• Title/Summary/Keyword: visual acuity test

Search Result 134, Processing Time 0.018 seconds

The Study of Visual Fatigue by Monitor Letter Contrast with an Eye Tracker (아이트래커를 이용한 모니터 글자 대비도에 따른 눈의 피로도 연구)

  • Kim, Ha-Rim;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.533-538
    • /
    • 2014
  • Purpose: This study is to investigate correlation between eye fatigue and letter contrast according to letter contrast changes on monitor display. Methods: Reading speed test were carried out for 53 subjects (mean age: $22.68{\pm}1.85$ years) who have over Best-corrected visual acuity (BCVA) 1.0, and 45 subjects, who could read over 123 out of 163 letters among 53 subjects were selected. They were asked to read the letters which were composed of Black (contrast 100%), Dark gray (contrast 80%), Gray (contrast 80%), Light gray (contrast 30%) randomly. The change of their eye fatigue by letter contrast on monitor display was measured by monitoring their eyes with an eye-tracker while they were reading letters. Results: Event Duration (sec) was 33.635 for Black, 32.266 Dark gray, 33.936 for Gray, and 34.848 for Light gray. Average of Fixation Duration (sec) was 0.224 for Black, 0.218 for Dark gray, 0.239 for Gray and 0.243 for Light gray. Average of Pupil diameter (mm) was 41.133 mm for Black, 41.160 mm for Dark gray, 40.880 mm for Gray and 40.459 mm for Light gray. Frequency (blinks/sec) was 0.211 for Black, 0.206 for Dark gray, 0.221 for Gray, and 0.238 for Light gray. Conclusions: Event Duration and average of Fixation Duration were the shortest for Dark gray and the longest for Light gray. In average Pupil diameter was the biggest Dark gray and the smallest for Light gray. Blink Frequency (blinks/sec) was the lowest for Dark gray and the highest for Light gray. Visual fatigue by brightness of letters on monitor display was the least for Dark gray followed by Black, Gray and Light gray.

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.

Analysis of Binocular Abnormality by Eyeball Motion in Ametropia (비정시의 안구운동에 의한 양안시 이상 분석)

  • Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.205-213
    • /
    • 2005
  • To evaluate the reliability of binocular vision measurements by phorometry. 90 students volunteered to participate in this study. 25 subjects were males, and 65 were females, they ranged in ages from 21 to 30 years. All subjects had normal ocular and systematic health, and all of them had at least 1.0 visual acuity with their best correction. At negative relative convergence(NRC) measurement in distance, the percentage of subjects is included in expected value(blur point/break point/recovery point) was 78%/61%/67%, divergence excess(DE) was 9%/31%/33%, and divergence insufficience(DI) was 13%/8%/9%, respectively. And positive relative convergence(PRC) measurement, includes expected value was 20%/46%/39%, convergence excess(CE) was 22%/14%/16%, and convergence insufficience(CI) was 35%/40%/45%. AC/A ratios of 42 subjects were normal. 38 were low, and the rest of them high. A low AC/A ratio is usually the result of a small vergence response in relation to accommodation. Negative relative convergence(NRC) at near, includes expected value was 26%/29%/44%, divergence excess(DE) was 61%/33%/24%, and divergence insufficience(DI) was 3%/38%/32%. And PRC at near, includes expected value was 33%/40%/31%, convergence excess(CE) was 61%/23%/42%, and convergence insufficience(CI) was 6%/37%/27%. For the near point of convergence(NPC) test, 58% of their subjects had a break of ${\leq}8cm$ with the accommodative target. In case of NRA(PRA) measurement, the expected value was 41%(33%). Accommodative insufficiency (AI) was 33%(43%), and accommodative excess(AE) was 26%(24%), respectively. AE was related to respectively low values of NRA. AI and CE are associated with high value of NRA, and the dysfunction of convergence excess combined with AE was related to a normal-high values of NRA. PRA in AI was related to a low value, wheres the dysfunction are associated with high values of PRA.

  • PDF

The Factors Influencing the Asthenopia of Emmetropia with Phoria (사위를 가진 정시안의 안정피로에 영향을 미치는 요인)

  • Kim, Jung-Hee;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.71-82
    • /
    • 2005
  • The aim of this study was to provide fundamental data for the factors influencing the asthenopia of emmetropia with phoria and alleviation of asthenopia. A total of 348 subjects, aged between 19 and 30 years old, who had no strabismus, an eye trouble or whole body disease, were examined using corrected visual acuity, corrected diopter, stereopsis and suppression tests from September of 2002 to September of 2004. We excluded 21 subjects for the following reasons: if they had an amblyopia affecting binocular vision or inaccurate data. After these exclusions, 327 subjects remained. We then individually measured the refractive error correction, pupillary distance, optical center distance, phoria, convergence, accommodation and the AC/A as well as the asthenopia during binocular vision using a questionnaire. After analysis of factors affecting asthenopia, we also examined the reductive effect of a prism on the asthenopia in subjects who had asthenopia. To determine the factors affecting asthenopia during binocular vision, statistic analyses were carried out using the Chi-square test and the multivariate Logistic regression model. The results of this study were as follow. For asthenopia during near binocular vision of emmetropia with phoria, in case of the lower the accommodation and convergence, a significantly higher rate of asthenopia was observed (p<0.001). When the AC/A is lower, the higher the rate of asthenopia was observed but not significantly and there was no association between phoria and asthenopia. When the multivariate logistic regression model was used to determine factors affecting binocular vision of emmetropia with phoria, in case of the lower accommodation and convergence, a significantly higher rate of asthenopia was observed. when the phoria is esophoria or higher exophoria, or when the AC/A is lower than normal, the higher the rate of asthenopia was observed but not significantly and there was no association between phoria. AC/A and asthenopia. Therefore accommodation and convergence could be predictive factors for asthenopia during near distance binocular vision. Prism was used among' subjects who had asthenopia during near distance binocular vision, the symptom of asthenopia was eased up to 74.2% in emmetropia with phoria.

  • PDF