• 제목/요약/키워드: voltage capacity

검색결과 979건 처리시간 0.027초

감쇠파 고주파전압의 선행방전을 이용한 Plasma jet의 전기적 기동특성에 대한 실험적 연구 (The Experimental Research On The Electrical Characteristics For The Ignition Of Plasma Jet Using The Advance Discharge Of High Frequency Voltage With Attenuation)

  • 전춘생
    • 전기의세계
    • /
    • 제21권4호
    • /
    • pp.27-38
    • /
    • 1972
  • This paper discusses the characteristics about the ignition of D.C. main discharge is a plasma jet generator, manufactured for trial as non-transferred type, when the electrical energy appropriate to the ignition is supplied to the gap between the electrodes by using advance discharge of attenuating high frequency voltage generated by a high frequency oscillator with mercury spark gap. These characteristics are under the influences of (a) the length of mercury gap in high frequency oscillator and the quantity of hydrogen flow supplied to it, (b) the condenser capacity of the high frequency oscillator circuit, (c) the length of plasma jet torch in D.C. main discharge circuit and the quantity of argon flow supplied to it, (d) the circuit constants of D.C. main discharge circuit. The results for these characteristics, obtained by this research, are considered to be helpful to the designs for the ignition of a plasma jet as well as the welding arc stabilizer by high frequency discharge and the high frequency arc welder.

  • PDF

전원분할 커패시터 용량변화에 따른 ZVS-HB형 DC-DC 컨버터의 특성해석 (A Characteristic Analysis of ZVS-Half Bridge Type DC-DC Converter with Source Division Capacitor capacity variety)

  • 오경섭;남승식;김동희;노채균;배영호;노철균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1318-1320
    • /
    • 2000
  • In this paper, DC/DC converter has been composed of a capacitor which has not only a source division function but a resonant function instead of a previous source division capacitor. In addition to the proposed circuit is introduced a soft switching technique (ZVS). The proposed paper certified that theoretical waveforms are equal to experiment waveforms of power, output voltage, voltage ripple etc. and to be possible to control using division ratio.

  • PDF

FRIENDS(Flexible Reliable Intelligent Electrical eNergy Delivery System)를 이용한 배전계통의 효율적인 운용방안 개발 (A study on the distribution system using Flexible Reliable Intelligent Electrical eNergy Delivery System)

  • 김용하;이형노;조재한;노대석;이범;최상규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1059-1062
    • /
    • 1998
  • This paper which can simulate FRIENDS(Flexible Reliable Intelligent Electrical eNergy Delivery System) model of distribution electrical system presents a new algorithm. In the operation of FRIENDS model, dispersed energy storage(DES) systems have an important role. We can use the active and reactive power of DES to control customer's voltage. In this, the former means load levelling operation and the later means voltage control operation of DES. We focus our research on load levelling operation of DES. We develope an algorithm to get an optimal capacity and operation schedule of DES and then apply it to the FRIENDS model. The results show the effectiveness of the proposed method.

  • PDF

BLDC 전동기를 사용한 전기 스쿠터 개발 (An electric scooter development using BLDC motor)

  • 박성욱;이득기
    • 전기학회논문지P
    • /
    • 제51권4호
    • /
    • pp.219-221
    • /
    • 2002
  • This paper presents an electric scooter development using blushless DC motor. In recent scooters was to develop for sport leisure and short transportation. Most of scooter are used petroleum gas. This gas scooter has disadvantage to pollute the air. Some of scooters have developed by DC motor which require a brush. However brushless motors have higher maximum speed and greater capacity, save maintenance labour and produce less noise. There is also greater freedom in planing the usage of brushless motors. In this paper we develop an electric scooter driving BLDC motor for design smart system and control speed of scooter with current reference signal to apply voltage to motor by means of three phase inverter. Using accelerator device we generate current reference to control speed and send the current to a MICOM by A/D converter. This MICOM produces the voltage signal and hall sensors signal and PWM controller drive three phase inverter to minimize error between the reference and an actual current.

A Phase-shifter for Regulating Circulating Power Flow in a Parallel-feeding AC Traction Power System

  • Choi, Kyu-Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1137-1144
    • /
    • 2014
  • A parallel-feeding AC traction power system increases the power supply capacity and decreases voltage fluctuations, but the circulating power flow caused by the phase difference between the traction substations prevents the system from being widely used. A circuit analysis shows that the circulating power flow increases almost linearly as the phase difference increases, which adds extra load to the system and results in increased power dissipation and load unbalance. In this paper, we suggest a phase shifter for the parallel-feeding AC traction power system. The phase shifter regulates the phase difference and the circulating power flow by injecting quadrature voltage which can be obtained directly from the Scott-connection transformer in the traction substation. A case study involving the phase shifter applied to the traction power system of a Korean high-speed rail system shows that a three-level phase shifter can prevent circulating power flow while the phase difference between substations increases up to 12 degrees, mitigate the load unbalance, and reduce power dissipation.

전기자동차용 납축전지의 시분할 균등충전기 (Time-sharing Charge System for Equalization of Lead-Acid Battery)

  • 강신영;김광헌;임영철
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권2호
    • /
    • pp.94-101
    • /
    • 1997
  • 본 논문에서는 일정 주기마다 전지의 단자전압을 검출하여 단자전압에 따라 균등충전 시간을 시분할로 제어하여 전지간의 불균등을 해소시키는 균등 충전방식을 제안하였다. 기존의 균등 충전방식과 달리 구조가 간단하고 소형, 경량으로 전지자동차용 탑재형 균등 충전시스템으로 이용이 가능하다. 또한, 원칩 마이크로프로세서를 이용하여 일정 주기마다 단자전압을 검출하여 제어하므로 전지의 과충전을 예방할 수 있고, 따라서 전지 수명 연장에도 효과적이라 할 수 있다.

  • PDF

4MW급 고압 인버터 시스템 개발 (Development of 4MW Class High Voltage Inverter System)

  • 박영민;한기준;최세경;정명길;이세현;김남해;이교범;송중호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.352-355
    • /
    • 2001
  • This paper makes a general description of the results at government project which were peformed for several years. Through this project, the real capacity of 3.3KV/4MW Class 3 Level Voltage Source Inverter System were designed and the characteristics of its proto type were analyzed, moreover the web based IIMS(Inverter Information Management System) and Virtual Operation Simulator was developed. Now, this system is running for field application test.

  • PDF

Determining Optimal Custom Power Devices to Enhance Power Quality

  • Won Dong-Jun;Moon Seung-Il
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.280-285
    • /
    • 2005
  • This paper proposes a novel method for determining the kind and rating of power quality solutions. To determine the kind of solution, event cause and direction are utilized. According to the event cause and direction, an adequate type of solution is determined for effective compensation. To rate the required capacity of solution, the concept of lost energy is adopted. Lost voltage, lost power and lost energy are calculated and the rating of the solution is determined to compensate a specific event. The rating method that utilizes the result of stochastic diagnosis is also proposed. A power quality index such as CP95 is adopted for solution suggestion. The method developed in this paper is applied to the test system and proved to be useful for enhancing the power quality of the customer system. It can provide customers with information pertaining to what is a proper and cost-effective solution among various compensating devices.

분광기법을 이용한 저압 차단기용 소호재료 특성연구 (Investigation of Arc Quenching Material for Low Voltage Circuit Breaker using Spectroscopic Method)

  • 이상엽;정영우;박홍태;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1665-1667
    • /
    • 2003
  • Recently, a breaking capacity increases with breaking method using gas pressure from ablation materials in low voltage circuit breakers. In this paper, we investigated arc quenching materials with spectroscopic method. Especially, Hydrogen spectrum was investigated because its dielectric characteristics are better than other gases. We selected two arc quenching materials, UP and PA6, that use in circuit breakers. They had hydrogen spectrums, but PA6 was better than UP in the qualitative aspect.

  • PDF

바리스터와 LC필터를 사용한 2단 서지보호장치 (Two-Stage Surge Protection Device with Varistor and LC Filter.)

  • 이복희;김지훈;이경옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.279-281
    • /
    • 1996
  • This paper deals with the two stage surge protection device by using varistor and LC low pass filter. Recently varistor alone has been used with overvoltage protection devices for the AC power mains and has same problems associated with high remnant voltage and noise. In this work, in order to improve the cutoff performance of surge protection device, the lightning surge protection device having two stage hybrid circuit for an AC single phase mains was designed and fabricated. Operation characteristics and surge clamping performance of the surge protection device in an $8/20{\mu}s$ surge current are investigated. As a consequence, it is found that the proposed two stage surge protective device for AC power mains has a variety of advantages such as a smaller clamping voltage, high frequency noise reduction and large clamping capacity.

  • PDF