• Title/Summary/Keyword: volume measurement

Search Result 1,622, Processing Time 0.033 seconds

Development of screening systems for modulators on phospholipase-mediated signal transduction

  • Lee, Young-Han-;Min, Do-Sik;Kim, Jae-Ho-;Suh, Pann-Ghill;Ryu, Sung-Ho
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.186-186
    • /
    • 1994
  • Many agonists have been known to activate the hydrolysis of membrane phospholipids through the bindings with corresponding receptors on the various cells. Diacylglycerol and inositol 1,4,5-trisphosphate(IP3) generated by the action of phosphoinositide-specific phospholipase C (PI-PLC) are well known second messengers for the activation of protein kinase C and the mobilization of Ca2+ in many cells. Three types of PI-PLC isozyme (${\alpha}$,${\gamma}$, and $\delta$) and several subtrpes for each type have been identified from mammalian sources by purification of enzymes and cloning of their cDNAs. Each type PI-PLC isozyme is coupled to different receptors and mediators, for example, ${\beta}$-types are coupled to the seven-transmembrane-receptors via Gq family of G-proteins and ${\beta}$-types directly to the receptor tyrosine kinases. Specific modulators for the signaling pathway through each type of PI-PLC should be very useful as potential potential candidates for lend substances in developing novel drugs. To establish the sensitive and convenient screening systems for searching modulators on PI-PLC mediated signaling, two kinds of approaches have been tried. (1) Establishment of in vitro assay condition for each type of PI-PLC isozyme: Overexpression by using vaccinia virus and purification of each isozyme was carried out for the preparation of large amounts of enaymes. Optimum and sensitive assay condition for the measurements of PI-ELC activities were established. (2) Development of the cell lines in which each type of PI-PLC is permanently overexpressed: A fibroblast cell line (3T3${\gamma}$1-7) in which PI-PLC-${\gamma}$1 was overexpressed by using pZip-neo expression vector was developed and used for the measurement of PDGF-induced IP3 formation. The responses for IP3 formed in 3T3${\gamma}$1-7 cells by the treatment of PDGF is 8 times more sensitive than those in control cells. 3T3${\gamma}$l-7 cell is useful for the screening of the inhibitors on the PDGF-induced cellular responses from large number of samples in a small volume(50 ${\mu}$l) and short time(5-15 min). Using these systems, we screened hundreds of herb-extracts for the inhibition of PDGF-induced IP3 formation and selected several extracts that showed the inhibition as the candidates for isolation and characterization of active substances. The determination of the acting point of selected extracts or fractions in the PDGF signaling pathway has been analyzing.

  • PDF

A Study of Iron Status and Anemia in Female High School Students in Ulsan (울산시 여고생의 철분영양상태와 빈혈에 관한 연구)

  • 홍순명;황혜진;박상규
    • Korean Journal of Community Nutrition
    • /
    • v.6 no.1
    • /
    • pp.28-35
    • /
    • 2001
  • This study was designed to assess the iron nutritional status and anemia of high school students. 383 female subjects in Ulsan Metropolitan city were evaluated using a questionnaire, and a measurement of hematological indices. The average height and weight of the respondents were 161.24$\pm$4.90 cm and 53.12$\pm$6.37kg, repectively. The average BMI(body mass index) was 20.43$\pm$2.26 which was in the normal ramge. The average hemoglobin(Hb) concentration of the subjects was 13.14$\pm$0.97g/dl, and the average hematocrit(Hct) level was 40.84$\pm$17.40%. Transferrin saturation{TS(%)} was 20.86$\pm$10.32%, and the ferritin by Hct(<36%), 27.2%by TS(<14%),26.6% by ferritin(<12 ng/ml). As for clinical symptoms, the greatest number of respondents reported that they experienced ‘decreased ability to concectrate’. Mean daily intakes of iron were 14.89$\pm$4.48 mg and heme iron intakes were 5.04$\pm$2.13 mg, which was 29.6% of total iron intake. The total iron binding capacity(TIBC) was negatively correlated with Hb concentration(r= -0.222, p<0.01). Serum ferritin was positively correlated with Hb concentration(r= - 0.323, p<0.05) and negatively correlated with TIBC(r= -0.367, p<0.01). TS(%) was positively correlated with Hb concentration(r= 0.402, p<0.01) and positively correlated with serum ferritin(r=0.413, p<0.01). As for the correlation between blood biochemistry and clinical symptoms related to anemia, the Hb concentration was negatively correlated with ‘shortening of breath when going upstairs(p>0.05)’ and ‘cold hands and feet’ significantly(r= -0.109, p<0.05). The level of Mean corpuscular volume(MCV) was negatively correlated with ‘feel dizzy when standing up’,‘tired out easily’, and ‘decrease ability to concentrate’ significantly(p<0.05). In particular, the level of Fe was negatively correlated with ‘shortening of breath when going upstairs’ and ‘feeling blue’ significantly(p<0.01). These results suggest That the prevalence of iron deficiency of female high school students is very high, therefore guidelines for diet supports and nutrition education to improve their iron status should be provided.

  • PDF

A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time (버블의 크기별 입도분포와 부상시간과의 상관특성에 관한 연구)

  • Jeon, Gun;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.277-281
    • /
    • 2017
  • Lately rainfall characteristics that it rains a lot in a short space of time often occurs. Because of this meteorological phenomena, the flow rate and concentration of initial rainfall for runoff and combined sewer overflows are changed. In the case of this inlet fluctuation, the flotation method at high surface loading rate is suitable for water quality management. the flotation method is able to meet the removal rate requirements of water public zone in 5 to 10 min which is irelatively short period. For assessment and diagonision of flotation method, A/S ratio is applied until now. But unfortunately, this has some limits for evaluation standard for certification and assessment of technical diagnosis and operation. This is why there is different efficiency in the bubble distribution at the same A/S ratio. The velocity and time of floating is changed by the different bubble distributions. The floating time affects the plant volume because the time factor make size dicision. Therefore the charateristics of bubble distribution and floating time at the same A/S ratio is necessary to apply to evaluation standard for certification and assessment of technical diagnosis and operation. For generalization of the method in certification and assessment, the characteristics of bubble distribution was studied. Until recently, using the optical device and shooting live video, there are some analysis technology of the floating factors. But this kind of technology is influenced by the equipment. with this level of confidence about the results, it is difficult to apply to generalize. According this reasons, this study should be applied on experiment generalization of method about measurement of relation between bubble distribution and floating time.

Difference of Autonomic Nervous System Responses among Boredom, Pain, and Surprise (무료함, 통증, 그리고 놀람 정서 간 자율신경계 반응의 차이)

  • Jang, Eun-Hye;Eum, Yeong-Ji;Park, Byoung-Jun;Kim, Sang-Hyeob;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.503-512
    • /
    • 2011
  • Recently in HCI research, emotion recognition is one of the core processes to implement emotional intelligence. There are many studies using bio signals in order to recognize human emotions, but it has been done merely for the basic emotions and very few exists for the other emotions. The purpose of present study is to confirm the difference of autonomic nervous system (ANS) response in three emotions (boredom, pain, and surprise). There were totally 217 of participants (male 96, female 121), we presented audio-visual stimulus to induce boredom and surprise, and pressure by using the sphygmomanometer for pain. During presented emotional stimuli, we measured electrodermal activity (EDA), skin temperature (SKT), electrocardiac activity (ECG) and photoplethysmography (PPG), besides; we required them to classify their present emotion and its intensity according to the emotion assessment scale. As the results of emotional stimulus evaluation, emotional stimulus which we used was shown to mean 92.5% of relevance and 5.43 of efficiency; this inferred that each emotional stimulus caused its own emotion quite effectively. When we analyzed the results of the ANS response which had been measured, we ascertained the significant difference between the baseline and emotional state on skin conductance response, SKT, heart rate, low frequency and blood volume pulse amplitude. In addition, the ANS response caused by each emotion had significant differences among the emotions. These results can probably be able to use to extend the emotion theory and develop the algorithm in recognition of three kinds of emotions (boredom, surprise, and pain) by response measurement indicators and be used to make applications for differentiating various human emotions in computer system.

  • PDF

Development for the Azimuth Measurement Algorithm using Multi Sensor Fusion Method (멀티센서 퓨전 기법을 활용한 방위 측정 알고리즘의 설계)

  • Kim, Tae-Yeong;Kim, Young-Chul;Song, Moon-Kyou;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.865-871
    • /
    • 2011
  • Presently, the location and direction information are certainly needed for the autonomous vehicle of the ship. Among them, the direction information is a essential elements to automatic steering system. And the gyro-compass, the magnetic-compass and the GPS compass are the sensor indicating the direction. The gyro-compasses are mainly used in the large-sized ship of the GMDSS(Global Maritime Distress & Safety System). The precision and the reliability of the gyro-compasses are excellent but big volume and high price are disadvantage. The magnetic-compass has relatively fine precision and inexpensive price. However, the disadvantage is in the influence by the magnetism object including the steel structure of a ship, and etc. In the case of the GPS compass, the true north is indicated according to the change of the location information but in case of the minimum number of satellites or stopping of a ship or exercise in the error range, the exact direction cannot be obtained. In this paper, the performance of the GPS compass was improved by using the least-square curve fitting method for the mutual trade off of the angle sensor. The algorithm which improves the precision of an azimuth by applying the weighted value according to the size of covariance error was proposed with GPS-compass and magnetic compass. The characteristic and the performance of the proposed algorithm were analyzed and verified through experimentation. The applicability of the proposed algorithm was shown through the experimental result.

Effect of $M_{2}CO_{3}$(M=Li, Na) Addition on the Humidity Sensitivity of $V_{2}O_{5}$-doped $TiO_2$ ($V_{2}O_{5}$를 dopant로 한 $TiO_2$의 감습에 미치는 $M_{2}CO_{3}$(M=Li, Na)의 영향)

  • 강이국;송창열;신용덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.343-346
    • /
    • 1995
  • In this paper, the effect of alkaline oxides on the humidity sensitivity of $V_2O_{5}$(2mol%)-doped $TiO_2$(98mol%) was investigated as functions of $Li_{2}Co_{3}$, $Na_{2}Co_{3}$. III-1. Measurement of Density. When the mole% of $Li_2$O is varied 0,1,2,5mol%, the more the mole% of additives is increased, the more difference of bulk and apparent density is largely narrowed. The difference of two densities of sample containing 2mol% $Na_2O$ was large all the moat. The sample containing 1mol% $Na_2O$ was small most. III-2. Observation of porosity. The porosity and total intrusion volume according to various amounts of $Li_2O$ was reduced and those of sample containing 2mol% $Na_2O$ as 31.13%, 0.1155mL/g was the highest and 1mol% $Na_2O$ was lowed most and 5, 10mol% $Na_2O$ was more high compare with sample without alkaline oxides. III-3. Characteristic of humidity sensitivity. 1. Impedance of samples containing $Li_2O$ was high compare with sample without alkaline oxides, so we thought it showed Poor sensitivity because it have no impedance changing rapidly as function of relative humidity. 2. When the humidity was increasing from 30RH% to 90RH%, the impedance of sample containing 2mol% $Na_2O$ at 120HZ changed exponential rapidly from 6${\times}$$10^{7}$$\Omega$) to 1.25${\times}$$10^4$$\Omega$. At under 50RH% and over 50RH%, the humidity sensitivity of samples containing 2mol% $Na_2O$ was best especially in the range of the low humidity. III-4. Characteristic of TG curves. When algal me oxide $M_{2}CO_{3}$(M=Li, Na) were added into $V_{2}O_{5}$-doped $TiO_2$, the stability of humidity sensitivity of samples containing amounts of $Li_2O$ was unstable. The samples containing 1mol% $Na_2O$ was unstable.

  • PDF

Herbal Medicine for Cervical Intraepithelial Neoplasia After Loop Electrosurgical Excision Procedure: A Systematic Review and Meta-Analysis (자궁경부 상피내종양의 환상투열요법 후 한약치료의 효과 : 체계적 문헌고찰 및 메타분석)

  • Lee, Su-Jeong;Ji, Hae-Ri;Lee, Hye-Jung;Hwang, Deok-Sang;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.2
    • /
    • pp.44-62
    • /
    • 2020
  • Objectives: The purpose of this study is to evaluate the effectiveness of herbal medicine for recovery and treatment of cervical intraepithelial neoplasia (CIN) after loop electrosurgical excision procedure (LEEP). Methods: We searched two english, one chinese and four korean database up to November 4, 2019. Randomised controlled trials (RCTs) were eligible. Primary outcome included Human papilloma virus (HPV) clearance rate and the effective ratio of treatment. And vaginal bleeding time and volume, improvement of symptoms, and recovery of wound were regarded as secondary outcomes. The risk of bias was assessed by two independent authors using the Cochrane risk of bias tool. Results: Of 47 screened, 10 RCTs were included. Number of participants per study ranged from 58 to 360. The studies which used HPV clearance rate as primary outcome were considered as low risk of bias. Most of the studies had considerable heterogeneity in terms of type of intervention, comparison and time-points for outcome measurement. Compared to LEEP alone, herbal vaginal suppository combined group showed favorable results for HPV clearance in patients (5 studies, n=627, 95% CI 1.26 to 1.55, I2=75%). And compared to LEEP alone, herbal external application also showed favorable results for HPV clearance in patients (2 studies, n=252, 95% CI 1.19 to 1.61, I2=86%). Three studies reported mild and temporary adverse events, and no serious adverse events were reported. Conclusions: The studies showed that herbal medicine can significantly effective on recovery of CIN after LEEP. However, included studies suffered from incomplete reporting, high or unclear risk of bias and substantial heterogeneity between studies. In the Future, further high-quality RCTs are needed to prove effectiveness of herbal medicine for CIN after LEEP and reduce the risk of bias.

Yolk absorption and growth of churn salmon, Oncorhynchus keta alevin (연어, Oncorhynchus keta전기자어의 난황흡수 및 초기성장)

  • ZHANG Chang Ik;SOHN Myoung Ho;SEONG Ki Baik;PARK In-Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.5
    • /
    • pp.539-548
    • /
    • 1995
  • The process of yolk absorption and the growth pattern of churn salmon, Oncorhynchus keta alevin were studied. Matured males and females of chum salmon were sampled from the Namdaechun River in the east coast of Korea, and then an artificial fertilization was carried out using their eggs and sperms. Fertilized eggs were incubated in controlled water temperature of $13^{\circ}C$ and samples of 40 alevins were randomly taken at just hatching and at every three days between 12 days alter hatching and yolk absorption. The means of total length and total weight of hatched alevins were respectively 1.97cm and 1.85g and the yolk absorption took about 33 days after hatching, based on the morphological measurement. Growth curves of total length, total weight and somatic weight were fitted well with the Gompertz growth model. However, the shrinking in yolk-sac length, yolk-sac weight, yolk-sac height and yolk-sac volume revealed a linear phenomenon until the absorption of yolk was completed. The relative growth of chum salmon alevin, such as the relationship between total length and total weight, or between total weight and yolk-sac weight, was also studied.

  • PDF

Development of Base Concrete Block for Quiet Pavement System (저소음 포장용 기층 콘크리트 블록 개발)

  • Lee, Kwan-Ho;Park, Woo-Jin;Kim, Kwang-Yeom
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2010
  • The rapid economic development induced the massive road constructions, becoming bigger and high-speed of the vehicles. However, it brings lots of social problems, such as air pollutions, traffic noise and vibration. Special concrete block for the base course of asphalt pavement is needed to decrease traffic noise such as tire's explosive and vehicles sound, applying Helmholtz Resonators theory to asphalt pavement. If it is applied to the area where it happens considerable noise such as a junction, the street of a housing complex and a residential street, it is one of considerable method to solve the social requirements of noise problem. This research examines couple of laboratory tests for the sound absorption effect of the concrete block and the base concrete block. There are specimens which is fixed hall-size, space, depth as the condition of this research, and these are analysed of noise decrease effect using different condition of the first noise of each vehicle. As a result of analysis data according to vehicle noise volume, measurement distance, a form and size of the hall using the base concrete block, the use of special concrete base showed a good alternative solution for decreasing traffic noise level, from 4 dB to 9 dB.

A study on the Traffic Density Collect System using View Synthesis and Data Analysis (영상정합을 이용한 교통밀도 수집방법과 수집 데이터 비교분석)

  • Park, Bumjin;Roh, Chang-gyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.5
    • /
    • pp.77-87
    • /
    • 2018
  • Traffic Density is the most important of the three primary macroscopic traffic stream parameters, because it is most directly related to traffic demand(Traffic Engineering, 2004). It is defined as the number of existing vehicles within a given distance at a certain time. However, due to weather, road conditions, and cost issues, collecting density directly on the field is difficult. This makes studies of density less actively than those of traffic volume or velocity. For these reasons, there is insufficient attempts on divers collecting methods or researches on the accuracy of measured values. In this paper, we used the 'Density Measuring System' based on the synthesise technology of several camera images as a method to measure density. The collected density value by the 'Density Mesuring System' is selected as the true value based on the density define, and this value was compared with the density calculated by the traditional measurement methods. As a result of the comparison, the density value using the fundamental equation method is the closest to the true value as RMSE shows 1.8 to 2.5. In addition, we investigated some issues that can be overlooked easily such as the collecting interval to be considered on collecting density directly by calculating the moment density and the average density. Despite the actual traffic situation of the experiment site is LOS B, it is difficult to judge the real traffic situation because the moment density values per second are observed max 16.0 (veh/km) to min 2.0 (veh/km). However, the average density measured for 15 minutes at 30-second intervals was 8.3-7.9 (veh/km) and it indicates precisely LOS B.