• 제목/요약/키워드: vinyl chloride

검색결과 270건 처리시간 0.022초

Potential use of waste rubber shreds in drainage layer of landfills - An experimental study

  • Praveen, V.;Sunil, B.M.
    • Advances in environmental research
    • /
    • 제5권3호
    • /
    • pp.201-211
    • /
    • 2016
  • Laboratory tests were conducted to evaluate the performance of waste rubber shreds in leachate collection layer of engineered landfills. The study found that waste rubber shreds layer in combination with a gravel layer can be of potential use in landfill drainage system. To study the performance, conventional gravel along with waste rubber shreds were used in different combinations (with total layer thickness = 500 mm) as leachate collection media. For the laboratory study poly vinyl chloride (PVC) pipes were used. The size range of waste rubber shreds used were 25 mm to 75 mm in length and width = 10 to 20 mm. The gravel size used in the leachate collection media is 10 mm to 20 mm size. Performance study of 7 Test Cols. with different combinations of waste rubber shreds and gravel bed thickness were studied to find out the best combination. The study found that the Test Col.-3 having waste rubber shreds thickness = 200 mm and gravel layer thickness = 300 mm gave the best results in terms of percentage removal in various physicochemical parameters present in the leachate. Further to find the best size rubber shreds three more Test Cols - 8, 9 and 10 were constructed having the rubber shreds and gravel layer ratio same as that of Test Col.-3 but having rubber shreds width = 10 mm, 15 mm and 20 mm respectively. Based on the results obtained using Test Cols. 8, 9 and 10 the study found that smaller size rubber shreds gave bests results in terms of improvement in various leachate parameters.

PVC-Ni 복합재의 전기적 ${\cdot}$ 기계적 성질에 미치는 Titanate Coupling Agent 의 영향 (The Effect of Titanate Coupling Agents on the Electrical and Mechanical Properties of PVC-Ni Composite Systems)

  • 문탁진;이미경;김선호
    • 대한화학회지
    • /
    • 제29권3호
    • /
    • pp.319-327
    • /
    • 1985
  • 충진제의 함량, titanate계 coupling agent의 종류, 처리량에 따른 PVC-Ni 복합재의 전기적.기계적 성질을 연구하였다. coupling agents처리에 의해 충진제의 분산상태가 양호해지고, 충진제 표면의 불순물이 대체되어 복합재의 전기저항은 감소되며 기계적 성질을 연구하였다. coupling agent처리에 의해 충진제의 분산상태가 양호해지고, 충진제 표면의 불순물이 대체되어 복합재의 전기저항은 감소되며 기계적 성질들은 향상되나 과량의 coupling agent의 처리는 이들 효과를 상쇄함을 보였다.

  • PDF

Characterization of a Newly Isolated cis-1,2-Dichloroethylene and Aliphatic Compound-Degrading Bacterium, Clostridium sp. Strain KYT-1

  • Kim, Eun-Sook;Nomura, lzumi;Hasegawa, Yuki;Takamizawa, Kazuhiro
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권6호
    • /
    • pp.553-556
    • /
    • 2006
  • A cis-1,2-dichloroethylene (cis-DCE)-degrading anaerobic bacterium, Clostridium sp. strain KYT-1, was isolated from a sediment sample collected from a landfill site in Nanji-do, Seoul, Korea. The KYT-1 strain is a gram-positive, endospore-forming, motile, rod-shaped anaerobic bacterium, of approximately $2.5{\sim}3.0\;{\mu}m$ in length. The degradation of cis-DCE is closely related with the growth of the KYT-1 strain, and it was stopped when the growth of the KYT-1 strain became constant. Although the pathway of cis-DCE degradation by strain KYT-1 remains to be further elucidated, no accumulation of the harmful intermediate, vinyl chloride (VC), was observed during anaerobic cis-DCE degradation. Strain KYT-1 proved able to degrade a variety of volatile organic compounds, including VC, isomers of DCE (1,1-dichloroethylene, trans-1,2-dichloroethylene, and cis-DCE), trichloroethylene, tetrachloroethylene, 1,2-dichloroethane, 1,1,1-trichloroethane, and 1,1,2-trichloroethane. Strain KYT-1 degraded cis-DCE at a range of temperatures from $15\;to\;37^{\circ}C$, with an optimum at $30^{\circ}C$, and at a pH range of 5.5 to 8.5, with an optimum at 7.0.

Non-cirrhotic portal hypertension in an ankylosing spondylitis patient

  • Park, Sukki;Lee, Ji Hyun;Choi, Joon Sul;Kim, Hyun Woo;Shim, Beom Jin;Choi, Won Kyu;Kim, Sang Hyun
    • Journal of Yeungnam Medical Science
    • /
    • 제35권1호
    • /
    • pp.89-93
    • /
    • 2018
  • Idiopathic non-cirrhotic portal hypertension (INCPH) is a disease with an uncertain etiology consisting of non-cirrhotic portal hypertension and portal pressure increase in the absence of liver cirrhosis. In INCPH, patients exhibit normal liver functions and structures. The factors associated with INCPH include the following: Umbilical/portal pyremia, bacterial diseases, prothrombic states, chronic exposure to arsenic, vinyl chloride monomers, genetic disorders, and autoimmune diseases. Approximately 70% of patients present a history of major variceal bleeding, and treatment relies on the prevention of complications related to portal hypertension. Autoimmune disorders associated with INCPH are mainly systemic sclerosis, systemic lupus erythematosus and rheumatoid arthritis. To the best of our knowledge, a case of ankylosing spondylitis (AS) associated with INCPH has not been reported thus far. Therfore, we report our experience of a patient with AS accompanied by INCPH, who showed perisplenic varices with patent spleno-portal axis and hepatic veins along with no evidence of cirrhosis on liver biopsy, and provide a brief literature review.

Lipophilic Crown-4 Derivatives as Lithium Ionophores for Lithium Ion Selective Liquid Membrane Electrodes

  • Jae Sang Kim;Sung Ouk Jung;Shim Sung Lee;Si-Joong Kim
    • Bulletin of the Korean Chemical Society
    • /
    • 제14권1호
    • /
    • pp.123-127
    • /
    • 1993
  • New lipophilic Crown-4 compounds of 16-membered rings containing furan (neutral carrier,I), tetrahydrofuran (neutral carrier,II) and lithium complex of the latter (neutral carrier,III) have been synthesized and tested as the active sensors for lithium ion in poly(vinyl chloride) (PVC) membrane electrode, in the presence and absence of an anion excluder, tetrakis(4-chloro-phenyl)borate (KTClPB), 2-nitrophenyl phenyl ether (NPPE), tris(2-ethylhexyl)phosphate (TEHP), o-nitrophenyl octyl ether (NPOE), dioctyl adipate (DOA), bis(2-ethylhexyl)adipate (BEHA), di-n-octylphenyl phosphonate (DOPP) were used as plasticizing solvent mediators. The electrode response function had a nearly Nernstian slope of 54-61 mV per decade (25$^{\circ}$C) within the concentration range of $10^{-1}-10^{-4}$ M LiCl and the detection limits for all electrodes were ca. $5{\times}10^{-4}$ M. The response time of the electrode was faster at the higher lithium concentration and the response of the electrode was stable for longer than 6 months. The sensor membranes exhibit improved response times and increased lifetimes as compared to the system described earlier.

A New Fe (III)-Selective Membrane Electrode Based on Fe (II) Phthalocyanine

  • Ozer, Tugba;Isildak, Ibrahim
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권3호
    • /
    • pp.321-328
    • /
    • 2019
  • A new miniaturized all solid-state contact Fe (III)-selective PVC membrane electrode based on Fe (II) phthalocyanine as a neutral carrier was described. The effects of the membrane composition and foreign ions on the electrode performance was investigated. The best performance was obtained with a membrane containing 32% poly (vinyl chloride), 64% dioctylsebacate, 3% Fe (II) phthalocyanine, and 1% potassium tetrakis (p-chlorophenyl) borate. The electrode showed near Nernstian response of $26.04{\pm}0.95mV/decade$ over the wide linear concentration range $1.0{\times}10^{-6}$ to $1.0{\times}10^{-1}M$, and a very low limit of detection $1.8{\pm}0.5{\times}10^{-7}M$. The potentiometric response of the developed electrode was independent at pH 3.5-5.7. The lifetime of the electrode was approximately 3 months and the response time was very short (< 7 s). It exhibited excellent selectivity towards Fe (III) over various cations. The miniaturized all solid-state contact Fe (III)-selective membrane electrode was successfully applied as an indicator electrode for the potentiometric titration of $1.0{\times}10^{-3}M$ Fe (III) ions with a $1.0{\times}10^{-2}M$ EDTA and the direct determination of Fe (III) ions in real water samples.

Pore Size Control of a Highly Transparent Interfacial Layer via a Polymer-assisted Approach for Dye-sensitized Solar Cells

  • Lee, Chang Soo;Lee, Jae Hun;Park, Min Su;Kim, Jong Hak
    • Korean Chemical Engineering Research
    • /
    • 제57권3호
    • /
    • pp.392-399
    • /
    • 2019
  • A highly transparent interfacial layer (HTIL) to enhance the performance of dye-sensitized solar cells (DSSCs) was prepared via a polymer-assisted (PA) approach. Poly(vinyl chloride)-graft-poly(oxyethylene methacrylate) (PVC-g-POEM) was synthesized via atom-transfer radical polymerization (ATRP) and was used as a sacrificial template. The PVC-g-POEM graft copolymer induced partial coordination of a hydrophilic titanium isopropoxide (TTIP) sol-gel solution with the POEM domain, resulting in microphase separation, and in turn, the generation of mesopores upon calcination. These phenomena were confirmed using Fourier-transform infrared (FT-IR) spectroscopy, UV-visible light transmittance spectroscopy, scanning electron microscopy (SEM), and X-ray diffraction (XRD) analysis. The DSSCs incorporating HTIL60/20 (consisting of a top layer with a pore size of 60 nm and a bottom layer with a pore size of 20 nm) exhibited the best overall conversion efficiency (6.36%) among the tested samples, which was 25.9% higher than that of a conventional blocking layer (BL). DSSC was further characterized using the Nyquist plot and incident-photon to electron conversion efficiency (IPCE) spectra.

Pathological Properties of Cryptococcus pseudolongus on the Mycelia and Fruit Body of Lentinula edodes

  • Kwon, Hyuk Woo;Kim, Seong Hwan
    • Mycobiology
    • /
    • 제49권2호
    • /
    • pp.173-182
    • /
    • 2021
  • Recently, Cryptococcus pseudolongus has been reported as a new pathogen of shiitake (Lentinula edodes). However, its pathological properties are not much known. To further understand its impact on the mushroom, we investigated the pathogen's interactions with the mycelium of shiitake, histopathological properties, host range, and sensitivity to diverse antifungal agents. The strain C. pseudolongus DUCC 4014 inhibited the mycelial growth of L. edodes strain (cultivar Sanjo 701ho) and caused browning in the mycelia confronted with the yeast on PDA. Spray inoculation of the yeast caused an abnormal browning symptom on the cap and/or gills of three shiitake cultivars grown on sawdust media in vinyl bags. Scanning electron microscopic images of the abnormally browned parts of shiitake fruit body illustrated that mushroom tissues were loosed and dispersed in the middle and edge of the cap and the arrangement of basidiospores borne on basidia in the gills was disturbed compared to those of normal shiitake fruit body. Spray inoculation also led to developing abnormal browning on the harvested fruit body, indicating C. pseudolongus could be a problem during mushroom storage. But the yeast was not able to induce abnormal browning on mushrooms of Pleurotus ferulae, Pleurotus fostreatus, and Agaricus bisporus. But it induced browning only on button mushroom (A. bisporus) when they were inoculated after wounding. Tests with 16 kinds of fungicides revealed that the cell growth of C. pseudolongus could be inhibited by benzalkonium chloride at MIC 7 ㎍/ml and benomyl at MIC 3 ㎍/ml.

Membranes of Polyurethanes Containing Crystalline Soft Segments: Oxygen Permeability and Morphology

  • 오효진;김완영;정용섭;이윤식
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권2호
    • /
    • pp.194-198
    • /
    • 2001
  • In order to look for polymeric materials applicable to the oxygen electrode membranes of biosensors, polyurethanes (PUs) were synthesized from poly(butylene succinate) diol (Mn 1150), poly(ethylene glycol) (Mn 200), and 4,4'-methylenebis(cyclohexyl isocyanate). The PUs (Mn 15000-100000) underwent the crystallization and melting transitions in the temperature range of 20-30 $^{\circ}C$ and 90-110 $^{\circ}C$, respectively. The oxygen permeability for the PU membranes prepared by the solution casting method could not be measured since oxygen simply leaked through the membranes with an audible noise. However, when the PUs were blended with carboxylated poly(vinyl chloride) (CPVC), the permeability could be measured. The oxygen permeability coefficient (Po2) of the PU/CPVC $(96}4)$ membranes (6.4 Barrer) was high enough for the application as the electrode membranes. The Po2 decreased dramatically when the CPVC content increased from 4 to 5 wt%, but decreased very slowly and approached to that of CPVC (~0.26 Barrer) when the CPVC content increased further. The scanning electron micrographs of the membranes revealed that the PU membranes were composed of large crystal grains with many pores, but the size of the PU crystal grains and pores decreased progressively with increasing the CPVC content.

Electroanalytical Determination of Copper(II) Ions Using a Polymer Membrane Sensor

  • Oguz Ozbek;Meliha Burcu Gurdere;Caglar Berkel;Omer Isildak
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권1호
    • /
    • pp.66-74
    • /
    • 2023
  • In this study, a new potentiometric sensor selective to copper(II) ions was developed and characterized. The developed sensor has a polymeric membrane and contains 4.0% electroactive material (ionophore), 33.0% poly(vinyl chloride) (PVC), 63.0% bis(2-ethylhexyl)sebacate (BEHS) and 1.0% potassium tetrakis(p-chlorophenyl)borate (KTpClPB). This novel copper(II)-selective sensor exhibits a Nernstian response over a wide concentration range from 1.0×10-6 to 1.0×10-1 mol L-1 with a slope of 29.6 (±1.2) mV decade-1, and a lower detection limit of 8.75×10-7 mol L-1. The sensor, which was produced economically by synthesizing the ionophore in the laboratory, has a good selectivity and repeatability, fast response time and stable potentiometric behaviour. The potential response of the sensor remains unaffected of pH in the range of 5.0-10.0. Based on the analytical applications of the sensor, we showed that it can be used as an indicator electrode in the quantification of Cu2+ ions by potentiometric titration against EDTA, and can also be successfully utilized for the determination of copper(II) ions in different real samples.