• Title/Summary/Keyword: volume change ratio

Search Result 485, Processing Time 0.025 seconds

Design and Implementation of Multiband Internal Antenna for LTE Mobile Handset

  • Cho, Young Min;Jung, Pil Hyun;Yang, Woon Geun
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.124-132
    • /
    • 2015
  • In this paper, we proposed a multiband internal antenna for LTE mobile handset that could be used for mobile devices. The proposed antenna has a volume of $50mm(W){\times}21mm(L){\times}5mm(H)$, ground plane size is $60mm(W){\times}100mm(L)$, and covers 9 service frequency bands including LTE(Long Term Evolution) band with VSWR(Vlotage Standing Wave Ratio) less than 3. With rapid change of technologies, people wants to include more function into one device. In addition, each country uses different frequency band for traffic service, it is necessary to design multiband antenna for mobile phone since traveling foreign country needs roaming. And if we can cover several services with one antenna, cost and volume needed for antennas are minimized. A HFSS (High Frequency Structure Simulator) of the Ansoft Corporation based on a finite element method is employed to analyze the proposed antenna in the design process and to compare the simulation and experimental results.

A Design for Natural Gas Reforming Reactor (천연가스 개질기 설계)

  • Lee, Taeckhong;Choi, Woonsun
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.5
    • /
    • pp.545-550
    • /
    • 2012
  • This work is for the design study of natural gas reformer (40 $m^3/hr$ over). We used experimental kinetic data from literature. After that, we set up theoretical model based on experimental reaction kinetic data. The shape of reactor is 1.7 m long and 200 mm dia. with cylinder geometry. Volume of reactor is 53.4 liter. Average flow velocity of gases in the reactor has been determined 0.272 m/sec and residence time is 9.26 sec. Reaction temperature is $850^{\circ}C$, with pressure 9.3 Bar. Used natural gas volume is about 9.21 $m^3/hr$. Produced hydrogen is 43.7 $m^3/hr$ with no change of pressure. Unreacted natural gas is 0.09 $m^3/hr$ and the amount of steam is 26.9 $m^3/hr$. Steam to $CH_4$ (s/c ratio) is 2.91. Reforming reaction take place from the reactor entrance to 120 cm region of cylinder type reactor. After the entrance of reacting gases to 120 cm region, the reaction reaches equilibrium which is close to products. This study can be applicable to design various reactors. Output data is in good agreements with the data in literatures1).

Experimental study on treatment of waste slurry by vacuum preloading with different conditioning agents

  • Wu, Yajun;Jiang, Haibo;Lu, Yitian;Sun, Dean
    • Geomechanics and Engineering
    • /
    • v.17 no.6
    • /
    • pp.543-551
    • /
    • 2019
  • In China, serious environmental problems are induced by the extremely soft construction waste slurries in many urban areas, and there is no appropriate method to treat it presently. In this paper, four model tests were conducted to investigate the efficiency of waste slurry treatment by combining three conditioning agents which can change characteristics of the slurries with a traditional vacuum preloading method. The tests of size analysis of particle aggregate were conducted to investigate the influence of different conditioning agents on the size distributions of particle aggregate. During the model test, the discharged water volumes were monitored. The pore-size distribution and void ratio of the waste slurries after the vacuum preloading were measured by mercury intrusion porosimetry (MIP). It is found that 1) During the natural precipitation, volume of water out of the organic agent is higher than that of the mixed agent, but it is smaller than that of the mixed agent in the vacuum preloading stage; 2) the mixed agent has a higher total volume of water out than the organic agent and the inorganic agent after test, while the organic agent and the inorganic agent have little difference with respect to the drainage effect. The results demonstrate that the combination of mixed conditioning agent and vacuum preloading for the solid-liquid separation in waste slurry has a satisfactory effect and can be applied in engineering practice.

Analytical Study on Unsteady Flow Characteristics of Urea-SCR Single Hole Injector depend on Nozzle Shape Change (Urea-SCR 단홀 Injector 노즐형상 변화에 따른 비정상유동특성의 해석적 연구)

  • Hwang, Jun Hwan;Park, Sung-Young
    • Journal of ILASS-Korea
    • /
    • v.24 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • In this paper, a study of Urea-SCR System for Dosing Injector for responding to enhanced environmental regulations has been conducted. There is a limit to the experimental approach due to the structural characteristics of the injector. In order to overcome this problem, The analysis was performed assuming unsteady turbulent flow through computational fluid analysis and the internal flow characteristics of the injector were analyzed. By changing the nozzle shape of the injector, the performance factors of the swirl injector by shape were selected and compared. The design parameters were modified by changing the diameter of the nozzle at a constant ratio compared to the base model. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. The Conv. model to which the taper was applied showed the dominance in mass flow rate, discharge coefficient and swirl because of the smooth fluid flow by shape. Swirl coefficient, outlet mass flow, and sac volume were selected as performance parameters of the injector. As a result of the comparison coefficient derivation with those performance parameters for comparing the performance of the model-specific injector, the Conv-140 model with the nozzle diameter expanded by 140% showed the best value of the comparison coefficient.

Experimental study and numerical modeling of liquid sloshing damping in a cylindrical container with annular and sectorial baffles

  • Mohammadi, Mohammad Mahdi;Moosazadeh, Hamid
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.4
    • /
    • pp.349-366
    • /
    • 2022
  • The ability of baffles in increasing the sloshing damping is investigated in this study by theoretical, numerical, and experimental methods. Baffles Installed as separators in containers, can change the dynamic properties of sloshing. The main purpose of this study is to investigate the effect of baffle placement.The main purpose of this study is to investigate the effect of placing baffles in order to provide appropriate frequencies and damping and to present a practical baffle arrangement in the design ofsloshing. In this regard, an experimental setup is designed to study the fluid sloshing behavior and damping properties in cylindrical tanks filled up to an arbitrary depth. A new combination of annular and sectorial baffles is employed to evaluate fluid sloshing in the tank. The results show that the proposed baffle arrangement has a desired effect on the damping and fluid sloshing frequencies and optimally satisfies the anticipated design requirements. In addition, the theoretical frequencies exceed empirical frequencies at the points far from baffles, while at the points close to baffles, the empirical ones are higher than theoretical ones. Also, at the depths near the bottom of container sloshing frequencies are not affected by sectorial baffles, although the theoretical curve predicts a reduction in the fundamental frequency of sloshing. Finally, the results of finite volume and finite element methods which compared with experimental data, indicated a good agreement between different approaches.

Coincidence Summing Corrections in HPGe Gamma Ray Spectrometry in Marinelli-beakers with Efficiency (효율을 적용한 마리넬리 비이커에서 HPGe 감마선 분광분석법의 동시합성보정)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.557-563
    • /
    • 2018
  • Coincidence summing correction effects are known to be greater as the efficiency of the detector increases and as the distance between the source and the detector increases. A point source($^{60}Co$) was used to vary the distance in the direction of the detector's center axis and in the radial direction to obtain the P/T ratio for Coincidence summing correction calibration. In this study, values for coincidence summing corrected calibration of the values in the central and radial directions were applied to the mixed volume source(450 ml CRM source) to compare the overall peak efficiency change according to P/T with Geant4. In addition, the efficiency obtained from the mapping method is applied to the seaweed, a marine sample, and the compatibility of the P/T ratio with the detector and sample very dose together. The efficiency corrected to 1,836 keV was applied to the energy zone affected by the efficiency of 500 keV and the relative error of the measured and corrected values was well matcched by the 3.2 % peak efficiency correction. As with 450 mL CRM source, the larger the volume, the lower the P/T ratio was by ${\pm}5%$. This is due to the increased scattering of gamma-rays emitted as the source becomes farther away from the detector, and this change in P/T has been confirmed to affect the Coincidence summing corrected peak efficiency.

Evaluating Shrinkage Characteristic of Ternary Grout for PSC Bridge Using Expansive Additive and Shrinkage Reducing Agent (팽창재 및 수축저감제를 이용한 PSC 교량용 3성분계 그라우트의 수축특성 평가)

  • Yuan, Tian-Feng;An, Gi-Hong;Ryu, Gum-Sung;Koh, Kyoung-Taek;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.5
    • /
    • pp.519-525
    • /
    • 2016
  • This paper reports on analyzing the free and restrained shrinkage characteristic of ternary grout used cementitious admixture. In this study, the cementitious admixture was used such as fly ash, ziricania silica fume by combination of expansive additive (a, b) and shrinkage reducing agent. And a number of basic performance tests were conducted to investigate bleeding, volume change, fluidity and compressive strength behavior. According to the results, within appropriate mixing ratio, even the fluidity is not influenced by expansive additive and shrinkage reducing agent, the resistant properties of bleeding, volume change, shrinkage and compressive strength are increased. Comparing with plain grout, the free shrinkage reduced by a minimum of 29% which specimens are added expansive additive and shrinkage reducing agent. The combination of expansive additive a and shrinkage reducing agent is the most effective for reduction of shrinkage. And increasing the mixing ratio of expansive additive and shrinkage reducing agent extended cracking time. Nevertheless, combined addition of expansive additive a 2.0% and shrinkage reducing agent 0.50% has best shrinkage reduction behavior and not appeared cracking. From the above, the mixing ratio of 2.0% of expansive additive a and 0.50% of shrinkage reducing agent is high performance ternary grout for PSC bridge.

Change of Physical Properties on Long-Term Fertilization of Compost and Silicate in Paddy Soils (퇴비 및 규산질비료의 장기연용에 따른 토양 물리적특성 변화)

  • Park, Chang-Young;Choi, Jyung;Park, Ki-Do;Jeon, Weon-Tai;Kwon, Hye-Young;Kang, Ui-Gum
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.3
    • /
    • pp.175-181
    • /
    • 2000
  • This study was carried out to investigate the change of soil physical properties in long-term fertilized paddy soils with a Fine silty family of Typic Halpaqueps (Pyeongtaeg series). Treatments fertilized consisted of no fertilizer, compost, NPK, NPK+compost for thirty one years and of NPK+silicate for seventeen years. Water stable aggregate and degree of aggregate stability, which were higher in surface-soil than sub-soil, were high in order of NPK + compost > NPK + silicate > compost > NPK > no fertilizer plot. The ratio of aggregate larger than 0.5mm was high at compost and silicate plots but that smaller than 0.5mm was high at no fertilizer and NPK plots. And this aggregate stability showed negative correlation with soil hardness and bulk density ; positive correlation with sedimentation volume of soils in water. Sedimentation volume of soils in water was a little higher in surface-soil than sub-soil and in wet soil than dry soil, respectively. Pore space ratio and water retention capacity of soils were the most increased by the application of compost and not affected by silicate as in cases of liquid limit and plastic limit. Ignition loss of soils was high in order of NPK + compost > compost > NPK + silicate > NPK > no fertilizer plot. And field shattering ratio of soil mass smaller than 25.4mm was relatively high in NPK + compost, compost, and silicate plots.

  • PDF

Evaluation of Image Quality and Stability of Radiation Output according to Change in Tube Voltage and Sensitivity when Abdomen and Pelvis Examination of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 복부와 골반부 검사 시 관전압과 감도 변화에 따른 영상 화질과 방사선 출력의 안정성 평가)

  • Hwang, Jun-Ho;Yang, Hyung-Jin;Choi, Ji-An;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.12
    • /
    • pp.517-526
    • /
    • 2019
  • The purpose of this study is to find the optimal method for clinical application by analyzing image quality and radiation output according to parameter combination when using the Automatic Exposure Control (AEC). The experimental method combines 70, 81 kVp with sensitivity S200, S400, S800 and S1000 of the Automatic Exposure Control for Entrance Surface Dose (ESD), current volume, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR), Time-to-Radiation Dose Curve in abdomen and pelvis. And then, image quality and radiation output stability were evaluated. As a results, Entrance Surface Dose, current volume, Signal to Noise Ratio, Contrast to Noise Ratio decreased as the tube voltage and sensitivity were set higher. In addition, the higher tube voltage and sensitivity, the Time-to-Radiation Dose Curve showed a poor output stability. In conclusion, the higher the combination of tube voltage and sensitivity in the use of Automatic Exposure Control, the more problems can be seen in image quality and stability of the radiation output. Therefore, a relatively low combination of tube voltage and sensitivity showed that the image quality and radiation output stability could be optimized by minimizing the error range that would occur when the detector recognized a combination of parameters.

A Study on Characteristic Design Hourly Factor by Road Type for National Highways (일반국도 도로유형별 설계시간계수 특성에 관한 연구)

  • Ha, Jung-Ah
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.2
    • /
    • pp.52-62
    • /
    • 2013
  • Design Hourly Factor(DHF) is defined as the ratio of design hourly volume(DHV) to Average Annual Daily Traffic(AADT). Generally DHV used the 30th rank hourly volume. But this case DHV is affected by holiday volumes so the road is at risk for overdesigning. Computing K factor is available for counting 8,760 hour traffic volume, but it is impossible except permanent traffic counts. This study applied three method to make DHF, using 30th rank hourly volume to make DHF(method 1), using peak hour volume to make DHF(method 2). Another way to make DHF, rank hourly volumes ordered descending connect a curve smoothly to find the point which changes drastic(method 3). That point is design hour, thus design hourly factor is able to be computed. In addition road classified 3 type for national highway using factor analysis and cluster analysis, so we can analyze the characteristic of DHF by road type. DHF which was used method 1 is the largest at any other method. There is no difference in DHF by road type at method 2. This result shows for this reason because peak hour is hard to describe the characteristic of hourly volume change. DHF which was used method 3 is similar to HCM except recreation road but 118th rank hourly volume is appropriate.