• 제목/요약/키워드: voltage source inverter (VSI)

검색결과 118건 처리시간 0.021초

Voltage Impacts of a Variable Speed Wind Turbine on Distribution Networks

  • Kim, Seul-Ki;Kim, Eung-Sang
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권4호
    • /
    • pp.206-213
    • /
    • 2003
  • The main purpose of this paper is to present a simulation model for assessing the impacts of a variable speed wind turbine (VSWT) on the distribution network and perform a simulation analysis of voltage profiles along the wind turbine installed feeder using the presented model. The modeled wind energy conversion system consists of a fixed pitch wind turbine, a synchronous generator, a rectifier and a voltage source inverter (VSI). Detailed study on the voltage impacts of a variable speed wind turbine is conducted in terms of steady state and dynamic behaviors. Various capacities and different modes of variable speed wind turbines are simulated and investigated. Case studies demonstrate how feeder voltages are influenced by capacity and control modes of wind turbines and changes in wind speed under different network conditions. Modeling and simulation analysis is based on PSCAD/EMTDC a software package.

A Solid State Controller for Self-Excited Induction Generator for Voltage Regulation, Harmonic Compensation and Load Balancing

  • Singh Bhim;Murthy S. S.;Gupta Sushma
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.109-119
    • /
    • 2005
  • This paper deals with the performance analysis of static compensator (STATCOM) based voltage regulator for self­excited induction generators (SEIGs) supplying balanced/unbalanced and linear/ non-linear loads. In practice, most of the loads are linear. But the presence of non-linear loads in some applications injects harmonics into the generating system. Because an SEIG is a weak isolated system, these harmonics have a great effect on its performance. Additionally, SEIG's offer poor voltage regulation and require an adjustable reactive power source to maintain a constant terminal voltage under a varying load. A three-phase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC- VSI) known as STATCOM is used for harmonic elimination. It also provides the required reactive power an SEIG needs to maintain a constant terminal voltage under varying loads. A dynamic model of an SEIG-STATCOM system with the ability to simulate varying loads has been developed using a stationary d-q axes reference frame. This enables us to predict the behavior of the system under transient conditions. The simulated results show that by using a STATCOM based voltage regulator the SEIG terminal voltage can be maintained constant and free from harmonics under linear/non linear and balanced/unbalanced loads.

FACTS 기기의 고조파 저감을 위한 이중밴드 히스테리시스 전류 제어에 관한 연구 (A Study on Double Band Hysteresis Current Control based on 3-Level Inverter to reduce the harmonic component in output current of FACTS devices)

  • 최원경;최정혜;김범식;신은철;이상빈;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.180-182
    • /
    • 2005
  • The current control using a conventional hysteresis controller of a STATCOM based on two level VSI (Voltage Source Inverter) has high switching frequency and variable modulation frequency. This will increase the switching loss. In addition, the current error is not strictly limited So, in this paper to reduce the switching frequency and to maintain the constant modulation frequency, a novel double band hysteresis current controller based on 3-level VSI is proposed. A conventional hysteresis current control and a novel hysteresis current control was tested with digital simulation and verified the advantage of the novel hysteresis current controller.

  • PDF

엑티브필터 기능을 추가한 새로운 태양광 발전시스템의 제안 (Novel Concept of Shunt Active Filter Function Added in PV Generation System)

  • 김봉태;박민원;성기철;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.296-300
    • /
    • 2001
  • Novel concept of shunt active filter (AF) function added in Photovoltaic (PV) generation system is described in this paper. So far, for the PV generation system has been treated as one of harmonic sources to the power distribution systems, not only a PV system combined with AF but also AF systems using PV module as their power source have never been discussed. The basic structure and control strategy of the PV-AF system are, for the first time, introduced in this work. In order to stabilize the output current of voltage source inverter (VSI), the reference voltage MPPT control is applied. Simulation analysis shows that it is possible to combine AF function to the three-phase grid-connected PV generation system without any physical difficulties, and the performance of the proposed PV-AF system is acceptable and stable as well.

  • PDF

Comparative Study of Minimum Ripple Switching Loss PWM Hybrid Sequences for Two-level VSI Drives

  • Vivek, G.;Biswas, Jayanta;Nair, Meenu D.;Barai, Mukti
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1729-1750
    • /
    • 2018
  • Voltage source inverters (VSIs) are widely used to drive induction motors in industry applications. The quality of output waveforms depends on the switching sequences used in pulse width modulation (PWM). In this work, all existing optimal space vector pulse width modulation (SVPWM) switching strategies are studied. The performance of existing SVPWM switching strategies is optimized to realize a tradeoff between quality of output waveforms and switching losses. This study generalizes the existing optimal switching sequences for total harmonic distortions (THDs) and switching losses for different modulation indexes and reference angles with a parameter called quality factor. This factor provides a common platform in which the THDs and switching losses of different SVPWM techniques can be compared. The optimal spatial distribution of each sequence is derived on the basis of the quality factor to minimize harmonic current distortions and switching losses in a sector; the result is the minimum ripple loss SVPWM (MRSLPWM). By employing the sequences from optimized switching maps, the proposed method can simultaneously reduce THDs and switching losses. Two hybrid SVPWM techniques are proposed to reduce line current distortions and switching losses in motor drives. The proposed hybrid SVPWM strategies are MRSLPWM 30 and MRSLPWM 90. With a low-cost PIC microcontroller (PIC18F452), the proposed hybrid SVPWM techniques and the quality of output waveforms are experimentally validated on a 2 kVA VSI based on a three-phase two-level insulated gate bipolar transistor.

SVPWM 방식 마이크로소스로 구성된 마이크로그리드 모델링 및 해석 (Modeling and Analysis of the Micro-Grid with SVPWM Micro-Sources)

  • 손광명;이계병;김영섭
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.12-19
    • /
    • 2006
  • 마이크로소스는 1[kW]${\sim}$수[MW] 사이의 전력을 공급하고, 기존의 대규모 발전설비보다 높은 신뢰도와 에너지 효율을 가지는 고품질의 전력을 공급할 수 있다. 본 논문에서는 마이크로소스의 스위칭레벨 모델을 개발하였으며, 다수의 마이크로소스가 전력시스템과 연계되어 마이크로그리드를 형성할 경우의 특성에 대하여 연구하였다. 마이크로소스는 인버터의 효율을 극대화 할 수 있도록 공간벡터 펄스폭변조(Space Vector PWM, SVPWM) 기법을 채용하였으며, 마이크로소스의 제어시스템 파라미터 특성 및 마이크로소스 상호작용에 관하여 연구하였다. 마이크로소스는 PSCAD/EMTDC를 이용하여 구현하였으며 이를 이용해 마이크로그리드를 구성하여 시뮬레이션하였다. 사례 연구를 통하여 제안된 모델의 효용성을 확인하였다.

PV 시스템을 이용한 단상유도전동기의 벡터제어 (Voctor Control of Single Phase Induction Motor using PV system)

  • 고재섭;최정식;정병진;김도연;박기태;최정훈;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.195-197
    • /
    • 2007
  • The water pumping system uses a variable speed single phase induction motor driven a centrifugal pump by field oriented control(FOC) inverter. The MPPT using a DC-DC converter controlled the duty cycle to track maximum power from PV under different insolation conditions. The duty cycle directly relate with a flux producing current control($i_{ds}$). The FOC inverter uses a current control voltage source inverter(CC-VSI). The simulation results are shown that the characteristics and performance of drive system, which varies as each conditions of light by expresses in voltage$(V_{dq})$, current$(I_{dq})$, speed of motor and torque.

  • PDF

Extension of the Operating Speed for Vector-Controlled Induction Machine Drives in the Overmodulation Range

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.477-486
    • /
    • 2012
  • This paper proposes a novel current control scheme for vector-controlled induction machine (IM) drives in the overmodulation (OVM) range, with which the voltage utilization of the voltage-source inverter (VSI) can be maximized. In the OVM region, the original voltage reference is modified by changing its magnitude and angle, which causes the motor current to be distorted, resulting in a deterioration of the current control performance. To meet with this situation, the harmonic components in the feedback currents should be eliminated before being input to the PI current controllers. For this, a composite observer is applied to extract the fundamental and harmonic components from the distorted currents, which gives a good performance without a delay and the effect of a fundamental frequency variation. In addition, through a detailed analysis of the response of the PI current controllers in the OVM range, the effectiveness of using the composite observer is demonstrated. Simulation and experimental results for a 3-kW induction motor drive are shown to verify the validity of the proposed method.

STATCOM의 출력전압 구현방식에 따른 동특성 해석 (The Dynamic Characteristics Analysis of the STATCOM According to the Realization of the STATCOM Output Voltage)

  • 김선호;원동준;한학근;이송근;문승일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.323-331
    • /
    • 2000
  • Recently Advanced Static Var Compensators(ASVC) or STATic Synchronous COMpesator(STATCOM) has been considered as a next generation reactive power controller. The STATCOM is a voltage source inverter(VSI) based on the static VAr compensator with only small capacitors on the dc side. The main function of the STATCOM is to keep the bus voltage magnitude at the desired value. This paper compared the PAM STATCOM with the PWM STATCOM. The characteristics and the control method of each model is analyzed. And the simulation of STATCOMs based on the above two methods is presented.

  • PDF

Low Cost FPGA-based Control Strategy for a Single Phase Stacked Multicell Converter

  • Aguillon-Gracia, Jacobo;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.408-410
    • /
    • 2005
  • Multilevel converters have emerged like a new strategy for energy conversion from medium power to high power. The main characteristic of the topologies classified as multilevel, is the use of commutation devices connected in series, allowing the distribution of the voltage and reducing stress in the commutation switches. Stacked Multicell Converter (SMC), is classified as single-phase voltage source inverter(VSI). Due to the fact, the SMC generates a signal of alternating current of several levels of voltage of direct current. The following work will demonstrate the flexibility of the above mentioned topology using a low cost control circuit architecture.

  • PDF