분석의 측정불확도 평가)

  • Kim, Jin-Young;Jeong, Jae-Chul;Suh, Sung-Ill;Suh, Yong-Jun;Lee, Jeong-Jik;Kim, Jong-Sang;In, Moon-Kyo
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.480-487
    • /
    • 2008
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH), the major metabolite of ${\Delta}^9$-tetrahydrocannabinol, in urine sample by solid-phase extraction (SPE) and GC/MS detection. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day and inter-person validation were performed using statistical analysis of several indicative factors. Measurement uncertainty associated with target analyte in real forensic samples was estimated using quality control (QC) data. Traceability of measurement was established through traceable standards, calibrated volumetric glassware and volume measuring device. The major factors of contribution to combined standard uncertainty, were calibration linearity, inter-day repeatability and inter-person reproducibility, while those associated with preparation of analytical standards and sampling volume were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method was 12.05% for THCCOOH.

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

A Study on the Development of Ultrasonic Urine Volume Detection Sensor and the Correlation between Urine Volume and Bladder Interwall Distance (초음파 뇨량검출 센서의 제작 및 방광 벽간거리와 뇨량과의 상관관계에 관한 연구)

  • Choi, H.H.;Lee, E.H.
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.256-267
    • /
    • 2000
  • In this paper, we studied the ultrasonic urine volume sensor of urinary alarm system for home use to detect the time of urination as a assistive methodology for the incontinence patients and the correlation between urine volume and bladder interwall distance by using developed sensor. The developed sensor was designed to minimize the measurement error by using ultrasound with 2.25 MHz center frequency which provides higher resolution as well as longer penetration depth. To verify usefulness of the developed sensor, we performed a preliminary experiment of estimating bladder volume from the measured distance between interior and posterior wall of bladder. In the preliminary experiment, bladder volume estimated from the result using a commercial ultrasonography system. The experimental results show there exists god correlation between the actual urine volume and the measured interwall distance of the bladder. In conclusion, the developed ultrasound bladder volume sensor can be applied to an urine alarm system which provides patient the exact time of urination, it will be contribute in health care and welfare society.

  • PDF

Calculation and Uncertainty Estimation of the Volume of Reverberation Chamber with Indeterminate Form (부정형 잔향실의 체적 산출과 체적 불착도 평가)

  • Suh, Jae-Gap;Suh, Sang-Joon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.8
    • /
    • pp.375-380
    • /
    • 2007
  • A reverberation chamber should be designed and constructed so as to satisfy its purposes and available space. However, it is somewhat difficult to meet the intended design requirements due to various errors from construction process. So, the post-construction measurement of its volume and surface areas is very essential to check the actual volume and volume uncertainty of a reverberation chamber These values should be carefully calculated and accurately estimated since they are used not only to evaluate the acoustic characteristics of building materials but also to calculate uncertainties for other acoustic characteristics. In this work, the method for the calculation and uncertainty estimation of the volume of a reverberation chamber is presented. To this end, the coordinates of all corners was measured with Total Station after construction. The results showed that the calculated volume of the measured reverberation chamber differs by 5 % from the design specification. The expanded volume uncertainty was also estimated to be about 2 % of the total calculated volume.

Developing Stem Volume Table of Pinus thunbergii Parl. in Southern Region Based on Comparison of Major Taper Equations (주요 수간곡선식 비교에 따른 남부지역 곰솔 수간재적표 개발)

  • Hyun-Soo Kim;Su-Young Jung;Kwang-Soo, Lee
    • Journal of Environmental Science International
    • /
    • v.33 no.7
    • /
    • pp.453-462
    • /
    • 2024
  • This study was carried out for the purpose of selecting the most appropriate taper equation for the actual stands of Pinus thunbergii in the southern coastal region of Korea and then developing a stem volume table to provide basic data for rational management. To develop a volume table of Pinus thunbergii in this region of Korea, 59 sample trees with various diameter distributions were selected and stem analysis was performed. As a result of stem analysis, two trees with abnormal diameter and height growth as the age increased were rejected, and 57 trees were analyzed. To develop the taper equation, seven major variable exponential equations were used, including Kozak 1988, 1994, 2001, 2002, Bi 2000, Muhairwe 1999, and Sharma and Parton 2009. As a result of parameter estimation and statistical verification, the Kozak 1988 model showed the highest goodness of fit with Fit I (Fit Index), RMSE 1.5620, Bias 0.0031, and MAD 1.0784. The diameter of each 10cm stem ridge for the selected model was estimated, and a stem volume table was produced using the mensuration of division (end area formula) using the Smalian equation. As a result of two-sample T-test for volume table of this study and current yield table, the volume for this study was found to be significantly larger at all observation points (p < 0.001). Even for the same tree species, it is judged that differentiated volume tables are needed for each growth environment characteristic.