• 제목/요약/키워드: video microscopy

검색결과 30건 처리시간 0.023초

거풍도담탕의 백서의 뇌혈류 변화에 미치는 기전연구 (A Mechanism Study of Geopungdodam-tang on the Change of Cerebral Blood Flow in Rats)

  • 송정석;정현우
    • 동의생리병리학회지
    • /
    • 제16권1호
    • /
    • pp.99-103
    • /
    • 2002
  • Geopungdodam-tang(GDT) have been used in oriental medicine for many centuries as a therapeutic agent of apoplexy. The mechanism of GDT on the cerebral blood flow is not known. The purpose of this Study was to investigate effects of GDT on the pial arterial diameter and action mechanism of GDT-induced increased regional cerebral blood flow(rCBF). The changes of regional cerebral blood f1ow(rCBF) was determinated by Laser-Doppler Flowmetry(LDF), and the changes of pial arterial diametet were determinated by video microscopy methods and video analyzer. The results were as follows ; 1. Pial arterial diameter was significantly increased by GDT in a dose-dependent manner. 2. Pretreatment with L-NNA significantly inhibited GDT induced increased rCBF. 3. Pretreatment with methylene blue significantly inhibited GDT induced increased rCBF. 4. Pretreatment with indomethacin inhibited GDT induced increased rCBF. These results suggest that GDT causes a diverse response of cerebral hemodynamics(rCBF and pial arterial diameter). The cerebral hemodynamics is also mediated by nitric oxide synthase, cyclic GMP(guanylyl cydase) and prostaglandin(cyclooxygenase).

전기방사를 이용한 반도체 산화물(ZnO) 나노웹 제조에 관한 연구 (Studies on semiconducting metal-oxide(ZnO) Nanoweb from Electrospinning)

  • 조나경;김한성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.253-253
    • /
    • 2009
  • Electrospinning is one of the simple, cost- efficient methods to produce long continuous semiconducting oxide nanofibers. Polyvinyl Alcohol (PVA) and zinc acetate were used. PVA/Zinc acetate aqueous solutions were electrospun into nonwoven webs. CCD camera, with a lens of long working distance and digital video board were used in capturing the drop and web deposition. The diameter and morphology of nanofibers were analyzed with a Field-emission scanning electron microscopy (FE-SEM). In this study, the average diameter and morphology of nanofibers have been explorered.

  • PDF

Plant Cells on Earth and in Space

  • Braun, Markus;Sievers, Andreas
    • Animal cells and systems
    • /
    • 제4권3호
    • /
    • pp.201-214
    • /
    • 2000
  • Two quite different types of plant cells are analysed with regard to transduction of the gravity stimulus: (i) Unicellular rhizoids and protonemata of characean green algae; these are tube-like, tip-growing cells which respond to the direction of gravity. (ii) Columella cells located in the center of the root cap of higher plants; these cells (statocytes) perceive gravity. The two cell types contain heavy particles or organelles (sataoliths) which sediment in the field of gravity, thereby inducing the graviresponse. Both cell types were studied under microgravity conditions ($10^{-4}$/ g) in sounding rockets or spacelabs. From video microscopy of living Chara cells and different experiments with both cell types it was concluded that the position of statoliths depends on the balance of two forces, i.e. the gravitational force and the counteracting force mediated by actin microfilaments. The actomyosin system may be the missing link between the gravity-dependent movement of statoliths and the gravity receptor(s); it may also function as an amplifier.

  • PDF

Gravure롤 코팅방식에서 비산도료에 의한 비디오 신호의 dropouts (Liquid mist and videotape signal dropouts in gravure roll coating)

  • 김명룡
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권5호
    • /
    • pp.633-639
    • /
    • 1995
  • Dropouts in magnetic media are a primary quality deficiency which is detrimental to magnetic signal quality and thus the major impediment to error-free recording, especially in high density digital recorders. The specific form of defects and causes found to be responsible for signal dropouts occurring in magnetic tape were studied. Dropout occurred when the RF signal falls to low level due to the various types of surface defects. However, the fall in the level of the RF signal in gravure roll coated tapes was most often caused by foreign particles adhering to the magnetic tape. It was also shown from the present study that scattered particles trapped under the tape surface or put on the top can lift it as it crosses the head, creating a spherical tent shaped defect and causing a temporary signal drop. Dropout producing substances were identified through optical and microchemical analyses. The results were correlated with measured electrical signal losses combined with analytical microscopy to clarify source identification of defects.

  • PDF

청피가 뇌혈류역학에 미치는 실험적 연구 (Experimental Study of Citri Reticulatae Viride Pericarpium extract on the Cerebral Hemodynamics in Rats)

  • 이금수;정현우;이원석
    • 동의생리병리학회지
    • /
    • 제16권1호
    • /
    • pp.104-110
    • /
    • 2002
  • Citri Reticulatae Viride Pericarpium extract(CRVP) have been used in oriental medicine for many centuries as a therapeutic agent for Soothing the liver and regulating the circulation of qi(疏肝理氣), and promoting digestion and removing stagnated food(消積化滯). The effects of CRVP on the vascular system is not known. The purpose of this Study was to investigate the effects of CRVP on the pial arterial diameter and regional cerebral blood flow(rCBF) in normal rats and ischemic cerebrovascular pathologic model rats. The changes in rCBF was determinated by Laser-Doppler Flowmetry(LDF), and the changes in pial arterial diameter were determinated by video microscopy methods and video analyzer. The results were as follows ; 1. Pial arterial diameter was significantly increased by CRVP in a dose-dependent manner. 2. Pretreatment with L-NNA significantly inhibited CRVP induced increased rCBF and pial arterial diameter. 3. Both the methylene chloride fraction and the hexane fraction of CRVP dose-dependently improved the altered cerebral hemodynamics of cerebral ischemic animal by increasing rCBF. 4. Pretreatment with L-NNA and indomethacin significantly inhibited CRVP(MC) induced increased rCBF. 5. Pretreatment with L-NNA and indomethacin significantly inhibited CRVP(hexane) induced increased rCBF. 6. Pretreatment with CRVP maredly stabilized the changes rCBF and pial arterial diameter during the period of cerebral reperusion. In conclusion, CRVP causes a diverse response of rCBF and pial arterial diameter, and CRVP dose-dependently improved the altered cerebral hemodynamics of cerebral ischemic animal by increasing rCBF and pial arterial diameter. These results suggest that the improvement of cerebral hemodynamics is also mediated by nitric oxide synthase and cyclooxygenase.

Evaluation of 3-Dimensional Exoscopes in Brain Tumor Surgery

  • Yoon, Wan-Soo;Lho, Hyoung-Woo;Chung, Dong-Sup
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권2호
    • /
    • pp.289-296
    • /
    • 2021
  • Objective : Though the operating microscope (OM) has been the standard optical system in neurosurgery, a new technology called three-dimensional (3D) exoscope has emerged as an alternative. Herein, two types of 3D exoscopes for brain tumor surgery are presented. In addition, the advantages and limitations compared with the OM are discussed. Methods : In the present study, 3D exoscope VOMS-100 or VITOM 3D was used in 11 patients with brain tumor who underwent surgical resection; the Kinevo 900 OM was used only in emergency. After completion of all surgeries, the participants were surveyed with a questionnaire regarding video image quality on the display monitor, handling of equipment, ergonomics, educational usefulness, 3D glasses, and expectation as a substitute for the OM. Results : Among 11 patients, nine patients underwent neurosurgical resection with only 3D exoscope; however, two patients required additional aid with the OM due to difficulty in hemostasis. Regarding video image quality, VITOM 3D was mostly equivalent to the OM, but VOMS-100 was not. However, both 3D exoscopes showed advantages in accessibility of instruments in the surgical field and occupied less space in the operating theater. Differences in ergonomics and educational usefulness between the exoscopes were not reported. Respondents did not experience discomfort in wearing 3D glasses and thought the exoscopes could be currently, and in the future, used as a substitute for the OM. Conclusion : Although many neurosurgeons are not familiar with 3D exoscopes, they have advantages compared with the OM and similar image quality. Exoscopes could be a substitute for OM in the future if some limitations are overcome.

천마반하탕이 뇌허혈로 인한 뇌혈류역학적 변동에 미치는 영향 (Effect of Cheonmabanhwa-Tang on the Changes in Cerebral Hemodynamics in Cerebral Ischemia of Rats)

  • 양기호;윤대영;정현우
    • 동의생리병리학회지
    • /
    • 제18권3호
    • /
    • pp.783-788
    • /
    • 2004
  • Cheonmabanhwa- Tang (CBT) has been used in the Oriental Medicine for many centuries as a therapeutic agent for dizziness due to Poong-Dam, We reported that CBT had effects on the cerebral hemodynamics [regional cerebral blood flow (rCBF), pial arterial diameter (PAD), and mean arterial blood pressure (MABP)] in normal and cerebral ischemic rats. Therefor we designed to determine the mechanism of action of CBT. The changes of rCBF and MABP were determinated by laser-Doppler flowmetry(LDF), and the change of PAD was determinated by video-microscopy. The results were as follows: The CBT-induced increase in rCBF was significnatly inhibited by pretreatment with indomethacin (IDN, 1 ㎎/㎏, i.p.), an inhibitor of cyclooxygenase, or methylene blue (MTB, 10 ㎍/㎏, i.p.), an inhibitor of guanylate cyclase. The CBT-induced increase in PAD was also significantly inhibited by pretreatment with IDN or MTB. The CBT-induced increase in MABP was also significantly inhibited by pretreatment with IDN or MTB. In conclusion, it is suggested that CBT causes a diverse effect on cerebral hemodynamics via mediation of cyclooxygenase and guanylate cyclase.

팔물탕이 뇌혈류역학 변화에 미치는 효과 (Effects of Palmul-Tang on the Change of Cerebral Hemodynamics in Rats)

  • 박철훈;배인태;정현우
    • 동의생리병리학회지
    • /
    • 제18권4호
    • /
    • pp.1014-1020
    • /
    • 2004
  • The study was designed to investigate the effects of Palmul-Tang(PMT) on the change of cerebral hemodynamics [regional cerebral blood flow(rCBF), pial arterial diameter(PAD) and mean arterial blood pressure(MABP)] in normal and cerebral ischemic rats. The change of rCBF and MABP were determinated by laser-doppler flowmetry(LDF), and the change of PAD was determinated by video-microscopy. The results in normal rats were as follows ; PMT significantly increased rCBF and PAD in a dose-dependent, and PMT increased MABP in a dose-dependent. This results were suggested that PMT significantly increased rCBF by dilating PAD. The results in cerebral ischemic rats were as follows ; Both rCBF and PAD were significantly and stably increased by PMT(10㎎/㎏, i.p.) during the period of cerebral reperfusion, which contrasted with the findings of rapid and marked increase in control group. The present authors thought that PMT had an anti-ischemic effect through the improvement of cerebral hemodynamics.

입자 영상 처리 시스템을 이용한 콜로이드 입자의 제타포텐셜 측정 및 나노유체 분산 특성 연구 (A Study on the Zeta Potential Measurement and the Stability Analysis of Nano Fluids using a Particle Image Processing System)

  • 이재근;김성찬;김희중;이창건;주찬홍;이래철
    • 한국분무공학회지
    • /
    • 제8권1호
    • /
    • pp.16-22
    • /
    • 2003
  • Zeta potential measurements of colloid particles suspended in a liquid are performed by a Zeta Meter developed. There are many applications of colloid stability in spray technology, paints, wastewater treatment, and pharmaceuticalse. Zeta potentials of charged particles are obtained by measuring the electrophoretic velocities of the particles using video enhanced microscopy and image analysis program. The values of zeta potential of polystyrene latex(PSL), $silica(SiO_2)$M, polyvinylidence difluoride(PVDF), silicon nitride, and alumina particles in deionized (DI) water were measured to be -40.5, -31.9, -25.2, -15.1 and -10.1mV, respectively. The particles having high zeta potential less than -20 mV are stable in DI water, because the double layers of them have strong repulsive forces mutually, and the particles having low zeta potential over -20mV are unstable due to Van Der Waals forces. Silica(>20nm), PSL, aluminum and PVDF particles were found to be stable that would remain separate and well disperse, while silicon nitride and alumina particles were found to be unstable that would gradually agglomerate in DI water.

  • PDF

천마반하탕이 뇌혈류역학에 미치는 영향 (Effect of Cheonmabanhwa-tang on the Cerebral Hemodynamics in Rats)

  • 양기호;정현우
    • 동의생리병리학회지
    • /
    • 제18권1호
    • /
    • pp.194-199
    • /
    • 2004
  • Cheonmabanhwa-tang(CBT) has been used in the Oriental Medicine for many centuries as a therapeutic agent for dizziness due to Poong-Dam. This study was designed to investigate whether CBT has a cytotoxicity in vitro, and affects the cerebral hemodynamics [regional cerebral blood flow(rCBF), pial arterial diameter(PAD), and mean arterial blood pressure(MABP)) in normal and cerebral ischemic rats. The changes of rCBF were determinated by laser-doppler f1owmeter(LDF), and the change of PAD was determinated by video-microscopy. The results in normal rats were as follows: CBT had no cytotoxicity in neuronal cells. CBT significantly increased rCBF. MABP and PAD in a dose-dependent manner, respectively. Both rCBF and PAD were significantly and stably increased by CBT(10 mg/kg, i.p.) during the period of cerebral reperfusion. which contrasted with the findings of rapid and marked increase in control group. In conclusion, it is suggested that CBT causes a diverse effect on cerebral hemodynamics thereby has an anti-ischemic action.