• Title/Summary/Keyword: vinyl chloride

Search Result 269, Processing Time 0.021 seconds

Cover Requirements for Corrugated HDPE and PVC Pipes Used for Cross-drains in Highway Construction (고속도로 하부 횡단 배수시설로 사용되는 파형 플래스틱 관의 덮개 요건)

  • Kang, Junsuk;Davidson, James S.;Lim, Jeong-Hyeon;Kang, Young Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • This project investigated the use of two types of thermoplastic pipes, High-Density Polyethylene (HDPE) and Poly-vinyl Chloride (PVC), as cross-drains under highways. Pipes ranging from 0.3 m (12 in.) to 1.5 m (60 in.) in diameter were evaluated under deep fills, minimum cover, and construction loads. In addition to a comprehensive literature review, an analytical study into the allowable fill heights for thermoplastic pipes and a field study to observe the installation and performance of the pipe in service conditions were conducted. Based on the study findings, recommendations regarding how and when thermoplastic pipe should be installed are provided.

Synthesis and Characterization of UV-curable Polyurethane Acrylates Coating Resins for PVC Tiles (PVC 바닥상재용 광경화형 폴리우레탄 아크릴 수지의 합성 및 특성고찰)

  • Zhao, Hong;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1773-1777
    • /
    • 2010
  • The Application of UV curing technique for poly (vinyl chloride) (PVC) floor tiles coating has improved the quality of PVC floor. Several formulations were made including acrylated oligomers based on a polyurethane were blended with reactive monomers, photoinitiators and other additives. The used oligomers are commercial aliphatic urethane acrylates. Thin films were prepared on PVC tiles by bar coating with different formulations using UV radiation. The coating resins were characterized by FTIR. The properties of UV-cured films such as gloss and adhesion were examined. The properties of UV-cured films dependent on the influence of composition and processing conditions was studied.

A Survey of the Kitchen Facilities and Present Meal Situation in the Korean big cities (한국 대도시 가정의 부엌설비 및 조리기구에 관한 실태조사 제I보 : 부엌설비 및 식사현황에 관하여)

  • Kim, Yong-In;Kim, Ki-Sook
    • Korean journal of food and cookery science
    • /
    • v.6 no.1
    • /
    • pp.53-60
    • /
    • 1990
  • This survey was performed to investigate the kitchen facilities and present meal situation in the four Korean big cities; Seoul, Pusan, Kwangju and Taejon. The results are as follows; 1. The kitchen facilities. The number of families with old-fashioned kitchen forms a percentage of 10.8. The kitchen floor consists mainly of polyvinyl chloride materials such as monoryum and vinyl. Gas fuel is mostly used for home cooking. The families equipped waterworks and drainage system in the kitchen cover 92.6% and 85.7% respectively. 2. The present meal situation. Most of the housewives do the cooking for themselves (94.4%) and it is desirable for the health and nutrition of the whole family. The number of families that use the dining kitchen for daily meals covers 53.4%. All the family have their dinner together at most once a week. The instant foods are used frequently in the family whose housewife has a job and the family with high income.

  • PDF

Removal of PVC from Granular Plastic Mixture by Using Air Table (Air Table을 이용한 입상플라스틱 혼합물로부터 PVC의 건식분리)

  • ;Hiroki Yotsumoto
    • Resources Recycling
    • /
    • v.10 no.6
    • /
    • pp.35-42
    • /
    • 2001
  • A study was conducted in order to remove Poly vinyl chloride (PVC) from granular plastic mixture by using Air Table. The motion of plastic particle on Air Table was investigated, and separation test on the plastic mixture with the mixing ratio of PVC 10% and PE 90% was conducted. At the optimum condition obtained from this study, that is frequency of 9.2Hz, air velocity of 1.05 m/sec, End-slope of $7.5 ^{\circ}$, Side-slope of $1^{\circ}$, Feeding speed of 450 g/min, etc., we could separate the PE-PVC mixture to PE (99.96% grade and 98.9% yield) and PVC (88.7% grade and 99.6% yield).

  • PDF

The Influence of Weathering Conditions on the Outer Membrane of Biogas with Plasticized PVC : A Study using Non-destructive Tests

  • Kim, Changhwan;Ki, Wootae;Kim, SangMyung;Shin, Jinyong
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.2
    • /
    • pp.57-62
    • /
    • 2014
  • The biogas holder is composed of an outer membrane and an inner membrane which are subject to outdoor exposure and gas exposure respectively. The influence of weathering conditions on the photo-degradation of a biogas holder was investigated. Tests were performed under three different methods - outdoor exposure tests (Seosan, Arizona), accelerated tests (Xenon-are lamp) with the outer-membrane of biogas. Moreover, the changes in the aging process were monitored using color difference, gloss, the contact angle and an optical microscope. Changes in physical properties, such as decrease reduction in gloss, decrease in the contact angle, increase in color difference were observed in the aging process. The comparison between membrane 3B, 4B and membrane 5B under xenon-arc were discussed. Membrane 5B was very sensitive to ultraviolet (UV) ray. There were many difficulties in the outdoor exposure test due to acid rain, dust, and stain resistance.

Effect of Surfactants on the Electrochemical Performance of Cation-Selective Membrane Electrodes

  • Oh, Hyun-Joon;Cha, Geun-Sig;Nam, Hak-hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • We examined the effect of polyether-type nonionic surfactants (Brij 35, Triton X-100, Tween 20 and Tween 80) on the potentiometric properties of sodium-, potassium- and calcium-selective membranes which are prepared with widely used ionophores and four kinds of polymer matrices [poly(vinyl chloride) (PVC), polyurethane (PU), PVC/PU blend, and silicone rubber (SR)]. It was found that the PVC-based membranes, which provide the best performance among all other matrix-based membranes in the absence of nonionic surfactants, exhibited larger change in their potentiometric properties when nonionic surfactants are added to the sample solution. On the other hand, the sodium-selective SR-based membrane with calix[4]arene, potassium-selective PVC/PU- or SR-based membrane with valinomycin, and the calcium-selective SR-based membrane with ETH 1001 provide almost identical analytical performance in the presence and absence of Tween 20 or Tween 80 surfactants. The origin of nonionic surfactants effect was also investigated by interpreting the experimental results obtained with various matrices and ionophores. The results suggest that the nonionic surfactant extracted into the membrane phase unselectively form complexes with the primary and interfering ions, resulting in increased background potential and lower binding ability for the ionophore. Such effects should result in deteriorated detection limits, reduced response slopes and lower selectivity for the primary ions.

Manganese(II) Ion-Selective Membrane Electrode Based on N-(2-picolinamido ethyl)-Picolinamide as Neutral Carrier

  • Aghaie, M.;Giahi, M.;Zawari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2980-2984
    • /
    • 2010
  • A new poly (vinyl chloride) (PVC) membrane electrode that is highly selective to $Mn^{+2}$ ions was prepared using N,N'-bis(2'-pyridinecarboxamide)-1,2-ethane ($bpenH_2$) as a suitable neutral carrier. This concentration range ($1.0{\times}10^{-5}$ to $1.0{\times}10^{-1}\;M$) with Nernstian slope of $29.3{\pm}0.5\;mV$ per decade. The detection limit and the response time of electrode were $8.0{\times}10^{-6}\;M$ and (${\leq}15\;s$) respectively. The membrane can be used for more than two months without observing any divergence. The electrodes exhibited excellent selectivity for $Mn^{+2}$ ion over other mono-, di- and trivalent cations. Selectivity coefficients were determined by the matched potential method (MPM). The electrode can be used in the pH range from 4.0 - 9.0. The isothermal coefficient of this electrode amounted to 0.00023 V/$^{\circ}C$. The stability constant (log $K_s$) of the $Mn^{+2}$ - $bpenH_2$ complex was determined at $25^{\circ}C$ by potentiometric titration in mixed aqueous solution. The proposed electrode was applied to the determination of $Mn^{+2}$ ions in real samples.

Development of a New Copper(II) Ion-selective Poly(vinyl chloride) Membrane Electrode Based on 2-Mercaptobenzoxazole

  • Akhond, Morteza;Ghaedi, Mehrorang;Tashkhourian, Javad
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.882-886
    • /
    • 2005
  • Copper(II) ion-selective PVC membrane electrode based on 2-mercaptobenzoxazole as a new ionophore and o-nitrophenyl octyl ether (o-NPOE) as plasticizer is proposed. This electrode revealed good selectivity for $Cu^{2+}$ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and concentration of internal solution on the potential response of $Cu^{2+}$ sensor were investigated. The electrode exhibits good response for $Cu^{2+}$ in a wide linear range of 5.0 ${\times}$ 10−.6-1.6 ${\times}$ $10^{-2}$ mol/L with a slope of 29.2 ${\pm}$ 2.0 mV/decade. The response time of the sensor is less than 10 s, and the detection limit is 2.0 ${\times}$ $10^{-6}$ mol/L. The electrode response was stable in pH range of 4-6. The lifetime of the electrode was about 2 months. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, and transition metal ions.

Ammonium Ion Binding Property of Naphtho-Crown Ethers Containing Thiazole as Sub-Cyclic Unit

  • Kim, Hong-Seok;Do, Kyung-Soon;Kim, Ki-Soo;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1465-1470
    • /
    • 2004
  • A short and efficient synthesis, solvent extraction and potentiometric measurements of new thiazole-containing naphtho-crown ethers are reported. The naphthalene moiety enhances the ammonium ion selectivity over potassium ion. The selectivity of ${NH_4}^+/K^+$ follows the trend $3\;{\approx}\;2\;>\;1$, indicating that the differences in conformational changes of 2 and 3 in forming ammonium complexes affect little on the resulting ammonium/potassium extraction selectivity ratio. The ammonium ion-selective electrodes were prepared with noctylphenyl ether plasticized poly(vinyl chloride) membranes containing 1-4 the effect of one naphthalene unit introduced on either right (2) or left (3) side of thiazolo-crown ether on their potentiometric properties (e.g., ammonium ion selectivity over other cations, response slopes, and detection limits) were not apparent. However, the ammonium ion selectivity of 1, 2 and 3 over other alkali metal and alkaline earth metal cations is 10-100 times higher than that of nonactin.

Potential use of waste rubber shreds in drainage layer of landfills - An experimental study

  • Praveen, V.;Sunil, B.M.
    • Advances in environmental research
    • /
    • v.5 no.3
    • /
    • pp.201-211
    • /
    • 2016
  • Laboratory tests were conducted to evaluate the performance of waste rubber shreds in leachate collection layer of engineered landfills. The study found that waste rubber shreds layer in combination with a gravel layer can be of potential use in landfill drainage system. To study the performance, conventional gravel along with waste rubber shreds were used in different combinations (with total layer thickness = 500 mm) as leachate collection media. For the laboratory study poly vinyl chloride (PVC) pipes were used. The size range of waste rubber shreds used were 25 mm to 75 mm in length and width = 10 to 20 mm. The gravel size used in the leachate collection media is 10 mm to 20 mm size. Performance study of 7 Test Cols. with different combinations of waste rubber shreds and gravel bed thickness were studied to find out the best combination. The study found that the Test Col.-3 having waste rubber shreds thickness = 200 mm and gravel layer thickness = 300 mm gave the best results in terms of percentage removal in various physicochemical parameters present in the leachate. Further to find the best size rubber shreds three more Test Cols - 8, 9 and 10 were constructed having the rubber shreds and gravel layer ratio same as that of Test Col.-3 but having rubber shreds width = 10 mm, 15 mm and 20 mm respectively. Based on the results obtained using Test Cols. 8, 9 and 10 the study found that smaller size rubber shreds gave bests results in terms of improvement in various leachate parameters.