• Title/Summary/Keyword: voltage capacity

Search Result 978, Processing Time 0.026 seconds

QUALIFICATION, CONDITION MONITORING, AND MANAGEMENT OF AGEING OF LOW VOLTAGE CABLES IN NUCLEAR POWER PLANT (Global Today - 원자력발전소 저전압 케이블의 노화에 대한 적격, 상태 모니터링 및 관리 (1))

  • Kang, Ki Sig
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.451
    • /
    • pp.46-58
    • /
    • 2014
  • At the end of 2013, there were 434 nuclear power reactors in operation worldwide, with a total capacity of 371.6 GW(e), approximately 80 % had been in service 20 years and more. Many Member States have given high priority to licensing their nuclear power plants to operate for terms longer than the time frame originally anticipated(e.g. 30 or 40 years). One of challenges for long term operation is cable ageing management. How can qualify the existing cable under harsh environment in nuclear power plant? The paper described the approaches on qualification, condition monitoring, and management of low voltage cables in nuclear power plant.

  • PDF

Turn-on Loss Reduction for High Voltage Power Stack Using Active Gate Driving Method

  • Kim, Jin-Hong;Park, Joon Sung;Gu, Bon-Gwan;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.632-642
    • /
    • 2017
  • This paper presents an improved approach towards reducing the switching loss of insulated gate bipolar transistors (IGBTs) for a medium-capacity-class power conditioning system (PCS). In order to improve the switching performance, the switching operation is analyzed, and based on this analysis, an improved switching method that reduces the switching time and switching loss is proposed. Compared to a conventional gate drive scheme, the switching loss, switching time, and delay are improved in the proposed gate driving method. The performance of the proposed gate driving method is verified through several experiments.

Implementation of Inverter Systems for DC Power Regeneration

  • Kim Kyung-Won;Yoon In-Sic;Seo Young-Min;Hong Soon-Chan;Yoon Duck-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.126-131
    • /
    • 2001
  • This paper deals with implementation of inverter systems for DC power regeneration, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, a three-phase square-wave inverter system is adopted. To control the regenerated power, the magnitude and phase of fundamental output voltages should be appropriately controlled in spite of the variation of input DC voltage. Inverters are operated with modified a-conduction mode to fix the potential of each arm. The overall system consists of the line-to-line voltage and line current sensors, an actual power calculator using d-q transformation method, a complex power controller with PI control scheme, a gating signal generator for modified $\alpha-conduction\;mode\;with\;\delta\;and\;\alpha$, a DPLL for frequency followup, and power circuit.

  • PDF

Assembling and Insulation Test of 1MVA Single Phase HTS Transformer for Power Distribution

  • Kim, S. H.;Kim, W. S.;Kim, J. T.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Lee, S. J.;S. Hahn
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.30-33
    • /
    • 2003
  • 1MVA high temperature superconducting (HTS) transformer with double pancake windings made of BSCCO-2223 HTS tapes was designed and manufactured. And prototype transformer with the same capacity was manufactured also. The each rated voltage of the HTS transformer is 22.9 kV and 6.6 kV. Four parallel BSCCO-2223 HTS tapes were wound in the double pancake windings of low voltage side. In order to distribute the currents equally in each HTS tapes, the three times transposition was performed between the double pancake windings. The windings of prototype transformer were wound using copper tape with the same size as BSCCO-2223 HTS tape. The core of the transformer was designed and manufactured as a shell type core made of laminated silicon steel plate. The several characteristics tests for the prototype transformer were performed in liquid nitrogen and insulation tests were accomplished also.

A Study on the Transient Analysis of 2[MVA] Mold Transformer for Electric Field (2[MVA] 배전용 몰드변압기의 과도전계해석에 관한 연구)

  • Jeon, Mun-Ho;Kim, Chang-Eob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.171-176
    • /
    • 2010
  • This paper presents the electric field for 22.9[kV]/380[V], 2[MVA] mold transformer are analysed using FEM(finite element method). The electric field was calculated for the voltage applied to the transformer. Then, it is analysed that the maximum electric field occurred between high voltage turns. Capacitance is calculated with energy method. Surge impulse test simulation is studied by modeling circuit with capacitance and inductance. This paper obtain the result that is about influence of electric field in distribution mold transformer adopted.

A Study on Methods of Interference Avoidance between Power Line Communications and Radio Communications (고속전력선통신과 무선통신간의 간섭 회피 방법에 대한 연구)

  • Jang, Dong-Won;Lee, Young-Hwan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.223-226
    • /
    • 2007
  • This paper first outlines the technology used in Power Line Communications(PLC) systems, and the political support being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this interference avoidance/mitigation. Nevertheless, PLC has several features that mean that it is capable of creating such interference. These features are discussed, and some published field trial results are reviewed. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC system mean that there is no consensus as yet as to how PLC system components can be made compliant with EMC requirements. It is concluded that there is little prospect of an accommodation between the competing demands, so that if PLC is to become widespread it will be at the expense of the radio environment.

  • PDF

A Study on Characteristic of Electric Apparatus for High Speed Train (고속철도차량 전기장치의 특성에 관한 연구)

  • Han, Young-Jae;Kim, Ki-Hwan;Park, Choon-Soo;Kim, Jin-Hwan;Kim, Hyun;Min, Pyeong-O
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.435-437
    • /
    • 2003
  • Recently, as the road capacity reaches the limit and environmental problems becomes serious, there is gradually increased a need for railroad vehicles that are environment-friendly and have time regularity, reliability and safety. Accordingly, in addition to conventional railroad vehicles, lots of vehicles are being newly developed. We developed the hardware and software of the measurement system for on-line test and evaluation of korean hish speed train. The software controls the hardware of the measurement data and acts as interface between users and the system hardware. In this paper, we is studied for electric apparatus performance of railway vehicle using sensor. In order to this test is developed signal conversion system. Using this system, we obtained important result for pantograph voltage, battery voltage, axle speed, and running speed.

  • PDF

Analysis of Industrial Battery lifetime Using Instantaneous Discharge Test (순간방전 시험에 의한 산업용 축전지 잔존수명 분석)

  • Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok;Kim, Sun-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.123-124
    • /
    • 2008
  • Battery is one of the emergency power. Battery reliability is a very important to keep up the minimum of building capabilities in case of interruption of electric power. Instantaneous discharge test is carried out for measuring transient voltage change(${\Delta}V$) and internal instantaneous impedance(Z), and then it is compared with discharge test results for the estimating the battery capacity. As a result, it was confirmed that the voltage change(${\Delta}V$) and the instantaneous impedance of the batteries failed in actual discharge test were higher that those of the sound batteries. Such an instantaneous discharge test can be a diagnosis of battery sound.

  • PDF

An Study for reuse of the waste lead battery using Pulse Charger with mode conversion type (모드 전환형 펄스충전기론 이용한 폐납축전지 재활용에 관한 연구)

  • Shin, Choon-Shik;An, Young-Joo;Kim, Sang-Dong;Shin, Young-Mi;Kim, Jong-Dal;Kim, Dong-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.101-107
    • /
    • 2007
  • In this paper, the pulse charger with mode consersion type is proposed that can reuse the waste lead battery. The pulse charger uses the switch mode of the forward convert method. The pulse charger maintain the constant voltage in state removing the lead battery and when it connected the pulse charger, it is converted the charge mode of the constant current immediately. It continues the rapid charge until the full state of the lead battery. After that the pulse charger is converted to the charge mode of constant voltage automatically, and then it continues the normal charge. The experiment results show that the effectiveness of pulse charger such as the good performance and the prolonged durability in lead battery according to capacity states.

  • PDF

Application of the RC Filter for Suppressing the Output Overvoltage of the High-voltage Large-capacity Inverter (고압 대용량 인버터의 출력 과전압 억제를 위한 RC filter의 현장적용 시험에 관한 연구)

  • Woo, Myung-Ho;Park, Young-Min;Lee, Se-Hyun;Min, Byung-Duk;Seo, Kwang-Duk
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.962-964
    • /
    • 2001
  • In this paper, the RC filter for mitigating the output overvoltage of the 3-level 3300V 4MW inverter is described. The descriptions on power circuit and overvoltage phenomena are presented. The output transformer which may be used to obtain the higher output voltage, makes the filter design difficult because the parameter measurements are not easy and the accuracy may be poor. So, this paper presents several preliminary results on the output overvoltage with or without transformer to investigate the overall system characteristics. Some experimental results are also provided when the designed filter is applied.