• 제목/요약/키워드: visual fixation

검색결과 189건 처리시간 0.022초

시선의 고정과 도약에 나타난 공간정보 탐색 특성 (Spatial Information Search Features Shown in Eye Fixations and Saccades)

  • 김종하
    • 한국실내디자인학회논문집
    • /
    • 제26권2호
    • /
    • pp.22-32
    • /
    • 2017
  • This research is to analyze the spatial information search features which shown by Eye fixation and movement and conducted eye tracking experiment for targeting sports shop spatial images which it are same but looks different. This is able to find out the eye movement feature according to placement of goods from the eye movement and movement distance of spatial visitor, and the result can be defined as following. First, the whole original-reverse left / right images have a higher number of observations in the [IN] area than in the [OUT] area. This is because after eye taking high observations in LA area of [IN] have been jump-over [OUT], performed search activities in low eye fixation without high eye fixation. Second, there was a difference in the frequency of the observation data as the composition of the images changed. The original image has been often fixed the eyes in LA area, and the one that has been observed for a long time is reverse left / right image. Also, fixation point was shown higher at the reverse left / right image as jump-over from [OUT] area to [IN] area. If LA area seen as reverse left / right image, it is located in right-hand side. The case where the dominant area is on the right side has a characteristic that the eye fixation is longer. This can be understand that the arrangement of products for attract the customer's attention in the commercial space might be more effective when it is on the right side. Third, the moving distance(IN ${\rightarrow}$ OUT) of the sight pointed to external from LA area was long in the both original-reverse left / right images, but it is no relation with search direction([IN${\rightarrow}$OUT] [IN${\rightarrow}$OUT]) of the sight. In other words, the sight that entered in LA area can be seen as visual perception activity for re-searching after big jump-over, in the case go in to outward (OUT area) after searching for more than certain time. The fact that the moving distance of eye is relatively short in the [IN ${\rightarrow}$ OUT] process considered as that the gaze that stays outside the LA area naturally enters in to LA area.

Test Chart 2000 Pro와 한국 표준 검안법의 일치도 비교 연구 (A Comparative Study between Korean Standard Eye Test and Test Chart 2000 Pro)

  • 강지훈;김달영
    • 한국안광학회지
    • /
    • 제14권1호
    • /
    • pp.69-80
    • /
    • 2009
  • 목적: 본 연구는 영국에서 개발된 컴퓨터 모니터용 검안프로그램 Test Chart 2000 Pro의 타당도(validity)를 평가하기 위해 수행되었다. 방법: Test Chart 2000 Pro와 한국표준검안법의 공통된 10종류 검안항목에 대하여, 각 항목별로 동일한 피실험자군을 대상으로 2가지 검안법을 함께 실시하고, 측정결과의 일치도를 비교분석하였다. 결과: 10종류의 비교실험 중 Snellen Chart, Cross-cyl Target, Duochrome Test, Fan and Block Test, Random Dot Stereograms에서는 한국표준검안법과 Test Chart 2000 Pro양측의 결과가 통계적으로 유의미한 일치를 보였으나, LogMar Chart, Single Letter Chart, Phoria Test, Fixation Disparity Test, Worth 4 Dot Test에서는 두 검안 방법의 결과에서 차이가 나타났다. 결론: 한천석 시력표와 포롭터로 이루어진 한국표준검안법을 기준으로 했을 때 Test Chart 2000 Pro의 타당도는 높지 않으며, 측정의 정확도 측면에서 개선이 요구된다.

  • PDF

한국인 청년의 자발적 순목에 관한 연구 (Study of spontaneous blinking for Korean young people)

  • 김상문
    • 한국안광학회지
    • /
    • 제7권2호
    • /
    • pp.101-105
    • /
    • 2002
  • 정상 한국인 청년 60명(남 30명, 여 30명)의 시각활동 및 환경요인에 따른 순목을 측정하였다. 남 여 각각의 자발적 blink rate는 $19.2{\pm}2.0/min$$18.7{\pm}2.0/min$이었고 남자가 약간 더 많았다. 여성에서 contact lens 착용에 따른 blink rate 및 남 여의 시력에 따른 blink rale의 차이는 없었다. 자발적 순목은 시각활동 및 바람과 같은 환경조건에 따라 변하였으나 빛의 세기에 따라서는 유의성 있는 변화를 나타내지 않았다. 주시의 강도가 강할수록 자발적 순목회수는 평상시보다 낮은 반면 바람의 세기가 강할수록 자발적 순목회수는 평상시보다 높았다.

  • PDF

Internal Fixation Using Clavicle Hook Plates for Distal Clavicle Fractures

  • Kim, Kwang-Yul;Kim, Hyung-Chun;Cho, Sung-Jun;Ahn, Su-Han;Kim, Dong-Seon
    • Clinics in Shoulder and Elbow
    • /
    • 제18권1호
    • /
    • pp.21-27
    • /
    • 2015
  • Background: To report the radiological and clinical outcomes of internal fixation using distal clavicle hook plates for distal clavicle fractures. Methods: From April 2008 to December 2012, 32 patients with distal clavicle fractures underwent surgery using an AO hook plate. The reduction was qualified and evaluated according to the radiological findings. The evaluation of the clinical outcomes was performed with the University of California at Los Angeles (UCLA) score, the Korean Shoulder score, and the visual analogue scale (VAS) pain score. Results: By radiological evaluation, we found that 31 of 32 patients showed anatomical reduction and solid bone union. Although we obtained satisfactory UCLA scores, Korean Shoulder Scale scores, and VAS pain scores, 12 cases of complications were present. We found 4 cases of osteolysis of the acromion, 1 case of nonunion, 3 cases of periprosthetic fractures, 3 cases of subacromial pain, and 1 case of skin irritation. We performed re-operations in 2 patients. Conclusions: To avoid complications associated with clavicle hook plates, choosing the appropriate hook size and bending of the hook according to the slope of the acromion undersurface is critical. Also, we believe that early removal of clavicle plates may help reduce complications.

Unrecognized bony Bankart lesion accompanying a dislocated four-part proximal humerus fracture before surgery: a case report

  • Lee, Seungjin;Shin, Daehun;Hyun, Yoonsuk
    • Clinics in Shoulder and Elbow
    • /
    • 제25권1호
    • /
    • pp.68-72
    • /
    • 2022
  • Proximal humerus fractures are the third most common fractures, totaling 4% to 5% of all fractures. Here, we present the case of a 39-year-old man with a dislocated four-part fracture of the proximal humerus with a huge bony Bankart lesion. Preoperatively, the bony Bankart lesion of the glenoid was not visualized on computed tomography scans or magnetic resonance imaging because the fracture of the proximal humerus was comminuted, displaced, and complex. It was planned for only the humerus fracture to be treated by open reduction and internal fixation using a locking plate. However, a fractured fragment remained under the scapula after reduction of the dislocated humeral head. This was mistaken for a dislocated bone fragment of the greater tuberosity and repositioning was attempted. After failure, visual confirmation showed that the bone fragment was a piece of the glenoid. After reduction and fixation of this glenoid part with suture anchors, we acquired a well-reduced fluoroscopic image. Given this case of complex proximal humerus fracture, a glenoid fracture such as a bony Bankart lesion should be considered preoperatively and intraoperatively in such cases.

도시가로환경 구성요소의 우선순위에 관한 연구 - 아이트래킹 실험을 통한 관심영역설정 분석을 중심으로 - (A Study on the Priorities of Urban Street Environment Components - Focusing on An Analysis of AOI (Area of Interest) Setup through An Eye-tracking Experiment -)

  • 이선화;이창노
    • 한국실내디자인학회논문집
    • /
    • 제25권1호
    • /
    • pp.73-80
    • /
    • 2016
  • Street is the most fundamental component of city and place to promote diverse actions of people. Pedestrians gaze at various street environments. A visual gaze means that there are interesting elements and these elements need to be preferentially improved in the street environment improvement project. Therefore, this study aims to set up the priorities of street environment components by analyzing eye movements from a pedestrian perspective. In this study, street environment components were classified into road, street facility, building(facade) and sky and as street environment images, three "Streets of Youth" situated in Gwangbok-ro, Seomyeon and Busan University of Busan were selected. The experiment targeted 30 males and females in their twenties to forties. After setting the angle of sight through a calibration test, an eye-tracking experiment regarding the three images was conducted. Lastly, the subjects were asked to fill in questionnaires. The following three conclusions were obtained from the results of the eye-tracking experiment and the survey. First, building was the top priority of street environment components and it was followed by street facility, road and sky. Second, as components to be regarded as important, fast 'Sequence', many 'Fixation Counts' and 'Visit Counts', short 'Time to First Fixation' and long 'Fixation Duration' and 'Visit Duration' were preferred. Third, after voluntary eye movements, the subjects recognized the objects with the highest gaze frequency and the lowest gaze frequency.

Polyetheretherketone Cage with Demineralized Bone Matrix Can Replace Iliac Crest Autografts for Anterior Cervical Discectomy and Fusion in Subaxial Cervical Spine Injuries

  • Kim, Soo-Han;Lee, Jung-Kil;Jang, Jae-Won;Park, Hyun-Woong;Hur, Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권2호
    • /
    • pp.211-219
    • /
    • 2017
  • Objective : This study aimed to compare the clinical and radiologic outcomes of patients with subaxial cervical injury who underwent anterior cervical discectomy and fusion (ACDF) with autologous iliac bone graft or polyetheretherketone (PEEK) cages using demineralized bone matrix (DBM). Methods : From January 2005 to December 2010, 70 patients who underwent one-level ACDF with plate fixation for post-traumatic subaxial cervical spinal injury in a single institution were retrospectively investigated. Autologous iliac crest grafts were used in 33 patients (Group I), whereas 37 patients underwent ACDF using a PEEK cage filled with DBM (Group II). Plain radiographs were used to assess bone fusion, interbody height (IBH), segmental angle (SA), overall cervical sagittal alignment (CSA, C2-7 angle), and development of adjacent segmental degeneration (ASD). Clinical outcome was assessed using a visual analog scale (VAS) for pain and Frankel grade. Results : The mean follow-up duration for patients in Group I and Group II was 28.9 and 25.4 months, respectively. All patients from both groups achieved solid fusion during the follow-up period. The IBH and SA of the fused segment and CSA in Group II were better maintained during the follow-up period. Nine patients in Group I and two patients in Group II developed radiologic ASD. There were no statistically significant differences in the VAS score and Frankel grade between the groups. Conclusion : This study showed that PEEK cage filled with DBM, and plate fixation is at least as safe and effective as ACDF using autograft, with good maintenance of cervical alignment. With advantages such as no donor site morbidity and no graft-related complications, PEEK cage filled with DBM, and plate fixation provide a promising surgical option for treating traumatic subaxial cervical spine injuries.

Therapeutic Effect of Teriparatide for Osteoporotic Thoracolumbar Burst Fracture in Elderly Female Patients

  • Yu, Dongwoo;Kim, Sungho;Jeon, Ikchan
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권6호
    • /
    • pp.794-805
    • /
    • 2020
  • Objective : Teriparatide is known as an effective anabolic agent not only for severe osteoporosis but also for bone healing and union. We explored the possibility of teriparatide as an alternative treatment option for osteoporotic thoracolumbar (TL) burst fracture. Methods : This retrospective study enrolled 35 female patients with mean age of 73.77±6.71 years (61-88) diagnosed as osteoporotic TL burst fracture with ≥4 of thoracolumbar injury classification and severity (TLICS) score and no neurological deficits. All patients were treated by teriparatide only (12 of group A), teriparatide plus vertebroplasty (12 of group B), or surgical fixation with fusion (11 of group C), and followed up for 12 months. Radiological outcomes were evaluated using radiological parameters including kyphotic angle (KA), segmental vertebral kyphotic angle (SVKA), compression ratio (CR), and vertebral body height (anterior [AH], middle [MH], posterior [PH]). Functional outcomes were evaluated using visual analog scale (VAS) and Macnab classification (MC). Results : There were no statistical significant differences in age, bone mineral density (-3.36±0.73), and TLICS score (4.34±0.48) among the three groups (p>0.05). Teriparatide was administered during 8.63±2.32 months in group A and B. In 12-month radiological outcomes, there were significant restoration in SVKA, CR, AH, and MH of group B and KA, SVKA, CR, AH, and MH of group C compared to group A with no radiological changes (p<0.05). All groups showed similar significant improvements in 12-month functional outcomes, although group B and C showed a better 1-month VAS, 1-month MC, 3-month MC compared to group A (p<0.05). Conclusion : Non-surgical treatment with teriparatide showed similar 12-month functional outcomes compared to surgical fixation with fusion. The additional vertebroplasty to teriparatide and surgical fixation with fusion were more helpful to improve short-term functional outcomes with structural restoration compared to teriparatide only.

다발성 Kirschner 강선을 이용한 제 5중족골 기저부 골절의 수술적 치료 (Surgical Treatment of the Fifth Metatarsal Base Fracture Using Multiple Kirschner Wires)

  • 김지형;김장우;이정익;김상길;이승환
    • 대한족부족관절학회지
    • /
    • 제18권1호
    • /
    • pp.24-28
    • /
    • 2014
  • Purpose: The purpose of this study is to evaluate the clinical and radiographic results of internal fixation using multiple Kirschner wires (K-wires) for the fifth metatarsal base fracture. Materials and Methods: We retrospectively reviewed 14 patients with a displaced fifth metatarsal base fracture. We measured the distance of fracture displacement on the foot oblique radiograph pre- and post-operatively. We evaluated the clinical results using the visual analog pain scale at six weeks and three months postoperatively and the American Orthopaedic Foot and Ankle Society (AOFAS) mid-foot score at six months postoperatively. Results: In our series, 10 cases were zone I fracture and four cases were zone II fracture. We achieved anatomical reduction and bony union in all of our cases. The average time to bone union was 43 days. The degree of pain around the fifth metatarsal base was significantly decreased after surgery. The average AOFAS score was 95 at six months postoperatively. Conclusion: Multiple K-wire fixation is a relatively simple fixation method for displaced fifth metatarsal base fractures. If we place a K-wire into the medial cortex of the fifth metatarsal, we could prevent proximal migration of the K-wire.

경도-중등도 무지외반증 환자의 생체 흡수성 마그네슘 나사못과 티타늄 나사못을 사용한 수술의 단기 결과 비교 (Comparing the Results of Using Bioabsorbable Magnesium Screw with Those Using a Titanium Screw for the Treatment of Mild to Moderate Hallux Valgus: Short-term Follow-Up)

  • 홍성엽;김갑래;한우솔
    • 대한족부족관절학회지
    • /
    • 제24권3호
    • /
    • pp.107-112
    • /
    • 2020
  • Purpose: Hallux valgus (HV) is a common foot deformity that causes pain in the first metatarsophalangeal joint. Distal metatarsal osteotomies are commonly performed as a treatment. This retrospective study compared the clinical and radiological results of bioabsorbable magnesium (Mg) versus titanium (Ti) screw fixation for modified distal chevron osteotomy in HV. Materials and Methods: Forty-nine patients, who underwent modified distal chevron osteotomy for HV in 2018 and 2019, were reviewed retrospectively. Bioabsorbable Mg screw fixation was applied in 20 patients (22 feet), and a traditional Ti compression screw was applied in 29 patients (40 feet). The patients were followed up for at least six months. The clinical results were evaluated using the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal (AOFAS-MTP-IP) scale and a visual analogue scale (VAS). The hallux valgus angle (HVA), intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) were measured before, after surgery, and at the six months follow-up. Results: The AOFAS-MTP-IP scale and VAS points were improved in both groups, with no significant difference between them. At the six-month follow-up, HVA, IMA, and DMAA were similar. Bone union was confirmed in both groups, and there were no significant major complications in both groups. Four people in the Ti screw group underwent implant removal surgery. Conclusion: Bioabsorbable Mg screws showed comparable clinical, radiologic results to Ti standard screws six months after distal modified chevron osteotomy. These screws are an alternative fixation material that can be used safely and avoid the need for implant removal operations.